Aqt NX Manual
Aqt NX Manual
ELECTRONIC SERIES
CON T RO L VA LVES
PROGRAMMING MANUAL
TABLE OF CONTENTS
CO N T R O L VA LV E S
CAUTION
Installation Instructions
1. Place the softener tank where you want to install the unit making sure the unit is level and on a firm base.
(Maximum 4 feet apart for twin units.)
2. All plumbing should be done in accordance with local plumbing codes. The pipe size for the drain line should be the same size as the
drain line flow control female connection. Water meters are to be installed on soft water outlets. Twin units with (1) one meter shall be
installed on common soft water outlets of units.
3. Solder joints near the drain must be done prior to connecting the Drain Line Flow Control fitting. Leave at least 6" between the DLFC
and solder joints when soldering when the pipes are connected on the DLFC. Failure to do this could cause interior damage to the
DLFC.
4. Teflon tape is the only sealant to be used on the drain fitting. The drain from twin units may be run through a common line.
5. Make sure that the floor is clean beneath the salt storage tank and that it is level
6. Place approximately 1" of water above the grid plate (if used) in your salt tank. Salt may be place in the unit at this time.
7. On units with by-pass, place in by-pass position. Turn on main water supply. Open a cold soft water tap nearby and let run a few
minutes or until the system is free from foreign material (usually solder) that may have resulted from the installation.
8. Place the by-pass in service position.
9. Manually index the softener control into "service" position and let water flow into the mineral tank. When water flow stops, open a
cold water tap nearby and let run until air pressure is relieved.
10. Electrical: All electrical connections must be connected according to codes. Use electrical conduit if applicable. See Wiring Diagram
section for more information.
11. Plug into power supply
Page 3
AQT-NX
Keypad CO N T R O L VA LV E S
9
1 1. Flow Indicator
10
2. Time Of Day
2
11:30 PM * 4#1 11 3. Volume Remaining
4. Up Button
3 12000 GAL SRV 12
5. Shift Button
4 6. Status LED
7. Diagnostic Button
5 13
8. Page Up Button
6 9. Timer Indicator
Page 4
NX Programming
CO N T R O L VA LV E S User Parameter Settings
Language
Option:
English
SELECT LANGUAGE: Spanish
ENGLISH
System Number
Option:
System 4 (Single Valve) (Default)
SYSTEM TYPE: System 5 (Interlock, 2-4 valves)
System 6 (Series, 2-4 valves)
SINGLE UNIT 4 System 7 (Alternating, 2 valves)
System 9 (Alternating, 2-4 valves)
Valve Address
Option:
Valve address #1 (First Valve)
VALVE ADDRESS: Valve address # 2(Second valve) (Default)
Valve address # 3(Third Valve)
1 Valve address # 4(Fourth Valve)
Valve Quantity
Option:
2 valves--(default)
SYSTEM SIZE: 3 valves
4 valves(the fourth valve)
2
Regeneration Mode
Option:
Timer (System 4# ONLY) (Default)
REGEN TYPE: Meter IMM
Meter Delay
TIME CLOCK
Page 5
NX Programming
User Parameter Settings Cont. CO N T R O L VA LV E S
Valve Model
Option:
AQT-275, AQT-285, AQT-290, AQT-315,
VALVE TYPE: AQT-390 (Default)
AQT-275
Option:
Down Flow (Default)
REGENERANT FLOW: UF Brine Draw
DOWN FLOW
Option:
OFF (Default)
REMOTE SIGNAL: Range:
00:01 to 01:39 (HH: MM)
OFF
Flow Unit
Option:
Liters - Metric System (Default)
DISPLAY FORMAT: Gallons - American System
LITERS
Unit Capacity
Option:
G CaCo3 (Default)
UNIT CAPACITY: Grains
Range:
198000 g CaCO3 1 to 198000gCaCo3
1 to 9900000grains
Page 6
NX Programming
CO N T R O L VA LV E S User Parameter Settings Cont.
Capacity Safety
Range:
00% (Default) to 50%
CAPACITY SAFETY
FACTOR: 00%
Water Hardness
Option:
Milligrams per liter (Default)
FEED WATER Grains per gallon
Range:
HARDNESS:0030mgL 20 to 1999milligrams per liter
1 to 199grains per gallon
Option:
7 days (Default)
REGENERATION DAY Range:
1 to 99 days
OVERRIDE:07 DAYS
Option:
Off (Default)
REGENERATION DAY Range:
1 to 99 days
OVERRIDE: OFF
Regeneration Time
Option:
02:00 (HH:MM) (Default)
REGENERATION Range:
01 to 12 hours
TIME: 02:00 AM
Page 7
NX Programming
User Parameter Settings Cont. CO N T R O L VA LV E S
Option:
00:10 (Default)
BACK WASH: Range:
01 to 04 hours - 00:00 to 04:00
00:10 Note: the steps may changes
according to the regeneration flow
direction set before.
Option:
01:00 (Default)
BRINE DRAW: Range:
00:00 to 04:00 (HH:MM)
01:00
Option :
01:00 (Default)
RAPID RINSE: Range:
00:00 to 04:00 (HH: MM)
00:10
Option :
00:12 (Default)
BRINE FILL: Range:
00:00 to 04:00 (HH: MM)
00:12
Option :
Off (Default)
PAUSE&DELAY: Range:
00:00 to 04:00 (HH:MM)
OFF
Page 8
NX Programming
CO N T R O L VA LV E S User Parameter Settings Cont.
Auxiliary Relay
Range :
Disabled (Default)
AUXILIARY RELAY: Enabled
DISABLED
Range:
00:00--any time during regeneration
AUX RELAY OUTPUT process (with exception for the last minute)
Note: displayed when the aux relay is activated.
START: 00:00 For system 6# or 7#, Aux relay display when
chemical function is closed.
Range:
The start time - any time during
AUX RELAY OUTPUT regeneration process
END: 00:01
Option :
Disabled (Default)
CHEMICAL PUMP: Enable
Note: Do not display on 6# system or 7# system
DISABLED lag,Chemical function only works when
auxiliary relay is closed.
Option :
Liters (Default)
CPO AUX RELAY Gallons
Range:
VOLUME: 0001 L 1 to 9999 Liters
1 to 999 Gallons
Note: Only displays on Meter systems
6# and 7#
Page 9
NX Programming
User Parameter Settings Cont. CO N T R O L VA LV E S
Option :
00:01 to 02:00 (HH:MM)
CPO AUX RELAY
TIME: 00:01
Option:
1.0, 1.5, 2.0, 2.5, 3.0 paddle (default)
FLOW METER: Ordinary
Note: Do not display on the lag for System 6#
3.0" PADDLE and 7#
Option :
Liters per minute (Default)
MAXIMUM FLOW Gallons per minute
Range:
RATE: 0091 LPM 20 to 2000liter/minute
20 to 2000gallon/minute
Note: Only displays when choosing Ordinary
Meter
Option :
liters per minute (Default)
ADD 001 LITERS Gallons per minute
Range:
EVERY 001 PULSES 1 to 255 gallons
1 to 255 liters
1 to 255 plus
Note: Only displays when choosing Ordinary
Meter
Page 10
NX Programming
CO N T R O L VA LV E S User Mode Settings.
Hardness Of Water
Option:
Milligrams per liter (Default)
FEED WATER Grains per gallon
HARDNESS:0030mgL
Option:
7 days (Default)
REGENERATION DAY Range:
1 to 99 days
OVERRIDE:07 DAYS
Option :
Off (Default)
REGENERATION DAY Range:
Off, 1 to 99 days
OVERRIDE: OFF
Regeneration Time
Done
Set Time Of Day
Done
Page 11
NX Programming
Diagnostic Mode Setting CO N T R O L VA LV E S
Current flow
CURRENT FLOW
RATE: 0 LPM
Total flow
0 L
Last Regeneration
LAST REGEN:
0 HOURS
Page 12
NX Programming
CO N T R O L VA LV E S Diagnostic Mode Setting Cont.
Valve Address
#2
Software Version
Done
Page 13
NX Features
Regeneration Modes CO N T R O L VA LV E S
When the days since the last regeneration reaches the preset
days, the control starts to regenerate immediately at the preset
11:30 PM 4# regeneration time.
When the volume remaining count down to zero and reach the
preset regeneration time, the control will regenerate immediately.
11:30 PM * 4#
20000 GAL SRV
Mix Regeneration
Under Meter Immediate Regeneration Mode or Meter Delay Regeneration Mode, open the override time setting (default setting under
these two modes is off ), The control will record both the remaining volume and remaining time, the valve starts to regenerate at the time
whenever which reaches first.
Press button during service position, the control will just record
the regeneration time regardless the override days or the remaining
11:30 PM * 4# volume. The display shows the time counting down and WAIT, blue
LED flashes. The control will start to regenerate when the time zeros
01:00 WAIT.. SRV out, press button once again to cancel waiting regeneration.
Page 14
NX Features
CO N T R O L VA LV E S Regeneration Modes Cont.
Press and hold the button at least for 5 seconds during service position, the control will regenerate immediately.
At any step during regeneration, press button to skip the time counting.
Press button and then plug in, the valve will restore to the factory default settings.
Activate the remote signal port and connect the remote signal control as show on the lower right picture. Switch on to initiate the remote
control, the display shows the current time of remote signal and start to count down. Switch off to cancel this function. The control starts
to regenerate when the time of remote signal zeros out. Under timer or meter delay mode, display just shows regeneration time of the day
and count down. Blue light flashes until time zeros out, then control start to regenerate. Under meter immediate mode, control will start to
regenerate right away.
Activate the remote signal port and connect the remote signal control as show on the lower right picture. Switch on to lock the control at
service position. So the control won't be able to regenerate even if it reaches the preset conditions. It remains in waiting position, blue LED
flashes at this time. Switch off then the control will regenerate immediately.
When power fails, current valve status, time at each step, current time can be stored in memory for two weeks and resume when power is
on.
Note: time indicator flashes for 5 minutes when power resumes, press any key to cancel.
Page 15
NX Controller
Assembly & Parts List CO N T R O L VA LV E S
Page 16
DLFC
CO N T R O L VA LV E S Assembly & Parts List
DLFC Buttons
(4 X DLFC)
A-60711
DLFC, 2” NPT
Page 17
AQT-275 Body Valve
Assembly CO N T R O L VA LV E S
Filter Body
14
13
12
9 1
7
8
10
3
11
5
Page 18
AQT-275 Body Valve
CO N T R O L VA LV E S Assembly Parts List
Page 19
AQT-275 Control Drive
Assembly CO N T R O L VA LV E S
1
PN A-60160
Drive Cam Assy
2
30
31 4
9 10 11
8
7
6
29
14
23 13
24
28
27
12
13
17
26
18
20 19
21
25 22
13
15
Page 20
AQT-275 Control Drive
CO N T R O L VA LV E S Assembly Parts List
Page 21
AQT-285 Body Valve
Assembly CO N T R O L VA LV E S
Page 22
AQT-285 Body Valve
CO N T R O L VA LV E S Assembly Parts List
Page 23
AQT-285 Control Drive
Assembly CO N T R O L VA LV E S
PN A-60160
Drive Cam Assy
Page 24
AQT-285 Control Drive
CO N T R O L VA LV E S Assembly Parts List
Page 25
AQT-290 Body Valve
Assembly CO N T R O L VA LV E S
10
11
10
12
13 1
5 4
6
14
2
3
9
15
16
Page 26
AQT-290 Body Valve
CO N T R O L VA LV E S Assembly Parts List
Page 27
AQT-290 Upper Control Drive
Assembly CO N T R O L VA LV E S
1
PN A-60160
Drive Cam Assy
2
33
34 4
9 10 11
8
7
6
32
14
23 13
24
29
28
12
13
17
27
18
20 19
21
26 22
13
7 6
25
15
Page 28
AQT-290 Upper Control Drive
CO N T R O L VA LV E S Assembly Parts List
Page 29
AQT-290 Lower Control Drive
Assembly CO N T R O L VA LV E S
PN A-60160-01
Lower Drive Cam Assy
4 5
6
7
1
8
9
3 4 5
20 6
7
8
9
10
19 12 11
13
18
14
15
17
16
Page 30
AQT-290 Lower Control Drive
CO N T R O L VA LV E S Assembly Parts List
Page 31
AQT-315 Body Valve
Assembly CO N T R O L VA LV E S
4
1
3 7
10
Page 32
AQT-315 Body Valve
CO N T R O L VA LV E S Assembly Parts List
Page 33
AQT-315 Control Drive
Assembly CO N T R O L VA LV E S
37 2
A-16046
KIT
7
4 12
6 8 9 10 11
36
2 34
35 32 33
16 13
29 28 15 14
31 30
23 22 17
24
25
26
23 27 9
18
Page 34
AQT-315 Control Drive
CO N T R O L VA LV E S Assembly Parts List
Page 35
AQT-390 Body Valve
Assembly CO N T R O L VA LV E S
1
6
3 7
2 9
12
13
14
10
15
16
17
18
11 19
Page 36
AQT-390 Body Valve
CO N T R O L VA LV E S Assembly Parts List
Page 37
AQT-390 Upper Control Drive
Assembly CO N T R O L VA LV E S
37 2
A-16046
KIT
7
4 12
6 8 9 10 11
36
2 34
35 32 33
16 13
29 28 15 14
31 30
23 22 17
24
25
26
23 27 9
18
Page 38
AQT-390 Upper Control Drive
CO N T R O L VA LV E S Assembly Parts List
Page 39
AQT-390 Lower Control Drive
Assembly CO N T R O L VA LV E S
A-16046
KIT
3
32 5 6 7
4
31
29 30
28
8
10 9
11
12
27 24 13
26 25 14
15
16
19
12 21 17
23 22
20
18
Page 40
AQT-390 Lower Control Drive
CO N T R O L VA LV E S Assembly Parts List
Page 41
160 Brine System
Assembly CO N T R O L VA LV E S
PN 1 - 23 -------- A-60029 --- Brine Valve, Short Stem, Less BLFC, 3/8” for AQT-275
PN 15 - 23 ------ A-60480 --- Injector Body, 3/8” for AQT-275
16 17 18
5
14 19
6
7 13
12
8 11 20
10
9
21
4
3
2 22
1
23
15
Page 42
160 Brine System
CO N T R O L VA LV E S Assembly Parts List
*** Injectors
A-18272-0 Injector Assy #0, Red (12" and 13" Tank)
A-18272-1 Injector Assy #1, White (14" and 16" Tank)
A-18272-2 Injector Assy #2, Blue (18" Tank)
A-18272-3 Injector Assy #3, Yellow (20" Tank)
Page 43
170 Brine System
Assembly CO N T R O L VA LV E S
PN 1 - 22-------- A-60034 --- Brine Valve, Short Stem, Less BLFC, 1/2” for AQT-285
PN 14 - 22 ------ A-60381 --- Injector Body, 1/2” for AQT-285
19
18
12 17
15
11
20
10
9
21
8
13 16
7
22
6
5
4 14
3
2
Page 44
170 Brine System
CO N T R O L VA LV E S Assembly Parts List
*** Injectors
A-14801-03C Injector Assy, #3C, Yellow (18" & 20" Tank)
A-14801-04C Injector Assy, #4C, Green (21" Tank)
A-14801-05C Injector Assy, #5C, White (24" Tank)
A-14801-06C Injector Assy, #6C, Red (30" and 36" Tank)
Page 45
180 Brine System
Assembly CO N T R O L VA LV E S
PN 1 - 14 -------- A-60277 --- Brine Valve, Short Stem, Less BLFC, 1” for AQT-315 & AQT-390
PN 10 - 14 ------ A-60036 --- Injector Body, 1”for AQT-315 & AQT-390
2
3
4
5
6.1
7
16 8
3
15 5
6.2
9
10
11
12
13
14
Injector*
# 6.1
# 6.2
Page 46
180 Brine System
CO N T R O L VA LV E S Assembly Parts List
*** Injectors
A-15128-04 Injector Assy, #4C, Green (24" Tank)
A-15128-05 Injector Assy, #5C, Red (30" Tank)
A-15128-06 Injector Assy, #6C, White (36" Tank)
A-15128-07 Injector Assy, #7C, Blue (42" Tank)
A-15128-08 Injector Assy, #8C, Yellow (48" Tank)
A-15128-09 Injector Assy, #9C, Violet (54" Tank)
A-15128-10 Injector Assy, #10C, Black (60" - 63" Tank)
Page 47
AQT-275-NXMETER, 1" Meter
Assembly & Parts List CO N T R O L VA LV E S
Page 48
AQT-285-NXMETER, 1.5" Meter
CO N T R O L VA LV E S Assembly & Parts List
Page 49
AQT-290-NXMETER / AQT-315-NXMETER, 2" Meter
Assembly & Parts List CO N T R O L VA LV E S
Page 50
AQT-390-NXMETER, 3" Meter
CO N T R O L VA LV E S Assembly & Parts List
Page 51
Wiring
Diagrams CO N T R O L VA LV E S
For Models:
AQT-275, AQT-285 and AQT-315
Page 52
Wiring
CO N T R O L VA LV E S Diagrams
For Models:
AQT-290 and AQT-390
Page 53
NX Systems
Classification CO N T R O L VA LV E S
Meter Imm All Meters All units in service at the same time. When
one meter zeros out or receives a remote
5#
2-4 signal, that unit starts regenerating. Other
Interlock
units remain in service even if they zero out
Remote Signal Start Optional during this time.
Meter Imm All Meters One unit on stand-by, all units in service.
When one meter zeros out or receives the
9#
2-4 remote start signal, it goes to regeneration
Alternating
and the stand-by one goes to service at the
Remote Signal Start Optional same time.
Page 54
NX Systems
CO N T R O L VA LV E S Installation Diagrams
4# Single Unit
Outlet
Note:
For system 7# and 9#, solenoid valve must be installed at the outlet for
AQT-275, AQT-290, AQT-315. For dual piston AQT-290, AQT-390 this is not
Single Unit necessary. Optional solenoid valve for other systems.
Inlet
System 5#、9#
Outlet
Inlet
System 6#
Outlet
Inlet
System 7#
Flowmeter
Cable
Unit #1 Unit #2
Manual valves
Inlet
Page 55
Troubleshooting
Problems, Cause & Corrections CO N T R O L VA LV E S
Page 56
Troubleshooting
CO N T R O L VA LV E S Example Error Screens
No message #1
DETECTED ERROR
NO MESSAGE #1
No message #2, #3, #4
DETECTED ERROR
NO MESSAGE #2#3#4
No message #2
DETECTED ERROR
NO MESSAGE #2 1) Make sure all communication cables are
connected
No message #3
DETECTED ERROR 2) Keep the same format for the lead unit and
the lag unit
NO MESSAGE #3
3) Confirm there is unit 1# or 2# or 3# set in
No message #4 the system
DETECTED ERROR
4) The number of the control used should
NO MESSAGE #4 comply with the number set in the system
NO MESSAGE #2#3
No message #2, #4
DETECTED ERROR
NO MESSAGE #2 #4
No message #3, #4
DETECTED ERROR
NO MESSAGE #3#4
In system 7, lead unit and Enter the system setting and reset the format
DETECTED ERROR lag unit setting of different for system 7#
format
DIFFERENT FORMAT
Page 57
www.aquatroltech.com
CO N T R O L VA LV E S
LIT-AQT-NX-MAN 10/02/20