Arche 2019 - Column EC2 SP0

Arche 2019 - Column EC2 SP0 © GRAITEC

10/01/20

Date: 03/03/2021 at 09:39

Position : Poteau n011 Niveau n01


Identical columns : 1
Plane : ETAGE 1
Level : 0.000 m

I) Global assumptions

Units Length : Mètre


Force : KiloNewton
Moment : kN*m
Stresses : MegaPa. (N/mm²)
Design according to EUROCODES (AN France)
Longitudinal reinforcement: Nominal stiffness method
Transverse reinforcement: Standard method (§6.2.2, §6.2.3 )
Fck = 25.00 MPa Fyk = 500.00 MPa
Exposure class: XC2
Spec grav of concrete: 2.500 T /m3
Long duration or cyclic loading
R 0

Fluage j(¥, t0) = 2.86 (RH = 50%; t0 = 28 jours)


Concrete covers= 0.050 m
Admissible deviation from required reinforcement area: = 0 %

Second order effects are not negligible.


Design ignoring earthquake.

II) Geometry

Height under slab 2.70 m Height 0.00 m


Height beam 0.30 m
The beam is positioned to the left and right of the column
Offset X dir 0.00 m Offset Y dir 0.00 m

___________ ___________
| | 0.25 RECTANGULAR | | 0.00
|___________| |___________|
0.25 0.00

III) Loads

Calculation report 1

03/03/2021 09h39
Arche 2019 - Column EC2 SP0

Load type Nz Mx My Vx Vy
Dead load 166.5 -1.1 -0.3 -0.3 0.2
Self weight 4.6 / / / /
Imposed 1 21.8 -0.4 0.1 0.1 -0.1
Imposed 2 90.6 -1.1 0.5 0.2 -0.2

IV) Working mode

Design using the Nominal stiffness method


Buckling lengths:
Buckling length X direction 3.00 x 0.87 = 2.60 m
Buckling length Y direction 3.00 x 0.87 = 2.60 m
Slenderness ratios:
Slenderness ratio X direction 36.09
Slenderness ratio Y direction 36.09
Action Effect determinant Load Combinations:
AxTheo Max for +1.35x[G]+1.5x[Q2]
Nu = 361 Moment du 1° ordre : M0Edx = -3 M0Edy = 0
Moment total : MEdx = -24 MEdy = 18
Additional eccentricity : Ea = 0.020 m
1st order eccentricity : E1x = -0.001 E1y = 0.009 m
Required reinf. area : Ax = 2 x 1.31 Ay = 2x 1.31 cm²
Max for +1.35x[G]+1.5x[Q2]
Nu = 367 Moment du 1° ordre : M0Edx = -4 M0Edy = 0
Moment total : MEdx = 10 MEdy = 6
Additional eccentricity : Ea = 0.007 m
1st order eccentricity : E1x = 0.001 E1y = 0.011 m
Required reinf. area : Ax = 2 x 0.00 Ay = 2x 0.00 cm²
Max for +1x[G]
Nu = 171 Moment du 1° ordre : M0Edx = -2 M0Edy = -1
Moment total : MEdx = 5 MEdy = 4
Additional eccentricity : Ea = 0.007 m
1st order eccentricity : E1x = 0.007 E1y = 0.010 m
Required reinf. area : Ax = 2 x 0.00 Ay = 2x 0.00 cm²
Max for +1.35x[G]
Nu = 231 Moment du 1° ordre : M0Edx = -2 M0Edy = -2
Moment total : MEdx = 6 MEdy = 5
Additional eccentricity : Ea = 0.007 m
1st order eccentricity : E1x = 0.007 E1y = 0.010 m
Required reinf. area : Ax = 2 x 0.00 Ay = 2x 0.00 cm²
Useful height on X = 0.187 m
Useful height on Y = 0.187 m

V) Shear force

Along Ox
Design shear force : VSd= -0 kN
Resisting shear force of concrete only : VRd1= 50 kN
Ultimate shear force : VRd2= 236 kN
Resisting shear force : VRd3= 0 kN
Along Oy
Design shear force : VSd= 0 kN
Resisting shear force of concrete only : VRd1= 50 kN
Ultimate shear force : VRd2= 236 kN
Resisting shear force : VRd3= 0 kN

VI) Reinforcement

Calculation report 2

03/03/2021 09h39
Arche 2019 - Column EC2 SP0

Calculation report 3

03/03/2021 09h39
Arche 2019 - Column EC2 SP0
--REQUIRED REINFORCEMENT --

Longit. reinf. required by design: Amin= 1.25 cm² A=5.25 cm² Amax=25.00 cm²
Required longitudinal reinforcement = 5.25 cm²

-- PROVIDED REINFORCEMENT --

CONSIDERED COLUMN

Length of starter bars at bottom L= 0.80 m


Length of provided longitudinal reinforcement L= 2.94 m
Provided reinforcement A=6.16 cm² : 4HA14
Reinforcement required by design A=6.16 cm² : 4HA14
Transverse reinforcement HA 6.0: 14 frames

No starter bar at top

Current column:
Steel binder along a dir: single bar frames
Steel binder along b dir: single bar frames
No starter bar at bottom

VII) Quantities cost

Conventions: h : Height under beam


a : Side in X-direction
b : Side in Y-direction
COLUMNS Sizes (m) Concr Formwork Ratio
Level : 1 h a b m3 mý kg/m3
Linear11 2.70 0.25 0.25 0.169 2.70 97.0

Mean ratio : 96.99 kg/m3


mean diameter: 11.10 mm
Total cost : 175.63 €

VIII) Chronological record

COLUMNS L MESSAGE VALUE LIMIT


T v
A Linear11 1 No error found

Calculation report 4

03/03/2021 09h39