JOB CARD PACKAGE TITLE: BOV - A330

chip detector Tail Number - MSN -


FSN
ALL

Reference Title DocType


Inspect Master Magnetic Chip Detector for Evidence
79-00-00-200-805-A AMM
of Abnormal Deposits

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 1 of 1


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

** ON A/C FSN ALL


TASK 79-00-00-200-805-A
Inspect Master Magnetic Chip Detector for Evidence of Abnormal Deposits

WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS


AFTER ENGINE SHUTDOWN. THE ENGINE PARTS CAN STAY HOT
FOR ALMOST ONE HOUR. DO NOT TOUCH HOT PARTS WITHOUT
APPLICABLE GLOVES. HOT PARTS CAN CAUSE INJURIES TO
PERSONNEL.

WARNING: YOU MUST NOT LET ENGINE OIL STAY ON YOUR SKIN. FLUSH
THE OIL FROM YOUR SKIN WITH WATER. THE OIL IS
POISONOUS AND CAN BE ABSORBED INTO THE BODY.

CAUTION: YOU MUST NOT LET ENGINE FUEL OR OIL FALL ON THE
ENGINE. UNWANTED FUEL OR OIL MUST BE REMOVED
IMMEDIATELY WITH A CLEAN LINT-FREE CLOTH. THE FUEL OR
OIL CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND
TO SOME PARTS.

CAUTION: DO NOT PUT OIL DRAINED FROM THE ENGINE BACK INTO THE
ENGINE OIL SYSTEM. CONTAMINATION IN THE OIL CAN CAUSE
DAMAGE TO THE OIL SYSTEM.

1. Reason for the Job


Refer to the MPD TASK: 792000-R3
INSPECT MASTER MAGNETIC CHIP DETECTOR FOR EVIDENCE OF
ABNORMAL DEPOSITS.

This TASK gives you the procedure to examine the master Magnetic Chip
Detector (MCD) for contamination.

NOTE: The installation of Scavenge MCDs for diagnostic purpose is given


in RR SB 79-B040 (optional). If the engine is operated with more
MCDs installed, they must be inspected at the same time as the
Master MCD.

2. Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 1 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

REFERENCE QTY DESIGNATION


No specific AR ACCESS PLATFORM 3M (10 FT)-
ADJUSTABLE
No specific AR CONTAINER-NON METALLIC
No specific 1 MAGNIFYING GLASS POWER 05X
No specific AR SAFETY CLIP - CIRCUIT BREAKER

B. Consumable Materials

REFERENCE DESIGNATION
OMat 101 kerosene

C. Work Zones and Access Panels

ZONE/ACCESS ZONE DESCRIPTION


811
FOR 4030EM1(POWERPLANT-DEMOUNTABLE, ENG 1)
416BR
FOR 4030EM2(POWERPLANT-DEMOUNTABLE, ENG 2)
426BR

D. Referenced Information

REFERENCE DESIGNATION
Ref. Energize the Ground Service Network
24-42-00-861-801-A
Ref. De-energize the Ground Service Network
24-42-00-862-801-A
Ref. Inspection of the Scavenge Oil Filter Element
79-00-00-200-804-A

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 2 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

REFERENCE DESIGNATION
Ref. Inspection of the Diagnostic Magnetic Chip
79-00-00-200-806-A Detectors (MCDs) to Find the Source of the
Contamination on the Master MCD or EMCD
Ref. Removal of the Magnetic Chip Detectors
79-22-46-000-801-A
Ref. Installation of the Magnetic Chip Detectors
79-22-46-400-801-A
Ref. Fig. Swarf
Ref. Fig. Fines
Ref. Fig. Flakes
Ref. Fig. Chips

3. Job Set-up

SUBTASK 79-00-00-861-065-A
A. Energize the ground service network
Ref. AMM TASK 24-42-00-861-801.

SUBTASK 79-00-00-941-065-A
B. Safety Precautions
(1) Make sure that the engine 1, (2) shutdown occurred not less
than 5 minutes before you do this procedure.

SUBTASK 79-00-00-010-086-A
C. Get access to the avionics compartment.
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in
position at the access door 811.
(2) Open the access door 811.
(3) Open the protective door of the AC/DC emergency power-
center 740VU.

SUBTASK 79-00-00-865-085-A

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 3 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

D. Open, safety and tag the circuit breaker(s) that follow(s). Use the
SAFETY CLIP - CIRCUIT BREAKER as necessary.

PANEL DESIGNATION FIN LOCATION


FOR FIN 4030EM1(POWERPLANT-DEMOUNTABLE, ENG 1)
722VU FADEC B ENG 1 13KS1 D44
742VU FADEC A ENG 1 12KS1 Q73
FOR FIN 4030EM2(POWERPLANT-DEMOUNTABLE, ENG 2)
722VU FADEC B ENG 2 13KS2 K49
742VU FADEC A ENG 2 12KS2 Q74

SUBTASK 79-00-00-010-098-A
E. Get access to the master MCD:
(1) Open the MCD access panel:

(a) FOR 4030EM1 (POWERPLANT-DEMOUNTABLE,


ENG 1)
416BR

(b) FOR 4030EM2 (POWERPLANT-DEMOUNTABLE,


ENG 2)
426BR

4. Procedure

SUBTASK 79-00-00-210-064-A
A. Do an inspection of the master MCD for contamination

NOTE: A description of the contamination that can be found is


given:
Ref. Fig. Swarf
Ref. Fig. Fines
Ref. Fig. Flakes
Ref. Fig. Chips

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 4 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

(1) Remove the master MCD Ref. AMM TASK 79-22-46-000-801.


(2) Clean the master MCD.

WARNING: BE CAREFUL WHEN YOU USE


CONSUMABLE MATERIALS. OBEY THE
MATERIAL MANUFACTURER'S
INSTRUCTIONS AND YOUR LOCAL
REGULATIONS.
(a) Put the MCD probe in clean kerosene (Material Ref.
OMat 101) and remove all the oil. The kerosene
(Material Ref. OMat 101) must be in a clean
CONTAINER-NON METALLIC which is not made of
metal.

(3) Examine the master MCD probe in a good light for


contamination. Use a MAGNIFYING GLASS POWER 05X
which will show the contamination at least five times larger than
its correct dimensions.
(4) The permitted standards for contamination on the master MCD
are as follows:

CAUTION: YOU MUST REPLACE THE ENGINE IF THE


MATERIAL ON THE MCD SHOWS THAT
THE DRIVE BETWEEN THE HIGH SPEED
GEARBOX (HSGB) AND THE INTERNAL
GEARBOX (IGB) IS UNSERVICEABLE
AND :
- AN ENGINE RELIGHT HAS BEEN
TRIED USING THE STARTER
- AN ENGINE GROUND START OR
DRY/WET MOTOR RUN HAS BEEN
TRIED. OIL CAN COLLECT IN THE
HP SHAFT AND CAUSE A FIRE AND
DAMAGE THE ENGINE.
(a) Swarf

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 5 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

1 Unwanted material (swarf) which was


accidentally put into the engine by a machine
when the engine was made, accept it.

(b) Fines

1 Small quantities of magnetic particles which


show as fines (or particles of steel which are
almost the same shape and dimension as hair)
on the probe are not always an indication of
engine failure. They are usually applicable to
engines which have not operated for many
hours since new, repair or overhaul. These
quantities must not be more than a thin cover
on half the MCD probe circumference, accept
them.

2 For quantities which are more than the limit


given above: Install the master MCD and
continue with the inspection of the oil system
Ref. AMM TASK 79-00-00-200-806 and Ref.
AMM TASK 79-00-00-200-804.

(c) Flakes

1 If you find flakes, install the master MCD and


continue with the inspection of the oil system
Ref. AMM TASK 79-00-00-200-806 and Ref.
AMM TASK 79-00-00-200-804.

(d) Chips

1 If you find chips, install the master MCD and


continue with the inspection of the oil system
Ref. AMM TASK 79-00-00-200-806 and Ref.
AMM TASK 79-00-00-200-804.

(5) If the contamination can be accepted as specified above, install


the master MCD Ref. AMM TASK 79-22-46-400-801 and
continue with this procedure.

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 6 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

(6) Keep all metal contamination that is found (accepted


contamination included). This contamination will help you to
keep a record of the type of wear in the engine.

5. Close-up

SUBTASK 79-00-00-410-079-A
A. Close access:
(1) Make sure that the work area is clean and clear of tools and
other items.
(2) Close the MCD access panel:

(a) FOR 4030EM1 (POWERPLANT-DEMOUNTABLE,


ENG 1)
416BR

(b) FOR 4030EM2 (POWERPLANT-DEMOUNTABLE,


ENG 2)
426BR

SUBTASK 79-00-00-865-086-A
B. Remove the SAFETY CLIP - CIRCUIT BREAKER and the tag(s) and
close this (these) circuit breaker(s):

PANEL DESIGNATION FIN LOCATION


FOR FIN 4030EM1(POWERPLANT-DEMOUNTABLE, ENG 1)
722VU FADEC B ENG 1 13KS1 D44
742VU FADEC A ENG 1 12KS1 Q73
FOR FIN 4030EM2(POWERPLANT-DEMOUNTABLE, ENG 2)
722VU FADEC B ENG 2 13KS2 K49
742VU FADEC A ENG 2 12KS2 Q74

SUBTASK 79-00-00-410-071-A
C. Close Access

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 7 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

(1) Close the protective door of the AC/DC emergency power


center 740VU.
(2) Close the access door 811.
(3) Remove the access platform(s).

SUBTASK 79-00-00-862-064-A
D. De-energize the ground service network
Ref. AMM TASK 24-42-00-862-801

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 8 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

Figure 79-00-00-991-01600-22-A (SHEET 1) - Swarf


** ON A/C FSN ALL

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 9 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

Figure 79-00-00-991-01700-22-A (SHEET 1) - Fines


** ON A/C FSN ALL

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 10 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

Figure 79-00-00-991-01800-22-A (SHEET 1) - Flakes


** ON A/C FSN ALL

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 11 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Jan 01/2023

AMM - BOV - A330 TASK:


79-00-00-200-805-A
Tail Number - MSN - TITLE: 79-00-00-06 CONF 22
FSN: 79-00-00-200-805-A - Inspect Master Magnetic Chip Detector
ALL for Evidence of Abnormal Deposits

MECH. INSP.

Figure 79-00-00-991-01900-22-A (SHEET 1) - Chips


** ON A/C FSN ALL
© *** END OF CARD ***

JCP Title: chip detector CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 12 of 12


PRINT DATE: Jan 24/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE

You might also like