Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Lighting the way

with diagnostics

Fully Automated Coagulation Analyser


CS-1600

The Sysmex CS-1600 system is a fully automated coagulation analyser


that is ideal for mid-sized coagulation laboratories requiring an easy-to-
use, cap-piercing analyser capable of running clotting, chromogenic, and
immunologic assays simultaneously.

Using novel technologies, the CS-1600 assured laboratories of consistent


accuracy & reliability in their testing results. In addition, there are various
high-end functionalities aimed at helping laboratory operators improve their
work efficiency, and providing extra support to laboratory accreditation
requirements and operations.

Reagent Test Menu


PT Dade Innovin, Thromborel S

Design and specifications may be subject to change due to further product development.
APTT Dade Actin, Dade Actin FS, Dade Actin FSL, Pathromtin SL
Fibrinogen Dade Thrombin, Dade Fibrinogen Determination Reagent
Thrombin Time Test Thrombin, Thromboclotin
Batroxobin Time Batroxobin
Factor Deficiency Factor II, V, VII, VIII, IX, X, XI, XII
Lupus Anticoagulant LA1 screen, LA2 confirmation
Protein C Pathway ProC Global, Protein C Reagent, Berichrom Protein C, Protein S Ac,
Innovance Free Protein S
Antithrombin Innovance Antithrombin, Berichrom Antithrombin III (A)
D-Dimer Innovance D-Dimer
Von Willebrand Factor vWF Ag, Innovance vWF Ac
Chromogenic Factor VIII Chromogenic, Berichrom C-1 Inhibitor,
Berichrom α2-Antiplasmin, Berichrom Plasminogen

Sysmex Asia Pacific Pte Ltd Sysmex New Zealand Ltd Sysmex Vietnam Co., Ltd
Tel +65 6221-3629 Fax +65 6221-3687 Tel +64 (9) 630-3554 Tel +84 (8) 3997-9400 Fax +84 (8) 3997-9405
www.sysmex-ap.com www.sysmex.co.nz www.sysmex.com.vn

Sysmex India Pvt. Ltd Sysmex (Thailand) Co., Ltd Sysmex Vietnam Co., Ltd (Hanoi Branch)
Tel +91 (22) 6112-6666 Tel +66 (2) 032-2536 Fax +66 (2) 116-5396 Tel +84 (4) 3776-7020 Fax +84 (4) 3776-7022
www.sysmex.co.in www.sysmex.co.th www.sysmex.com.vn

PT Sysmex Indonesia Sysmex Philippines Inc. Sysmex Australia Pty Ltd


Tel +62 (21) 3002-6688 Fax +62 (21) 3002-6699 Tel +63 (2) 621-2460 Fax +63 (2) 621-2432 Tel +61 (2) 9016-3040
www.sysmex.co.id www.sysmex.com.ph www.sysmex.com.au

Sysmex (Malaysia) Sdn Bhd


Tel +60 (3) 5637-1788 Fax +60 (3) 5637-1688
www.sysmex.com.my
SAP/HEMOSTASIS/CS-1600SPECS/05052019/v2.0

1
Specifications

Measurement Quality Control


Principle Multi-Wave Detection System: Method X-bar control, Levy-Jennings control
Transmitted Light Detection Method Multi-rule (Westgard Rule) monitoring

Clotting Assays: File Capacity 300 data points x 40 files in memory


405, 660, 800 nm (Percentage Detection Method)

Chromogenic Assays:
405 nm (Rate Method) Calibration
Multi Lot Reagent Management Max. 5 reference curves per lot
Immunoassays:
Max. 5 lots per parameter
575, 660, 800 nm (Rate Method, VLIn Method)
Dilution Points 2-9
Configuration CS-1600 Cap-piercing Model
Detector 8 channels for clotting assays, chromogenic assays and immunoassays
The transmitted light (or A/D value) is detected every 0.1 seconds Data Management
Maximum reading time is 1800 seconds
Memory Capacity 3,000 sample results with reaction curves
Throughput PT: 120 test/h
Output Graphic or Data Printer (optional)
PT/APTT: 110 test/h
PT/APTT/Fbg/DD: 70 test/h
Random Access 20 simultaneous parameters
Software
IPU McAfee Embedded Security provided
Host Communication Interface CA-500/1500 format, CS format, Coagrex800 format, ASTM format
Sample Handling
Host Connection Bi-directional RS-232C serial port or via Ethernet-TCP/IP
Type of Sample Primary tubes and sample cups
Operating System Windows-based
Barcode Identification Automatic positive sample identification
Handling Handle racks with a mixture of closed and open tubes, and sample cups
Capacity Continuous loading of maximum 5 racks of 10 tubes each Power Supply
STAT STAT sample can be analysed as priority by executing either sample or Operating Voltage 100 – 240V
rack interruption
Consumption 680 VA max
Aspiration The sample probe, with a liquid surface sensor, quantitatively aspirates
Frequency 50 or 60 Hz
plasma from centrifuged whole blood samples

Dimensions and Weight


Reagent and Consumable Handling
Main Unit Approx. 760(W) × 690 (D) × 540 (H) mm,
Reagent holder 28 reagent vial positions (15°C); 12 positions are tilted at 10° to reduce dead Approx. 85 kg
volume
5 positions (room temperature)
Barcode Identification External 2-D handheld barcode reader for positive reagent identification; type, Operating Environment
lot number, expiry, and calibrators, controls and reagents’ assay values input Ambient Temperature 15 - 30°C
Handling Mixture of different vial types with use of various adaptors Relative Humidity 30 - 85%
Monitoring Real-time monitoring of on-board stability, remaining volume/tests Heat Compensation Approx. 2,205 BTU/h
Reaction tubes Automatically supplied from an internal hopper (556 kcal/h)
Continuous loading of max. 300 tubes Noise Level During Analysis 60 dB or less

1 2
Lighting the way
with diagnostics

Fully Automated Coagulation Analyser

CS-1600

Novel technologies.
Assuring results.

Design and specifications may be subject to change due to further product development.

Sysmex Asia Pacific Pte Ltd Sysmex New Zealand Ltd Sysmex Vietnam Co., Ltd
Tel +65 6221-3629 Fax +65 6221-3687 Tel +64 (9) 630-3554 Tel +84 (8) 3997-9400 Fax +84 (8) 3997-9405
www.sysmex-ap.com www.sysmex.co.nz www.sysmex.com.vn

Sysmex India Pvt. Ltd Sysmex (Thailand) Co., Ltd Sysmex Vietnam Co., Ltd (Hanoi Branch)
Tel +91 (22) 6112-6666 Tel +66 (2) 032-2536 Fax +66 (2) 116-5396 Tel +84 (4) 3776-7020 Fax +84 (4) 3776-7022
www.sysmex.co.in www.sysmex.co.th www.sysmex.com.vn

PT Sysmex Indonesia Sysmex Philippines Inc. Sysmex Australia Pty Ltd


Tel +62 (21) 3002-6688 Fax +62 (21) 3002-6699 Tel +63 (2) 621-2460 Fax +63 (2) 621-2432 Tel +61 (2) 9016-3040
www.sysmex.co.id www.sysmex.com.ph www.sysmex.com.au

Sysmex (Malaysia) Sdn Bhd


Tel +60 (3) 5637-1788 Fax +60 (3) 5637-1688
www.sysmex.com.my
SAP/HAEMOSTASIS/CS-1600/29042019/V3.0
www.sysmex-ap.com
CS-1600

Novel technologies
Assuring consistently accurate and reliable results on every test run

Sysmex aims to bring cutting edge technology to every laboratory. The CS-1600 system is a further evolution of the
CS-series; utilising the proprietary multi-wavelength detection system to deliver consistently accurate and reliable
results to laboratories.

Photo diode 405nm The CS-1600 is equipped with an optical fibre that
575nm supplies light at 4 different wavelengths, and a detector
660nm capable of receiving light in multiple wavelengths.
Lamp unit 800nm
This is the Sysmex proprietary multi-wavelength Reliable cap-piercing system Primary sample volume check
detection system. It allows measurement of • Sysmex has accumulated more than 20 years of • When aspirating a sample for the first time, the
multiple parameters with varying methodologies experience in developing cap-piercing systems that system detects the level of liquid in the sample tube.
simultaneously. Throughput is improved as the time to are safe and highly reliable. It then determines whether or not it contains an
Multi-wavelength filter Optical fibre measure a single sample is reduced. appropriate volume of blood according to the CLSI
• This prevents sample contamination and deliver
guideline of 9:1 ratio.
accurate results.
• Sample tubes with volumes outside the acceptable
range are flagged to avoid reporting of erroneous
The power of multi-wavelength technology results.
Signal
Chromogenic assay Lipids
Haemoglobin 1,200
Clotting assay
Chromogenic assay Bilirubin
Immunologic assay
Absorbance

Clotting assay
Immunologic assay Secondary wavelength (800nm)
Clotting assay 800
Immunologic assay
Aggregation assay

Primary wavelength
400
(660nm)

300 350 400 450 500 550 600 650 700 750 800 850
turbidity level over threshold
Wavelength (nm) Blood/
Spectra of interfering substances anticoagulant
0 10 20 30 40 50
Seconds ratio 9:1
Normal reaction curve
• Reduces the effect of interfering substances on the
absorbance spectra by utilising optimal wavelengths.
Signal
• Optimal wavelength is automatically selected based 1,200
on the sample characteristics (wavelength switching)
for more accurate results.
• Switches automatically to the secondary wavelength 800

when the coagulation reaction shows only a small


change at the primary wavelength. Such as in the Secondary wavelength
400 (800nm)
case of a severely lipemic or low fibrinogen sample.
Switching
Primary wavelength (660nm)
turbidity level over threshold

0 10 20 30 40 50
Seconds
Abnormal reaction curve

Wavelength switching during PT measurement


CS-1600

User-friendly functions
Improving operational efficiency for you

The CS-1600 system aims to help laboratories manage their workflow easily and efficiently. Easy-to-read reagent display screen
• Complete on-board reagent status information with
supporting graphics and data to help you manage
Safe & flexible sample aspiration your daily reagent use.
• The system can handle various types of blood
collection tubes. It automatically detects the On-board stability time
presence of a cap, enabling measurement, even when
capped and uncapped collection tubes are placed on
the same rack.
• This reduces your sample processing time.

Flexible STAT analysis


Remaining volume/number of tests
• STAT samples are given priority by enabling flexible
and easy interruption through “sample” or “rack”
interruption method.
• On-screen animation is available to guide you
through the process.
3 status indicators to let you know when it is time to change the reagent

Auto starts and backup A thoughtful design

More reagent caps More reagent caps


storage area storage area

Reagent caps storage area

• Allows you to prepare the analyser for standby mode • Automatically take cares of your data preservation
at the designated dates and times. for you by performing auto backup function at the
scheduled time or at the time of shutdown.

Tilted reagent vial positions to reduce reagent wastage


CS-1600

Sophisticated software
Supporting your laboratory accreditation requirements and
operations
Thanks to the sophisticated software used, the CS-1600 system offers extra support to laboratories in meeting
their accreditation requirements and daily operation needs.

Traceability of results/operation log Handover


• This dedicated accreditation feature allows you to With just one screen, you can check the remaining
trace the measurement results, reagent lot number, reagents and consumables level, maintenance status
calibration curve used in testing, and the date/ and error information easily and quickly, and prepare
time of the recent QC measurement as well as the the analyser accordingly before handling over to the
operation easily. next shift.

You might also like