Easy Graphic User Interface – Starting Configuration Communication with the sensor occurs via the Ethernet network. Supply voltage (Vs): 24 Vdc ± 10%
DataVS2 sensor requires a preliminary setting: this is made in 3 steps by Direct connection: personal computer is connected directly to device using a Ripple voltage: 1 Vpp max with illuminator
using the Easy GUI interface. "cross cable". 2 Vpp max without illuminator
Current draw with illuminator:
(depends on how long max 200 mA at 24 VDC
DataVS2-xx-DE-AOR/OBJ-x illuminator stays on)
Vision Sensor Outputs: 4 PNP outputs (short circuit protection)
(Output 4 is configurable as
Warning: in case of direct connection the PC requires a fixed IP External Illuminator Strobe)
address
Output current: 100 mA max
QUICK REFERENCE GUIDE After the start-up of the program, the user is asked to establish a connection
to the sensor: Through LAN: use common network (non-cross) cables normally used to
Output saturation voltage: <2V
Find sensor: research of the sensors Network interface: M12 4 poles – 10/100 Mbps Ethernet
connect devices to routing hubs.
MINIMUM SYSTEM REQUIREMENTS connected to the network Optics: Integrated
Connect to: connection to the last sensor Resolution: 640 × 480 (VGA)
Check that your Personal Computer meets the following minimum
you have worked with Dimensions: 69.8 × 51.5 × 40 mm
requirements for system interfacing:
Offline: open a working session without Indicators: 4 LED
Pentium 1,7 GHz processor
sensor Setup: 1 Teach-In button
1 GB of RAM
If the sensor found is displayed in red, select Configure and follow Data retention: Non-volatile FLASH memory
Monitor SVGA (1024x768 pixel)
the instructions Operating temperature: -10 °C … +55 °C
Network Connection board 10/100 Mbps
Step 1: Image Setup Storage temperature: -25 °C … +75 °C
50 MB Hard Disk drive free space
The first step allows to handle the connection to the sensor and set the The sensor has the following default IP address: Vibrations: 14 mm @ 2 to 10 Hz;
parameters related to the image quality. Once achieved the desired result, the IP Address: 172.27.101.208 (EN60068-2-6) 1.5 mm @ 13 to 55 Hz;
For best performances the following requirements are recommended:
image can be saved and set as reference for the sensor operations Subnet mask: 255.255.0.0 2 g @ 70 to 200 Hz; 2 hours on each axis
Pentium 2 GHz processor
2 GB of RAM - Online/Offline selection Shock resistance: 11 ms (30 G) 6 shock for every axis
HARDWARE CONNECTIONS (EN60068-2-27)
Monitor resolution 1280x768 at least
- Select a Task: create a new inspection or open Housing material: Aluminium alloy / ABS
Network Connection board 100 Mbps M12 8 Poles (Power and I/O)
an existing inspection from the PC or from the Mechanical protection: IP50
60 MB Hard Disk drive free space sensor
Note: It is not permitted to disconnect the cable at the Connections: M12 8 pole A-code, M12 4 pole D-code
DESCRIPTION - Set Reference Image: save the image as connector Power and I/O while it is under power. Weight: 125 g
reference for the following steps
The DataVS2 series of vision sensors offers the easiest way to solve the most Step 2: Teach MECHANICAL DIMENSIONS
common machine vision applications.
In this step you may configure the desired control.
-Compact IP50 housing - Select Locator: a locator is a special Tool Power: Brown
allowing the sensor to find the object inside the Voltage: 24 VDC ± 10%
-Integrated light LED illuminator image. Once the control is chosen it is added to
Vs
Current: 200 mA max
-Selectable lens current inspection. It is possible to add at most Blue
-Focus ring one locator to current inspection
White
-Standard M12 connectors - Select Control: It allows selecting the controls Inputs:
that will be added to the inspection process. Once Input ON: > 20 VDC
Vs Insp. Selection
-Teach button the control is chosen it is added to current Input OFF: < 2 VDC
-Image sensor 640x480 pixel inspection. It is possible to add more than one
control to current inspection. Red
- Output Setup : configuration of the 4 digital Vs Ext. Trigger
..
outputs.
After selecting the control, it’s necessary to position it on the reference image,
by clicking in the working area and by moving and resizing the ROI. Outputs:
Yellow
The Control Panel displays the control’s parameters, initialized to standard 4 x PNP transistors with OUT 1
ELECTRIC CONNECTIONS values: it is possible to modify them by using the sliders or by directly writing short circuit protection
.. ..