MCX15B Instrukcja

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MAKING MODERN LIVING POSSIBLE

GENERAL FEATURES GENERAL FEATURES AND WARNINGS

PLASTIC HOUSING FEATURES


MCX15B - DIN rail mounting complying with EN 60715
- Self extinguishing V0 according to IEC 60695-11-10 and glowing/hot wire test at 960°C
ANALOG INPUTS according to IEC 60695-2-12
Danfoss Electronics spa NTC, 0/1V, 0/5V 4 - Ball test: 125°C according to IEC 60730-1. Leakage current: ≥ 250V according to IEC 60112
Universal (NTC, Pt1000, 0/1V, 0/5V, 0/10V, ON/OFF, 0/20mA, 4/20mA) selectable via software 6 OTHER FEATURES
Total number 10 - Operating conditions CE: -20T60 / UL: 0T55, 90% RH non-condensing
- Storage conditions: -30T80, 90% RH non-condensing
DIGITAL INPUTS - To be integrated in Class I and/or II appliances
24V optoinsulated 18 - Index of protection: IP40 only on the front cover
230Vac optoinsulated 4 - Period of electric stress across insulating parts: long
Total number 18 - Suitable for using in a normal pollution environment
- Category of resistance to heat and fire: D
ANALOG OUTPUTS - Immunity against voltage surges: category II
0/10Vdc optoinsulated 4 - Software class and structure: class A
PWM, PPM selectable via software 2 CE COMPLIANCE
Total number 6 This product is designed to comply with the following EU standards:
- Low voltage guideline: 73/23/EEC
DIGITAL OUTPUTS - Electromagnetic compatibility EMC: 89/336/EEC and with the follwing norms:
SPDT relay 16A (changeover contacts) 2 - EN61000-6-1, EN61000-6-3 (immunity for residential, commercial and ligth-industrial environments)
SPST relay 8A (normally open contacts) 9 - EN61000-6-2, EN61000-6-4 (immunity and emission standard for industrial environments)
- EN60730 (Automatic electrical controls for household and similar use)
SPDT relay 8A (changeover contacts) 4
Total number 15 UL APPROVAL
UL file: E31024
OTHERS
GENERAL WARNINGS
Power supply 24V AC/20-60V DC • - Every use that is not described in this manual is considered incorrect and is not authorised by the
Power supply 110V/230V AC • manufacturer
Connection for programming key • - Verify that the installation and operating conditions of the device respect the ones specified in the
Connection for remote display and keyboard • manual, specially concerning the supply voltage and environmental conditions
- This device contains live electrical components therefore all the service and maintenance operations
Buzzer •
must be performed by qualified personnel
CANbus • - The device can’t be used as a safety device
RTC clock • - Liability for injury or damage caused by the incorrect use of the device lies solely with the user
MCX15B electronic controller Modbus RS485 serial interface
Dimensions (DIN modules)

16
INSTALLATION WARNINGS
- Mounting position reccomended: vertical
MCX15B is fitted with or without graphic LCD display. Mounting DIN bar - The installation must be executed according the local standards and legislations of the country
- Always operate on the electrical connections with the device disconnected from the main power supply
It is an electronic controller that stands on the top of the - Before carrying out any maintenance operations on the device, disconnect all the electrical connections
MCX range, thanks to the large number of its inputs and - For safety reasons the appliance must be fitted inside an electrical panel with no live parts accessible
- Don’t expose the device to continuous water sprays or to relative humidity greater than 90%.
outputs. It holds all the typical functionalities of MCX Avoid exposure to corrosive or pollutant gases, natural elements, environments where explosives or
controllers: programmability, connection to the CANbus mixes of flammable gases are present, dust, strong vibrations or chock, large and rapid fluctuations in
ambient temperature that in combination with high humidity can condensate, strong magnetic and/or
local network and up to two Modbus RS485 serial radio interference (e.g. transmitting antennae)
communication interfaces. Furthermore it is available in - When connecting loads beware of the maximum current for each relay and connector
- Use cable ends suitable for the corresponding connectors. After tightening the screws of connectors,
REFRIGERATION &
two models, powered at 110-230Vac or 24Vac slightly tug the cables to check their tightness
AIR CONDITIONING DIVISION - Use appropriate data communication cables. Refer to the Fieldbus Installation Guide for the kind of cable to be
used and setup recommendations
MYK connection Modbus RS485 - Reduce the path of the probe and digital inputs cables as much as possible, and avoid spiral paths
enclosing power devices. Separate from inductive loads and power cables to avoid possible

485 electromagnetic noises


- Avoid touching or nearly touching the electronic components fitted on the board to avoid electrostatic
discharges

TECHNICAL SPECIFICATIONS

Danfoss Electronics spa POWER SUPPLY


- 85Vac at 265Vac, 50-60Hz. Maximum power consumption: 26VA. Insulation between power supply and the extra-low voltage: reinforced
Viale Venezia, 59 - 20Vdc at 60Vdc and 24Vac ± 15% 50/60Hz. Maximum power consumption: 12W, 20VA. Insulation between power supply and the extra-low voltage: functional
31020 San Vendemiano
(TV) Italy I/O TYPE NUMBER SPECIFICATIONS I/O TYPE NUMBER SPECIFICATIONS
Digital Relay 15 Concerning the insulation distance there are three groups of relays: Digital 24V optoinsulated 18 DI1 to DI18
Tel: +39 0438 336611 outputs - group 1: relays 1 to 8 inputs Digital Inputs optoinsulated 24Vac 50/60Hz o 24Vdc
Fax: +39 0438 336699 - group 2: relays 9 to 13 230Vac 4 DIH1 to DIH4
- group 3: relays14 to 15 optoinsulated Inputs optoinsulated, 230Vac 50/60Hz. Basic insulation
info@danfosselectronics.com Insulation between relays of the same group: functional - NOTE: when the 230Vac DH1 input is used, the corresponding 24V DI1 input is not available anymore; the same for the
www.danfosselectronics.com Insulation between relays of different groups: reinforced couple of inputs DIH2 and DI2, DIH3 and DI3, DIH4 and DI4
Insulation between relays and the extra-low voltage parts: reinforced Analog 0/10V 4 AO1, AO2, AO3, AO4
Total current load limit: 92A outputs Analog outputs optoinsulated 0/10Vdc 10mA Max for each output
C1-NO1 to C9-NO9 External power supply 24Vac/Vdc
Normally open contact relays 8A: PWM, PPM 2 AO5, AO6
- characteristics of each relay: Analog outputs selectable via software between:
6A 250Vac for resistive loads - 100.000 cycles - pulsing output, synchronous with the line, at modulation of impulse position (PPM)
4A 250Vac for inductive loads - 100.000 cycles with cos(phi) = 0.6 or modulation of impulse width (PWM)
UL: 240Vac - 4A resistive - 3.6 FLA - 21.6 LRA - 346VA pilot duty 30.000 cycles - pulsing output, at modulation of impulse position (PPM) with range 20Hz to 1KHz:
C10-NO10-NC10 to C13-NO13-NC13 open circuit voltage: 6.8V
Changeover contacts relay 8A: minimum load: 1kΩ
- characteristics of each relay: Analog NTC, 0/1V, 0/5V 4 AI7 to AI10
6A 250Vac for resistive loads - 100.000 cycles inputs Analog inputs selectable via software between:
4A 250Vac for inductive loads - 100.000 cycles with cos(phi) = 0.6 - NTC temperature probes, default: 10kΩ at 25°C
UL: 240Vac - 4A resistive - 3.6FLA - 21.6LRA - 346VA pilot duty 30.000 cycles - pressure transducers with 0/5V output
C14-NO14-NC14 to C15-NO15-NC15 Universal 4 AI1 to AI6
High inrush current (80A - 20ms) changeover contacts relay 16A: Universal analog inputs selectable via software between:
- characteristics of each relay: - ON/OFF (current: 20mA)
7A 250 Vac for resistive loads - 100.000 cycles - 0/1V, 0/5V, 0/10V
3.5A 230Vac for inductive loads - 230.000 cycles with cos(phi) = 0.4 - 0/20mA, 4/20mA
UL: 240Vac - 6A resistive - 4.9FLA - 29.4LRA - 470VA pilot duty 30.000 cycles - NTC (10kΩ at 25°C)
- Pt1000
Using of device in case of Tamb = 70°C has to be according to following requirements: 12V+ power supply 12Vdc, 200mA max for 4/20mA transmitter (total on all outputs)
- maximum load admitted for 8A relay: 4A 250Vac 5V+ power supply 5Vdc, 210mA max for 0/5V transmitter (total on all outputs)
- maximum load admitted for 16A relay: 5A 250Vac

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right
to alter its products without notice. This also applies to products already on order provided that such alternations can be made without
subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respecitve
companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved

RI8MR302 - MCX15B instruction sheet - P.N. 3106000420 - 15-310600042A


Produced by Danfoss Electronics spa Graphic Department, 03-2009
CONNECTION DIAGRAM CONNECTIONS

TOP BOARD BOTTOM BOARD TOP BOARD


- Analog output 5-6 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital input 1 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital output 14 connector

(200 mA max)
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²

(70 mA max)

(70 mA max)

(70 mA max)
- Digital output 15 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital input 2 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital input 3 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital input 4 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital input 5-8 connector
5 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital input 9-12 connector
5 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital input 13-16 connector
5 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital input 17-18 connector

MCX15B - BOTTOM
4 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²

MCX15B - TOP
BOTTOM BOARD
- Analog output 5-6 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital output 1-5 connector
10 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital output 6-8 connector
6 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Analog input 1-6 connector
11 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Analog input 7-10 connector
6 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Power supply connector

D1-
2 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital output 9-12 connector
11 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Digital output 13 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- Analog output 1-4 connector
6 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- RS485-2 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- RS485 connector
3 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- CAN connector
4 way screw plug-in connector type pitch 5mm: section cable 0.2-2.5mm²
- CAN-RJ connector
6/6 way telephone RJ11 plug type
*NOTE: connection has to be made on the first and last local network units, make the connection as close as possible to the connector
**NOTE: optoinsulated analog outputs voltages are referenced to contact N1

MAKING MODERN LIVING POSSIBLE

DIMENSIONS USER INTERFACE

Danfoss Electronics spa


LCD display No display LCD DISPLAY
- display mode: STN blue transmissive
- backlight: white LED backlight adjustable via software
- display format: 128x64dots
- active visible area : 58x29mm
- contrast: adjustable via software
KEYBOARD
- number of keys: 6
- keys function is settled by the application software
110

280 63 60

MCX15B electronic controller PRODUCT PART NUMBERS

CODE DESCRIPTION
080G0088 MCX15B, 24V, LCD, RTC, S
080G0089 MCX15B, 230V, LCD, RTC, S
080G0036 MCX15B, 24V, LCD, RS485, RTC, S
080G0037 MCX15B, 230V, LCD, RS485, RTC, S
080G0053 MCX15B, 24V, LCD, 2XRS485, RTC, S
080G0054 MCX15B, 230V, LCD, 2XRS485, RTC, S

REFRIGERATION & 080G0090 MCX15B, 24V, RTC, S


AIR CONDITIONING DIVISION
080G0091 MCX15B, 230V, RTC, S
MYK connection Modbus RS485 080G0042 MCX15B, 24V, RS485, RTC, S
080G0043 MCX15B, 230V, RS485, RTC, S
485 080G0055
080G0056
MCX15B, 24V, 2XRS485, RTC, S
MCX15B, 230V, 2XRS485, RTC, S

You might also like