1
Components
Components Description:
2
Components
Condensate Inlets:
Condensate flows into the housing from Pipe.
FA-4000 1” 1/2” 1”
II. There are 2 condensate inlets. Please refer to illustration as below for
upper inlet or refer to illustration VI. for lower inlet.
3
Components
III. Please install a manual ball valve for discharge impurity and
maintenance.
IV. A full scale ball valve is necessary upstream the FA auto drain for
maintenance purpose. (Caution: Always use full scale ball valve.
Please change previous one if it is not full scale ball valve)
V. In order to check the drain situation more easily, you can install a
section of transparent pipe.
VI. Be careful the slope of inlet pipe. The condensate inlet must be lower
than the lowest point of the tank; or please connect to the lower inlet.
(Please refer to VI.)
VII. Ventilate pipe is necessary if lower inlet is chosen, or the trap can be
not operate。
4
Components
VIII. If you use tubes to connect FA auto drain, please notice the
horizontal status; otherwise it could not work well.
5
Components
Bottom level
The trap won’t drain condensate completely in order to reach the
request of no air loss.
Electricity
I. FA auto drain needs power for operation.
II. The power terminal block should be connected 220VAC. Double
check the label before connects.
6
Components
TEST
TEST
7
Installation
Caution: In order to ensure the trap operate properly, discharge all
condensate out of the equipment before install FA auto drain, and
after installation, please do it again before power on.
1. Inlet pipe size can not smaller than inlet of trap.
2. Never install filter or check valve to ensure the trap can drain smoothly
so the compressor won’t be damaged.
3. The inlet slope downward>1%.
4. Always use full flow ball valve.
5. In order to check the drain situation more easily, install a section of
transparent pipe.
6. The required minimum pressure increases 0.1 bar while the height of
outlet pipe increases 1 meter. The height of outlet pipe can not higher
than 5 meters.
7. Ventilate pipe is necessary if any other inflow problems occur.
8
Installation
Installation
Caution: Ventilate
Each condensate accumulation point must be drained separately;
can’t share the same trap.
If slope in the inlet line is not sufficient or any other inflow problems
occur, a ventilate pipe is necessary.
9
Installation
Electricity connection
Unscrew 4 screws and open the cover(A)
A
Connection details:
Connected
FA auto drain offer one set of voltage-free contact for alarm and monitoring.
10
Installation
Maintenance suggestion
Clean the housing and valve at least once a year
Discharge impurity manually at least once a month
(Especially for micro oil screw air compressor, please comply with this
rule.)
Function test
Press test button for 2 seconds
Valve will open to drain
11
Trouble Shooting
Fault found Possible causes Remedy
LED Power supply ->Check the voltage power
No LED Light problem ->Check plug connection /
Power supply board ribbon cable
defected
Control PCB defected
Inlet or outlet pipe is ->Check pipes
No drain when closed or blocked ->Replace worn parts
press test button Parts worn out ->Check if there is the sound
Control PCB defected of valve opening ( press test
Ball valve defected button several times)
Only drain when The slope of inlet pipe ->Arrange the pipe to be
press test button is not enough suitable slope
Too much condensate ->Install ventilate pipe
Keep drain Pars worn out ->Clean valve
compressed air Control PCB defected ->Replace worn parts
Can not Super Trap may full of -> Push test bottom to
discharge oil discharge
automatically
12