2400
6.0 ALL PANELBOARDS, MAIN DISTRIBUTION PANELS, ETC SHALL HAVE GROUNDING BUS
FOR BRANCH CIRCUITS AND SUB-FEEDER GROUNDING SYSTEM, MAIN GROUNDING PP
POWER PANEL
SYSTEM SHALL BE BONDED TO THE NEAREST METAL WATER PIPE IN SERVICE.
MCB MAIN CIRCUIT BRAKER
1900
7.0 MOUNTING HEIGHTS FOR ALL WIRING DEVICES AND PANELBOARDS SHALL BE AS DUPLEX (LOCATED ON POWDER ROOM)
1800mm.
FOLLOWS: B. INTERIOR WIRING CIRCUIT HOMERUN TO PANELBOARD
PANELBOARD DESIGNATION, LETTER INDICATES PANEL
7.1 LIGHTING SWITCHES 1.2 m ABOVE FLOOR FINISH 1.0 LIGHTING FIXTURE LP-A
1 WHILE NUMBER INDICATES CIRCUIT NUMBER
7.2 CONVENIENCE OUTLET 0.3 m ABOVE FLOOR FINISH 1 - POLE CIRCUIT BREAKER WITH NON-TRIPPING CIRCUIT
1200mm.
EMERGENCY LIGHT, WITH BATTERY BACK UP POWER, "OMNI" 1P+N BREAKER FOR THE NEUTRAL LINE
7.3 TELEPHONE OUTLET 0.3 m ABOVE FLOOR FINISH
7.4 PANELBOARDS AND CABINETS 1.8 m ON TOP ABOVE FLOOR FINISH LIGHTING FIXTURE, WALL-MOUNTED
7.5 MOTOR CONTROL AND ECB 1.8 m ON TOP ABOVE FLOOR FINISH
7.6 MANUAL TRANSFER SWITCH 1.8 m ON TOP ABOVE FLOOR FINISH PIN LIGHT LIGHTING FIXTURE
1000
7.7 EMERGENCY LIGHT FIXTURE 0.3 m BELOW CEILING LINE
FLUORESCENT LIGHTING FIXTURE, STRIP
300mm.
CEILING AND WOODEN PARTITIONS.
POLYVINYL CHLORIDE (PVC)- IF EMBEDDED
IN CONCRETE OR HOLLOW BLOCK. FLOOR FINISH
8.3 TELEPHONE AND CATV SYSTEM POLYVINYL CHLORIDE (PVC) **IF APPLICABLE** 2 LEGEND & ABBREVIATION
8.4 ALL VIBRATING EQUIPMENT (MOTORS) LIQUIDTIGHT FLEXIBLE CONDUIT **IF APPLICABLE**
8.5 JUNCTION BOX TO LIGHTING FIXTURE FLEXIBLE METAL CONDUIT, 10mmØ E 1 SCALE: NTS 4 MOUNTING HEIGHT DETAIL
NOTE: ALL INDICATED CONDUIT SIZES ARE INSIDE DIAMETERS. (WITH CONNECTORS)
E 1 SCALE: NTS
9.0 LIGHTING FIXTURES WITH FLUORESCENT TUBE SHALL HAVE THERMAL
PROTECTOR HIGH-POWER FACTOR BALLAST.( PRE-HEAT )
10.0 ALL CABLE SPLICES AND TERMINATIONS AT BUS BARS AND CIRCUIT BREAKERS
SHALL BE CRIMP-TYPE TERMINAL LUGS.
11.0 MECHANICAL EQUIPMENT WITH HIGH VIBRATION MOVEMENTS SHALL HAVE
FLEXIBLE CONDUIT CONNECTION FROM MOTOR TERMINAL BOX TO OVERCURRENT
DEVICE ENCLOSURE ( ECB ). TYPE OF WIRE NUMBER OF WIRES IN CONDUIT
12.0 PRIOR TO ITS MOUNTING AND TERMINATION OF LIGHTING FIXTURES, WIRING (mm²) 15Ø C 20Ø C 25Ø C 32Ø C 25mmØ HOLE
DEVICES, EQUIPMENT, ETC... CONTRACTOR SHALL ENGAGE WITH THE CONSULTANT
OR OWNER'S REPRESENTATIVE FOLLOWING FIELD ACCEPTANCE TEST AND
MATERIAL INSPECTION: THHN WIRE 2.0 & 3.5 1-2 3-4 5-7 8-10 50mm THICK CONCRETE COVER
12.1 BRANCH CIRCUITS AND SUB-FEEDER INSULATION RESISTANCE TEST MEASUREMENT
12.2 POLARITY TEST ON WIRING DEVICES
12.3 GROUND RESISTANCE TEST MEASUREMENT
12.4 MATERIALS QUALITY INSPECTION AS REQUIRED IN THE ABOVE SPECIFICATION EXOTHERMIC WELD
3 WIRING & CONDUIT SCHEDULE
300mm
12.5 GROUND WELL RESISTANCE TEST MEASUREMENT FOR LIGHTNING SYSTEM
200mmØ CONCRETE PIPE BODY
13.0 NO CHANGE AND MODIFICATION SHALL BE MADE WITHOUT THE CONSULTANT/ E 1 SCALE: NTS
DESIGNER'S WRITTEN CONSENT. GROUND WIRE, 60mm²
TW IN 50Ø PVC 20mmØ x 3.0m GROUND ROD
14.0 ALL WORKS SHALL BE EXECUTED IN A WORKMANSHIP MANNER AND SHALL PRESENT CONDUIT UP TO ROOF LONG COPPER CLAD STEEL
A NEAT AND ORDERLY ACCEPTANCE. ALL WIRINGS SHALL BE CONCEALED AS MUCH AS DECK
POSSIBLE.
THE ELECTRICAL SYSTEMS FOR THIS PROJECT HAVE BEEN DESIGNED USING CIRCUIT BREAKERS 200mm
TIME-CURRENT CURVES AND SELECTIVE COORDINATION METHOD FOR SHORT CIRCUIT CALCULATIONS.
USING OTHER BRANDS OF CIRCUIT BREAKERS SHALL NOT GUARANTEE THE SAFETY OF PERSONNEL
FROM ARC FLASH DURING SHORT CIRCUITS, AND PROTECTION OF THE BUILDING. GROUND ROD INSTALLATION
1 GENERAL NOTES 5 GROUND ROD DETAIL
E 1 SCALE: NTS E 1 SCALE: NTS
PROFESSIONAL ELECTRICAL ENGINEER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK
solely property of Villa Preciosa PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 5/28/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC Validity REMARKS HILDA ARELLANO PIZA E-1
it's architect is not valid. PTR Issued CONTENT GENERAL NOTES & PROJECT LOCATION ADDRESS
Place DETAILS STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
PANEL BOARD: MAIN CB, AT/AF: 60AT/63AF MOUNTING: JUNCTION BOX & UTILITY BOX
CKT 3 CKT 4
15 AT 15 AT
2ND FLOOR
1 SETS OF 2-14mm² THHN (H),
CKT 5 CKT 6 1-8mm² THHN (N),
15 AT 20 AT EXISTING TRANSFORMER 1-8.0 mm² TW (G), 230 V , 60AT,
(CITY SOURCE) IN 25 mmØ IMC] 2 POLE
SERVICE
BENECO INCOMING ENTRANCE
CKT 9 CKT 10
30 AT 30 AT
GROUND FLOOR
CKT 11 SPARE
30 AT 20 AT
PROFESSIONAL ELECTRICAL ENGINEER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK
solely property of Villa Preciosa PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 5/28/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC Validity REMARKS HILDA ARELLANO PIZA E-2
it's architect is not valid. PTR Issued CONTENT LOAD SCHEDULE & PROJECT LOCATION ADDRESS
Place DIAGRAMS STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
NOTE: NOTE:
2 - 2.0 mm² (No. 14)THHN 2 - 2.0 mm² (No. 14)THHN
@ 20mm R-PVC CONDUIT @ 20mm R-PVC CONDUIT
FOR A 15 Amp CIRCUIT B C FOR A 15 Amp CIRCUIT B C
2500 2500
A 1 A
E C E
R IANC IAN
VA VAR
N E
L I
T Y
E R
O P
P R
4 dd
q ROO
F LIN
E
g
q p
CKT 3
15 Amp
a dd
Spq
v
3
3
a
E
Sg
a g
N
b b Skl
I
Sa k
L
w
1931
1931
So c cc Su Sru r
o x u
Y
c l
T
h h
4231 Meter
4231 Meter
CKT 2
R
PB 15 Amp
Shj
Sbc s
E
y
2
2
Sw
Sxy
P
j i CKT 1 Sbbccdd
O
Smn 15 Amp St
S³aa Si Sf CKT 4 Ss
R
i 15 Amp bb bb Sz t
P
2300
2300
d Sde f to S³aa (@ GF)
l S³aa
to S³aa
OPEN ABOVE
(@ GF) e
aa
1
1
n n m z
CKT 5
15 Amp
3 2
R O A D
PROFESSIONAL ELECTRICAL ENGINEER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK
solely property of Villa Preciosa PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 5/28/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC Validity REMARKS HILDA ARELLANO PIZA E-3
it's architect is not valid. PTR Issued CONTENT LIGHTING LAYOUT PROJECT LOCATION ADDRESS
Place STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
NOTE: NOTE:
1. 2 - 3.5 mm² (No. 12)THHN @ 1. 2 - 3.5 mm² (No. 12)THHN @
20mm R-PVC CONDUIT 20mm R-PVC CONDUIT
FOR A 20 Amp CIRCUIT FOR A 20 Amp CIRCUIT
2. 2 - 5.5 mm² (No. 10) THHN
@ 20mm R-PVC CONDUIT
B C 2. 2 - 5.5 mm² (No. 10) THHN
@ 20mm R-PVC CONDUIT
B C
FOR A 30 Amp CIRCUIT FOR A 30 Amp CIRCUIT
2500 2500
A 1 A
E E
RI ANC IA NC
VA VAR
N E
L I
T Y
E R
O P
P R
4 CKT 6
20 Amp
a1
b2 b4
a2
3
3
E
N
CKT 9 b5
I
L
30 Amp
1931
1931
b1
Y
CKT 8
CKT 11
T
30 Amp CKT 7
a3
4231 Meter
4231 Meter
30 Amp
R
PB 20 Amp
E
2
2
UP b3
P
O
CKT 10
R
a6 30 Amp DN
P
2300
2300
b6
a4 b7
a5
1
1
P R O P E R T Y L I N E
3 2
R O A D
PROFESSIONAL ELECTRICAL ENGINEER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK
solely property of Villa Preciosa PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 5/28/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC Validity REMARKS HILDA ARELLANO PIZA E-4
it's architect is not valid. PTR Issued CONTENT POWER LAYOUT PROJECT LOCATION ADDRESS
Place STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600