Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Velosi Certification LLC

Abu Dhabi Business Hub,


ICAD -1, Mussafah
P.O Box 114182, Abu Dhabi, UAE
Tel No.: +971 2 550 2600
Fax No.: +971 2 550 2601

ULTRASONIC EXAMINATION REPORT


Client : ETIHAD RAIL DB

Project : ETIHAD RAIL Date: 22-11-2017

Location : AL MIRFA Report No. VEL/UT/2017-031

Drawing No: N/A Procedure No : L4-UAE-048L (Rev 4) Applicable Code: ASME SEC-V

Job No: 1590 Acceptance Criteria: SA 609

Stage of Test: FINAL Material: CS Material Thickness: Various


Reference Block: KNUCKLES FLAT
Calibration Block: V1 & V2 Welding Process: N/A
BOTTOM HOLE
Equipment: USM 35 X Equipment Sr.No: 12913 a Surface Condition: SMOOTH

Calibration Date : 13-03-2017 Calibration Due Date : 12-03-2018

Inspection Technique: PULSE ECHO – CONTACT METHOD Heat Treatment: N/A

Cable Type : LEMO TO MINI LEMO Cable Length : 2 METER

Reject Control: LOW Damping: LOW Couplant: CELLULOSE


Probe Transfer Gain
Probe Probe Frequency Reference Scanning Range (in
Size Correction (PRL)
Type Angle in MHz Reflector dB mm)
(in mm) dB dB
TR Ø10 0° 2MHz 6.4mm Dia FBH - 49 +6 0-150

ANGLE 8X9 70° 2MHz 1.5mm Dia SDH - 52 +6 0- 300

ANGLE 8X9 45° 2MHz 1.5mm Dia SDH - 50 +6 0- 250

S.N. Description No.Of Knuckels Welder Id Weld Type Observation Result

Knuckles
ID: 043-B
1. ID: 180-B 04 Nos N/A N/A NRI Acceptable
ID: 214-A
ID: 102-A

REMARKS: - UT was carried out on the above mentioned items to check the sub-surface discontinuity.

OBSERVATION: NO relevant indication observed, accepted as per specification.


LEGEND: NRI- No Recordable Indication, ACC- Acceptable, NAC- Not Acceptable, N/A- Not Applicable

Level II NDT Inspector Reviewed by Level III

Name: PANKAJ SHARMA Name: Vikas Chandra


Signature:
Signature:

Date: 22-11-2017 Date:23-11-2017

L5-UAE-043 Rev No. 2 Rev Date 06-01-2017 Page 1 of 2


Velosi Certification LLC
Abu Dhabi Business Hub,
ICAD -1, Mussafah
P.O Box 114182, Abu Dhabi, UAE
Tel No.: +971 2 550 2600
Fax No.: +971 2 550 2601

ULTRASONIC EXAMINATION REPORT


Client : ETIHAD RAIL DB

Project : ETIHAD RAIL Date: 22-11-2017

Location : AL MIRFA Report No. VEL/UT/2017-031

Drawing No: N/A Procedure No : L4-UAE-048L (Rev 4) Applicable Code: ASME SEC-V

Job No: 1590 Acceptance Criteria: SA 609

Stage of Test: FINAL Material: CS Material Thickness: Various


Reference Block: KNUCKLES FLAT
Calibration Block: V1 & V2 Welding Process: N/A
BOTTOM HOLE
Equipment: USM 35 X Equipment Sr.No: 12913 a Surface Condition: SMOOTH

Calibration Date : 13-03-2017 Calibration Due Date : 12-03-2018

Inspection Technique: PULSE ECHO – CONTACT METHOD Heat Treatment: N/A

Cable Type : LEMO TO MINI LEMO Cable Length : 2 METER

Reject Control: LOW Damping: LOW Couplant: CELLULOSE


Probe Transfer Gain
Probe Probe Frequency Reference Scanning Range (in
Size Correction (PRL)
Type Angle in MHz Reflector dB mm)
(in mm) dB dB
TR Ø10 0° 2MHz 6.4mm Dia FBH - 49 +6 0-150

ANGLE 8X9 70° 2MHz 1.5mm Dia SDH - 52 +6 0- 300

ANGLE 8X9 45° 2MHz 1.5mm Dia SDH - 50 +6 0- 250

S.N. Description No.Of Knuckels Welder Id Weld Type Observation Result

Knuckles
ID: 102-B
2. ID: 001 04 Nos N/A N/A NRI Acceptable
ID: 002
ID: 003

REMARKS: - UT was carried out on the above mentioned items to check the sub-surface discontinuity.

OBSERVATION: NO relevant indication observed, accepted as per specification.


LEGEND: NRI- No Recordable Indication, ACC- Acceptable, NAC- Not Acceptable, N/A- Not Applicable

Level II NDT Inspector Reviewed by Level III


Name: PANKAJ SHARMA
Name: Vikas Chandra
Signature:
Signature:

Date: 22-11-2017 Date: 23-11-2017

L5-UAE-043 Rev No. 2 Rev Date 06-01-2017 Page 2 of 2

You might also like