Design of Concete Mix
Design of Concete Mix
maximum = 50 mm
minimum = 150 mm
3) MIXING WATER & AIR CONTENT
NON-AIR-ENTRAINED CONCRETE
Approximate mixing water (kg/m3) for indicated nominal maximum sizes
of aggregate
37.5 150
Slump (mm) 9.5 mm 12.5 mm 19 mm 25 mm 50 mm 75 mm
mm mm
25 to 50 207 199 190 179 166 154 130 113
75 to 100 228 216 205 193 181 169 145 124
150 to 175 243 228 216 202 190 178 160 -
More than 175 - - - - - - - -
Approximate amount of entrapped air in non-air-entrained concrete (%)
37.5 150
Slump (mm) 9.5 mm 12.5 mm 19 mm 25 mm 50 mm 75 mm
mm mm
All 3.0 2.5 2.0 1.5 1.0 0.5 0.3 0.2
Enter (from Table above) water weight for non-air-entrained concrete = 202kg/m3
4) WATER-CEMENT RATIO
Important! Check the maximum permissible water-cement ratio from the Table
below and revise the water-cement ratio entered in the box above accordingly.
Are pozzolanic materials [such as Fly Ash, Silica Fumes, Ground Granulated Blast-
Furnace Slag (GGBFS)] used in the mix?
* YES, select desired calculation method, and make input in one of the Tables below:
5) COARSE AGGREGATE
Enter unit weight of coarse aggregate (if unknown, use 1500 to 1900 kg/m3 for
normal weight aggregate) = kg/m3
Enter (from Table above) volume of coarse aggregate per unit volume of concrete =
6) FINE AGGREGATE
Enter this
If dosage of water reducer is applied as percentage of cement
percentage
weight, click here
%
If dosage of water reducer is applied as percentage of Enter this
cementitious materials (cement plus pozzolanic materials)
percentage
weight, click here %
Enter percent of reduction in water (as given by the manufacturer) due to applied
dosage of water reducer = %
Slump:
maximum = mm
minimum = mm
Concrete type is
Air content = %