Time Delay Relays

FEATURES BENEFITS
Up to 10 Functions 5 Timing Functions Controlled via Supply Voltage
4 Timing Functions Controlled via Trigger Input
1 Timing Function of Memory Latching Relay
Broad Timing Range (from 0.1 sec to 10 days) Meets Most Timing Requirements
Contact Configuration SPDT or DPDT
Universal Power Supply 12 to 240 VAC/VDC
2 LED Status Indicators Indicates Coil Status at a Glance
Only 17.5 mm Wide Ideal for Tight Spaces
DIN Rail Mountable Easy Installation / No Tools
RoHS Compliant Environmentally Friendly

This device is designed for connection of 1-phase voltage, 12-240 V AC/DC and must be installed according to norms valid in existing state. Connections must be made according to details in
this instruction sheet. Installation, connections, setting and servicing should be performed by qualified electrician staff, who understands this instruction sheet and functions of respective device.

Before starting installation ensure that the main switch is in “OFF“ position and there should be no power going to the device. Qualified installer must also ensure the device is being installed
into a temperature controlled environment which will guarantee not to exceed the specified maximum operating temperature. For installation use a screwdriver with 2 mm tip.

DESCRIPTION
Function Operation Timing Chart
Input Voltage Terminals A. When the input voltage U is applied, timing delay t begins. Relay
ON DELAY contacts R change state after time delay is complete. Contacts R U
Control Input “S” Power On return to their shelf state when input voltage U is removed.
on
Trigger switch is not used in this function. R off t t
Input Voltage Output Indication
Indication B. When input voltage U is applied, time delay t begins. When
Time Range REPEAT time delay t is complete, relay contacts R change state for time U
Adjustment within Setting CYCLE delay t. This cycle will repeat until input voltage U is removed. t t t
Range
Starting Off Trigger switch is not used in this function. R on
off
t t t
Function Setting
C. When input voltage U is applied, relay contacts R change state
INTERVAL immediately and timing cycle begins. When time delay is U
Power On complete, contacts return to shelf state. When input voltage U is
removed, contacts will also return to their shelf state. Trigger t t
switch is not used in this function.
R on
off

D. Input voltage U must be applied continuously. When trigger S is


OFF DELAY closed, relay contacts R change state. When trigger S is opened, U
S Break delay t begins. When delay t is complete, contacts R return to their
close
shelf state. If trigger S is closed before time delay t is complete, S open
Output Contact then time is reset. When trigger S is opened, the delay begins
t t
again, and relay contacts remain in their energized state. If input on
voltage U is removed, relay contacts R return to their shelf state. R off

E. Upon application of input voltage U, the relay is ready to accept


RETRIGGE- trigger signal S. Upon application of the trigger signal S, the relay
RABLE contacts R transfer and the preset time t begins. At the end of the U
ONE SHOT preset time t, the relay contacts R return to their normal condition
TIME RANGES unless the trigger signal S is opened and closed prior to time out t
S
close
open
(before preset time elapses). Continuous cycling of the trigger
signal S at a rate faster than the preset time will cause the relay
t t
on
contacts R to remain closed. If input voltage U is removed, relay R off
h h h h h contacts R return to their shelf state.
m 1 10 m 1 10 m 1 10 m 1 10 m 1 10
10 1 d 10 1 d 10 1 d 10 1 d 10 1 d
1 10 1 10 1 10 1 10 1 10
10 ON 10 ON 10 ON 10 ON 10 ON
F. When input voltage U is applied, relay contacts R change state
S1 OFF S1 OFF S1 OFF S1 OFF S1 OFF FLASHER immediately and time delay t begins. When time delay t is U
Starting On complete, contacts return to their shelf state for time delay t. This t t t
0.1 - 1s 1 - 10s 0.1 - 1 min 1 - 10 min 0.1 - 1 h cycle will repeat until input voltage U is removed. Trigger switch
R on t t
is not used in this function. off

G. Upon application of input voltage U, a single output pulse of 0.5


PULSE seconds is delivered to relay after time delay t. Power must be U
m
h
1 10 m
h
1 10 m
h
1 10 m
h
1 10 m
h
1 10
GENERATOR removed and reapplied to repeat pulse. Trigger switch S is not
1 d 1 d 1 d 1 d 1 d
1
10
10 1
10
10 1
10
10 1
10
10 1
10
10 used in this function. R on
off
t t
10 ON 10 ON 10 ON 10 ON 10 ON
S1 S1 S1 S1 S1
U
OFF OFF OFF OFF OFF
H. Upon application of input voltage U, the relay is ready to accept
ONE SHOT trigger signal S. Upon application of the trigger signal S, the relay
1 - 10 h 0.1 - 1 day 1 - 10 days only ON only OFF contacts R transfer and the preset time t begins. During time-out,
the trigger signal S is ignored. The relay resets by applying the S close
open
trigger signal S when the relay is not energized.
on
t t
R off

I. Input voltage U must be applied continuously. When trigger S U


ON/OFF is closed, time delay t begins. When time delay t is complete,
DELAY relay contacts R change state and remain transferred until close
S
WIRING DIAGRAMS S Make/Break trigger S is opened. If input voltage U is removed, relay
contacts R return to their shelf state.
open
t t
R on
off t t
INPUT J. Input voltage U must be applied continuously. Output changes U
VOLTAGE MEMORY state with every trigger S closure. If input voltage U is removed,
LATCH relay contacts R return to their shelf state.
Un Un S Make S close
open
+ - EXTERNAL + -
on
CONTROL R off
SWITCH
15 - COMMON
A1 S A2 A1 S A2 16 - NORMALLY CLOSED
18 - NORMALLY OPEN
R
25 - COMMON
25 26 28 26 - NORMALLY CLOSED
28 - NORMALLY OPEN
R R

15 16 18 15 16 18
SPDT DPDT
901-0000-281
Modular Style July 2018, Rev C

Time Delay Relays

SPECIFICATIONS @ 25°C (UL 508) DIMENSIONS INCHES (MILLIMETERS)


OUTPUT CHARACTERISTICS
SPDT or DPDT 2.6 MAX
Number and type of contacts (65) 0.7
Contact material Silver alloy 1.35 (17.6)
(34.2) 0.13
Current rating 15 A @ 240 VAC, 0.63 (3.4)
(16)
240 V 50/60 Hz
0.6
1/2 HP @ 120 V 50/60 Hz (14.2)
Switching voltage 1 HP @ 240 V 50/60 Hz
B300 pilot duty 0.2
(5)
Minimum switching requirement 100 mA
Indication Red LED
3.5 1.8 1.4
INPUT CHARACTERISTICS (90) (45.3) (35)
Voltage range 12 to 240 V 50/60 Hz/ VDC
2.7
Operating range (% of nominal) 85% to 110% (67.5)
Maximum consumption 3 VA (AC) (DPDT)

1.7 W (DC)
Indication Green LED
TIMING CHARACTERISTICS
Functions available 10 0.7
1.3 0.3 (16.71)
Time scales 10 (34) (7.4)

Time ranges 0.1 sec to 10 days


(DPDT)

Tolerance (mechanical setting) 5%


Repeatability (constant voltage and temperature) 0.2% 0.6
0.236 (16)
Reset time (maximum) 150 ms (6)

Trigger pulse length (minimum) 50 ms


PERFORMANCE CHARACTERISTICS
Electrical life (operations @ rated current) 100,000 cycles (resistive)
Mechanical life (unpowered) 10,000,000 cycles
Dielectric strength Input to contacts 2500 VAC
Between open contacts 1000 VAC
Terminal wire capacity 14 AWG (2.1 mm2)
Terminal torque (maximum) 7.1 lbf in (0.8 Nm)
Field Wiring 75C Conductors
ENVIRONMENT
Product certifications UL, CE, RoHS
Ambient air temperature Storage -30 to +70 °C (-22 to +158 °F)
Around the device Operation -20 to +55 °C (-4 to +131 °F)
Degree of protection IP 20
Weight 65 grams (2.3 oz)

LOAD
RELAY
CONTACT DC1
15 A AC1A C3 AC15 (24/110/220 V)
70μF

AgNi 1000 W 4000 VA 0.9 kW 750 VA 15 A/0.5 A/0.35 A