Professional Documents
Culture Documents
清洗吸污车说明书 (1) 1 9 translate
清洗吸污车说明书 (1) 1 9 translate
Directents
I. Overview
This manual describes the correct operation method and maintenance essentials
The number of vacuum pump revolutions is too high, the rotor heating increases;
too low speed causes engine shock, components cause additional impact, affect life,
appropriate working speed, and adjust the maximum adjustment position of the good
throttle in advance.
3, Press the rotation indicated by the red arrow and select the flange installation.
The rotation is wrong, can not play the role of vacuum, and also has a certain
When the first time 4, uses the vacuum pump, please run at a low speed of less
than 300 for 1 minute, and check the leakage and heating up of the pump body.
In the initial stage of 5, new pump is put into operation, completely replace
lubricating oil once after 10 hours, etc. Change oil after work every 50-100 hours. If
the vacuum pump is pumped, inlet or deteriorated, oil shall be replaced immediately.
The 6, shall carefully check the dredging situation of the vacuum pump oil pipe
at any time, and eliminate the blockage and other faults in time.
7, vacuum pump problems to our department in time, do not remove privately,
The can on the inclined road will not only cause deformation of the components
(3) Open the rear door fan before unloading the mud, and avoid to close the
front door fan turning can, due to the danger of turning over after moving the center
of gravity.
When the (4) clutch oil pump extraction box and the vacuum pump extraction
box, the engine is idle, and completes the pedal of stepping into the clutch, and
Special attention for (5) cars when driving: put the suction box operating lever
The (6) shall not be used to inhale and transport waste oil and hazardous
materials.
(7) Support rods and safety blocks must be used when raising the sludge tank
When (8) transports sewage, the hand rear door and window clamping device
must be used. Because there is no wave board in the tank and a high center of gravity,
the vehicle must drive at medium and slow speed without heavy sharp turning and
sharp braking.
2, suction ation method
(1) Preparation before the inhalation operation
correct.
A, Press the clutch pedal, push the suction box operating lever (2) to run the
The C, pulls the throttle handle to the maximum position and observes the
The D, puts the four-way valve (5) transfer handle lever in the suction position,
and check whether the gas pipe exhaust air is correct, the vacuum pump operates
E, Remove the suction hose from the vehicle and put it into the mud well to
Stone, cotton yarn, leaves and other impurities with A, greater than 50mm will
the sewage suction ball valve, and it can easily damage the valve core.
C, suction sludge progress, should often move the suction pipe, when inhaled
high viscosity sludge, occasionally inhaled air and water, can improve the pollution
efficiency.
3, Sewage discharge method
After the muddy water is separated, open the drainage ball valve (10) and
absorb the mud repeatedly after the sewage discharge. The operation method is as
follows.
The (1) places the four-way valve (5) transfer lever in the "neutral-valve"
position, and then places the drain ball valve in the "open" position.
The (2) places the four-way valve conversion in the discharge position, and the
vacuum pump continues to operate, then the tank will be quickly discharged with
When (3) pressure drainage, open the discharge ball valve first to pull the
four-way valve (5) in the discharge position to avoid too high pressure in the tank,
(free) or push the suction box to operate the longitudinal rod (2) (Dongfeng) to run
the pump.
(2) opens the tank door ball valve (11) to drain part of the sewage and reduce
(3) Release the tank door lock tightening device (12), loosen the handle, and
(4) places the tank door opening and closing rod of manual reversing valve (4)
to "open". Before opening, confirm that the tank pressure is the equivalent of
atmospheric pressure, and opening it under negative pressure will damage the tank
The (5) places the flip valve lever of the manual reversing valve in the Up
position.
(6) Recovery operation after sludge discharge: put the flip tank operation in the
"drop" position, and check the following contents after the safe drop.
A, Check that the tank door flange and sealing ring are attached with dirt and
B, places the tank door open closing lever to "closed" and securely closes the
door fan.
The C, will tighten the device screw, insert the tank side screw and turn the
Figure 1
1 Pneumatic 6 Oil and gas 11 Tdoor locking
reversing separator device
valve
2 Lift box 7 Tlip 12 Ball valve
operating cylinder
lever
3 Vacuum pump 8 Slball valve 13 Sewage
suction pipe
4 Manual 9 Open-door 14 Alarm device
reversing oil cylinder
valve
5 Four-way 10 Drainage
valve ball valve
5, High Pressure Cleaning Operation Instructions
The 1, water tank is filled with fire water to open all the switches
2, starts the engine, press the clutch, open the single gear switch
pressure coil to turn the high pressure pipe into the sewer.
Open the water valve when the water enters the high
Do not repair bad parts to operate, side to the pump and power tor and other
Separated oil used as vacuum pump lubricant, but the separated water will be
stored at the bottom of the box, so after the operation, forget to drain, will be inhaled
into the pump to cause sintering and other faults, the oil used for a long time to
Therefore, the interior should be cleaned regularly and the oil replaced. The oil
volume should be supplemented to the middle carving line under the oil gauge when
the vacuum degree is about 93 MPa. Use HT-40# mechanical oil and clean the
Prevent the failure of the automatic suction device in the tank, the device that
works automatically to prevent sewage from entering the pump, inhale the sludge
with more oil, it is easy to replace the ball seat and ball fixing period. In addition, it
is easy to accumulate sewage during the operation, so after the end of the operation
tightened, so the interior should be decomposed and cleaned every 6 months, and the
Figure 5
Use method:
1, turns on the hydraulic controller power switch, and the control power supply
of the controller indicates that the red light is on. When the liquid in the tank is
pumped, the liquid is full, give the alarm, and automatically stop the engine.
The 2, operator shall timely switch the four-way valve in the middle position to
eliminate the vacuum in the tank and prevent the remaining vacuum from causing the
3, turns off the controller power switch and restart the engine to other operating
states.