Download as pdf
Download as pdf
You are on page 1of 3
GENSTRU AV cocunasi rine GENSTRU CONSULTANTS PVT. LTD (Doe. leon Laboratory test results- Fine Aggregate Soundness test | Name Doc. No. 8-06 Issue No: | 03 [Rev No: issue Dt: | 01/01/2022 Test FINE AGGREGATE SOUNDNESS TEST REFERENCE CODE 15 2386 Part S Equipment Functional Checks Balance: |. Check ifthe reading is zero before taking the weight. Ifnot press the tare button on the balance to set the reading to zero. Before taking the actual reading, place the sample and check if there is change in the reading and after removing the sample, the balance reads zero. Sieve 1. Examine the mesh for iregularities, such as dents or depressions Examine sieve is clean and free from any dirt/particles cling to the frame Individual Quantity of Sample ‘Taken for Specific Size for Analysis ‘The sample shall be of such a size that twill yield not less than 100 g of each of the following sizes. Passing 15 Slere Retained on IS Steve 300-micron 600.micron, Fam 2:36.mm 473mm, 0000ui Scanned with CamScanner ‘GENSTRU CONSULTANTS PVT. LTD (Doc. Mane | taboratory test results Fine Aparegate Soundness test S GENSTRU smarts "Doc. No. | GCPL/GF/FIAG-7-1-8-06 IssueNo: | 03 Rev.No:|- Rev. Dt: ]- Tesue Dt: | 01/01/2022 _ vate] g- 8-22 LbIDNo.| ETAW-22 -~ool Room Temperature cq) 2% Relative Humidity(%)| of 5} Type of Re-AgEM | 0.504 / MgSOx Date &Timeof Date time Solution Prepared 06-08-20 V2 .30 Pm Temp. OfSotution Qez | Number of Gyles oS | Date Tine of] Temp. | SPs T Oste a time of Semple Removed | Date & Time of Sample Keptin | ce | SmPmmeesin | of | aay Teac | tse toon | 1 A eee | ena (araintorisesmia) | for Ato 18s. | Wo. | fortetoisies. | fC | souson ste Date | _1_|elsin be || 9-38-22 2 |sigtar Jo B= 3 lolain |4so [26.4 [142] y-g-7 4 Iufslaz! ja-ns]293 [Vitel -a-w [ai a Shaictaliasss! eget [19 Wye e-27 | 9: so aml tS-a-1 | Lerjomed We Retained _, a, fers Weight of Test Fraction Before Test gms 475 2.36 196. = 236 as 3.6. \eo: 138 06 a a \oo-e Os: (030 a loo-0 [03 045 Sa.l = [015 = ‘Note: Sizes finer than 300 microns IS sieve shall be assumed to have zero percent loss ObUlve er a ea Scanned with CamScanner ] GENSTRU CONSULTANTS PVT. LTD . Roe, | Laboratory test results Fine Aggregate Soundness test Za GENSTRU “ss Doc. No. | GCPL/QF/FIAG-7-1-8-06 Issue No: [03 [Rev.No: | ~ [Ree + Issue Dt.: | 01/01/2022 [Quantitative Examination: i = — > | sameesize Testyde | Original wt. of Sampe-ams. | Meleh Resine’ After Each | s 2 (00.00 460 | | 2.B6 rm rz | ied 2 sto 45-60 | Emm a 95.60 93.50 | 4 43-50 S210 | s 92:\0 S110 | i (oo 42.20 _| [19mm te 2 ge. 35. 6o O'6o0me, * | 5 = lq. 1 (O'Gearny +o 5 - f 3 | OSmey + | | 5 1 : | B _ | 4 | 5 REMARK: - Clube Scanned with CamScanner

You might also like