Intra Oral Camera

Ueser Manual

Intra Oral Camera


Ueser Manual

Ver:191130
1 . General Information Parameter
002 General Introduction
lmage Sensor: CMOS1/4
003 Specification

Operating System: Embedded Operating System


2 .AssemblyInstruction
Picture Display:1 Picture / 4 Pictures / 16 Pictures
006 Multimedia Integrated Monitor
006 Intraoral Camera System Operation: Remote Control / Key Control
/ Mouse Marking Function
007 Intraoral Camera Holder
Backup Mode: Backup to USB device automatically

3 . User Guide(08-011) Storage Capacity: Max 32G

Picture Storage Format: JPG


4.Other Information
Focus Range: 5MM--50MM
012 Troubleshooting
013 Maintenance Consumption: 30W
014 Warranty Policy
WIFI Transmission:Yes
Standard Package Multimedia Integrated Monitor
NO Part Name QTY
1 Multimedia Integrated Monitor 1 Pcs
2 Intraoral Camera 1 Pcs
3 Remote Control 1 Pcs
4 Wireless Mouse 1 Pcs
5 DC Adapter (12V) 1 Pcs Intraoral Camera
6 DC Cable 1 Pcs
7 Intraoral Camera Cable 1 Pcs
8 Intraoral Camera Holder Bracket 1 Pcs
9 Intraoral Camera Holder 1 Pcs
Intraoral Camera
10 WIFI Receiver 1 Pcs Cable
11 USB Device(8G) 1 Pcs
12 Screw for Holder and Bracket 1 Package
WIFI Receiver

Option Remote Control Wireless Mouse


NO Part Name QYT
1 Stand 1Set
Multimedia Integrated Monitor

Multimedia Integrated Monitor Intraoral Camera

①Intraoral Camera Cable Input Interface

②DC Input 12V

③ VGA

④ HDMI

⑤ AV

⑥ Audio Input

⑦ Audio Output

⑧ USB Input(For playing vedio, music,and picture)

⑨ Antenna or CCTV Input Interface

⑩ USB Output (For USB device,WIFI receiver,Mouse,etc)


Remark:VGA is used by Multimedia Integrated Monitor,please use
HDMI for PC connection for a good display performance.
Intraoral Camera Holder Remote Control

Bracket
Power On Key Function

Turn on the main power,then press the POWER button,the power


indicator will become blue.

Key 1: ①Capture ②Take Picture ③Turn off Intraoral Cameras (Long press)
④Save Picture
Key 2: ①Switch Picture Mode(Single Picture⇔Multi-Picture0)
②Cancel Picture(Under Mode of Capture)
③Switch to Mode of 16 Pictures, Press One More for Storage.

Input Signal Selection Key 3: ①Switch to Browse Mode ②Play Forward


Key 4: ①Play Backward
Key 5: ①Delete Current Picture(Under Mode of Browse)
②Create QR Code (Under Mode of Browse, Press Key 1 Together)

(UV Version)
Key 1: ①Capture ②Take Picture ③Turn off Intraoral Cameras (Long press)
④Save Picture
Key 2: ①Switch Picture Mode(Single Picture⇔Multi-Picture0)
②Cancel Picture(Under Mode of Capture)
③Switch to Mode of 16 Pictures, Press One More for Storage.
Key 3: ①White Light Source ②Mode of Checking Dental Calculus
③Mode of Checking Dental Plaque ④Mode of Checking Invisible Dental Plaque
Key 4: ①Swift to Browse Mode
Key 5: ①Delete Current Picture(Under Mode of Browse)
②Create QR Code (Under Mode of Browse, Press Key 1 Together)
How to use WIFI receiver: Troubleshooting

1.Cell phone If you have any question about the Intraoral Camera System,first
refer to this list. If none of these troubleshooting tips apply, please
(1) After taking pictures with Intra Oral Camera, enter the browse mode.
contact the maker for technical support.
Short press the key 1 and key 5 of Intra Oral Camera together to create
the QR code.
(2) Use cell phone to connect the WIFI signal same name show as the monitor Issue Support and Explanation
(WIFI Password: same as the number of WIFI name).
(3) When finish connection, use any scanner application to scan the QR code to
get the checkup pictures. Monitor cannot turn on Please check the adapter work or not.

2.Computer (with WIFI module)


Please check whether there is smear on the
(1) Install the application of Dental Video Capture System Picture Quality screen or camera lens. If none, please
contact the agent.
Check the USB device for the file of “Wireless WIFI model using method” ,
double click to start the installment.
Please check whether USB device can be
This application supports Windows XP, Windows 7, Windows 8., etc. No date in the USB device recognized on computer.
(2) Connect WIFI signal
Click to connect the WIFI signal same name show as the monitor Black screen or no signal Inverter board or circuit board is damaged.
(WIFI Password: same as the number of WIFI name).
(3) How to use Dental Video Capture System
Picture cannot show fully Press AUTO key on remote control
Open Dental Video Capture System, create customer information. or not in a right position to adjust screen automatically.
Click “Capture Menu” to start the real time checkup together with computer
and monitor.
No image while using
ntraoral Camera Please check whether it connected well.
Maintenance

1.Please read the Manual before using this product.


2.Please do not open the Intraoral Camera System without permit.
3.To protect the circuit board or product, please keep the signal
connector away from the sharp goods, metal or liquid.
4.Please keep the power supply cable or Intraoral Camera
Cable away from stress.
5.Please take off the plug or turn off the power, if the Intraoral
Camera System won't be used for a long time.
6.Please use the DC Adapter specified by the maker to avoid
the damage from product. If the power supply cable or plug
is broken, please stop using and contact the agent in time.
7.Keep in a dry, cool and well-ventilated place. Avoid
exposure to excessive heat, light and air for prolonged of time.
Keep away from strong acids, inflammables and explosives.
Clean the surface of Intraoral Camera System regularly.