Professional Documents
Culture Documents
iAC5000 Series PMP V2
iAC5000 Series PMP V2
imageRUNNER ADVANCE C5051 Series Preventative Maintenance Procedure.
2. Clean Platen Glass and the Platen Reader Glass. Clean the
Platen Slit Glass using FY9‐6020‐000, please refer to TP12 N/A ~15 sec
181.pdf for more details.
3 Remove the ITB Assembly Visually inspect the Laser
3. Remove the ITB Assembly. Visually inspect the Laser
cavity, if there is a lot of toner accumulation clean or
vacuum it. Inspect the patch shutter protect, FC8‐4540‐000.
If it is broken replace it. Inspect/Clean the Image Patch
Sensor. Re‐install the ITB Assembly then perform a
SettingsRegistration>Adjustment/Maintenance>Clean Inside ~2 mins ~3 mins
Main Unit
Main Unit.
4. Clean the Laser slit glass with the cleaning wand and pad.
N/A ~30 sec
5. Check all durable counters for paper feed rollers and
~20 s ~1 min
replace as necessary.
6. Visually Check the Fixing Guide, FC8‐5043‐000, and ensure
that it is not contaminated with hardened toner. If
contaminated / clean.
~20 s ~7 mins
7. Make 12 X 18 Copies using Heavy 1,2, or 3 setting and
check for lines on the border of the copies. Diagnose if
~30 secs N/A
Drum or Developer Housing needs to be replaced. If Drums
are over 100% replace them.
8. Visually check the Manual Bypass sensor, if the sensor has
a black connector replace it with the white one, WG8‐5783‐
000. ~15 secs ~5 mins
T t l
Total ~3 i
~ 3 mins ~ 17 mins
~ 17 i