CCC PC-16

APRIL 2018

CONVEYOR SAFETY

PC-STOP
CONTROL
CABLE OPERATED CONVEYOR SAFETY PC-STOP SWITCH
IS THE FINEST SWITCH OF IT’S KIND — RUGGED
CONSTRUCTION WITHSTANDS THE HARDEST USAGE.

Division of Material Control, Inc.


Croswell, Michigan 48422 • U.S.A.
OPERATION INFORMATION: INSTALLATION INSTRUCTIONS
1. Control should be mounted on
a flat surface using mounting plate
provided.
2. Distance between switches
should not exceed 200’. Use no
more than 100’ of cable per switch
end. This is for safety purposes,
too much cable can result in a “long
pull” situation due to slackness in
the cable.
OPTIONAL WARNING LIGHT: RED POWDER COATED
RED LIGHT CAN BE EASILY FLAG ARM — HEAVY 3. Space cable support eye bolts
SEEN IN DARK SITUATIONS DUTY (NORMAL POSITION) every 10 feet. Keep cable from
becoming too slack, also not too
CABLE END 20 AMP 480V AC SP/DT MOUNTING PLATE taught as to pull out the cable
CONTACTS (STANDARD)
CONNECTION end clevis.
CLEVIS
RUGGED TORSION 4. Shutdown controls should be
SPRING FOR
POSITIVE ACTUATION wired through the motor control
OF FLAG ARM circuit, not directly to motor power.
5. After applying power, actuate by
pulling cable to check switch. This
will ensure that there is not too
much slack in the cable and that
there are no obstructions in the
cable or flag arm.
STAINLESS
STEEL
BUSHING
REMOVAL OF THE COVER PLATE
CAST EXPOSES SWITCH TERMINALS.
ALUMINUM AMPLE ROOM FOR WIRING.
HOUSING.
ALSO
AVAILABLE
WITH
CORROSION
RESISTANT
STAINLESS STEEL
EPOXY COATING. SHAFT AND
RETAINING RING
1” CONDUIT OPENING
CUTAWAY VIEW

WIRING INFORMATION
STANDARD SWITCH – One SP/DT switch per end (two switches per end available) OPTIONAL SWITCH – One two-circuit double break switch per end (two switches
• 20 AMPS, 125, 250 or 480 VAC • 10 AMPS, 125 VAC “L” (tungsten lamp load) per end available.) • 15 AMPS, 120, 240, 480 or 600 VAC • 1/2 HP, 120 VAC
• 1 HP, 125 VAC • 2 HP, 250 VAC • 1/2 AMP, 125 VDC • 1/4 amp, 250 VDC • 1 HP, 240 VAC • 0.8 AMPS, 115 VDC • 0.4 AMP, 230 VDC
3A 4A
N.C.
SINGLE POLE, DOUBLE THROW CIRCUIT TWO CIRCUIT, DOUBLE BREAK CIRCUIT N.O.
1B 2B

L1 L2 PULL CORD L1 L2 PULL CORD L L PULL CORD L1 L2 PULL CORD NOTE: Two circuit double break
LIGHT
SWITCH SWITCH 1 2 SWITCH LIGHT SWITCH
switches must be wired to equal
MOTOR OR MOTOR OR voltage sources and the same
STARTER c
ALARM
c
n.o STARTER 3a
4a ALARM
1b
n.c 2b polarity. Loads should be on the
COIL HORN COIL HORN same side of the lines. 1B has the
MOTOR CONTROL CIRCUIT WARNING CIRCUIT MOTOR CONTROL CIRCUIT WARNING CIRCUIT same polarity as 3A.

5-29/32”
[150 mm]
7”
1” [25 mm] [178 mm]
NPT CONDUIT
13/32” [10 mm]
FLAG ARM DIA. HOLES C/L OF HOUSING AND
FLAG ARM (TRIPPED POSITION) CONDUIT OPENING
(NORMAL POSITION)
16# PULL
FIELD
ADJUSTABLE
[76 mm]

[126 mm]
4-15/16”
3”
[70 mm]

[76 mm]
2-3/4”

3”

3/4”
C/L OF HOUSING AND [19 mm]
CONDUIT OPENINGS CONDUIT ENTRY
3-7/16” 7-3/4” 3-1/4” 1” - 11½ N.P.T. 3/4”
[87 mm] [197 mm] [83 mm] 3/8” [19 mm]
5” 2-7/8” [10 mm]
[127 mm] [73 mm] 1-1/4”
[32 mm]
FRONT VIEW (DOUBLE END UNIT) SIDE VIEW
MOUNTING PLATE
2 conveyorcomponents.com Conveyor Components Company • 800-233-3233 • Fax: 810-679-4510 • info@conveyorcomponents.com
Eyebolts
LEFT 10’ SPACING
HAND
PCL-1S PCR-1S PCL-1S

RIGHT
HAND
PCR-1S Cable ends Cable ends

100’ 100’ 100’ 100’


MAXIMUM MAXIMUM MAXIMUM MAXIMUM

TECHNICAL INFORMATION
UL/CSA certified enclosure sealed for outside applications • Standard unit meets
NEMA Type 1,3,4,4X and 12 requirements • Housing: cast aluminum
• Flag arm: steel with red powder coating

SELECTION AND MODEL INFORMATION


1-SINGLE POLE: 1-TWO CIRCUIT: 1-SINGLE POLE: 1-TWO CIRCUIT:
double throw microswitch double break microswitch for double throw microswitch at double break microswitch for
PCL-1S ................. LEFT HAND D.C. circuits each end D.C. circuits
PCR-1S ..............RIGHT HAND PCL-1T ................. LEFT HAND PCD-2S ........DOUBLE ENDED PCD-2T.........DOUBLE ENDED
TYPICAL USE: PCR-1T...............RIGHT HAND TYPICAL USE: TYPICAL USE:
Emergency shutdown of TYPICAL USE: Emergency shutdown of Emergency shutdown of
conveyors or other machinery. Emergency shutdown of conveyors or other machinery. conveyors or other machinery.
conveyors or other machinery.

AVAILABLE OPTIONS:
Explosion-Proof for Hazardous locations • Epoxy Coating for Corrosive locations

2-SINGLE POLE: 2-TWO CIRCUIT: 2-SINGLE POLE: 2-TWO CIRCUIT:


double throw microswitch double break microswitch for double throw microswitch at double break microswitch at
PCL-2S ................. LEFT HAND D.C. circuits each end each end for D.C. circuits
PCR-2S ..............RIGHT HAND PCL-2T ................. LEFT HAND PCD-4S ........DOUBLE ENDED PCD-4T.........DOUBLE ENDED
TYPICAL USE: PCR-2T...............RIGHT HAND TYPICAL USE: TYPICAL USE:
Emergency shutdown of TYPICAL USE: Emergency shutdown of Emergency shutdown of
conveyors or other machinery Emergency shutdown of conveyors or other machinery conveyors or other machinery
– with alarm or secondary conveyors or other machinery – with alarm or secondary – with alarm or secondary
function capability. – with alarm or secondary function capability. function capability.
function capability.

AVAILABLE OPTIONS:
Explosion-Proof for Hazardous locations • Epoxy Coating for Corrosive locations • Optional Light for Remote or dark locations

SPECIAL APPLICATION OPTIONS ACCESSORIES


HAZARDOUS LOCATIONS: CABLE SUPPORT EYE BOLT THREADLESS CABLE
UL/CSA explosion proof units meet NEMA Type 7 – Class 1 (Div. 1 & 2), 1” eye x 6” zinc plated. SUPPORT EYE BOLT
½”-13 x 2½” thread. RS-23
Groups C and D, NEMA Type 9 – Class II (Div. 1 & 2), Groups E, Includes two nuts and
F and G for hazardous locations. Add “X” to model number, one lockwasher.
NO ADDITIONAL CHARGE. PC-27

ALTERNATE CONSTRUCTION:
CABLE END FITTING SAFETY CABLE
Dual rated enclosure NEMA type 4, 4X & NEMA type 9 – Class II Forged steel saddle and steel 3/32” x 7x7 preformed,
(Div. 1 & 2), Groups E, F and G for hazardous locations, with O-ring U-bolt. Galvanized. galvanized aircraft cable.
Available with either orange
gaskets. Add “D” to end of model number. PC-28
vinyl or orange nylon
protective coating.
CORROSIVE LOCATIONS: 3/16” O.D.
Epoxy coated housing with standard flag arms and plated torsion Vinyl Coated PC-25
Nylon Coated PC-26
springs. Add “E” to model number.
REMOTE OR DARK LOCATIONS: CONDUIT PLUG PC MOUNTING
Use our red warning light in dark and remote areas (requires two 1” metal. BRACKET
microswitches per end of housing). 125 VAC. (incandescent) PC-29 PC-29X PC-30
NOTE: Available in rain tight, dust tight and explosion proof.
Add suffix “L” to model number.
125 VAC LED lamp available by special order.

Conveyor Components Company • 800-233-3233 • Fax: 810-679-4510 • info@conveyorcomponents.com • conveyorcomponents.com 3


CONVEYOR SAFETY

PC-STOP
CONTROL
for immediate positive
shutdown of equipment

The PC Stop Control can be used for emergency


shutdown of conveyor systems, elevator equipment,
bulk handling systems, cranes, production and assembly
lines, or any other equipment which may require
immediate, positive shutdown.

SEE OUR OTHER BULLETINS FOR ADDITIONAL


PRODUCTS TO KEEP YOUR CONVEYOR
OPERATING SMOOTHLY

We Accept:

130 Seltzer Road • PO Box 167 • Croswell, MI 48422


www.conveyorcomponents.com • info@conveyorcomponents.com
Phone: 800-233-3233 Fax: 810-679-4510
© Copyright 2015
Effective February, 2015
F.O.B Croswell, Michigan • Terms: Net 30 days, Tax not included • Prices subject to change without notice

You might also like