GENERAL A new Carriage Control Card (CCC) has been released. The new CCC, P/N
INFORMATION: 1275051/003, replaces the previous CCC, P/N 1107833/101, due to part
obsolescence. The new CCC requires software to be loaded with FlashWare. The
CCC also incorporates the Auxiliary card (if equipped).
SERVICE 1. Verify that the FlashWare version on your computer is 7.8 or newer.
INFORMATION: 2. Verify that you have the most current software installed on your computer as
listed on the SAP Portal.
3. Using cable 610-809/W7P, connect the computer to the 9-pin RS-232 port on
the Vehicle Manager (VM). Consult FlashWare Help for proper configuration, if
required.
4. Turn the key switch ON.
5. Establish communication with the vehicle using FlashWare.
6. Save the lift truck FlashWare configuration settings.
7. Check the software in the motor controllers. The motor controller software
should be version 12.115 or newer. Update the software versions if they are
older.
8. Cycle the key switch OFF and ON. The lift truck will go through self-test and be
operational. Re-key the lift truck if it does not complete self-test and sound the
horn. This step could take multiple re-keys.
9. Verify continuity between the fuse relay card ground screw and the lift truck
frame using a digital multi meter. Resistance should be less than 0.5 ohm.
10. Install the new CCC following standard Electrostatic Discharge (ESD) precau-
tions.
Note: If the current CCC has a jumper located in PC3, transfer it from the old
CCC to the new card.
Note: If your lift truck is equipped with an auxiliary card, as shown in Figure 1
below, remove it and connect the cables to the new connection points
shown in Figure 2. Use the CCC schematic, Figure 3, for reference.
®
Raymond is a registered trademark of The Raymond Corporation RSI OPR-18-005A
2018 The Raymond Corporation. D20055193
1306777/001 Page 1 of 6
PC3
Auxiliary Card. Not on
all models.
PC3
PC20
PC19
11. Make sure the upper right mounting screw is installed and tightened. This screw
provides a ground path through a capacitor to reduce noise.
12. Connect to FlashWare and then click Other Device Software.
13. Select the CCC and then load with the newest software version. Verify the
newest software version using the Model Number Table in the SAP Portal as
reference.
®
Raymond is a registered trademark of The Raymond Corporation RSI OPR-18-005A
2018 The Raymond Corporation. D20055193
1306777/001 Page 3 of 6
Below are new troubleshooting procedures for trucks equipped with an Auxiliary
mast, with a new CCC installed.
This test monitors the state of the auxiliary lift switch (S32). This switch causes the
auxiliary mast to lift. This test displays what the CCC is reading from the switch.
S31 (Aux lift left-hand deadman) must also be pressed during this test. The S31
switch circuit must be functional.
Run Test:
Out Off
Pressed On
If results do not match the preceding table, the test has failed. Perform diagnosis
and repair.
®
Raymond is a registered trademark of The Raymond Corporation RSI OPR-18-005A
2018 The Raymond Corporation. D20055193
1306777/001 Page 4 of 6
Test I42 - Aux Mast Lower Switch S33 (Option)
This test monitors the state of the auxiliary lower switch (S33). This switch causes the
auxiliary mast to lower. This test displays what the CCC is reading from the switch.
Note: Switch S31 (Aux lift left-hand deadman) must also be pressed during this
test. The S31 switch circuit must be functional.
Run Test:
Out Off
Pressed On
If results do not match the preceding table, the test has failed. Perform diagnosis
and repair.
Action/
(+) (-) Expected Step Step
Step Meter
Lead Lead Results Passed Failed
Setting
®
Raymond is a registered trademark of The Raymond Corporation RSI OPR-18-005A
2018 The Raymond Corporation. D20055193
1306777/001 Page 5 of 6
Test I44 - Aux Limit Switch S34
This test monitors the state of the auxiliary limit switch (S34). This switch causes the
auxiliary mast to decelerate before reaching the stops. This test displays what the
CCC is reading from the switch.
Run Test:
If results do not match the preceding table, the test has failed. Perform diagnosis
and repair.
Action/
(+) (-) Expected Step Step
Step Meter
Lead Lead Results Passed Failed
Setting
FILING File this notice in Maintenance Manual 1031794D next to pages 6-88, 6-89, 6-92
INSTRUCTIONS: and 7-82.
®