Technical Manual. Radar System. EMx40
Technical Manual. Radar System. EMx40
EMx40
Technical Manual
SAS au Capital de 2 158 244 € - 444 871 933 R.C.S. Bourges - APE : 2651B
Headquarter : 9, rue Isaac Newton - 18000 Bourges - France
Radar System
Technical Manual
EMx40
1st Edition
Released February 2013
INTRODUCTION
This manual is issued specifically for the data processing racks of the TA3840 or EMx40 system.
It contains instructions detailed for functioning, operation and cleaning of this system.
Keep this manual to hand so that you can refer to it at any time. Ensure that it is
complete and kept close to the equipment.
The racks TA3840C and TA3840S, as well as the TA3840R repeater module are integrated in the
system for processing the tankers liquid cargo. Maintenance must be carried out by a qualified
operator in communicating electronic systems.
We also draw your attention to the fact that the connection of equipments or the use of products
other than those recommended by Honeywell Marine may present risks for which we will not be
liable.
This manual must not be reproduced in any form whatsoever without the prior written approval of
Honeywell Marine who cannot be held responsible for any use of the information contained in this
manual.
As we want you to take advantage of the most of the latest technology and new equipment, as well
as to benefit from our experience, our equipments may undergo technical or design changes. As a
result, some of the features and information in this manual may change without prior notice and
without any obligation to up-date it.
Should you encounter any problems or have any questions about your TA3840 or EMx40 system,
please do not hesitate to contact your nearest Honeywell Marine customer service.
Other documents
The installation of EMx40 system transmitters is described in the MI5016E installation
manual.
The maintenance of EMx40 system transmitters is described in the MM5016E maintenance
manual.
The description and operation of the racks TA3840C/R and TA3840S for measuring data
collection are described in the MT5008E technical manual.
SAFETY PRECAUTIONS:
Current regulations and legislation applicable to hazardous areas must imperatively
be known and followed by personnel responsible for commissioning and operating
an intrinsically safe equipment.
Take care to switch the power off before proceeding to any disconnection or
removal of the transmitters.
WARNING:
Our equipments are designed and manufactured in accordance with local Our
equipments are designed and manufactured in accordance with local safety
regulations, and in particular European directives relative to reconciling
member states' legislation:
● 89/336/EEC and 2004/108/EC "Electromagnetic compatibility",
● ATEX 94/9/EC "Equipment and protective systems intended for use in
potentially explosive atmospheres",
● 96/98/EC "Marine equipment".
The EM540, EM940 radar and associated transmitters are certified for use in
hazardous area according to the intrinsic safety protection type. Examination
certificates are supplied in appendix.
They are intended for professional use and must be installed, used and
maintained by competent staff who are qualified in this type of equipment.
In particular we wish to draw your attention to the fact that we cannot be held
responsible if:
● Any technical alterations are made to our appliances without our written
authorization,
● Our equipments are damaged by being operated in conditions other than
the intended usage of their technical classification (power supply,
temperature, environment, etc.).
The safety instructions given in this manual are merely given for guidance
purposes to protect you and all those using and working on our equipments.
Honeywell Marine cannot foresee all dangerous situations that might arise.
This is why the owner and/or the operator is responsible for the operating
safety of the system.
Regulation marking
IDENTIFICATION NAMEPLATE
II 1(1) GD
Ex ia [ia Ga] IIB or IIC T4 Ga
LCIE 05 ATEX 6087X
IECEx LCIE 12.0009X
EM540 MARKING
S/N
P/N
TAG
IDENTIFICATION NAMEPLATE
II 1(1) GD
Ex ia [ia Ga] IIB or IIC T4 Ga
LCIE 05 ATEX 6087X
IECEx LCIE 12.0009X
EM940 MARKING
S/N
P/N
TAG
IDENTIFICATION NAMEPLATE
II 1 GD
Ex ia IIC T6 Ga
Ex ia IIIC T80°C Da IP66/67
LCIE 03 ATEX 6246X
IECEx LCI 11.0039X
MARKING
S/N
T90101-P
P/N
TAG
IDENTIFICATION NAMEPLATE
II 1 GD
Ex ia IIC T6 Ga
Ex ia IIIC T80°C Da IP66/67
LCIE 03 ATEX 6246X
IECEx LCI 11.0039X
MARKING
S/N
P/N
TAG
EC TYPE EXAMINATION CERTIFICATE, SEE APPENDIX C
IDENTIFICATION NAMEPLATE
II 1 GD
Ex ia IIC T6 Ga
Ex ia IIIC T80°C Da IP66/67
LCIE 07 ATEX 6022X
IECEx LCI 11.0038X
MARKING
S/N
P/N
T901-P 01TA TAG
MARKING
S/N
LOG3840 P/N
TAG
TABLE OF CONTENTS
TA3840C
24 Vdc + RS232 /
RS485 / RS422
Special
RS232 / RS485
applications
TA3840S
or
Up to 63 other EMx40 radars
or
EM940 EM540
LOG3840
(optional)
T901-P
The EMx40 radar level transmitters measure the liquid level inside the tank and
transmit the information to the TA3840C communication unit by means of the
TA3840S safety unit located in cargo control room. Each EMx40 radar is fitted with
entries for temperature/pressure transmitter and the EM940 radar with additional
analog transmitters.
The LOG3840 deck digital indicator displays locally the level, temperatures,
pressure measured by transmitters. It is powered by the TA3840S safety unit and
communicates on the same bus than the radar.
General synopsis
The general synopsis of the system is shown on the previous page.
● Measures the liquid level (in mm) by processing the microwave signal thanks to its
dedicated signal processor,
● Concentrates the measurements of:
- Liquid temperature coming from three sensors at different levels (top, middle
and bottom of the tank),
- IG pressure coming from a pressure sensor,
- Up to two other analog measurements for EM940 radar
2
5 6
1 Terminal box cover
2 Three connections for cable input
3 FLAT-T technology antenna
4 316L stainless steel housing
5 Holes for M20 screws to fasten on the socket
6 Pivot hinge
EM940 radar
8 1 2 7 3
5 4 6
● The liquid temperature in the cargo tank at up to three different levels (high, middle
and low),
● The inert gas pressure inside the cargo tank.
1 Temperature sensors
2 316L stainless steel housing
3 Removable cover
4 Cable connection
5 Nuts and washers to fasten on the socket
5 5
1 2 3
4
5
1 Temperature sensors
2 316L stainless steel housing
3 Removable cover
4 Cable connection
5 Screw location to fasten on the pump body
3
1
1 316L stainless steel housing
2 Terminal box cover
3 Cable connection
4 Flange
4
The LOG3840 deck indicator calculates and displays on the LCD screen:
2 3 4
1
1 Cable connection
2 LCD screen
3 Casing
1
4 Magnet switch
2. TECHNICAL SPECIFICATIONS
Operating : +/-5 mm
Temperature inputs 3 for Pt 100 at 0 °C RTD (IEC751)
Range: -165 °C to +250 °C
Signal transmission accuracy: ± 0.22 °C
Other transmitter input, for inert 3 analog input 0.5 to 2.5 Vdc
gas pressure Signal transmission accuracy: ± 0.3 % FS
Ambient operating temperature -35 °C to +70 °C
Operating pressure -200 to +1000 mbar
Protection index IP 66 / IP 67
Materials 316L stainless steel and PTFE
Dimensions 340 x h. 101 mm for 8" antenna
Process connection Flange ISO PN16 DN200 for 8" antenna
Typical electrical connections Two marine cables BV2 and one marine cable BV3 for
connection to the TA3840S safety unit (2 pairs + common
shield) and to the T901-P temperature/pressure transmitter (up
to 5 pairs + common shield), or three marine cables BV4 for
same connections
Packing-glands BV2 marine packing-glands for cable diameter min. 7 mm, max.
14.5 mm.
BV3 marine packing-gland for cable diameter min. 8.5 mm,
max. 19 mm.
BV4 packing-glands for cable diameter min. 16.5 mm, max.
22.6 mm.
Weight 13 kg
As the EM540 radar (and associated T901-P transmitter) can be installed in zone 0, a system certificate is available
under number LCIE 04 ATEX 6189 X, specifying in particular the cables required characteristics:
Electrical characteristics of the cable between the power supply rack and the radar
Radar Safety unit L (µH) L/R (µh/) C (µF)
EM540 class IIB TA840-I ≤ 100 ≤ 24 ≤ 7.9
TA3840S ≤ 270 ≤ 44 ≤ 3.08
EM540 class IIC TA840-I ≤ 22 ≤ 14.2 ≤ 3.8
TA3840S ≤ 22 ≤ 14.2 ≤ 3.8
The TA840-I safety unit is from a previous generation TA840 system. It is mentioned here in case of EM540
radars installed are spare on such a system.
Doc No: MT5016E – Revision 6 – ENG Transmitters
EMx40 Technical Manual 15
EM940 radar level transmitter
Measuring range 0.6 m to 40 m
Resolution 0.1 mm
Accuracy Instrument: +/- 3 mm
Operating : +/-5 mm
Temperature inputs 3 for Pt 100 at 0 °C RTD (IEC751)
Range: -165 °C to +250 °C
Signal transmission accuracy: ± 0.22 °C
IG pressure transmitter Ceramic capacitive sensor type
Standard range: 900 mbar to 1300 mbar or 800 to 2000
absolute mbar;
-70 to +350 gauge mbar
Output: 0.5 to 2.5 Vdc
Accuracy: 0.3 % FS
Other transmitters inputs 2 analog inputs 0.5 to 2.5 Vdc
Signal transmission accuracy: ± 0.3 % FS
Ambient operating temperature -35 °C to +70 °C
Operating pressure -200 to +1000 mbar
Protection index IP 66 / IP 67
Materials 316L stainless steel and PTFE
Dimensions 395 x h. 150 mm for 8" antenna
Process connection Flange ISO PN10 DN250
Typical electrical connections Two marine cables BV2 and one marine cable BV3 for
connection to the TA3840S safety unit (2 pairs + common
shield) and to the T901-P temperature/pressure transmitter (up
to 5 pairs + common shield), or three marine cables BV4 for
same connections
Packing-glands BV2 packing-glands for cable diameter min. 7 mm, max. 14.5
mm.
BV3 packing-glands for cable diameter min. 8.5 mm, max. 19
mm.
BV4 packing-glands for cable diameter min. 16.5 mm, max.
22.6 mm.
Weight 16 kg
SAFETY PROTECTION:
Precautions for intrinsically safe installation Ex ia:
The EM940 radar level transmitter is certified II 1 (1) G Ex ia [ia Ga] IIB or IIC T4
Ga under certificate N° LCIE 05 ATEX 6087X.
The EM940 radar must only be connected to TA3840S safety unit and T901-P
temperature/pressure transmitter.
The electrical safety parameters are as follow (refer to certificate in Appendix A).
Class IIC
Terminals Ui Ii (mA) Pi Ci (µF) Li Uo Io Po Co Lo
(V) (W) (mH) (V) (mA) (mW) (µF) (mH)
Power supply
≤ 12 ≤ 425 ≤ 3.25 ≤ 1.1 ≈0 / / / / /
(J2: 1-2)
RS485 circuit ≤
≤ 12 ≤ 100 ≤ 0.59 ≈0 ≤ 6.2 ≤ 139 ≤ 215 ≤ 34 ≤ 1.7
(J2: 3-4) 0.001
Temperature sensor
circuit
/ / / / / ≤ 6.2 ≤ 44 ≤ 68 ≤ 34 ≤ 18
(J6 and J7: 14-15-16,
14-17-18, 14-19-20)
Pressure sensor circuit
(J3, J4 and J5: 5-6-7, 8- / / / / / ≤ 6.2 ≤ 42 ≤ 65 ≤ 34 ≤ 20
9-10, 11-12-13)
As the EM940 radar (and associated T901-P transmitter) can be installed in zone 0, a
system certificate is available under number LCIE 04 ATEX 6189 X, specifying in
particular the cables required characteristics:
Electrical characteristics of the cable between the power supply rack and the radar
Radar Safety unit L (µH) L/R (µh/) C (µF)
EM940 class IIB TA840-I ≤ 100 ≤ 24 ≤ 7.9
TA3840S ≤ 270 ≤ 44 ≤ 3.08
EM940 class IIC TA840-I ≤ 22 ≤ 14.2 ≤ 3.8
TA3840S ≤ 22 ≤ 14.2 ≤ 3.8
The TA840-I safety unit is from a previous generation TA840 system. It is mentioned here in
case of EM940 radars installed are spare on such a system.
SAFETY PROTECTION:
Precautions for intrinsically safe installation Ex ia:
The T901-P temperature/pressure transmitter is certified II 1 G D Ex ia IIC T6 Ga
and under certificate n° LCIE 03 ATEX 6246X.
The T901-P temperature/pressure transmitter must only be connected to EMx40
radar.
The electrical safety parameters are as follow (refer to certificate in Appendix B).
Electrical characteristics of the cable between the radar and the T901-P temperature/pressure transmitter
Class IIC
Terminals Ui Iip (A) Iicc Ci (µF) Li Uo Io (A) Iocc Co Lo
(Vdc) (A) (mH) (Vdc) (A) (µF) (mH)
Power supply ≈
≤ 14.4 ≤ 0.53 ≤ 2.2 ≈ 3.7 ≤ 7,2 ≤ 0.21 - ≤ 9.8 ≤ 0.010
J3 : 1/3/2/4 0.007
Power supply ≤ ≤
≤ 14.4 ≤ 0.53 ≤ 2.2 ≤ 14.4 ≤ 0.53 ≤ 2.2 ≤ 9.8 ≤ 0.010
J3 : 5/7/6 /8 0.276 0.007
Backlight
≤ 14.4 ≤ 0.53 ≤ 2.2 ≈0 ≈0 - - - - -
J4 : 1 - 2
As the LOG3840 deck digital indicator can be installed in zone 0, specifying in particular
the cables required characteristics.
Starting up
This module is powered as soon as the TA3840S safety unit is on. The screen lights on
and data are displayed, depending on the operating parameters set up.
communication working
5 digits + decimal dot for level
Line 1 Spot 1 (RM) or communication
display
error (CE)
4 digits + decimal dot for
Line 2 Spot 2 level data error (LE)
temperature display
4 digits + decimal dot adjustable
for pressure display temperature data error
Line 3 Spot 3
Note: if a decimal dot is set up, (TE)
the mbar unit disappears.
Spot 4 pressure data error (PE)
The deck digital indicator includes a component (A) activated by an external magnet
through the window, for selection of the data displayed on the second line.
Operation
The display mode for level (ullage or innage), the unit used for level and temperature, and
the pressure decimal dot are set up by means of the utility software.
Only the different temperatures display, step by step, is possible.
● Touch the switch (A) with the magnet to display successively the average temperature
and the temperature measured by each sensor, according to the data availability
depending to the current T901-P transmitter type.
www.honeywellprocess.com