t CHAPTER 6.

ELEVATORS, DUMBWAITERS, ESCALATORS AND MOVING WALKS


3.2 FIoor Over Hoistways: 3.3 Hoistway Protection in Case of Fire.
Hoistway of elevators shall be provided in cases
a. Where Required. A metal or concrete floor of fire as required by the local codes such as the
shall be provided at the top of the hoistway. National Building Code, National Fire and the
Philippine Electrical Code.
Exceptions: Floors are not required below:
3.4 Hoist for all elevators shall be
1. Secondary and deflecting sheaves enclosed throughout their height, and there
of tractiontype machines located be no openings except for necessary
over the hoistway. windows or skylights.

Overhead sheaves, governors, and 3.5 Hoistway for elevators outside building shall be
other equipment where the elevator substantially enclosed to a height of at least
machine is located below or at the 3 000 mm provided that the enclosure shall be
side of the hoistway. continuous to the top of any side on which there
is access to the cage.
b. Location of Floor. The floor shall be
located: The enclosure shall either be a continuous wall
or substantial grill work, metal bars, or wood
1. Above or level with the tope of the slats.
machine beams where the machine
is located over the hoistway; 3.7 Openings fixed enclosureis shall not exceed 50
mm in their lesser dimensions, at all places
Below the overhead sheaves where where moving cars, counter-weights, or sliding
the machine is not located over the doors present hazard they shall not exceed 10
hoistway. mm in their lesser dimensions.

Strength of Floor. The floor shall be Hoisfway enclosures and hoistway doors and
capable of sustaining a concentrated load of door assemblies shall be of fire-resistive
136 kg on any 2 580 mm area and in construction of not less than 1:hour fire
addition where it constitutes the floor of the resistance.
main or secondary level machinery space, it
shall be designed for a live load of not less 3.9 Where four or more elevators serve or the same
than 6'tl kg/m in all open areas. A sign portion of a building, they shall be located in not
stating the maximum allowable load of less than two (2) hoistway and in no case shall
which the floor is designed shall be more than four (4) elevators be located in any
permanently displayed in all main and one hoistway.
secondary machine-room spaces. The sign
shall be of metal with black letters and 3.10 Window and Skylights:
figures at least 100 mm high on a white
background. a. Window and Skylight Frames and Sash.
Windows in the walls of hoistway enclosures
d. Gonstruction of Floors. Floors may be of are prohibited. Frames and sashes of
concrete, or may be of metal construction windows in machine rooms and skylights
with or without perforations. Metal floors shall be of metal.
shall conform to the following:
1. Skylights Guards. A guard
1. lf of bar{ype grating, theopenings securely anchored to the supporting
between bars shall reject a ball 20 structure, consisting of a wire mesh
mm in diameter. screen of at least 2.325 mm
diameter steel wire with openings
2. lf of perforated sheet metal or of which will reject a ball 25 mm in
fabricated open work construction, diameter, or an expanded metal
the openings shall reject a ball 25 screen of equivalent strength and
mm in diameter. open area, shall be installed above
every elevator skylight. A similar
screen of at least 1.205 mm

70