FEED GAS FLOW

At feed gas flow rates within the minimum and maximum capacity (35%-100%), all PSA
parameters are adjusted automatically by the CAPACITY & TIMING CONTROL in order to
maintain the product purity and hydrogen recovery rate. No intervention by operator is
necessary. Beyond these limits, adsorbent material can be damaged and product purity and H 2-
recovery are affected.

OpFac < 1 For increased content of impurities in feed gas or for low product purity; results in:
- shorted up PSA timing
- shorter adsorption time
- increasing the product purity

PROCEDURE: INCREASE OPERATION FACTOR TO IMPROVE PRODUCT RECOVERY

1. lncrease OpFac by 0.01


2. Wait three complete PSA-cycles
3. Repeat increasing OpFac until product purity begins to drop
4. Decrease OpFac by 0.02 to adjust safe operation at highest recovery
5. Wait three complete PSA-cycles and confirm that the purity remains unchanged

The sequence control on PSA unit is executed by the control system and does not require any
operator access. In general at design feed gas composition results in design product purity.

The timing of the PSA unit must be adjusted manually, whenever the product purity is out of the
target range.

OPERATION OF PSA UNIT

OpFac = 1 For design conditions, the timing is equal to design figures


OpFac > 1 For decreased content of impurities in feed gas or for high product purity; results in:
- extended PSA timing
- longer adsorption time
- decreasing the product purity
- increasing the recovery

PROCEDURE: DECREASE OPERATION FACTOR TO IMPROVE PRODUCT PURITY

1. Decrease OpFac by 0.05


2. Wait three complete PSA-cycles
3. Repeat decreasing until the desired product purity has been reached

Product purity has to be adjusted according to the requirements of the H 2 consumers or


according to the minimum requirements of PSA operation, whatever requirement is higher.
Keep in mind that higher product purity will result in a lower hydrogen recovery and vice versa.
4. lncrease OpFac by 0.03
5. Wait three complete PSA-cycles and confirm that the purity remains unchanged
6. To adjust safe and stable conditions decrease OpFac by 0.03