Surface Drain Headrace Pipe

SOP8

R5
.0
0
R4
.0
0
R3
.75 SOP9 SOP10
R3.5 SOP3
0
R3.00 SOP1
SOP4 SOP2
Penstock Pipe
SOP7

SOP5 SOP11
SOP12

8.00
7.50

1345
7.00
SOP6
6.00

1382.726

Upsurge Level 1380.72


B

C C
Static Water Level 1375.00
V
V
SOP Easting Northing
V
SOP1 423503.762 3130376.947
Normal Water Level 1371.02
1370.598 V
V SOP2 423500.775 3130376.671 NOTES:
V
SOP3 423504.058 3130373.977 1. All dimensions are in meter and Elevations in masl.
Gabion Protection 2. Excavation slopes shall be maintained as per site condition
D D V SOP4 423506.745 3130377.267 under the supervision of site engineer.
V
SOP5 423503.463 3130379.955 3. Steel for Penstock pipe shall confirm to IS 2062: Grade
1365.596
Downsurge Level 1364.87
SOP6 423503.265 3130381.942 4. The pipe is exposed unless mentioned.
SOP7 423508.733 3130377.462 5. In case of buried pipe, the depth of the cover shall be at
V

0.3m*0.3m Seepage Rings


Surface Drain least 1.2m. Compaction of soil on top of the pipe shall be
E SOP8 423504.255 3130371.997 carefully carried out in such a way that the shape of the
E
V

1360.34 SOP9 423499.009 3130374.868 pipe is not distorted.


1359.34
SOP10 423496.022 3130374.57
V

6.00 2.00 6.00 SOP11 423495.702 3130377.795


V

1.00 1.00 SAB01 SOP12 423498.687 3130378.093


M25 Concrete
0.1m PCC 2.5 5.0 7.5 10.0 12.5m
0.0
0.15m Stone Soling
V

SCALE
V

SECTION A-A

UN
IT S E N G IN
V

CY
EE
R

N
IN T A
G C
O NS U L
V

V
ANCHOR BLOCK 40
8.00
7.50
7.00
50
6.00 0.

1382.726

00
Upsurge Level 1380.72 6.
V

V
V
C C
V Static Water Level 1375.00
V
V

Normal Water Level 1371.02

22.38
1370.598

23.38
V

V
0.3m*0.3m Surface Drain SECTION C-C
D D
V SCALE B
V 1365.596
Downsurge Level 1364.87

E E
1360.34

1359.34

6.00 NOTES:
1.00
1.00 1.00 1.00 1. All dimensions are in meter and Elevations in masl.
M25 Concrete 2. Excavation slopes shall be maintained as per site condition
0.1m PCC under the supervision of site engineer.
0.15m Stone Soling
3. Steel for Penstock pipe shall confirm to IS 2062: Grade
SECTION B-B
SCALE A 4. The pipe is exposed unless mentioned.
5. In case of buried pipe, the depth of the cover shall be at
least 1.2m. Compaction of soil on top of the pipe shall be
carefully carried out in such a way that the shape of the
0 pipe is not distorted.
1.0

0
6.0

0.0 2.5 5.0 7.5 10.0 12.5m


5
0.7
SCALE

0
6.0

UN
IT S E N G IN

CY
EE
SECTION E-E R

N
IN T A
G C
O NS U L

SCALE B

SECTION D-D
SCALE B