7.2.0
PVsyst - Simulation report
Grid-Connected System
Project: NguyenVanLinh_10kW
Variant: New simulation variant
No 3D scene defined, no shadings
System power: 10.37 kWp
DIEN_MAT_TROI_Trì Bình-Bình Nguyên - Vietnam
Author
Project: NguyenVanLinh_10kW
Variant: New simulation variant
PVsyst V7.2.0
VC0, Simulation date:
25/11/22 20:33
with v7.2.0
System summary
Tóm tắt về hệ thống
Grid-Connected System
Simulation for year no 1
System information
PV Array Inverters Nb. of units Pnom total
Nb. of modules Pnom total Pnom ratio
34 units 1 Unit
10.37 kWp 10.00 kWac 1.037
Results summary
Produced Energy 13.63 MWh/year Specific production 1314 kWh/kWp/year Perf. Ratio PR 75.34 %
Solar Fraction SF 0.70 %
Table of contents
PVsyst V7.2.0
VC0, Simulation date:
25/11/22 20:33
with v7.2.0
General parameters
No 3D scene defined, no shadings
Grid-Connected System
PV Field Orientation
Sheds configuration
Orientation
No 3D scene defined
Fixed plane Models used
TranspositionPerez
DiffusePerez, Meteonorm Circumsolarseparate
Tilt/Azimuth14 / 0 °
Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. Year
186 158 179 167 156 144 153 155 163 167 160 164 1951 MWh
PV Array Characteristics
PV module Inverter
Manufacturer Eurener Manufacturer Solaxpower
Model Eurener PEPV/72 305w Model X3-MIC-10.0kW with 2 MPPT
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 305 Wp Unit Nom. Power 10.00 kWac
Number of PV modules 34 units Number of inverters 1 Unit
Nominal (STC) 10.37 kWp Total power 10.0 kWac
Modules 2 Strings x 17 In series Operating voltage 160-900 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.04
Pmpp 9.07 kWp
U mpp 550 V
I mpp 16 A
Array losses
Thermal Loss factor
Array Soiling Losses Module temperature according to irradiance DC wiring losses
Loss Fraction3.0 % Global array res. 49 mΩ
Loss Fraction 0.1 % at STC
Uc (const) 20.0 W/m²K
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.2.0
VC0, Simulation date:
25/11/22 20:33
with v7.2.0
Main results
System Production
Produced Energy (P50) 13.63 MWh/year Specific production (P50) 1314 kWh/kWp/year Performance Ratio PR 75.34 %
Produced Energy (P90) 13.30 MWh/year Specific production (P90) 1283 kWh/kWp/year Solar Fraction SF 0.70 %
Produced Energy (P95) 13.21 MWh/year Specific production (P95) 1274 kWh/kWp/year
GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_User E_Solar E_Grid EFrGrid
kWh/m² kWh/m² °C kWh/m² kWh/m² MWh MWh MWh MWh MWh
January 105.1 62.87 20.50 115.5 108.7 0.970 186.0 0.950 0.000 185.1
February 143.7 62.01 21.95 157.8 149.6 1.287 157.9 1.263 0.000 156.7
March 147.8 76.63 24.49 153.3 145.0 1.235 178.6 1.211 0.000 177.3
April 182.6 80.63 26.91 181.0 171.3 1.425 167.0 1.399 0.000 165.6
May 190.3 81.02 29.33 180.5 170.0 1.400 156.2 1.373 0.000 154.9
June 197.0 77.02 30.18 183.0 172.1 1.414 144.0 1.388 0.000 142.6
July 185.9 82.21 29.91 174.5 163.9 1.355 153.3 1.330 0.000 151.9
August 172.7 80.96 29.21 168.1 158.4 1.311 154.8 1.286 0.000 153.5
September 142.8 80.82 27.04 144.8 136.7 1.156 162.7 1.134 0.000 161.6
October 116.4 72.93 25.71 122.9 115.9 0.996 166.7 0.975 0.000 165.7
November 72.3 52.83 23.81 77.2 72.4 0.639 159.8 0.622 0.000 159.2
December 78.1 48.24 21.44 86.1 80.9 0.714 163.7 0.696 0.000 163.0
Year 1734.8 858.19 25.89 1744.4 1644.9 13.901 1950.7 13.629 0.000 1937.0
Legends
GlobHor
Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor
Horizontal diffuse irradiation E_User Energy supplied to the user
T_Amb
Ambient Temperature E_Solar Energy from the sun
GlobInc
Global incident in coll. plane E_Grid Energy injected into grid
GlobEff
Effective Global, corr. for IAM and shadings EFrGrid Energy from the grid
PVsyst V7.2.0
VC0, Simulation date:
25/11/22 20:33
with v7.2.0
Loss diagram
-1
3.39% PV loss due to temperature
-3.00%
Module quality loss
-2.07%
-0.09% Mismatch loss, modules and strings
Ohmic wiring loss
13.90 MWh Array virtual energy at MPP
-1.94% Inverter Loss during operation (efficiency)
0.00%
Inverter Loss over nominal inv. power
0.00%
0.00% Inverter Loss due to max. input current
-0.02%
0.00% Inverter Loss over nominal inv. voltage
Inverter Loss due to power threshold
grid
Inverter Loss due to voltage threshold
consumption
13.63 MWh Available Energy at Inverter Output
to user
to user to grid
from grid
from solar
PVsyst V7.2.0
VC0, Simulation date:
25/11/22 20:33
with v7.2.0
Special graphs
Daily Input/Output diagram
PVsyst V7.2.0
VC0, Simulation date:
25/11/22 20:33
with v7.2.0
Aging Tool
Aging Parameters
Time span of simulation 25 years
Module average degradation Mismatch due to degradation
Loss factor 0.4 %/year Imp RMS dispersion 0.4 %/year
Vmp RMS dispersion 0.4 %/year
Meteo used in the simulation
#1 Trì Bình - Bình Nguyên MN80 SYN
Years 1990 (reference year)
Years simulated 1,6,11,16,21,25
Performance Ratio
PVsyst V7.2.0
VC0, Simulation date:
25/11/22 20:33
with v7.2.0
Aging Tool
Aging Parameters
Time span of simulation 25 years
Module average degradation Mismatch due to degradation
Loss factor 0.4 %/year Imp RMS dispersion 0.4 %/year
Vmp RMS dispersion 0.4 %/year
Meteo used in the simulation
#1 Trì Bình - Bình Nguyên MN80 SYN
Years 1990 (reference year)
Years simulated 1,6,11,16,21,25
PVsyst V7.2.0
VC0, Simulation date:
25/11/22 20:33
with v7.2.0
Probability distribution