Service.de@Lenze.com Service.de@Lenze.

com
L +49 (0) 5154 / 1112
00 8000 / 24 4 68 77 (24h helpline)
L +49 (0) 5154 / 1112
00 8000 / 24 4 68 77 (24h helpline)

Acceptanceis successful -> S_Error, S_Ack = OFF 5.


LED S_Ack stops flashing -> Release T1 andT2 (within 2.5 s) 4.
LED S_Ack lights up -> Press T1 and T2 -> S_Ack starts to flash 3.
LED S_Ack stops flashing -> Release T1 and T2 (within 2.5 s) 2.
LED S_Ack lights up -> Press T1 and T2 -> S_Ack starts to flash 1.

Use pushbuttons T1 and T2 to perform the routine described.


Acceptance of parameters:

Requirement ->

Acceptance of safety parameters

8400 protec 8400 protec


Guideline Guideline

Guideline Guideline
Overview of possible error messages
8400 protec Service switch 8400 protec
US01: Live bit of PLC missing
US02: Thermal contact of brake resistor has been tripped
CANopen PC-Connection
dH10: Fan failure: change device Address & Baudrate
OH1 : Heatsink overtremperature: reduce utilization Memorymodule
OH3 : Motor thermal contact tripped: overheat / open curcuit
OH4 : Heatsink temp. warning: reduce utilization 7-segment
Display
OU: DC bus overvoltage: use longer acc time or brake resistor
OC1: Power section – short circuit: check wiring
OC2: Power section – earth fault: check wiring Switch T1 & T2

OC5: Device overload: check dimensioning LEDs


OC6: Motor overload: check dimensioning
OC10: Maximum current reached: check mechanic
OC11: Maximum current reached: check mechanic
OC12: brake resistor overload: check mechanic
Device replacement
OC13: Maximum current reached: check mechanic 1. Set the Serviceswitch to OFF
LU: DC bus undervoltage: mains missing 2. Release all the plug connections
3. Release the PE connection at the earthing stud
LP1: Motor phase failure: check wiring 4. Remove the device
5. Take out the memorymodule and insert it into the replacement device
SU03: Too frequent mains switching
6. Install the replacement device
SU05: overload IO-supply voltage 24V 7. Screw in the PE connection and plug in all the connectors
8. Set the service switch to ON
IO11: Overcurrent at DO1/DO2 9. Carry out the procedure for accepting the safety data
CI: PROFInet failure: see logbook for more details
Device is ready for operation.

L L
00 8000 / 24 4 68 77 (24h helpline) 00 8000 / 24 4 68 77 (24h helpline)
+49 (0) 5154 / 1112 +49 (0) 5154 / 1112
Service.de@Lenze.com Service.de@Lenze.com