Professional Documents
Culture Documents
Clivet-2003-1C Air Cooled Module Chiller and Mini Chiller-H3326 - WCAN WGAN
Clivet-2003-1C Air Cooled Module Chiller and Mini Chiller-H3326 - WCAN WGAN
Clivet-2003-1C2004
CLIVET SPA
Via Camp Lonc 25, Z.I. Villapaiera - 32032 Feltre (BL) - Italy
Tel. + 39 0439 3131 - Fax + 39 0439 313300 - info@clivet.it
CLIVET RUSSIA
Elektrozavodskaya st. 24, office 509 - 107023, Moscow, Russia
Tel. + 74956462009 - Fax + 74956462009 - info.ru@clivet.com
A Group Company of
Always ready for the Future Clivet. Change things
40 75 2016
agencies in Italy
630 countries we export to
A Group Company of
employees in Italy
and abroad
2015
Clivet Live is born
50.000 m² 6 Midea Group
FORTUNE GLOBAL 500
#323 in 2018
of plants in Feltre,
Belluno - Italy branches: Great Britain, Germany, Spain, 140
service centres 39.5 $M
Russia, UAE, India Midea turnover
01 02
Contents
03 04
Features
ELFOEnergy Spark Chillers with cooling capacity ranging from 180kW to 250kW, combination model’s maximum capacity ups
to 2000kW.
Max 8 modules
ELFOEnergy Spark SERIES
Freely combine with fan coil units and air handling units. Project owners may choose the best types according to their design
taste (for interior) or functional needs.
Cassette type
Duct type
ELFOEnergy Spark SERIES Wide ambient temperature and water outlet temperature operation ranges
60°C
Cooling
52°C Cooling 70°C
-10°C 5°C
SS 380V/3N/50Hz 180kW / 250kW -10°C -10°C
-10°C
-20°C 0°C
0°C
SS-LA 380V/3N/50Hz / 200kW / -25°C
SS: Standard Spark Series Ambient temperature operation range Water outlet temperature operation range
SS-LA: Spark Series with low ambient temperature cooling function
05 06
ADVANCED TECHNOLOGY HIGH RELIABILITY
Original design
ELFOEnergy Spark SERIES
The new designed window fins enlarge the heat-exchanging area, decrease the air resistance, save more power and enhance heat 1
1 ……
2
5
exchange performance. 3
6
4
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency. ……
7
8
The specially coated blue fins enhance durability and protect against corrosion from air, water and other corrosive agents, assures 8
Back-up functions
In a combination system, if one module failed, other modules can be back-up instead of the failed one for continuing operation.
Master Slave
Water dead zone
Flat baffle plate
Refrigerant outlet
For shell-tube heat exchanger, the module adopts the new helical baffle design to avoid the rectangular place of water dead
zone, greatly improve the heat exchange efficiency.
100% High/low pressure Power phases Evaporator low temperature System anti-freezing Frequently ON/OFF
protection of sequence protection protection in cooling protection in winter protection of compressor
75% compressor
50%
25%
Over-current Air discharge temperature System high temperature Water flow protection Sensor malfunction
0%
protection protection of compressor protection protection
of compressor
07 08
Intelligent defrosting technology Modbus function
Max. 16 wired
controllers (P Q E) Max. 8 units
ELFOEnergy Spark SERIES
(X Y E)(Modbus protocol)
(P Q E) Max. 8 units
T min Time
saving
Time
7 minutes less!
EASY CONTROL
Computer
Touch key wire controller as standard accessory to control the chillers.
Appearance
09 10
Specifications Dimensions (Unit:mm)
Model WCAN-XTP 200.6T WCAN-XTP 180.6T WCAN-XTP 250.8T
Series PS-LA PS PS
WCAN-XTP 180.6T
Power supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 WCAN-XTP 200.6T
Capacity kW 185 180 250
Cooling 1
Input kW 63.0 57.9 78.3
C
Capacity kW 200 195 270 B
Heating 3 Input kW 61.0 59.4 80.0
E
Max. running current A 150 155.1 200.0
C
Charged volume kg 42.0 39.0 60.0
Refrigerant
Throttle type EXV EXV EXV
E
Sound pressurer level 4
dB(A) 74 74 74
Note:
1. Cooling: Water inlet/outlet: 12°C / 7°C, outdoor ambient temp. of 35°C DB.
2. Cooling: Water inlet/outlet: 12°C / 7°C, outdoor ambient temp. of 46°C DB.
3. Heating: Water inlet/outlet: 40°C/ 45°C, outdoor ambient temp. 7°C DB/6°C WB.
4. 1m away in open field.
5. The data is for low water outlet temperature function. Under the using condition of this function, the system must be added antifreeze agent.
11 12
Features
WIDE APPLICATION RANGE
ELFOEnergy Nova chillers with cooling capacity ranging from 35kW to130kW, combination model’s maximum capacity ups to
2080kW.
Freely combine with fan oil units and air handling units. Home owners may choose the best types according to their functional
needs.
ELFOEnergy Nova Series
20°C 30°C
Series Cooling
10°C 20°C 25°C 17°C
-10°C 5°C
-10°C
NS-LA: Nova series with low ambient temperature cooling function -15°C
-20°C 0°C
0°C
-25°C
13 14
ADVANCED TECHNOLOGY EXV for more precisely flow control
Patented liquid distribution components to maximize performance and minimize defrost impact.
H shape high performance heat exchanger 500 steps EXV plus capillary for stable and accurate gas flow control.
The chillers use new structure design, H shape condenser, 360°air intake, increase the heat exchanging area, efficiently enhance Fast respond resulting in higher efficiency and improved reliability.
the heat exchange efficiency, and decrease the covering area.
100%
75%
50%
25%
0%
Removable panel
Easy to maintain 3 Inner-threaded copper pipe
Anti-corrosion materials
Transportation hole
Easy to install 4
5 Multi folder frame
Nice and strong
Inner grooved copper pipe, increase area of heat exchanger, improve efficient.
Anti-corrosion shell increases the useful life of heat exchanger.
H shape condenser uses inner grooved copper tube and hydrophilic aluminum foil, greatly improve the heat exchange efficiency.
Chilled water inlet
Refrigerant inlet
Helical baffle
Original design
For shell-tube heat exchanger, the module adopts the new helical baffle design to avoid the rectangular place of water dead
New design High efficiency inner-threaded pipe, Hydrophilic fins + inner-threaded pipes
enhance heat transfer. zone, greatly improve the heat exchange efficiency.
The new designed window fins enlarge the heat-exchanging area, decrease the air resistance, save more power and enhance
heat exchange performance.
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.
The specially coated blue fins enhance durability and protect against corrosion from air, water and other corrosive agents, assures
a longer coil service life.
15 16
HIGH RELIABILITY Intelligent defrosting technology
Model alternative defrosting technology ensures little fluctuation on water temperature.
Alternative cycle duty operation Manual defrosting program is available for service purpose.
In one combination module, all slave units operate as alternative in cycle duty to keep equal running time, realize higher stability,
Traditional defrosting
better reliability and longer lifespan. Clivet Fast Defrosting
For example, 16 modules combination, no.1 is master unit, others are slave units.
Heating capacity
T min Time
saving
1
1 …… Time
2
13 7 minutes less!
3
14
4 ……
16
15 FLEXIBLE INSTALLATION
16
EXV 7
500 steps
Control box
Easy to maintain
Helical baffle
Efficiency increase 10%
6
2
Master Slave Multi folder frame
Low vibration. 5
Durable and stable Scroll compressor
3 High efficiency
4 Low noise
Reliable protections
High/low pressure Power phases Evaporator low temperature System anti-freezing Frequently ON/OFF
protection of sequence protection protection in cooling protection in winter protection of compressor
compressor
Over-current Discharge temperature System high temperature Water flow protection Sensor malfunction
protection protection of compressor protection protection
of compressor
17 18
EASY CONTROL Modbus function
Touch key wire controller as standard accessory to control the chillers. Modbus is an open protocol that is widely used, especially in BMS building control systems. Modbus function can be customized
by adding X, Y, E ports on wired controller KJRM-120D/BMK-E. It can connect Max. 16 wired controllers and each controller can
control Max. 16 units.
Max. 16 wired
controllers (P Q E) Max. 16 units
(X Y E)(Modbus protocol)
(P Q E) Max. 16 units
Computer
ELFOEnergy Nova Series
Appearance
Note: When use the remote control function, the wired controller will be invalid for ON/OFF and mode selection.
19 20
Specifications Dimensions (Unit:mm)
Capacity kW 35 65 80 130
Capacity kW 37 69 85 138 D F
C
Heating 2
Input kW 11.3 21.5 26.5 43
E
Compressor
E
Quantity Pieces 1 1 2 2
B
Water side heat Water pressure drop kPa 55 30 30 40
B
exchanger
Volume L 10 35 47.5 60
C
Controller Wired controller Wired controller Wired controller Wired controller
B
Cooling °C -10~46 -10~46 -10~46 -10~46
Ambient temperature
range Heating °C -15~24 -15~24 -15~24 -15~24 D F
A
Water outlet Cooling °C 5~17 5~17 5~17 5~17
temperature range Heating E
°C 40~50 40~50 40~50 40~50
Cooling °C 0~17 0~17 0~17 0~17
Water outlet
temperature range4 Heating Model A B C D E F
°C 25~50 25~50 25~50 25~50
21 22
High Efficiency
A++ RATED ENERGY EFFICIENCY
ELFOEnergy Tempo Nova II Series DC inverter air-cooled chillers are compliant with the EU’s Energy-Related Products Directive
(2009/125/EC) and all have A++ or A+ seasonal space heating energy efficiency ratings.
COMPRESSOR
At the heart of the chiller lies a world-leading DC inverter compressor. The compressor’s innovative design and numerous high
performance features reduce power consumption by 25%.
ELFOEnergy Nova II Series
Product lineup
Capacity(kW) 30 60 90 Compressor for WCAN-XSi 14.1, WCAN-XSi 22.2
Appearance
Advanced permanent
magnet DC motor improves low
Specially designed
frequency band performance
scroll profile for R410A
380-415V/3Ph/50Hz
23 24
DC FAN MOTORS HIGH EFFICIENCY PLATE HEAT EXCHANGER
Fan speed is controlled according to the system pressure and system load, reducing power consumption by 30%.There are Plate heat exchanger uses metal plates to transfer heat between refrigerant and water. The fluids are exposed to a much larger
32-step vector control for Nova Ⅱ models. surface area because the fluids spread out over the plates, so both heat transfer efficiency and heat exchanger speed are greatly
improved. Multi protections including voltage protection, current protection, anti-freezing protection and water flow protection
ensure system safety running.
Refrigerant inlet
Low
Water inlet
HIGH PERFORMANCE HEAT EXCHANGER
Refrigerant outlet
For WCAN-XSi 35.2, plate heat exchanger as a secondary intercooler boosts up refrigerant subcooling and
improves 10% energy efficiency.
Original design
New design High efficiency inner-threaded pipe, Hydrophilic fins + inner-threaded pipes
enhance heat transfer.
Chillers use new structure design "I shape" condenser. The manufacturing process of Ⅰshape heat exchanger is simple, which
ELFOEnergy Nova II Series
Patented liquid distribution components maximize performance and minimize impact of defrosting operation. 500-step EXV with
capillary tube allows stable and accurate gas flow control. Fast response results in higher efficiency and improved reliability.
100%
75%
50%
25%
Efficient fan motor, well-designed air duct and uniform wind field make heat exchange of the whole system more thorough.
0%
25 26
Wide Application Range Advanced Technology
Modular design allows up to 16 units to be connected together, giving a system cooling/heating capacity range of 30kW to Loading and offloading for multiple units system
1440kW.
1
1 ……
2
13
3
14
4 ……
15
Compatible with fan coil units and air handling units. 16
16
BACK UP
Wall-mounted Ducts
In a multi-unit system, if one module fails, the other modules provide backup so that the system can continue operating.
4
……
16
Thanks to the vapor injection DC inverter compressor, the WCAN-XSi 35.2 can run heating mode stably down to -20 ° C, and
AMBIENT TEMPERATURE OUTLET WATER TEMPERATURE
the heating capacity can be improved greatly.
Stable operation even under extreme conditions: -20°C to Wide outlet water temperature range with lowest outlet
43°C. temperature in cooling mode of 5°C.
27 28
REFRIGERANT COOLING PCB RAPID COOLING OR HEATING
The DC inverter compressor reaches full capacity rapidly, providing quicker cooling or heating with lower levels of temperature
WCAN-XSi 35.2 uses refrigerant cooling technology to cool the electric control box. It decreases the average temperature
fluctuation during the cooling/heating operation.
of electrical control components by about 8 degrees, guaranteeing the stable and safe running of the control system.
1 2
Time
Enhanced Comfort
Cooling operation Inverter Non-Inverter
Different silent modes enable noise reduction to suit time of day and ambient noise levels.
TEMPERATURE COMPENSATION
Weather dependent operation with climate correlation to ensure absolute comfort. Once parameters are selected, the unit set
the outlet water temperature automatically according to the outdoor ambient temperature.
ELFOEnergy Nova II Series
T2
T3 T4
Outdoor Temp.(°C)
The intelligent defrosting program calculates the time required for defrosting according to the actual system status, eliminating Heating operation
heat losses from unnecessary defrosting. A specialized defrosting valve reduces time required for defrosting to as little as four
Intelligent defrosting T2
T3 T4
Heating capacity
t min ∆t
Time
29 30
Easy Control ADDTIONAL CONTROL
EASY CONTROL ON/OFF, Cool/Heat and Alarm ports on chiller PCBs allow switches to be connected to enable additional remote control
Touch key wire controller as standard accessory to control the chillers. functionality.
Note: When the additional control functionality is added, the ON/OFF control and mode selection functionality of the wired controller is disabled.
Model KJRM-120H/BMWKO3-E
MODBUS FUNCTION
Modbus is an open protocol that is widely used, especially in BMS building control systems. It can connect Max. 16 wired
Appearance controllers and each controller can control Max. 16 units.
ELFOEnergy Nova II Series
Three different user levels ensure users can easily access control functions and allow engineers convenient access to operating
parameters.
31 32
High Reliability Easy Installation & Maintaince
Four stages of oil control technology ensure all outdoor compressor oil is always kept at a safe level, eliminating any compressor
oil shortage problems.
hydraulic module
water flow switch wired controller
(customization option)
KJRM-120H/BMWKO3-E
2nd stage
1st stage
Only water piping installation is needed, no need to install refrigerant piping. WCAN-XSi 14.1 uses screwed connection,
3rd stage while WCAN-XSi 22.2, WCAN-XSi 35.2 use hoop connection.
Fan motor
Standard products:
72h of neutral salt mist
33 34
Unit Dimensions (Unit: mm) Specifications
WCAN-XSi 30.1T
Model WCAN-XSi 30.1T WCAN-XSi 60.2T WCAN-XSi 90.2T
WCAN-XSi 60.2T Power s uppl y V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50
Ca pa ci ty kW 27 55 82
Ca pa ci ty kW 31 61 90
H
COP
B
WCAN-XSi 30.1T top view WCAN-XSi 60.2T top view Bottom view
Type Rotary Rotary Scroll
Compres s or
Qua nti ty 1 2 2
A
Ai r s i de hea t excha nger Type Finned tube Finned tube Finned tube
A
Type DC motor DC motor DC motor
F
Vol ume L 2.44 5.17 7.05
Wa ter s i de hea t excha nger
Wa ter fl ow m3/h 5 9.8 15
E
Wa ter pres s ure drop kPa 55 61 75
D Pump hea d m / / /
WCAN-XSi 60.2T left view WCAN-XSi 60.2T left view Front view
Type R410A R410A R410A
Refri gera nt s ys tem
Cha rged vol ume kg 10.5 17.0 27.0
WCAN-XSi 90.2T
ELFOEnergy Nova II Series
ra nge
A Hea ti ng °C -15 to 30 -15 to 30 -20 to 30
Note:
1. Cooling: Chilled water inlet/outlet temp.12/7°C; outdoor ambient temp. 35°C DB.
E
2. Heating: Warm water inlet/outlet temp. 40/45°C; outdoor ambient temp. 7°C DB/6°C WB.
D 3. Sound pressure level is measured at a position 1m in front of the unit and 1.1m above the floor in a semi-anechoic chamber.
Front view Bottom view 4. Capacity and efficiency data calculated in accordance with EN14511; EN14825
Model A B C D E F G H
WCAN-XSi 30.1T 1870 1000 1175 204 200 470 800 926
WCAN-XSi 60.2T 2220 1055 1325 234 210 470 1105 958
WCAN-XSi 90.2T 3220 1095 1513 286 210 470 2116 1008
35 36
FEATURES
4 way cassette
Duct
Product Lineup
Capacity (kW) 5 7 10 12 14 16
Wide operation temperature range
ELFOEnergy Mini Chiller Series
Power Supply
COOLING MODE
220-240V/1Ph/50Hz / / -5°C 46°C
380-415V/3Ph/50Hz / / /
HEATING MODE
-15°C 27°C
With Eurovent certification
37 38
A+ rated energy efficiency at part load ADVANCED TECHNOLOGY
35°C
The DC inverter chiller integrates the latest technological innovations and DC inverter technology, optimally designed fan shape and air discharge grille ensure low sound values.
ensures precise temperature regulation and highly efficient energy usage,
A +++
making a significant contribution to the limiting the impact on the Air deflector
A ++
environment. A+ A+
A Grille
B
C
D
Fan
Powerful Large Propeller Newly Designed Fan Guard
DC inverter compressor
Twin rotary DC inverter compressor is used. The output of the outdoor unit can be adjusted precisely according to the energy
demanded.
High efficiency DC motor: EXV is used for stable and accurate gas flow control. Refrigerant inlet
- Creative motor core design High efficiency plate heat exchanger Water outlet
- High density neodymium magnet
Plate heat exchanger uses metal plates to transfer heat between
- Concentrated type stator
- Wider operating frequency range refrigerant and water. The fluids are exposed to a much larger surface
area because the fluids spread out over the plates, so both heat
Better balance and Extremely Low Vibration: transfer efficiency and heat exchanger speed are greatly improved.
- Twin eccentric cams
Multi protections including voltage protection, current protection,
- 2 balance weights
anti-freezing protection and water flow protection ensure system
Water inlet
Highly Stable Moving Parts: safety running.
Refrigerant outlet
- Optimal material matching rollers and vanes
- Optimize compressor drive technology High efficiency water pump
Compressor - Highly robust bearings
(Twin Rotary) structure The water pump used is compliance with Erp directive, which is A degrade efficiency standard.
- Compact structure
DC fan motor EASY INSTALLATION
DC inverter stepless straight-forward operations like connection of the power supply, the water supply and the air distribution FCUs.
adjustment
The units are equipped with axial fans so they can be installed directly outdoors.
AC inverter
multistep adjustment
ELFOEnergy Mini Chiller Series
Hydraulic
Original design module
Hydrophilic fins + inner-threaded pipes
New design High efficiency inner-threaded pipe,
enhance heat transfer.
The new designed window fins enlarge the heat-exchanging area, decrease the air resistance, save more power and enhance
Water pump Water pressure
heat exchange performance. differential valve
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.
The specially coated blue fins enhance durability and protect against corrosion from air, water and other corrosive agents,
Expansion tank
assures a longer coil service life.
39 40
Specifications
EASY CONTROL
Note: When the wired controller is connected, the built-in controller is only for display, check and diagnosis functions.
41 42
Specifications
Unit Dimensions (Unit: mm)
WGAN-XMi 2.1M
WGAN-XMi 3.1M
Model WGAN-XMi 6.1T WGAN-XMi 7.1T WGAN-XMi 8.1T
Power supply V/Ph/Hz 380-415/ 3/50
Capacity kW 11.2 12.5 14.5
Rated input kW 3.38 3.90 4.70
Cooling1
Rated current A 5.5 6.4 7.7
EER 3.31 3.20 3.10 626
Capacity kW 12.2 14.2 15.6
963
Rated input kW 2.60 3.10 3.60
Cooling2
EER 4.69 4.58 4.33
SEER 6.58 7.03 7.10
435
396
382
342
Capacity kW 12.3 13.8 16.0
Rated input kW 3.72 4.25 4.85
Heating3
Rated current A 6.1 7.0 8.0
COP 3.31 3.25 3.30
Capacity kW 13.0 15.1 16.5 995
Rated input kW 2.85 3.35 3.92 1008
Heating4
COP 4.56 4.51 4.21
SCOP 3.66 3.78 3.39
Seasonal space heating energy efficiency (ηs) 143% 148% 133%
Seasonal space heating energy efficiency class A+ A+ A+
WGAN-XMi 5.1M
Max. input current A 8.9 9.6 10.1
WGAN-XMi 6.1M
Compressor Type Rotary
WGAN-XMi 6.1T
Motor type DC motor
Outdoor fan WGAN-XMi 7.1T
Air flow m3/h 4,800 4,800 6,200 WGAN-XMi 8.1T
Air heat exchanger Type Fin-coil
Type Plate
Water heat Water volume L 0.78 0.78 1.06
exchanger Water flow m3/h 1.92 2.15 2.49
Water pressure drop kPa 18 18 19
Pump head m 7.0 7.0 7.0
Water pump
Water volume L/min 4 4 4
Expansion tank volume L 3 3 3
Type R410A
Refrigerant
Charged volume kg 2.8 2.9 3.2
Throttle type Electronic expansion valve
Sound power level dB(A) 68 70 72
1327
Sound pressure level5 dB(A) 62 62 62
ELFOEnergy Mini Chiller Series
360
400
348
320
Water outlet Cooling °C 4-20
temperature range Heating °C 35-54
43 44