“PYROPROTECT”

NON-PERCOLATING FLEXIBLE FIRE


FIGHTING DELIVERY HOSE

TECHNICAL DATA

Manufacturer NewAge Fire Fighting Co. Ltd.

Approval BIS Approved

1. IS 636 : 2018 For Fire Hose


Reference Standard
2. IS 903 : 1993 For Coupling

Type of Hose Type 3 (Covered)

Internal Diameter 63 mm

Length 15 meter

Mass Max. 620 g/m

Coil Diameter Max 55 cm (For 30 Meter


length hose without coupling)

Hydrostatic Proof Pressure 23 kgf/cm2


GENERAL DESCRIPTION
Hydrostatic Burst Pressure Min. 38 kgf/cm2
NewAge make Pyroprotect Hose is the best quality
maintenance-free rubber covered fire hose. Specially Kink Test 23 kgf/cm2
formulated blend of Nitrile/PVC rubber compound is
Pressure Loss Max. 0.50 Bar
extruded throught a circular reinforcement made of
100%polyester and polyamide high tenacity yarn. This Each Hose shall be clearly
“through-the-weawe” extrusion process gives an and permanently marked
excellent rubber to textile adhesion to increase the Ÿ Type of hose
Ÿ Size of the hose
durability of the hose, very smooth inner surface for low Marking Ÿ Length of the hose
friction loss and Ribbed external cover for high abrasion Ÿ Manufacturer’s Name or
resistance and ease of handling. Trade-mark or Both
Ÿ Month and Year of
ADVANTAGES Manufacture
Ÿ IS Mark

Ÿ Light weight lay flat hose


Ÿ Minimum friction loss
End Connection
Ÿ Ribs on external side for high abrasion resistance and
Instantaneous pair of male &
ease of handling Type of Coupling
female parts
Ÿ High resistance to oil and chemicals, acid and
alkalies, fuel, etc. Ÿ SS 304 (IS 3444 Gr. 1)
Material of Construction
Ÿ Excellent resistance to ozone and UV Ÿ Gunmetal (IS 318 LTB 2)
Ÿ Very high resistance to weather and ageing Ÿ Aluminum Alloy
Ÿ Cold resistance up to -40 ᵒC
Ÿ Heat resistance up to + 100 oC Size 63 mm X 63 mm
Ÿ Very easy to maintain
Binding Wire SS Wire

Page 1 of 2 Rev.0 DS-FDH-003


Internal Maximum Hydostatic Minimum Maximum
Diameter Weight Proof Pressure Hydrostatic Pressure loss/23m
(mm) (g/m) (Kgf/cm²) Burst Pressure (bar)
(Kgf/cm²)

38 380 23 38 0.75

50 490 23 38 0.40

63 620 23 38 0.50

70 680 23 38 0.40

Application AVAILABLE COLOURS

Ÿ Fire Brigades
Ÿ Industries
Ÿ Refineries
Ÿ Chemical & Petrochemical Complexes
Ÿ Defense, Airforce & Navy
Ÿ Power Plants
Ÿ Domestic & International Airports

HOSE CARE & MAINTENANCE

Ÿ Hose Should be stored in cool, dry, clean and well ventilated storage area.

Ÿ Once the hose is used, it must be dried completely. It must also be checked for any cuts on the external surface.

Ÿ In case the hose has got in contact with oil or chemical, it must be washed thoroughly with detergent soap and them
dried completely before storing.

Ÿ Hose must be tested at a pressure of 50% in excess of the intended working pressure or at 10.5kg/cm2, whichever is
greater. The test must be conducted at least once in six months. Hose with small leaks should be repaired, wherever
possible. Hose with excessive leaks should be removedfrom service.

Ÿ While in use, avoid dragging hose over sharp objects or abrasive surfaces.

Ÿ Avoid hose kinks as much as possible.

Ÿ During operation, all necessary precautions must be taken to make sure that the hose does not get in direct contact
with hot surface or flame.

Ÿ While in operation, hose ramps should be used to avoid vehicles running over the hose.

Ÿ Hose should be coiled loosely enough to avoid any cracking on the edge of the hose.

NOTICE
* Inline with NEWAGE policy for continuous development, NEWAGE reserves the right to change specifications without prior notice
* All picture shown are for illustration purpose only. Actual product may very in appearance

Ambawadi Industrial Estate, Surendranagar - 363001 Gujarat, India


Phone: +91 2752 288000 I Fax: +91 11 6617 3355 I info@newage-india.in I www.newage-india.in

Page 2 of 2 Rev.0 DS-FDH-003