2301E Digital Control Manual 26641

Appendix C.
Modbus Communication List

This Modbus Communication List is applicable for software number 5418-6350.

Boolean Writes
Addr Description
0:0001 Reset Control
0:0002 Run
0:0003 Stop
0:0004 Failed Speed Override ON
0:0005 Failed Speed Override OFF
0:0006 Rated Speed Reference
0:0007 Idle Speed Reference
0:0008 Raise Speed / Load
0:0009 Lower Speed / Load
0:0010 Isochronous Mode
0:0011 Droop Mode
0:0012 Load
0:0013 Unload
0:0014 Baseload ON
0:0015 Baseload OFF
0:0016 Select 2nd Dynamics
0:0017 De-Select 2nd Dynamics
0:0018 External / Modbus Shutdown
0:0019 Not Used
0:0020 Not Used
0:0021 Energize Modbus relay #1
0:0022 De-Energize Modbus Relay #1
0:0023 Energize Modbus relay #2
0:0024 De-Energize Modbus Relay #2
0:0025 Energize Modbus relay #3
0:0026 De-Energize Modbus Relay #3
0:0027 Energize Modbus relay #4
0:0028 De-Energize Modbus Relay #4
0:0029 Enable Modbus Control
0:0030 Disable Modbus Control
0:0031 Not Used
0:0032 Not Used

158 Woodward
Manual 26641 2301E Digital Control
Boolean Reads
Addr Description
1:0001 Shutdown Status
1:0002 Alarm Status
1:0003 Overspeed
1:0004 MPU Failure
1:0005 Analog input #1 failure (if configured)
1:0006 Analog input #2 failure (if configured)
1:0007 Test mode active
1:0008 External Shutdown
1:0009 Analog input #1 failure
1:0010 Analog input #2 failure
1:0011 kW input failure PT/CT
1:0012 Load share Input failure
1:0013 Speed PID In-control
1:0014 Start Limiter Active
1:0015 Maximum Fuel Limit
1:0016 Torque Limiter Active
1:0017 MAP Limiter Active
1:0018 Level SW#1 ON
1:0019 Level SW#2 ON
1:0020 Level SW#3 ON
1:0021 Level SW#4 ON
1:0022 Discrete Input A State
1:0023 Discrete Input B State
1:0024 Discrete Input C State
1:0025 Discrete Input D State
1:0026 Discrete Input E State
1:0027 Discrete Input F State
1:0028 Discrete Input G State
1:0029 Discrete Input H State
1:0030 Relay Output #1 State
1:0031 Relay Output #2 State
1:0032 Relay Output #3 State
1:0033 Relay Output #4 State
1:0034 CPU Failure
1:0035 Remote Speed Control State
1:0036 Remote Load Control State
1:0037 Load Share Relay State
1:0038 Run Engine State
1:0039 Stop Engine State
1:0040 Rated Speed State
1:0041 Idle Speed State
1:0042 Raise Speed State
1:0043 Lower Speed State
1:0044 Isoch Mode State
1:0045 Droop Mode State
1:0046 Load Generator State
1:0047 Unload Generator State
1:0048 Baseload Mode State
1:0049 Second Dynamics State
1:0050 Failed MPU Override State
1:0051 Reset Alarms - Shutdown State

Woodward 159
2301E Digital Control Manual 26641
Analog Reads
Addr Description
3:0001 Shutdown first out Indication
3:0002 Alarm first out Indication
3:0003 Engine Speed (RPM)
3:0004 Speed Reference (RPM)
3:0005 Engine load (kW)
3:0006 Actuator Output (%)
3:0007 Speed PID Output (%)
3:0008 Analog Input #1
3:0009 Analog Input #2
3:0010 Speed Bias RPM
3:0011 Engine Load (%)
3:0012 Baseload Reference (kW)
3:0013 Load Bias (RPM)
3:0014 Sync Bias (RPM)
3:0015 Load sharing Bias (%)
3:0016 Remote Speed Setpoint (RPM)
3:0017 Misfire RPM x 1000
3:0018 Power Supply Input

Analog Writes
Addr Description
4:0001 Remote Baseload Reference
4:0002 Remote Speed Reference (Multiply by 10 for better accuracy). If 900 RPM is
required send 9000. The software will divide by 10 if required. Menu Z -

160 Woodward