Master Information Block (MIB)

System Scheduling Block 1 (SB1)


System Information Block 1 (SIB1)
System Information Block 2 (SIB 2)

System Information Block 3 (SIB 3)


System Information Block 5 (SIB 5)
System Information Block 7 (SIB 7)

System Information Block 11(SIB 11)


value=hex2dec(5)=5 , hex2dec(2)=2 ,hex2dec(0)=0 --> MCC=520

value=hex2dec(0)=0 , hex2dec(1)=1 --> MNC=01


>>Paging Procedure and Parameters Description (Module II)
value=3000ms
value=3
value=40ms
value=40ms
value=0
value=250ms

value=6s
value=50
value=20s
value=30s
value=infinity

value=2000ms
value=3

value=6s
value=1

value=hex2dec(0065)=101

Cell Identity=RNCid(12bits)+Cellid(16bits)
value=0000000010110111011110010010 => RNCid=bin2dec(000000001011)=11 and Cellid=bin2dec(0111011110010010)=30610

>>>Cell Selection and Reselection Algorithm and parameters description (Module II)
value=2dB(step of 2 dB)

value=10dB(step of 2 dB)
value=8dB(step of 2 dB)

value=4dB(step of 2 dB)

value=-18dBm

value= ((-58*2)+1)= –115 dBm e.g. –57 means –113 dBm; …; –13 means -25 dBm
value=4dB(step of 2 dB)

value=1s(step of 1s)

value=24dBm
>>>Cell Access Restriction parameters description (Module II)

>>>Cell Channel Power Configuration Parameters (Module II)

value=-7dB (relative to the PCPICH)

value=-6dB (relative to the PCPICH)


>>>Access Precedures and parameters description (Module II)
>>>Open Loop Power Control Algorithm and parameters description (Module II)

value=33dBm

value=-20dBm
value=2dB(step of 1 dB)

value=20attempts

value=8attempts

value=
value=-105dBm

>>>see "Parameters description"

Value= InterFreqMeasurement is unavailable


Value= IntraFreqMeasurement is based on CPICH Ec/No

>>> IntrafreqMeasurement description (Module II)

value=hex2dec(3b)=59 (Serving Cell's Primary Scrambling Code)

value=hex2dec(43)=67(Neighbour Cell's Primary Scrambling Code)


Value= InterRATMeasurement

value=0dB

value= ((-50*2)+1)= –99 dBm e.g. –57 means –113 dBm; …; –13 means -25 dBm

value=BSIC=32

value=GSM1800

value=BCCH=516
c(0111011110010010)=30610