Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

ACCESS DOOR

• On Time Delivery • According to Standard


• Customization • Quality • Cooperation
LA CATALOG REV 00
JANUARY 2019
ABOUT US
Sharqawi Air Distribution Systems Co. Factory, has been in the market
since 1995, as one leading manufacturer in the kingdom of Saudi Arabia
in the field of fabrication of HVAC duct and its Accessories. Upon whose
satisfaction we have been allowed to grow and prosper in this highly
competitive marketplace.
As one of the leading HVAC ducts and its accessories manufacturers, our
reason of ’being’ is a combination of our vision, mission, and values.

Vision:
We aspire making Sharqawi the most trusted manufacturer of HVAC ducts
and its accessories in the Kingdom of Saudi Arabia, region and the world.

Mission:
To aim for design perfection and expanding our market-share by enhancing
our marketing, satisfying customer requirements, complying with the
international quality standards and consistently sustaining our improvement
program.

Values:
Our values reflect who we are and our reason for being.
Quality: We provide exquisite products that deliver exceptional values to our
customer.
Integrity: We boost the highest integrity in all of our activities and
operations.
Customer commitment: we develop positive relationships that make a
beneficial influence on our client’s business.
Teamwork: We work together across boundaries to meet the expectations
of our customers and support the company to win.
A Will To Win: We exhibit a strong will to win in the marketplace and every
aspect of our business.
Respect for people: We value our people, encourage their development
and reword their performance.
Good residents: We are good residents in the communities in which we live
and work.
Personal Accountability: We are personally accountable for delivering on
our commitment.
Access Door

ACCESS DOOR MODELS

LA-A (REMOVABLE) LA-B (PIANO HINGE) LA-C (HINGED) LA-D (INSPECTION COVER)

Installation Options

Fixation On Rectangle Duct Fixation On Round Duct Access Door with Window

Description
ACCESS DOOR [LA-C] LEAKAGE
Access doors are ruggedly designed to suit client 1 INCH DOOR THICKNESS
individual requirements, to provide easy access into air 10
duct, in low to high pressure and velocity ventilation
STATIC PRESSURE, INCH W.G.

systems

Standard Features
• SMACNA Standard Access Door
• DOOR: Consists of 2 Sheets, Mechanically locked
together
• FRAME: Wide range of sizes, MIN (100X100)mm,
MAX (610x610)mm
• CAM: Secured to the door with rivet
1 10 100
• INSULATION: High density fiber glass type
LEAKAGE, CFM/ Ft2

• GASKET: Neoprene Gasket Between frame and


Door to min leakage

1
Access Door

CONSTRUCTION

6 5 2 3
1
A

4
B

WxH
(W+40) x (H+40)

1. Fram 2. Door 3. Cam Lock 4. Sealing Gasket 5. Insulation 6. Hinges


A. Door Thickness B. Neck Length (Default 25 Mm, For Double Wall B= 25+ Wall Thickness)

Number of cam lock and sheet metal gauge as per SMACNA table below (All types except LA-D)

No. Metal Gage


Door Size No. Locks
Hinges Frame Door Back
12”x12” 2 1-S 24 26 26
2” w.g. Static
16”x20” 2 2-S 22 24 26
and less
24”x24” 3 2-S 22 22 26
12”x12” 2 1-S 22 22 26
3” w.g. Static 16”x20” 2 1-S,1-T,1-B 20 20 26
24”x24” 3 2-S,1-T,1-B 20 20 24
4” w.g. 12”x12” 2 1-S,1-T,1-B 20 20 26
to 16”x20” 3 2-S,1-T,1-B 20 18 24

10” w.g 24”x24” 3 2-S,2-T,2-B 18 18 24

S = Side opposite hinges, T = Top, B = Bottom

CONSTRUCTION AND AIRTIGHTNESS MUST BE SUITABLE FOR THE DUCT PRESSURE CLASS USED
REFERENCE: FIGURE 7-2 DUCT ACCESS DOOR AND PANELS,
[SMACNA] HVAC Duct Standards Metal and Flexible. Third Edition

2
Access Door

INSPECTION COVER
LA-D for Mounting on Circular Ducts

ød A B ød A B

80 180 80 355 300 200

100 180 80 400 300 200

112 180 80 450 300 200

125 180 80 500 300 200

140 200 100 560 400 300

150 200 100 630 400 300

160 200 100 710 400 300

180 200 100 800 400 300

200 200 100 900 400 300

224 200 100 1000 500 400

250 200 100 1120 500 400

280 200 100 1250 500 400

315 200 100 All dimensions in mm

Ordering Code Example:


Inspection Cover for Circular Duct with Outer Diameter 500mm:
LA-DMG1N0-500x1

3
Access Door

ASSEMBLY INSTRUCTION

1. Use Access Door To Mark Neck On The Duct 2. Cut The Duct

3. Add Gasket 4. Place The Access Door

5. Open The Door And Bend All Sides Dovetail 6. Close The Door With CAM Lock

4
Access Door

ORDERING CODE

ACCESS DOOR LA - C M G 1 N 0 - 500 x 550


* All selection checkboxes highlighted in blue are the default selections (if not otherwise specified) 1 2 3 4 5 6
MODEL 1

HEIGHT [100-610] mm
WIDTH [100-610] mm
A REMOVABLE B PIANO HINGE

C INDIVIDUAL HINGES D INSPECTION COVER

PRESSURE 2
L 0-2 Inch W.G M 2-4 Inch W.G

H 4-6 Inch W.G

MATERIAL 3
G GALVANIZED STEEL [G90] S STAINLESS STEEL [S304]

B BLACK STEEL

GALVANIZED STEEL [Default G90, Optional (G115, G90 Japan)], STAINLESS STEEL [Default S304, Optional S316]

DOOR THICKNESS 4
1 1 Inch 2 2 Inch

WINDOW 5
N WITHOUT WINDOW W WITH WINDOW

FINISHING 6
0 NO PAINT NO PACKAGING 1 PAINT ONLY

2 PACKAGING ONLY 3 PAINT & PACKAGING

ADDITIONAL OPTIONS
FULL WELD FRAME DOUBLE WALL DUCT THICKNESS [0.5-2.0] Inch

1 FIRE RATED GASKET INSULATION TYPE [1] FIBER GLASS, [2] ROCKWOOL]

1 FIRE RATED PAINT INSULATION DENSITY [DENSITY] kg/m^3

1 FIXATION ON ROUND SURFACE,OUTER DIAMETER (mm) REMOVABLE TYPE WITH CHAIN

CODE DESCRIPTION EXAMPLE (LA-CMG1N0-500x550)


ACCESS DOOR, MODEL INDIVIDUAL HINGES TYPE, PRESSURE 2-4 Inch W.G, MATERIAL GALVANIZED STEEL [G90], DOOR THICKNESS 1 Inch,
FALSE, FINISHING NO PAINT NO PACKAGING , WxH= 500x550mm

5
008

You might also like