PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK

BILL NO. 8

ANCILLARY BUILDINGS

Item Description Unit Qty. Rate Amount (RM)

This Bill consists of the following Sections:-

1. Pump House

2. Electrical Building

Notes:
The preambles and notes contained in the
previous Bills shall apply equally to the relevant
works contained in this Bill.

The Contractor is to refer to the relevant


sections of the Specifications, Notes,
Preambles To All Trades and Drawings
applicable to the works contained in this Bill.

Where work contained in one section is similar


to another section in this Bill, the Preambles
written for the preceding section shall also
apply to the section following.

Wherever the item with unit rate of "Lump Sum"


or "Item" appears in this Bill, the amount inserted
is firm and shall not be subject to any variation or
re-measurement on site. No claims in whatever
ways will be entertained.

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/1


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

SECTION 1 - PUMP HOUSE

Item Description Unit Qty. Rate Amount (RM)

WORK BELOW LOWEST FLOOR FINISHES

Excavation

The Following Excavation Has Been Measured


From Proposed Platform Level

Note:-

The Contractor is to take careful note of the


platform levels, slopes, drainage system and
other features as depicted in the Contract
Survey Plans and site visits and to account for
any additional earthworks in trimming, cutting
and filling (including importing or removal of
earth) or any works necessary to the existing
site to make up the required platform levels and
works to be carried out as shown in the Contract
Drawings and Specification as deemed
necessary and shall allow for all costs
necessary thereon as described . No claims
shall be entertained for lack of account for
existing site conditions.

A Excavate for raft foundation cum ground slab


maximum depth not exceeding 0.35 m, get out,
part return, fill in and well ram and remainder
cart away as described M3 7

B Excavate for apron slab maximum depth not


exceeding 0.25 m, ditto M3 15

C Excavate for ramp slab maximum depth not


exceeding 0.25 m, ditto M3 1

Hardcore As Described

D 300 mm Thick bed of hardcore blinded with


sand, spread, levelled, watered, well compacted
and consolidated to receive ground slab
(measured separately) M2 9

E 300 mm Thick bed of hardcore, spread, levelled,


watered, well compacted and consolidated to
receive apron slab M2 21

F 150 mm Thick bed of hardcore blinded with


sand, spread, levelled, watered, well compacted
and consolidated to receive ramp slab
(measured separately) M2 2

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/2


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

WORK BELOW LOWEST FLOOR FINISHES


(CONT'D)

Approved Anti-Termite Treatment As


Described

A Prepare and apply "Termite Syn" or equal and


approved anti-termite treatment to top surfaces
receiving apron slab and ground slab M2 65

Polythene Damp-Proof Membrane As


Described (Measured Nett, Rate To Include
For Laps And Joints)

B 0.20 mm Thick polythene damp-proof membrane


laid under ground slab M2 10

Concrete Works

Lean Concrete (Grade 15) As Described In

C Blinding laid under ground slab not exceeding


50 mm thick M3 1

D Blinding laid under apron slab not exceeding


50 mm thick M3 1

E Blinding laid under ramp slab not exceeding


100 mm thick M3 1

Vibrated Reinforced Concrete (Grade C30/37,


With Minimum Cement Content 300 Kg/M3 And
Maximum Free Water Cement Ratio 0.55 As
Specified) As Described In

F Ground slab exceeding 300 mm thick M3 4

G Apron slab 150 mm - 300 mm thick M3 7

H Plinth 150 mm - 300 mm thick M3 1

J Ramp slab not exceeding 100 mm thick M3 1

Fabric Mesh Reinforcement As Described


(Measured Nett, Rate To Include For
250 mm Minimum Laps And Intersections)

K BMC A8 laid in ground slab M2 19

L BMC A8 laid in apron slab M2 41

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/3


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

WORK BELOW LOWEST FLOOR FINISHES


(CONT'D)

Fabric Mesh Reinforcement As Described


(Measured Nett, Rate To Include For
250 mm Minimum Laps And
Intersections) (Cont'd)

A BMC A8 laid in plinth M2 2

B BRC A7 laid in ramp slab M2 2

Sawn Formwork As Described To

C Edge of concrete 250 mm - 500 mm high M 13

D Sides of plinth 250 mm - 500 mm high M 22

E Edge of ramp slab not exceeding 250 mm high M 7

FRAME

Concrete Works

Vibrated Reinforced Concrete (Grade C30/37,


With Minimum Cement Content 300 Kg/M3 And
Maximum Free Water Cement Ratio 0.55 As
Specified) As Described In

F Column M3 2

G Roof beam M3 1

High Tensile Deformed Bar Reinforcement


As Described

Note:-

Refer to note as described elsewhere in this Bill.

In Column

H 10 mm Diameter bar as link Kg 55

J 20 mm Diameter bar Kg 192

In Roof Beam

K 10 mm Diameter bar as link Kg 52

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/4


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

WORK BELOW LOWEST FLOOR FINISHES


(CONT'D)

High Tensile Deformed Bar Reinforcement


As Described (Cont'd)

In Roof Beam

A 12 mm Diameter bar Kg 22

B 16 mm Diameter bar Kg 39

Sawn Formwork As Described To

C Sides of column M2 16

D Sides and soffit of roof beam M2 13

Roof Covering

"Asteel EnvioClean Ashin" Metal Shingles


Roofing Or Equal And Approved 0.48 mm
Total Coated Thickness (TCT) Concealed Fix
Metal Roofing Sheet Including All
Necessary Fixing Components And
Accessories, All Straight, Skew And Circular
Cutting At Eaves, Verges, Top Edges, Hips
And Valley, Etc. To Suit Roof Profile, All To
The Manufacturer's Instruction And
Architect's Approval (Measured Nett, Rate
To Include For Laps, Cutting And Wastages)

E Roofing sheet fixed to fall at 23º pitch on steel


framing (measured separately) M2 33

F Standard ridge capping including notching


edges to fit profile of roofing sheet, all
constructed with and including all necessary
accessories M 6

Insulation Blanket As Described

G Approved fibreglass insulation blanket laid on


aluminium foil (measured separately) M2 33

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/5


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Aluminium Foil As Described

A Approved double sided air sisalation aluminium


foil, laid and lapped 150 mm at joints and sealed
with and including approved adhesive jointing
tape or similar approved materials (measured
nett, rate to include for laps, adhesive tape, etc.) M2 33

Wire Mesh As Described

B 50 mm x 50 mm Chicken wire mesh of


approved gauge lapped 150 mm at joints and
secured to roof framing (measured nett, rate to
include for laps, etc.) M2 33

Waterproof Plywood As Described

C Approved 12 mm thick waterproof plywood as


roof underlay for metal roofing fixed to steel
structure (measured separately) with and
including all necessary fixing accessories M2 33

Prefabricated Cold Formed Steel Roof


Trusses System And Associated Roof
Structure

Notes:-

i) The contrator shall design, fabricate and


deliver to site and furnish at his expense all
necessary materials, tools, hoist, staging,
temporary bracing etc. for the safe and
proper erection of the prefabricated roof
trusses (PRT) complete with rafters, top and
bottom chords, bracings and tie-down,
struts, bearers, truss connectors, straps,
wall plates, connections, other associated
ancillary fixing products and methods and
obvious item required for the works to
ensure all items act together as an integral
structure that is structurally stable under all
the specified combinations of loading
conditions, all to the approval of the SO

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/6


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Prefabricated Cold Formed Steel Roof


Trusses System And Associated Roof
Structure (Cont'd)

Notes:- (Cont'd)

ii) The design of the PRT roof trusses shall be


by AN APPROVED SYSTEM PROVIDER
(S.P) BY JKR and fabricated by a fabricator
as defined and in accordance with either
JKR-20601-0186-11-SPECIFICATION
PREFABRICATED COLD FORMED STEEL
ROOF TRUSSES or JKR-20601-0190-12-
SPECIFICATION PREFABRICATED
TIMBER ROOF TRUSSES and Architect's
drawings. The list of the approved S.P is
specified in the Appendix of the
specification.

iii) The Contractor shall note the PRT roof


trusses shall be designed to suit the
ceiling, roof coverings, mechanical &
electrical (M&E) services and whatever load
deem necessary to provide the functional
purpose of the building.

iv) The water tank will need to be supported


separately In the case where PRT roof
trusses are designed at centres which do
not suit or facilitate the fixing of the ceiling ,
the Contractor shall include in his design of
the PRT roof trusses for any additional
bearers, tie-beams, ceiling joist, etc.
required to facilitate the ceiling panels. The
contractor shall also in his design, facilitate
the fixing of timber rafters and its
components used as an architectural
feature along the eaves of the PRT roof
trusses.

v) The Contractor shall ensure that all truss


member located on the ducting brackets
shall be protected with rubber pad to reduce
the vibration caused by ducting. Rod to
support ducting shall be installed on web
plane member (stronger axis to decrease
twisting on truss member). Drilling is strictly
prohibited on all truss member. M&E
services shall be installed using strap.

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/7


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Prefabricated Cold Formed Steel Roof


Trusses System And Associated Roof
Structure (Cont'd)

Notes:- (Cont'd)

vi) The Contractor shall note that he shall be


solely responsible for the adequacy and the
sufficiency of the PRT roof trusses.

Rates to incude

Rates for the PRT roof trusses and rafters shall


include for all necessary materials, fabricating,
delivery to site, hoisting and fixing in position, all
fixing accessories including holding down bolt or
ram setting, all ancillary item and temporary
works for the complete installation of the PRT
roof trusses.

Rates for the PRT roof trusses shall also include


for design fees, testing for compliance, quality
assurance and control and all other necessary
cost for paten right design, trademark or name.

A Provide design, structural calculations, shop


drawings, etc. with PE endorsement as
stipulated in the Specification ITEM ---

Design, Supply, Fabricated And Deliver To Site


Cold Formed Steel Roof Trusses/Timber Roof
Trusses Including Fixing And Hoisting Position
All Fabricated PRT, Rafters, Chords, Bearers,
Tie-Down And Bracings, Struts, Wall Plate
Connectors And Fixings, Straps Other
Associated Ancillary Fixing Products And Other
Associated Works, Materials And Labour
Required For The Complete Installation Of The
PRT Roof Trusses To The Approval Of The S.O.

B Roof, fall at 23º pitch M2 33

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/8


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Roof And Fascia Framing

Sawn Hardwood

A 200 mm x 20 mm Fascia board M 23

EXTERNAL WALLS

Wet Wall System As Described

"Asteel Ajiya AGiBS" Or Equal And Approved


Wet Wall System With C&U Sections Galuzinc
Coated Steel, 0.44 mm Thick Zinc Coated Steel
Mesh With Grade 15 Mortar Infill All As Per
Drawings And Constructed In Accordance To
The Manufacturer's Instruction And
Specifications

B 107 mm Thick wet wall system M2 36

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/9


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

DOORS

Notes:-

All sawn timber are to be treated with two coats


of approved wood preservative and rates for sawn
timber are to include for above.

All timber frames abutting concrete or brickwork


shall be primed before fixing and assembling.
Rates for all door frames are to include for
priming frames with one coat of approved wood
primer sealer.

Rates for all timber door frames are to include


for mild steel holdfast as described.

Rates for all door frames shall include for filling


voids of approved materials in between framing
and brickwall or concrete wall as deemed
necessary by the S.O.

All fire-rated doors and door frames must be


constructed to the requirement and approval of
BOMBA and rate for fire-rated doors and door
frames shall include for above.

Roller Shutter

A Approved anodised aluminium roller shutter,


overall size 3900 mm x 2950 mm high complete
with all necessary fittings and fixing accessories,
all as per Manufacturer's instructions and
specification
(Type RS1) NO 1

WINDOWS

Notes:-

Rates for all window frames shall include for


filling voids of approved materials in between
framing and brickwall or concrete all as deemed
necessary by the S.O.

Sundry labour items like drip groove, throating,


rounded coves and external angles, V-grooves
and arises are not measured separately and
rates for plastering are to include for these
sundry labour items.

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/10


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

WINDOWS (CONT'D)

Approved Bronze Anodised Finish


Aluminium Windows Complete With Frame,
All Necessary Gaskets, Weatherstrips,
Sealers, Brackets, Straps, Tapping Screws,
Mastic, Hardwood Packing And Setting
Blocks, Approved Waterproof Silicone
Sealant Compound Pointing To Aluminium
Base And Side Sections, Fittings, Etc. And
Approved Ironmongery All Constructed As
Per Detailed Drawings And To The
Satisfaction Of The S.O.

Aluminium Framed Fixed Clear Glass Louvres


Cum Fixed Glass Louvres Window
(Glazing Measured Separately)

A Aluminium framed fixed clear glass louvres cum


fixed glass louvres window complete with
anti-mosquito netting, overall size 1800 mm x
600 mm high in three equal panels, all
constructed as per detailed drawings
(Type W1) NO 1

The Following In Framed And Welded


Galvanised Mild Steel Security Grille
Including All Necessary Shop And Site
Welding In Fillet Or Full Strength Butt Weld,
Filing Smooth Junctions, Raking And
Tapering Cutting, Hoisted And Installed In
Position, All Constructed As Per Detailed
Drawings And To The Satisfaction Of The
S.O.

B Galvanised mild steel grille window, overall size


1660 mm x 600 mm high in three equal panels
complete with frame, all constructed as per
detailed drawings
(Type WG1) NO 1

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/11


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

WINDOWS (CONT'D)

Painting As Described

Prepare, Sand Smooth And Apply One Coat Of


Approved Anti-Corrosion Primer, One Coat Of
Approved Undercoat And Two Finishing Coats
Of Approved Gloss Enamel Paint On The
Following Metal Surfaces

A Surfaces of mild steel grille window (measured


flat overall) M2 1

Glazing As Described

6 mm Thick Approved Clear Glass Louvered


Blade With Grounded And Polished Edges
And Fixed To The Aluminium Louvre Slot
Framing (Measured Separately)

B 150 mm Wide with both ends fixed into slot of


framing
(In 12 No.) M 1

FLOOR FINISHES

Note:-

All circular, raking and tapering cutting as


deemed necessary to all types of tiles laying
around pipes, floor grating, sanitary fittings and
junctions with floors and walls, etc. are not
measured separately. Rates for tiling are to
include for above cutting and waste.

25 mm Thick Cement And Sand (1:3) Paving


As Described And Finished With Steel
Trowel To

C Floor M2 10

D Apron slab, laid to fall M2 21

E Ramp slab including forming 10 mm x 10 mm


herringbone groove line at 300 mm gap apart M2 2

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/12


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

FLOOR FINISHES (CONT'D)

Waterproofing System

Prepare And Apply "Sika" Or Equal And


Approved Polyurethane Waterproofing
Membrane System With 10 Years Warranty
From The Date Of Certificate Of Practical
Completion Including Forming All Necessary
Angle Fillet And Inclusive Of 150 mm High
Upturn At Wall, All In Accordance To The
Manufacturer's Instruction And Specification And
To The Satisfaction Of The S.O. As Described
To

A Floor M2 10

Ponding Test As Described

B Allow for carrying out Ponding Test to all


waterproofing system including all necessary
preparation, equipment and to the satisfaction
of the S.O. ITEM ---

WALL FINISHES

Notes:-

All circular, raking and tapering cutting as


deemed necessary to all types of tiles laying
around pipes, sanitary fittings, light fittings and
junctions with floors and walls, etc. are not
measured separately. Rates for tiling are to
include for above cutting and waste.

Sundry labour items like drip groove, throating,


rounded coves and external angles, V-grooves
and arises are not measured separately and
rates for plastering are to include for these
sundry labour items.

12 mm Thick External Plastering In Two


Coats As Described To

C Sides of wet wall system M2 36

D Sides of column M2 8

E Sides of roof beam M2 6

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/13


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

WALL FINISHES (CONT'D)

12 mm Thick Internal Plastering In Two


Coats As Described To

A Sides of wet wall system M2 36

B Sides of column M2 8

Painting As Described

Prepare, Seal And Apply One Coat Of Approved


Alkali Resisting Primer And Two Finishing Coats
Of Approved Acrylic Paint On The Following
External Surfaces

C Platered sides of wet wall system M2 36

D Plastered sides of column M2 8

E Plastered sides of roof beam M2 6

Prepare, Seal And Apply One Coat Of Approved


Alkali Resisting Primer And Two Finishing Coats
Of Approved Emulsion Paint On The Following
Internal Surfaces

F Plastered sides of wet wall system M2 36

G Plastered sides of column M2 8

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/14


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

CEILING FINISHES

Notes:-

Rates shall include for forming openings for light


fittings, air-conditioner grilles, etc. and shall
further include for all types of cutting to the
required length and sizes, trimming around
openings, columns, etc. and waste. Rates shall
also include for additional timber framing and
framing for suspension system to the above. The
Contractor shall submit shop drawings for
approval.

Rates shall also include for ramset anchors or


bolting or other fixing accessories to soffit of
concrete slab.

Rates shall include for replacing soiled or spoilt


boards and for touching up.

The Contractor shall coordinate the orientation of


suspended ceiling with the lighting layout.

Rates for suspension system shall include for all


pins, hangers, runners, cover angles, wall
angles, corner beads, angle beads and all other
accessories.

Rates for ceiling board shall include for


accessories to prevent sagging of board such as
diagonal bracing of board, etc.

All sawn timber are to be treated with two coats


of approved wood preservative and rate for sawn
timber are to include for above.

Sundry labour items like drip groove, throating,


rounded coves and external angles, V-grooves
and arises are not measured separately and
rates for plastering are to include for these
sundry labour items.

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/15


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

CEILING FINISHES (CONT'D)

Cement Board Ceiling As Described

A 1200 mm x 1200 mm x 3.2 mm Thick selected


cellulose fibre cement board ceiling lining fixed
to 100 mm x 50 mm hardwood joists at
1200 mm centres, 50 mm x 50 mm hardwood
runner at 600 mm centres with and including
75 mm x 50 mm timber hanger at 1200 mm
centres, all to the approval of the S.O. M2 30

Painting As Described

Prepare, Seal And Apply One Coat Of Approved


Alkali Resisting Primer And Two Finishing Coats
Of Approved Acrylic Paint On The Following
External Surfaces

B Surfaces of cement board ceiling to roof eave


(measured flat overall) M2 21

Prepare, Seal And Apply One Coat Of Approved


Alkali Resisting Primer And Two Finishing Coats
Of Approved Emulsion Paint On The Following
Internal Surfaces

C Surfaces of cement board ceiling (measured flat


overall) M2 9

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/16


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

PLUMBING SYSTEM

INTERNAL COLD WATER SUPPLY SYSTEM


(ALL PROVISIONAL)

Notes:-

All short lengths, sockets, connectors,


backnuts, elbows, bends, firenuts, tees,
diminishing pieces, reducers and plugs and
the like of all piping work are not measured
separately.

Rates for piping work are to include for the


above.

All water supply pipes are to be chased into the


wall and rate to also include for chasing pipe into
the wall top conceal the piping and make good,
unless the piping runs through ducts as
indicated on the drawings.

Rates for piping work shall also include for


forming holes through slabs and walls including
all approved pipe sleeve and mastic compound
as required, working in confined spaces and
testing of pipes and fittings to conform to
requirements as directed by Architect/Engineer.

Complete Supply, Delivery, Installation And


Connection Of Above Ground Cold Water
Pipings Including Elbows, Bends, Tees, Ends,
Pipe Sleeves And All Other Necessary Fittings,
Hacking On Brickwall For Concealed Piping,
Labelling, Painting And Finishing Works As
Specified And As Shown On Drawings

A 25 mm Diameter Polyproplylene Random


Copolymer (P.P.R) pipe M 8

B 20 mm Diameter stop valve NO 1

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/17


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Item Description Unit Qty. Rate Amount (RM)

PLUMBING SYSTEM (CONT'D)

INTERNAL SANITARY PLUMBING


(ALL PROVISIONAL)

Notes:-

When pipes are to be chased into the wall, the


Contractor shall include in his rate for chasing
pipe into the wall to conceal the piping and
make good, unless the piping runs through
ducts as indicated on the drawings.

Rate for piping work shall also include for


forming holes through slabs and walls including
all approved pipe sleeve and mastic compound
as required and working in confined spaces.

Complete Supply, Delivery, Installation And


Connection Of Soil, Waste And Vent Pipings
Laid Underground Floor Slab And Apron Slab
Inclusive Of Fittings, Pipe Sleeves, Necessary
Excavation And Connection To Sewage
Manholes, Drain, Sump And All Other
Necessary Accessories As Specified And As
Shown On Drawings:-

A 50 mm Diameter Unplasticised Polyvinyl


Chloride (U.P.V.C.) pipe M 5

B 50 mm Diameter floor trap NO 1

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/1/18


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Amount (RM)

COLLECTION

From Page No. ….. 8/1/1

From Page No. ….. 8/1/2

From Page No. ….. 8/1/3

From Page No. ….. 8/1/4

From Page No. ….. 8/1/5

From Page No. ….. 8/1/6

From Page No. ….. 8/1/7

From Page No. ….. 8/1/8

From Page No. ….. 8/1/9

From Page No. ….. 8/1/10

From Page No. ….. 8/1/11

From Page No. ….. 8/1/12

From Page No. ….. 8/1/13

From Page No. ….. 8/1/14

Carried Forward ... RM

kubs-Bill 8 -Ancillary Buildings 8/1/19


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 1 - Pump House

Amount (RM)

COLLECTION Brought Forward …

From Page No. ….. 8/1/15

From Page No. ….. 8/1/16

From Page No. ….. 8/1/17

From Page No. ….. 8/1/18

Section 1 - Pump House


Total Carried To Summary RM

kubs-Bill 8 -Ancillary Buildings 8/1/20


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

SECTION 2 - ELECTRICAL BUILDING

Item Description Unit Qty. Rate Amount (RM)

WORK BELOW LOWEST FLOOR


FINISHES

Excavation

The Following Excavation Has Been Measured


From Proposed Platform Level

Note:-

The Contractor is to take careful note of the


platform levels, slopes, drainage system and
other features as depicted in the Contract
Survey Plans and site visits and to account for
any additional earthworks in trimming, cutting
and filling (including importing or removal of
earth) or any works necessary to the existing
site to make up the required platform levels and
works to be carried out as shown in the Contract
Drawings and Specification as deemed
necessary and shall allow for all costs
necessary thereon as described . No claims
shall be entertained for lack of account for
existing site conditions.

A Excavate for raft foundation cum ground slab


maximum depth not exceeding 0.25 m, get out,
part return, fill in and well ram and remainder
cart away as described M3 380

B Excavate for apron slab maximum depth not


exceeding 0.25 m, ditto M3 33

C Excavate for ramp slab maximum depth not


exceeding 0.25 m, ditto M3 10

Hardcore As Described

D 150 mm Thick bed of hardcore, spread, levelled,


watered, well compacted and consolidated to
receive apron and ramp slab (measured
separately) M2 70

E 300 mm Thick bed of hardcore, spread, levelled,


watered, well compacted and consolidated to
receive raft foundation (measured separately) M2 195

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/1


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

WORK BELOW LOWEST FLOOR


FINISHES (CONT'D)

Sandfilling

A Selected and approved well compacted


sandfilling below ground slab M3 108

Approved Anti-Termite Treatment As


Described

B Prepare and apply "Termite Syn" or equal and


approved anti-termite treatment to top surfaces
receiving apron slab and ground slab M2 250

Polythene Damp-Proof Membrane As


Described (Measured Nett, Rate To Include
For Laps And Joints)

C 0.20 mm Thick polythene damp-proof membrane


laid under ground slab and sides of ground beam M2 230

Concrete Works

Lean Concrete (Grade 15) As Described In

D Blinding laid under raft foundation not exceeding


100 mm thick M3 10

E Blinding laid under apron slab not exceeding


100 mm thick M3 3

F Blinding laid under ramp slab not exceeding


100 mm thick M3 1

Vibrated Reinforced Concrete (Grade C30/37,


With Minimum Cement Content 300 Kg/M3 And
Maximum Free Water Cement Ratio 0.55 As
Specified) As Described In

G Raft foundation M3 117

H Stump M3 2

J Ground slab 100 mm - 150 mm thick M3 15

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/2


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

WORK BELOW LOWEST FLOOR FINISHES


(CONT'D)

Concrete Works (Cont'd)

Vibrated Reinforced Concrete (Grade C30/37,


With Minimum Cement Content 300 Kg/M3 And
Maximum Free Water Cement Ratio 0.55 As
Specified) As Described In (Cont'd)

A Apron slab 150 mm - 300 mm thick M3 17

B Ramp Slab 150 mm - 300 mm thick M3 4

C Trench wall M3 40

High Tensile Deformed Bar Reinforcement


As Described

Note:-

Contrary to the provision in the Standard Method


Of Measurement, hooks and cranks for high
tensile deformed reinforcement bar and mild
steel reinforcement bar are not measured
separately. Therefore, the above-mentioned
items shall be included in the rates.

In Stump

D 10 mm Diameter bar as link Kg 70

In Raft Foundation

E 16 mm Diameter bar Kg 1,620

F 20 mm Diameter bar Kg 2,580

In Stump

G 20 mm Diameter bar Kg 551

In Trench Wall

H 12 mm Diameter bar Kg 1,471

J 20 mm Diameter bar Kg 5,594

In Apron

K 12 mm Diameter bar as starter bar Kg 148

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/3


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

WORK BELOW LOWEST FLOOR


FINISHES (CONT'D)

High Tensile Deformed Bar Reinforcement


As Described (Cont'd)

In Ramp

A 12 mm Diameter bar as starter bar Kg 127

Fabric Mesh Reinforcement As Described


(Meaasured Nett, Rate To Include For
250 mm Minimum Laps And Intersections)

B BMC A10 laid in ground slab M2 240

C BMC A7 laid in apron slab M2 55

D BMC A7 laid in ramp slab M2 15

Sawn Formwork As Described To

E Edge of concrete not exceeding 250 mm high M 63

F Edge of concrete 500 mm - 1.00 m high M 63

G Sides of stump 500 mm - 1.00m high M 17

H Sides of trench wall M2 312

J Edge of ramp slab not exceeding 250 mm high M 32

K Sides of apron slab 500 mm - 1.00 m high M 102

MISCELLANEOUS TEST

Note:-

Miscellaneous tests shall be deemed to include


plant movements on the site.

L Carry out Mackintosh Probe Test as per


Drawing requirement or specification to
ascertain the bearing capacity of soil SUM --- ---

M Carry out Plate Bearing Test to two times


design soil allowable bearing capacity as per
detailed drawing NO 1

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/4


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

FRAME

Concrete Works

Vibrated Reinforced Concrete (Grade C30/37,


With Minimum Cement Content 300 Kg/M3 And
Maximum Free Water Cement Ratio 0.55 As
Specified) As Described In

A Column M3 6

B Roof beam M3 9

High Tensile Deformed Bar Reinforcement


As Described

Note:-

Refer to note as described elsewhere in this Bill.

In Column

C 10 mm Diameter bar as link Kg 34

D 20 mm Diameter bar Kg 900

In Roof Beam

E 10 mm Diameter bar as link Kg 460

F 16 mm Diameter bar as link Kg 550

G 20 mm Diameter bar as link Kg 700

Sawn Formwork As Described To

H Sides of column M2 68

J Sides and soffit of roof beam M2 83

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/5


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

ROOF

Concrete Works

Vibrated Reinforced Concrete (Grade C30/37,


With Minimum Cement Content 300 Kg/M3 And
Maximum Free Water Cement Ratio 0.55 As
Specified) As Described In

A Roof slab 150 mm - 300 mm thick M3 24

Fabric Mesh Reinforcement As Described


(Meaasured Nett, Rate To Include For
250 mm Minimum Laps And Intersections)

B BMC A8 laid in roof slab M2 37

C BMC A10 laid in roof slab M2 10

Sawn Formwork As Described To

D Soffit of roof slab M2 160

E Edge of concrete not exceeding 250 mm high M 60

Cement And Sand (1:3) Paving As Described


And Finished With Steel Trowel

F 150 mm Thick to roof slab, laid to fall M2 160

Waterproofing System

Prepare And Apply Approved Polyurethane


Liquid Applied Waterproofing Membrane System
With 10 Years Warranty From The Date Of
Certificate Of Practical Completion Including
Forming All Necessary Angle Fillet And Upturn,
All In Accordance To The Manufacturer's
Instruction And Specification And To The
Satisfaction Of The S.O. As Described To

G Surfaces of roof slab M2 160


__________________

H Allow for carrying out Ponding Test to all roof


waterproofing system including all necessary
preparation, equipment and to the satisfaction
of the S.O. ITEM --- ---

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/6


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Prefabricated Cold Formed Steel Roof


Trusses System And Associated Roof
Structure

Notes:-

i) The contrator shall design, fabricate and


deliver to site and furnish at his expense all
necessary materials, tools, hoist, staging,
temporary bracing etc. for the safe and
proper erection of the prefabricated roof
trusses (PRT) complete with rafters, top and
bottom chords, bracings and tie-down,
struts, bearers, truss connectors, straps,
wall plates, connections, other associated
ancillary fixing products and methods and
obvious item required for the works to
ensure all items act together as an integral
structure that is structurally stable under all
the specified combinations of loading
conditions, all to the approval of the SO

ii) The design of the PRT roof trusses shall be


by AN APPROVED SYSTEM PROVIDER
(S.P) BY JKR and fabricated by a fabricator
as defined and in accordance with either
JKR-20601-0186-11-SPECIFICATION
PREFABRICATED COLD FORMED STEEL
ROOF TRUSSES or JKR-20601-0190-12-
SPECIFICATION PREFABRICATED
TIMBER ROOF TRUSSES and Architect's
drawings. The list of the approved S.P is
specified in the Appendix of the
specification.

iii) The Contractor shall note the PRT roof


trusses shall be designed to suit the
ceiling, roof coverings, mechanical &
electrical (M&E) services and whatever load
deem necessary to provide the functional
purpose of the building.

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/7


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Prefabricated Cold Formed Steel Roof


Trusses System And Associated Roof
Structure (Cont'd)

Notes:- (Cont'd)

iv) The water tank will need to be supported


separately In the case where PRT roof
trusses are designed at centres which do
not suit or facilitate the fixing of the ceiling ,
the Contractor shall include in his design of
the PRT roof trusses for any additional
bearers, tie-beams, ceiling joist, etc.
required to facilitate the ceiling panels. The
contractor shall also in his design, facilitate
the fixing of timber rafters and its
components used as an architectural
feature along the eaves of the PRT roof
trusses.

v) The Contractor shall ensure that all truss


member located on the ducting brackets
shall be protected with rubber pad to reduce
the vibration caused by ducting. Rod to
support ducting shall be installed on web
plane member (stronger axis to decrease
twisting on truss member). Drilling is strictly
prohibited on all truss member. M&E
services shall be installed using strap.

vi) The Contractor shall note that he shall be


solely responsible for the adequacy and the
sufficiency of the PRT roof trusses.

Rates to incude

Rates for the PRT roof trusses and rafters shall


include for all necessary materials, fabricating,
delivery to site, hoisting and fixing in position, all
fixing accessories including holding down bolt or
ram setting, all ancillary item and temporary
works for the complete installation of the PRT
roof trusses.

Rates for the PRT roof trusses shall also include


for design fees, testing for compliance, quality
assurance and control and all other necessary
cost for paten right design, trademark or name.

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/8


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Prefabricated Cold Formed Steel Roof


Trusses System And Associated Roof
Structure (Cont'd)

Note:-

Tenderers are requested to take note of the full


requirements of the "Prefabricated Cold Formed
Steel Roof Trusses System" Specification
including all works shown in the Tender
Drawings before pricing this Section.

Rates and prices entered here shall include


design, fabricate, transport, hoisting, install and
guarantee the whole of the Works as described
in detail in the "Prefabricated Cold Formed Steel
Roof Trusses System" Specification.

A Provide design, structural calculations, shop


drawings, etc. with PE endorsement as
stipulated in the Specification ITEM --- ---

Design, Supply, Fabricated And Deliver To Site


Cold Formed Steel Roof Trusses/Timber Roof
Trusses Including Fixing And Hoisting Position
All Fabricated PRT, Rafters, Chords, Bearers,
Tie-Down And Bracings, Struts, Wall Plate
Connectors And Fixings, Straps Other
Associated Ancillary Fixing Products And Other
Associated Works, Materials And Labour
Required For The Complete Installation Of The
PRT Roof Trusses To The Approval Of The S.O.

B Roof, fall at 25º pitch M2 287

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/9


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Roof Covering

"Asteel EnvioClean Ashin" Metal Shingles


Roofing Or Equal And Approved 0.48 mm
Total Coated Thickness (TCT) Concealed Fix
Metal Roofing Sheet Including All
Necessary Fixing Components And
Accessories, All Straight, Skew And Circular
Cutting At Eaves, Verges, Top Edges, Hips
And Valley, Etc. To Suit Roof Profile, All To
The Manufacturer's Instruction And
Architect's Approval (Measured Nett, Rate
To Include For Laps, Cutting And Wastages)

A Roofing sheet fixed to fall at 25º pitch on steel


framing (measured separately) M2 287

B Standard ridge capping including notching edges


to fit profile of roofing sheet, all constructed with
and including all necessary accessories M 16

C Standard hip capping including notching edges


to fit profile of roofing sheet, all constructed with
and including all necessary accessories M 26

Insulation Blanket As Described

D Approved 50 mm Thick (80 Kg/M3) rockwool


insulation blanket laid on aluminium foil
(measured separately) M2 287 30.00

Aluminium Foil As Described

E Approved double sided air sisalation aluminium


foil, laid and lapped 150 mm at joints and sealed
with and including approved adhesive jointing
tape or similar approved materials (measured
nett, rate to include for laps, adhesive tape, etc.) M2 287

Wire Mesh As Described

F 50 mm x 50 mm Chicken wire mesh of


approved gauge lapped 150 mm at joints and
secured to roof framing (measured nett, rate to
include for laps, etc.) M2 287

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/10


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Waterproof Plywood As Described

A Approved 12 mm thick waterproof plywood as


roof underlay for metal roofing fixed to steel
structure (measured separately) with and
including all necessary fixing accessories M2 287 50.00

Roof And Fascia Framing

"0.48 mm Thick Total Coated Thickness (TCT)


Asteel EnvioClean Metal Flashing" Or Equal
And Approved Clean Colorbond Steel Sheet
Flashing As Described

B Gutter flashing, bent to required shape to a total


girth of 305 mm with one end slotted between
roof covering and the other end dressed
over metal gutter as shown in detailed Drawing M 18 66.00

"0.48 mm Thick Total Coated Thickness (TCT)


Asteel EnvioClean Metal Fascia" Or Equal And
Approved Clean Colorbond Steel Sheet Fascia
As Described

C Barge capping, bent to required shape to a total


girth of 457 mm with one end dressed over roof
covering and the other end dressed over fascia
as shown in detailed Drawing M 18 66.00

D Barge capping, bent to required shape to a total


girth of 800 mm with one end dressed over roof
covering and the other end dressed over fascia
as shown in detailed Drawing M 48 66.00

E Metal fascia including all necessary fixing


accessories as shown in detailed Drawing M 18 66.00

F Metal eave fascia including all necessary fixing


accessories as shown in detailed Drawing M 48 66.00

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/11


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

ROOF (CONT'D)

Rainwater Goods

"0.48 mm Thick Asteel EnvioClean TCT Metal


Gutter" Or Equal And Approved Clean Colorbond
Steel Sheet Gutter As Described

A Gutter, bent to required shape to a total girth of


610 mm fixed to roof framing complete with
gutter support with and including all necessary
fittings and fixing accessories as shown in
detailed Drawing M 18

B Extra over gutter for forming stop end NO 4

C Extra over gutter for forming bend NO 4

D Extra over gutter for forming outlet to suit


100 mm diameter rainwater downpipe NO 4

Unplasticised Polyvinyl Chloride (U.P.V.C.)


Pipes And Fittings To B.S. 4514 Including
Jointing With Solvent Cement And Seal Ring
All As Described

Note:-

Rates for Unplasticised Polyvinyl Chloride


(U.P.V.C.) pipes shall include for expansion and
contraction joints as described.

E 150 mm Diameter rainwater downpipe M 5

F 150 mm Diameter rainwater downpipe laid in


trench including all necessary excavation and
backfilling M 1

G Fittings to downpipes, 150 mm diameter


rainwater downpipe for bend NO 3

H Fittings to downpipes, 150 mm diameter


rainwater downpipe for shoe NO 1

J Fittings to downpipes, 150 mm Diameter dome


shaped grating with mesh netting NO 1

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/12


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

EXTERNAL WALLS

Concrete Works

Vibrated Reinforced Concrete (Grade C20, With


Minimum Cement Content 300 Kg/M3 And
Maximum Free Water Cement Ratio 0.55 As
Specified) As Described In

A Window coping M3 1

Vibrated Reinforced Concrete (Grade C30/37,


With Minimum Cement Content 300 Kg/M3 And
Maximum Free Water Cement Ratio 0.55 As
Specified) As Described In

B Coping M3 9

High Tensile Deformed Bar Reinforcement


As Described

Note:-

Refer to note as described elsewhere in this Bill.

In Window Coping

C 12 mm Diameter bar Kg 42

In Coping

D 12 mm Diameter bar Kg 1,285

Sawn Formwork As Described To

E Sides and soffit of window coping M2 6

F Sides and soffit of coping M2 97

Industrialised Building System As Described

"Asteel Ajiya AGiBS" Or Equal And Approved


Wet Wall System With C&U Sections Galuzinc
Coated Steel, 0.44 mm Thick Zinc Coated Steel
Mesh With Grade 15 Mortar Infill All As Per
Drawings And Constructed In Accordance To
The Manufacturer's Instruction And
Specifications

G 212 mm Thick wet wall system M2 166

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/13


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

INTERNAL WALLS AND PARTITIONS

Industrialised Building System As Described

"Asteel Ajiya AGIBS" Or Equal And Aprroved


Wet Wall System With C&U Sections Galuzinc
Coated Steel, 0.44 mm Thick Zinc Coated Steel
Mesh With Grade 15 Mortar Infill All As Per
Drawings And Constructed In Accordance To
The Manufacturer's Instruction And
Specifications

A 212 mm Thick wet wall system M2 332

DOORS

Notes:-

All sawn timber are to be treated with two coats


of approved wood preservative and rates for sawn
timber are to include for above.

All timber frames abutting concrete or brickwork


shall be primed before fixing and assembling.
Rates for all door frames are to include for
priming frames with one coat of approved wood
primer sealer.

Rates for all timber door frames are to include


for mild steel holdfast as described.

Rates for all door frames shall include for filling


voids of approved materials in between framing
and brickwall or concrete wall as deemed
necessary by the S.O.

All fire-rated doors and door frames must be


constructed to the requirement and approval of
BOMBA and rate for fire-rated doors and door
frames shall include for above.

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/14


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

DOORS (CONT'D)

EXTERNAL AND INTERNAL DOORS

Doors And Door Frames

Acoustic Panel Door

A Pair of 40 mm thick acoustic panel door, overall


size 2400 mm x 2400 mm high in two equal
leaves, including hung door on hinges
(measured separately), all as per detailed
Drawings
(Type AD) NO 1

Fire-Rated Hardwood Door

B Approved one-hour fire-rated hardwood door,


overall size 800 mm x 2400 mm high complete
with approved aluminium door frame, including
hung door on hinges (measured separately), all
constructed as per detailed drawings and to the
BOMBA's and Manufacturer's specifications
(Type FD1) NO 2

Roller Shutter

C Approved anodised aluminium roller shutter,


overall size 2700 mm x 3100 mm high complete
with all necessary fittings and fixing
accessories, all as per Manufacturer's
instructions and specification
(Type RS1) NO 2

D Approved anodised aluminium roller shutter,


overall size 1800 mm x 3100 mm high complete
with all necessary fittings and fixing
accessories, all as per Manufacturer's
instructions and specification
(Type RS2) NO 1

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/15


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

DOORS (CONT'D)

EXTERNAL AND INTERNAL DOORS


(CONT'D)

Doors And Door Frames (Cont'd)

Approved Electro Galvanised Steel Door Frame,


Profile Size 130 mm x 40 mm Including All
Necessary Cutting, Shop And Site Welding,
Riveting, Bending, Filing Smooth Junctions,
Drilling Hole, Grouting Up Hollow Section Frame
With Cement And Sand (1:3) Mortar, Brick Ties,
Anchor Bolt Of Approved Type And Size, All
Other Necessary Fitting And Fixing Accessories
And Installed In Position All In Accordance With
The Manufacturer's Specifications

A Door frame for 2400 mm x 2400 mm high


opening
(Type AD) NO 1

Painting As Described

Prepare, Knot, Stop, Sand Smooth And Apply


One Coat Of Approved Wood Primer, One Coat
Of Approved Undercoat And Two Finishing
Coats Of Approved Gloss Enamel Paint On The
Following Timber Surfaces

B Surfaces of acoustic panel door M2 12

C Surfaces of fire-rated hardwood door M2 8

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/16


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

DOORS (CONT'D)

IRONMONGERY

Notes:-

Rates for ironmongery are to include for the


followings:-

a) The required matching screws and other


accessories

b) The identification of each key and lock

c) The supply and submission of extra keys for


locksets as required by the S.O.

Ironmongery Of The Following Or Equal


And Approved Brand To External And
Internal Doors And Frames And Including
Requisite Matching Screws And All
Accessories

A KASA 127 x 89 x 3 mm Fully 304 SS Hinges NO 8

B KASA 64T/74-8000/G2-HL-07-SO20 SS Mortise


Lockset NO 2

C KASA DCF-3770-1 Door Closer NO 1

D KASA DCF-3770-2/PA Door Closer NO 1

E Allow for the provision of approved master-keying


system for locks including submitting
Manufacturer's Certificate and master-keying
chart for the S.O.'s approval NO 2

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/17


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

WINDOWS

Notes:-

Rates for all window frames shall include for


filling voids of approved materials in between
framing and brickwall or concrete all as deemed
necessary by the S.O.

Sundry labour items like drip groove, throating,


rounded coves and external angles, V-grooves
and arises are not measured separately and
rates for plastering are to include for these
sundry labour items.

Approved Bronze Anodised Finish


Aluminium Windows Complete With Frame,
All Necessary Gaskets, Weatherstrips,
Sealers, Brackets, Straps, Tapping Screws,
Mastic, Hardwood Packing And Setting
Blocks, Approved Waterproof Silicone
Sealant Compound Pointing To Aluminium
Base And Side Sections, Fittings, Etc. And
Approved Ironmongery All Constructed As
Per Detailed Drawings And To The
Satisfaction Of The S.O.

Aluminium Framed Adjustable Glass Louvres


Cum Fixed Glass Louvres Window
(Glazing Measured Separately)

A Aluminium framed adjustable glass louvres


cum fixed glass louvres window, overall size
3000 mm x 600 mm high in five equal panels,
all constructed as per detailed drawings
(Type W1) NO 4

Glazing As Described

6 mm Thick Approved Clear Glass Louvered


Blade With Grounded And Polished Edges And
Fixed To The Aluminium Louvre Slot Framing
(Measured Separately)

B 150 mm Wide with both ends fixed into slot of


framing
(In 100 No.) M 60

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/18


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

FLOOR FINISHES

Note:-

All circular, raking and tapering cutting as


deemed necessary to all types of tiles laying
around pipes, floor grating, sanitary fittings and
junctions with floors and walls, etc. are not
measured separately. Rates for tiling are to
include for above cutting and waste.

25 mm Thick Cement And Sand (1:3) Paving


As Described And Finished With Steel
Trowel To

A Floor M2 158

B Apron slab, laid to fall M2 54

C Ramp slab including forming 10 mm x 10 mm


herringbone groove line at 300 mm gap apart M2 15

D Drop in floor, 100 mm high M 85

Waterproofing System

Prepare And Apply "SIKA" Or Equal And


Approved Cementitious Waterproofing Slurry
And Protective Coating System With 10 Years
Warranty From The Date Of Certificate Of
Practical Completion Including Forming All
Necessary Angle Fillet And Inclusive Of 150 mm
High Upturn At Wall, All In Accordance To The
Manufacturer's Instruction And Specification And
To The Satisfaction Of The S.O. As Described
To

E Floor M2 158

Prepare And Apply "Sika" Or Equal And


Approved Polyurethane Waterproofing
Membrane System With 10 Years Warranty
From The Date Of Certificate Of Practical
Completion Including Forming All Necessary
Angle Fillet And Inclusive Of 150 mm High
Upturn At Wall, All In Accordance To The
Manufacturer's Instruction And Specification And
To The Satisfaction Of The S.O. As Described
To

F Apron slab M2 54

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/19


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

FLOOR FINISHES (CONT'D)

Ponding Test As Described

A Allow for carrying out Ponding Test to all


waterproofing system including all necessary
preparation, equipment and to the satisfaction
of the S.O. ITEM --- ---

WALL FINISHES

Notes:-

All circular, raking and tapering cutting as


deemed necessary to all types of tiles laying
around pipes, sanitary fittings, light fittings and
junctions with floors and walls, etc. are not
measured separately. Rates for tiling are to
include for above cutting and waste.

Sundry labour items like drip groove, throating,


rounded coves and external angles, V-grooves
and arises are not measured separately and
rates for plastering are to include for these
sundry labour items.

12 mm Thick External Plastering In Two


Coats As Described To

B Sides of interlocking load bearing wall M2 166

C Sides of roof beam M2 35

12 mm Thick Internal Plastering In Two


Coats As Described To

D Sides of interlocking load bearing wall M2 332

Painting As Described

Prepare, Seal And Apply One Coat Of Approved


Alkali Resisting Primer And Two Finishing Coats
Of Approved Acrylic Paint On The Following
External Surfaces

E Plastered sides of wet wall system M2 166

F Plastered sides of roof beam M2 35

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/20


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

WALL FINISHES (CONTD)

Painting As Described

Prepare, Seal And Apply One Coat Of Approved


Alkali Resisting Primer And Two Finishing Coats
Of Approved Emulsion Paint On The Following
Internal Surfaces

A Plastered sides of wet wall system M2 332

CEILING FINISHES

Notes:-

Rates shall include for forming openings for light


fittings, air-conditioner grilles, etc. and shall
further include for all types of cutting to the
required length and sizes, trimming around
openings, columns, etc. and waste. Rates shall
also include for additional timber framing and
framing for suspension system to the above. The
Contractor shall submit shop drawings for
approval.

Rates shall also include for ramset anchors or


bolting or other fixing accessories to soffit of
concrete slab.

Rates shall include for replacing soiled or spoilt


boards and for touching up.

The Contractor shall coordinate the orientation of


suspended ceiling with the lighting layout.

Rates for suspension system shall include for all


pins, hangers, runners, cover angles, wall
angles, corner beads, angle beads and all other
accessories.

Rates for ceiling board shall include for


accessories to prevent sagging of board such as
diagonal bracing of board, etc.

All sawn timber are to be treated with two coats


of approved wood preservative and rate for sawn
timber are to include for above.

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/21


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

CEILING FINISHES (CONT'D)

Notes:- (Cont'd)

Sundry labour items like drip groove, throating,


rounded coves and external angles, V-grooves
and arises are not measured separately and
rates for plastering are to include for these
sundry labour items.

Cement Board Ceiling As Described

A 1200 mm x 1200 mm x 3.2 mm Thick class 'O'


cement board ceiling lining fixed to 50 mm x
50 mm hardwood nogging at 600 mm centres,
50 mm x 50 mm hardwood joists at 1200 mm
centres with and including 25 mm x 12 mm
hardwood beading at all joints, all to the approval
of the S.O. M2 153

B 1200 mm x 1200 mm x 3.2 mm Thick class 'O'


cement board ceiling lining to roof eave ditto M2 33

C Extra over for forming 750 mm x 750 mm


removable access opening including all
necessary timber framing NO 1

Ceiling Insulation

Insulation Blanket

D Approved 50 mm Thick (80kg/m3) rockwool


insulation blanket laid on chicken wire mesh
(measured separately) M2 36

Wire Mesh As Described

E 50 mm x 50 mm Chicken wire mesh of


approved gauge lapped 150 mm at joints and
secured to ceiling (measured nett, rate to
include for laps, etc.) M2 36

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/22


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

CEILING FINISHES (CONT'D)

Painting As Described

Prepare, Seal And Apply One Coat Of Approved


Alkali Resisting Primer And Two Finishing Coats
Of Approved Acrylic Paint On The Following
External Surfaces

A Surfaces of cement board ceiling to roof eave


(measured flat overall) M2 33

Prepare, Seal And Apply One Coat Of Approved


Alkali Resisting Primer And Two Finishing Coats
Of Approved Emulsion Paint On The Following
Internal Surfaces

B Surfaces of cement board ceiling (measured flat


overall) M2 153

INTERNAL COLD WATER SERVICES


(ALL PROVISIONAL)

Notes:-

All short lengths, sockets, connectors,


backnuts, elbows, bends, firenuts, tees,
diminishing pieces, reducers and plugs and
the like of all piping work are not measured
separately.

Rates for piping work are to include for the


above.

All water supply pipes are to be chased into the


wall and rate to also include for chasing pipe into
the wall top conceal the piping and make good,
unless the piping runs through ducts as
indicated on the drawings.

Rates for piping work shall also include for


forming holes through slabs and walls including
all approved pipe sleeve and mastic compound
as required, working in confined spaces and
testing of pipes and fittings to conform to
requirements as directed by Architect/Engineer.

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/23


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Item Description Unit Qty. Rate Amount (RM)

INTERNAL COLD WATER SERVICES


(ALL PROVISIONAL) (CONT'D)

Complete Supply, Delivery, Installation And


Connection Of Above Ground Cold Water
Pipings Including Elbows, Bends, Tees, Ends,
Pipe Sleeves And All Other Necessary Fittings,
And Finshing Works As Specified And As
Shown On Drawings

A 25 mm Diameter Polyproplylene Random


Copolymer (P.P.R) pipe M 8

B 20 mm Diameter stop valve NO 1

INTERNAL SANITARY PLUMBING


(ALL PROVISIONAL)

Notes:-

When pipes are to be chased into the wall, the


Contractor shall include in his rate for chasing
pipe into the wall to conceal the piping and
make good, unless the piping runs through
ducts as indicated on the drawings.

Rate for piping work shall also include for


forming holes through slabs and walls including
all approved pipe sleeve and mastic compound
as required and working in confined spaces.

Complete Supply, Delivery, Installation And


Connection Of Soil, Waste And Vent Pipings
Laid Underground Floor Slab And Apron Slab
Inclusive Of Fittings, Pipe Sleeves, Necessary
Excavation And Connection To Sewage
Manholes, Drain, Sump And All Other
Necessary Accessories As Specified And As
Shown On Drawings:-

C 50 mm Diameter Unplasticised Polyvinyl


Chloride (U.P.V.C.) pipe M 5

D 100 mm Diameter floor trap NO 1

C/C… RM

kubs-Bill 8 -Ancillary Buildings 8/2/24


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Amount (RM)

COLLECTION

From Page No. ….. 8/2/1 -

From Page No. ….. 8/2/2 -

From Page No. ….. 8/2/3 -

From Page No. ….. 8/2/4 -

From Page No. ….. 8/2/5 -

From Page No. ….. 8/2/6 -

From Page No. ….. 8/2/7 -

From Page No. ….. 8/2/8 -

From Page No. ….. 8/2/9 -

From Page No. ….. 8/2/10 -

From Page No. ….. 8/2/11 -

From Page No. ….. 8/2/12 -

From Page No. ….. 8/2/13 -

From Page No. ….. 8/2/14 -

From Page No. ….. 8/2/15 -

Carried Forward … RM -

kubs-Bill 8 -Ancillary Buildings 8/2/25


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK ANCILLARY BUILDINGS

Section 2 - Electrical Building

Amount (RM)

COLLECTION Brought Forward … -

From Page No. ….. 8/2/16 -

From Page No. ….. 8/2/17 -

From Page No. ….. 8/2/18 -

From Page No. ….. 8/2/19 -

From Page No. ….. 8/2/20 -

From Page No. ….. 8/2/21 -

From Page No. ….. 8/2/22 -

From Page No. ….. 8/2/23 -

From Page No. ….. 8/2/24 -

Section 2 - Electrical Building


Total Carried To Summary RM -

kubs-Bill 8 -Ancillary Buildings 8/2/26


PEMBINAAN FASA KEDUA INSTITUT KEMAHIRAN ISLAM SARAWAK

BILL NO. 8

ANCILLARY BUILDINGS

SUMMARY

Amount
From Page No. Section
(RM)

8/1/20 No. 1 - Pump House

8/2/26 No. 2 - Electrical Building

Bill No. 8 - Ancillary Buildings


Total Carried To Final Summary Of Tender RM
On Page FST/1

kubs-Bill 8 -Ancillary Buildings 8/S/1