Trouble Shooting Directory of WAM-4 (6P), WAG-5, WAG-7 & WAP-4 Locomotives
Trouble Shooting Directory of WAM-4 (6P), WAG-5, WAG-7 & WAP-4 Locomotives
Directory of
Page 1 of 105
CONTENT
SL NO SUBJECT Page No
From To
1. Scope of the Manual 3 3
2. Standard instruction for loco pilot & Loco 3 5
controllers
3. Current rating of Traction Motors for Electric 5 5
locomotives
4. General information and trouble shooting of VCD & 5 7
C2N Feed Valve
5. Instructions about Auto Flasher light. 8 8
6. Different Pneumatic panel 9 12
Page 2 of 105
WAM-4(6P), WAG5, WAG7,& WAP-4 LOCOMOTIVES
This manual briefly describes the various steps to be taken by the Loco Pilots in case of
loco troubles on line.
The prescribed trouble shooting procedures laid emphasis on quick trouble shooting and
faster clearance of block sections in case of a mid-section failure.
This manual deals with the trouble shooting of locos as single, multiple and consists.
1. During trouble shooting in block section, utmost care should be taken to trouble
shoot the fault, and resume traction within 10 minutes. If unsuccessful
LC/TPC/CONTROL to be informed within next 10 minutes, for assistance. All
efforts should be made to minimize the detentions in block section.
2. In MU/Consist, if one of the loco fails, try to clear block section with good
loco/locos without wasting time for trouble shooting.
3. In case of trouble shooting in MU/Consist locos, the abnormal sign should always
be picked up from leading loco. There after all the observations and interventions
shall be made on the loco which is defective. [Always check the proper fitment of MU
jumpers].
4. When ever HOBA is placed in ‗Off‘ position during trouble shooting in one of the loco
in MU/Consist, HOBA of other locos also to be kept in ‗Off‘ position.
(b) While Q-118 manually operated, release it after all blowers start or after 1
minute.
(c) While operating GR manually, ensure GR on ‗O‘ by anticlockwise movement.
6. LC should be informed at the normal stoppage regarding wedging of
relays/contactors.
(a)FOR WEDGING CONTACTORS: i) Take Full Safety measures. If C105, C106
& C107 are wedged, Q118 is to be
manually operated for closing DJ in ARNO
base loco.
ii) After isolating any auxiliary motor through
rotating switch, ensure its corresponding
contactor is properly opened.
Page 3 of 105
b) FOR WEDGING RELAYS: First switch off battery.
i) If relay Q118 is wedged- block section
may be cleared observing working of all
auxiliaries.
ii) Wedging of Q118 is not Permitted in
trailing Loco/Locos while driving from
leading loco.
iii) During the course of trouble shooting, if
it is required to wedge Q118 on rear loco –
Proceed to rear loco and wedge Q118 on
rear loco. Clear block section only driving
from rear loco observing working of all
auxiliaries following G&SR in force.
iv) Wedging of relay Q-44 & Q-45 is strictly
prohibited.
7. (a) During trouble shooting if MPH is isolated, the train can be worked up to the
destination provided MVRH is working normally and there is no appreciable rise
in the oil level in the transformer gauge.
Page 4 of 105
11. Check availability/working of following safety equipments.
a. Flasher lights, Auto Flasher light, Marker lights, Head lights, Horns, Wipers,
Speedometer, Sanders and availability of dry sand in the sand boxes.
b. Portable telephone/Fire extinguishers/detonators/wooden wedges.
12. In case of ICDJ & TLTE, failed to rectify according to tripping and Traction failure,
drain out MR & RS pressure, close DJ/VCB and resume traction after rebuilding of
RS & MR pressure.
13. During the course of trouble shooting, if it is required to switch off HBA, IP C.O.C.
must be isolated before switching off HBA and it should be kept normal after
switching ON HBA.
14 IP C.O.C. must be kept isolated in trailing loco/locos in MU/ Consist and in dead
loco.
Page 5 of 105
INSTRUCTIONS TO BE FOLLOWED FOR VCD LOCOS
Vigilance Control Device (VCD) monitors alertness of the engine crew on continues
basis by checking his actions while running a train.
VCD consists of one control unit, two display unit (one on each cab), relay QVCD &
isolation switch HVCD.
On putting BL key on BL box (Unlock), the VCD will become active but will remain in
suppressed mode. When pressure in locomotive build up, the VCD will start
functioning.
1. Engine crew should do any of the following operation once in 60 seconds for non
actuation of VCD:
a) Notch up/Notch down by master controller or EEC;
b) Brake applications through A9
c) Application of sander;
d) Pressing VCD acknowledgement push button available for LP.
e) Pressing of foot switch available for LP;
f) Operation of first shunting notch i.e. MPS-1
2. Actuation of VCD:
a) If none of the above operations is done within 60 seconds, a yellow flashing light will glow
for 8 seconds.
b) Even after that no operation is done then an alarm will sound along with yellow flashing light
for another 8 seconds.
c) Even after that (total 76 sec) if no operation is not done then VCD will actuate & apply
penalty brake automatically for 32 seconds and auto regression will take place. During
brake application only yellow flashing light shall glow.
3. Resetting of VCD:
Wait for 32 sec after penalty brake application.
Keep MP on zero position and then push the Reset push button available at driver desk.
(Pressing of reset button before 32 second shall not reset the VCD).
Page 6 of 105
4. Bypass / Isolating of VCD:
If RED LIGHT (FAULTY) flashes on VCD cab unit it indicates VCD has become defective.
Put Bypass Switch HVCD on position ‗0‘ from ‗1‘ to bypass VCD duly endorsing in the log
book and inform TLC.
Ensure the glowing of Bypass lamp in VCD cab unit & displaying VCD bypass in VCD
main unit and resume traction.
Trouble shooting
1. In case of auto regression of GR on 1st notch - check relay QVCD-
If energized – Reset VCD as per procedure.
If unsuccessful- try with putting HBA on ‗0‘ and again on ‗1‘
If unsuccessful- wedge QVCD in de-energized condition and isolate VCD by keeping HVCD
on ‗0‘.
2. BP Pressure is not building up after resetting VCD
Check IP valve for any air leakage and found, Isolate IP valve C.O.C and Open after BP
is recreated.
If unsuccessful- Isolate IP valve C.O.C and isolate VCD by putting HVCD on‘ 0‘
Note: QTW-6 relay is provided in place of QVCD in some locos.
C2 N feed valve in place of D24B feed valve (feed pipe) with incoming isolating cock &
out going isolating cock is provided in some locos.
NB : Both the Incoming & out going isolating cocks shall be isolated in case metallic feed pipe
broken due to cattle run over and work with single pipe and Dead loco.
Page 7 of 105
Instruction About Auto Flasher Light :
Modification of switch ‗ON‘ Auto Flasher Light, LED & Audio indication automatically during
train parting/ACP is just an aid to Loco Pilot.
This modification does not alter duties/responsibility of the Loco Pilot as mentioned in GR&SR.
1. Press push button switch ―BPSW‖ provided in each cab for initial charging of BP after EOT
& for quick release of train brakes when applied A9.
BPSW is to be released after BP reaches 5 Kg/cm2.
2. The modification functions only when Reverser key ―MPJ‖ is operated in ―F‖ or ―R‖
direction.
3. To test this modification, press test switches ―TS‖ provided in Cab2 and observe Auto
Flasher Light working, Buzzer sounding, LED indication and auto regression of GR. It
works till it is kept in pressed condition.
4. In case of train parting/ partial uncoupling of BP pipe / during ACP / application RS1/RS2,
Loco Pilot gets Auto Flasher Light with buzzer & LED indication and auto regression of GR.
Loco Pilot should immediately find out the cause of abnormality and act as given in GR and
SR
5. Press reset switch SW to stop flasher light working & buzzer sounding after checking and
ensuring for any abnormality as per GR & SR, LED indication continues to glow till BP
recharges to 4.8 Kg/Cm2.
6. If resetting of only buzzer is required but wants to continue the glowing of flasher light then
LP must manually switch ‗ON‘ Flasher Light before pressing reset switch SW.
7. In any emergency, if auto Flasher Light is not working, put ‗ON‘ flasher light manually.
8. In MU operation during cab changing from one to another loco the following sequence of
operation should be carried out by the Loco Pilot to release the air pressure of P1 pipeline
between MU2B & A9 valve of trailing loco.
o MU2B to be operated to ―Trail‖ position & isolate the L/T cock.
o Apply A9 valve up to full service then isolate the inlet & outlet cut out cock so as to
release BP pressure.
Release A9 and proceed to other loco and energize as per normal
procedure.
In case of malfunctioning of Auto Flasher Light, or if TLTE is experienced, remove
CCLSA fuse and resume traction, work the train. Inform TLC, and
make an entry in the loco logbook.
9. Loco Pilot should not disturb setting of pressure switches/ A9 after the Sheds have set it.
10. Whenever a goods train is controlled by A-9 and while recreating BP, if it takes more than
1minute to come BP pressure up to 4.7 kg/cm2 due to excess leakage on train. This may
be cause for glowing of Auto flasher light. In this case LP is advised to release A9 gradually
/press SW as per condition.
NB :- NEVER USE TEST SWITCH “TS” WHILE TRAIN IS ON RUN
Page 8 of 105
Tri-plate Pneumatic Panel (Stone India)
Page 9 of 105
Tri-plate Pneumatic Panel (Faively)
STONE INDIA
Page 10 of 105
KNORR -BREMSE
FAIVELEY TRANSPORT
Page 11 of 105
TROUBLE SHOOTING DIRECTORY
1. CHAPTER ONE
Tripping Failure 15
2. CHAPTER TWO
Traction failure 38
3. CHAPTER THREE
Miscellaneous failures 49
4. CHAPTER FOUR
Page 12 of 105
CHAPTER – I
TRIPPING FAILURE
CHECKING OPERATION IN CASE OF TRIPPING FAILURE
Preparation-1
Tripping on line, Bring MP to ‗0‘, wait 15 second for LSGR to glow, If LSGR does not glow
then bring GR to 0 manually., If LSGR glow then check panto and OHE. If any abnormality
found then lower panto, stop the train, comply with GR 6.03, contact LC/TPC. If no
abnormality found on OHE & panto, then check relay targets by physically operating reset
button of each relay, If relay target show red/locked indication refer the page number as
follows.
2 QLA dropped 17
3 QOA dropped 17
Page 13 of 105
If no relay target dropped, to pick up abnormal sign do as
given below:-
Preparation-2
Ensure MP on ‗0‘, & LSGR glows and RS pressure in between 8-10 Kg/Cm². Open all top
row BL switches except BLCP ‗A‘, Close BLDJ, Press BLRDJ and observe LSDJ, UA
needle & LSCHBA to pick up the abnormal signs as follows:-
Page 15 of 105
Probable defects/
observation/checking Action to be taken by the Loco Pilot
2. IF QLA HAS DROPPED Check for smoke emission from auxiliary motors,
contactor panel, switch board, Q30,UA,ARNO,
R118 and C-118/S-118.
If no abnormality- Reset the relay target.
Close DJ. Resume traction.
If DJ trips again through QLA.
Check for smoke emission.
If no smoke emission- reset the relay target, close
DJ and resume traction.
If there is smoke emission, isolate the
corresponding equipment and work as per standard
instruction.
3. QOA DROPPED Check for smoke emission from Auxiliary motors,
contactor panel, switch board,Q30,UA, ARNO,
R118, C118/S-118, etc. Ensure all contactors are
open.
If no abnormality do the following.
A. I. If QOA target reset Reset the relay target. Close DJ and Resume
traction.
II. If DJ trips again OpenBLRA-1/BLRA-2,remove CCRA-1,CCRA-
through QOA 2,CCVT & CCSPM. Reset the relay target. Close
DJ and resume traction. Inform LC at the first
opportunity and enter in log book.
III. If DJ trips again Put HVSI-1 & 2, HVSL-1 & 2, HPH, HCHBA on ‗O‘
through QOA. and BLCP, and BLVMT ―OFF‖. Reset relay target.
Close DJ.
If DJ trips again through QOA, Put HQOA on
―O‖, Reset relay target. Close DJ – resume
traction.
Observe for any smoke emission on run and work
as per step ‗C‘.
If DJ holds, put back HVSI-1 & 2, HVSL-1&2,
HCHBA and HPH on position ‗I‘ one by one. If DJ
trips after putting any switch on position-1, isolate
that auxiliary and work the train as per standard
instruction.
Page 16 of 105
Probable defects/
observation/checking Action to be taken by the Loco Pilot
B. If DJ trips through QOA Put HOBA on ―OFF‖ position. Reset relay target.
with HQOA on ―O‖, Close DJ – resume traction.
Observe for any smoke emission on run.
Page 17 of 105
Probable defects/
observation/checking Action to be taken by the Loco Pilot
4.
QOP-1 OR QOP-2 ALONE ,Check for smoke emission from TMs, Reversers, CTFs,
HAS TRIPPED RSI block, line contactors, shunting contactors, SLs, etc.
If there is smoke emission- Use fire extinguisher to
extinguish fire.
Isolate the equipment- Resume traction.
If there is no smoke emission-
Reset the relay – Resume traction.
i. If DJ trips again through the
same relay.
Put the corresponding HMCS on position II, III, IV, one
by one. Reset the relay- Resume traction.
Observe QOP dropping.
Keep HMCS in that position, where QOP is not
dropping. Resume traction.
ii. If QOP-1/QOP-2 drops in all
positions of HMCS.
Put corresponding HQOP in ‗OFF‘ position.
Put back HMCS on position 1 – Resume traction.
Observe for any smoke emission on run.
If QOP-1/QOP-2 drops again –
Put HOBA in ‗OFF‘ position – Resume traction.
Observe for any smoke emission on run.
a. IF RELAY INDICATOR CANNOT BE RESET.
.i. Put HBA in ‗off‘ position. Reset relay target
and put HBA ‗ON‘.
ii. If target drops when put HBA ‗ON ‘try with isolating
TM‘s one after another.
Iii .If not success Put HQOP-1/HQOP-2 in ‗OFF‘ Reset
the relay target- Resume traction.
Observe for any smoke emission on run.
iv. If still unable to reset the relay:
Put HOBA in ―OFF‖ position.
Reset the relay target – Resume traction.
Observe for any smoke emission on run.
v. If still unsuccessful (after putting HOBA in OFF )
Isolate corresponding block. Resume Traction.
If unsuccessful, ask for relief Loco.
5. QRSI1/QRSI-2 ALONE HAS a. Reset the relay indicator.
TRIPPED Note down the Ammeter reading
Resume traction at lower notches (less TM current).
b. If unsuccessful:
Isolate any one Traction Motor corresponding to
QRSI dropped.
Resume traction.
c. If unsuccessful again
Isolate corresponding RSI (Rectifier) block.
Put HVSI-1/HVSI-2, HVSL1/HVSL-2 and HVMT-
1/HVMT-2 on ‗O‘.
If load permits – Resume traction and inform LC.
If unsuccess ask for relief loco.
CAUTION--DO NOT PUT HQOP/HOBA IN “OFF” POSITION UNLESS TRACTION
MOTOR-ISOLATION IS TRIED THROUGH OPERATION OF HMCS
Page 18 of 105
Page 19 of 105
ICDJ
LSDJ REMAINS GLOWING
REMARK - I
Probable defects/
observation/checking Action to be taken by the Loco Pilot
Ensure BLDJ is closed, LSGR glowing and ZPT is in other than ‗O‘ position.
1. IF LSGR EXTINGUISHED Bring GR to ―O‖ manually. Close DJ after
ensuring LSGR is glowing.
2. IF LSGR GLOWING a. Check C-118/S-118 for closing/not
closing by following the method given below.
b. Stand near C-118/S-118. Ask the Asst. Loco
Pilot to close BLDJ and press
BLRDJ./BP2DJ Listen to the closing sound
of C-118/S-118.
3. IF C-118/S-118 CLOSING If closing sound is heard-
Ensure RS pressure is above 8 kg/ cm².
IF RS PRESSURE IS LESS Ensure air control cut out is open, RDJ drain
THAN 8 KG/CM² cock closed.
Then build up RS pressure through CPA up to
8kg/cm².
IF RS PRESSURE IS Drain out full RS pressure and close DJ after re-
EXCESS building RS to 8 kg/ cm².
a. Check DJ / VCB for any air leakage.
b. VCB pressure regulating gauge is showing
more than 5.2 kg/ cm², if visible.
4. IF C-118/S-118 IS NOT Check BA Voltage.
CLOSING-
Page 21 of 105
Probable defects/ Action to be taken by the
observation/checking Loco Pilot
6. IF Q-45 ALONE NOT a. Check CCDJ-
ENERGISED
i)-If CCDJ found melted – - Renew the same. If melts again put HOBA
‗off‘ and renew the fuse. If CCDJ melts after
putting HOBA ‗off‘ request for assistance.
ii)- If CCDJ found good - Change the position of ZPT. Ensure GR on
‗O‘.
Operate GR manually from ‗O‘ to ‗1‘ and
back to ‗O‘ for few times.
Close BLDJ, press BLRDJ/BP2DJ - Close
DJ.
b. If still Q- 45 not energized –
Operate Q-45 manually, (after ensuring GR
on ‗O‘). Release Q45 after LSCHBA goes
out. Resume traction.
Every time for closing DJ, Operate Q45
manually.
c. If DJ does not close – Don‘t release Q45.
Check Q-44.
If Q-44 is energized -Try from other cab.
If DJ closed – Resume traction.
Clear the block section, observing the GR &
SR in force.
If unsuccessful – Request for assistance.
7. IF Q-44 ALONE NOT Operate GR manually from ‗O‘ to ‗1‘ and
ENERGISED back to ‗O‘ for few times.
Close DJ– Resume traction.
If unsuccessful – Close both Q-45 &Q-44
manually. Release Q-44 & Q-45 after
LSCHBA goes out.
Resume traction.
If unsuccessful – Request for assistance.
Page 22 of 105
REMARK – II
[FOR REAR LOCO IN MU / CONSIST]
ICDJ on trailing/rear loco in i. If the load permits – Clear the block section by
MU/Consist. leading loco.
IMPORTANT INSTRUCTIONS
a. WEDGING OF Q-118 NOT PERMITTED IN TRAILING LOCO.
If it is necessary to wedge Q -118 on rear loco, follow standard instructions .
b. WEDGING OF Q-118 ON LEADING LOCO IS PERMITTED TO CLEAR BLOCK
SECTION ONLY.
c. WEDGING OF Q-44 IS STRICTLY PROHIBITED.
d. WHEN EVER EXPERIENCE ICDJ MR & RS PRESSURE (SHOWING IN GAUGE)
SHOULD BE CHECKED AND MENTIONED IN THE LOG BOOK.
Page 23 of 105
NOTENSION ONLINE
LSDJ GOES OUT BUT UA FAILS TO DEVIATE AND LSDJ COMES AGAIN
a. If OHE damaged – lower the panto immediately. Stop the train and protect as
per GR 6.03. Contact TPC.
b. If panto is damaged – stop the train. Comply with GR 6.03 and follow
instructions on page No.56.
Page 24 of 105
OPERATION ‗A‘
Probable defects/
observation/checking Action to be taken by the Loco Pilot
REMARK - II
NOTE
IF LSDJ FLICKERS:
Page 25 of 105
OPERATION – ‗B‘
LSDJ GOES OUT, UA DEVIATES & LSCHBA GOES OUT, BUT LSDJ GLOWS
AGAIN WITHIN 15 SECONDS AFTER LSCHBA GOES OUT
Remark – 1 for SU
Remark – 2 for MU/CONSIST.
REMARK- I
Probable defects/
observation/checking Action to be taken by the Loco
Pilot
RECORD OHE VOLTAGE, SECTION AND Put HQCVAR on ‗O‘, HPH,
TIME. IF OHE VOLTAGE LESS THAN 19 KV HVSL-1 and HVSL-2 on position
CONTACT WITH TLC/TPC/SCR AND WAIT III – after operating the switches
TILL NORMALISATION OF OHE. .IF OHE a few times.
ABOVE 19 KV THEN DO AS -> Close DJ- Wait for 15 seconds.
1. IF DJ HOLDS Observe the working of both
MVSL-1 & MVSL-2.
A. IF BOTH MVSL-1 & 2 ARE WORKING. Clear block section.
On arrival at next station – Trip
DJ.
Put back HQCVAR, HPH, HVSL-
1 & HVSL-2 to position-1, one by
one.
Each time after closing DJ – Wait
for 15 seconds.
If DJ trips after putting any
switch on position-1:
Put that switch on position-III (for
HQCVAR, put on ‗O‘).
If DJ holds:
Resume traction.
Observe the working of MVSL-1
& 2 frequently.
On keeping HPH on III, observe
for abnormal rise in TFP oil level
and inform LC immediately.
Check for any oil leakage from
transformer.
Continue traction – Observe
following current ratings.
Starting – 920 amps – 10
minutes.
Continuous – 500 amps.
Inform LC.
Page 26 of 105
Probable defects/
observation/checking Action to be taken by the Loco Pilot
B. IF MVSL-1 OR MVSL-2 OR BOTH Isolate the defective blower – Clear
ARE NOT WORKING. block section.
Do not exceed the current ratings of 500
amps.
On arrival at next station:
If both MVSL-1 & 2 are not working,
Request for assistance/Relief loco.
If either MVSL1 or 2 only not
working.
Isolate the corresponding block.
Put corresponding HVSL, HVMT & HVSI
on ‗O‘
If load permits – Inform LC and continue
traction.
If load does not permit – Contact LC.
2. IF DJ TRIPS Put back HPH, HQCVAR, HVSL-1 &
HVSL-2 on position-1.
Wedge Q118 – Close DJ. Clear block
section.
Ensure the working of all auxiliaries.
Observe for any smoke emission from
auxiliaries.
On arrival at the station – contact LC.
ON WEDGING Q 118 If unsuccessful
Remove Wedge from Q118.
Ask for assistance/Relief loco
REMARK- II
Trouble shoots as per Remark-I for leading loco.
Proceed to the trailing loco.
Trouble shoot as given under Remark-I for SU and on leading loco in MU/CONSIST.
NOTE:
1. Wedging of Q118 is not permitted on trailing loco while driving from leading loco.
2. If HPH put on ‗O‘ – Follow the Standard instructions on Page No.-(iii) item – 7
3. While closing DJ if LSDJ & LSCHBA extinguishes but LSDJ glows immediately
after releasing of BLRDJ – defects in Q-30. Observe Q-30 for any smoke
emission.
4. During the course of trouble shooting, if it is required to wedge Q118 on rear
loco – Proceed to rear loco and wedge Q118 on rear loco. Clear block section
only driving from rear loco observing working of all auxiliaries following GR &
SR 4.21 in force.
Page 27 of 105
OPERATION-‗O‘
HVMT-1
0,3
Page 28 of 105
OPERATION ‗O‘
LSDJ GlOWS AGAIN WITHIN 15 SECONDS AFTER CLOSING BLVMT.
REMARK- I
Probable defects/
observation/checking Action to be taken by the Loco Pilot
Keep BLVMT switch in closed position. Put HVRH, HVMT-1 & 2 on position-III,
Close DJ, wait for 15 secs.
1. IF DJ TRIPS Put the above switches on position-1.
Wedge Q118.
Close DJ, close BLVMT and Observe the
working of blowers of MVRH, MVMT-1 & 2.
Clear block section.
2. IF DJ HOLDS Check the working of Blowers
On arrival at station,
Put back the above switches one by one on
position-I. Close DJ. Close BLVMT.
If DJ trips on putting any switch on position-1:
Maintain that switch on position-III.
Put all other switches on position-I.
Resume traction –
Observe the working of the blower, whose relay
is isolated.
NOTE:
1. Wedging of Q118 Is Not Permitted On Trailing Locos While Driving From
Leading Loco.
2. During the course of trouble shooting, if it is required to wedge Q118 on rear
loco – Proceed to rear loco and wedge Q118 on rear loco. Clear block section
only driving from rear loco observing working of all auxiliaries following GR&SR.
3. There is no provision to wedge Q118 in Microprocessor loco (except MPCS
version -3), clear block section with 5 notches.
OPERATION-‗1‘
HVSI-1
0,3
HVSI-2
0,3
Page 30 of 105
OPERATION –I
LSDJ GLOWS AGAIN WITHIN 15 SECONDS AFTER TAKING ONE TRACTION
NOTCH
Remark – 1 for SU
Remark – 2 for MU/CONSIST.
REMARK- 1
Probable defects/
observation/checking Action to be taken by the Loco Pilot
Put HVSI-I & II on position-III, Close DJ, Take one traction notch and wait for 15
secs.
1. IF DJ HOLDS Check the working of MVSI-1 & 2
i. If MVSI-1 & 2 are working:
Clear the block section.
a. On arrival at station –
Open DJ, Put back HVSI-1 & 2 one by one on
position-I, Close DJ.
Take one traction notch and wait for 15 seconds.
If DJ trips:
Put that HVSI switch on position III.
Put the other HVSI on position-I. Resume traction.
Observe the working of blower whose relay is
isolated.
2. IF DJ TRIPS i. Put the HVSI-1 & 2 on position ‗I‘.
AGAIN - Check SMGR reducing valve and ensure the
pressure 3.0 to 3.5 kg/cm², resume traction.
If unsuccessful, operate GR manually few times
Resume traction if unsuccessful, operate BL few
times on both cabs.
ii. If unsuccessful.
Isolate the RSI blocks one by one.
If load permits – Resume traction.
iii. If Unsuccessful – Clear Block Section by Manual
Control of GR.
3. IF MVSI-1 OR Isolate the corresponding block.
MVSI-2 IS NOT Put the corresponding HVSI-1 or 2, HVSL-1 or 2 and
WORKING HVMT-1 or 2 on ―O‖ If load permits – Resume traction.
If the load does not permit – Contact LC.
REMARK- II
Trouble shoot as per Remark-1 for leading Loco. Check proper fitment of MU
Jumpers & proceed to trailing loco.
Do the same operation on trailing loco.In MU CONSIST-Follow the instructions as
given under Remark-1 for SU/Leading Loco.
Page 31 of 105
OPERATION – II
HVMT-1
(0,3)
HVMT-2
(0,3)
Page 32 of 105
OPERATION –II
LSDJ GLOWS AGAIN WITHIN 15 SECONDS AFTER TAKING SIX TRACTION NOTCHES
Remark – 1 for SU
Remark – 2 for MU/CONSIST. .
REMARK- I
Probable defects/
observation/checking Action to be taken by the Loco Pilot
Ensure HVRH, HVMT-1 & 2 on position-I, Close DJ, Close BLVMT, Check the
working of blowers.
1. IF ALL THE a.i. On locos provided with HC 105
BLOWERS ARE Put HC 105 on ‗O‘ –close DJ do test for OP-II.If DJ
WORKING holds Resume traction
Observing the working of blowers on run.
ii. On locos not provided with HC 105
Put HVMT-1 & 2 on position-III. Close DJ, test for
OP-II. If DJ holds
Resume traction and observing the working of
blowers on run.
b. If unsuccessful.(DJ NOT HOLD)
Put back all switches in position-I.
Wedge Q118. Clear block section.
Observing the working of auxiliaries.
c. On arrival at station:
Take safety measure.
Remove the wedge from Q118.
Operate manually – C107, C106 and C105
Resume traction.
If unsuccessful.
Take safety measures – Wedge C107.
Put HVRH on III/Operate Q118 manually. Close DJ-
Resume traction.
If again unsuccessful – Request for assistance.
2. IF ALL THE a. Close BLCPD. Check the working of compressors.
BLOWERS ARE i. If the compressors are working:
NOT WORKING. Take safety measures.
Wedge C107, C106 and C105 manually operated
Q 118. Close DJ. Resume traction.
ii. If the compressors are not working – Refer
Troubleshooting of ALL AUIXILIARY NOT
WORKING.
3. IF ONE/MORE I Take safety measure. Wedge the corresponding
BLOWERS ARE contactor. Put corresponding switches on position –
NOT WORKING. III/manually close Q-118. Close DJ. Resume
traction.
Page 33 of 105
REMARK – II
Trouble shoots as per Remark-I for leading loco.
Proceed to the trailing loco.
Do the same operation on trailing loco as given under Remark-I for SU/leading
loco.
During the course of trouble shooting:
When one or more blower contactors are wedged.
Put HVMT1, HVMT2 and HVRH on position III.
Check Q118.
i. If Q118 is energized.
Come back to leading loco – Resume traction.
Page 35 of 105
Probable defects/ Action to be taken by the Loco Pilot
observation/checking
(On all locos in MU/Consist)- Resume
traction.
NOTE:
Page 36 of 105
( CHAPTER – II )
TRACTION FAILURE
Page 37 of 105
Page 38 of 105
Page 39 of 105
TRACTION FAILURE
Probable defect/
Observation/ Checking Action to be taken by the Loco Pilot
I. IF LSB GLOWS Take safety measures. Ensure the following.
[MPJ on ―F‖ OR ―R‖] i. J1 & J2 is in desired direction.
Driving Position of Direction of Direction of
cab MPJ J-1 J-2
Cab-1 Forward UP UP
Cab-1 Reverse DN DN
Cab-2 Forward DN DN
Cab-2 Reverse UP UP
Page 40 of 105
II. IF LSB IS Check and ensure the following:
EXTINGUISHED 1) BP pressure to be 5 kg/sq.cm.
2) Observe Auto Flasher light, if flashing, reset. If not
[MPJ on ―F‖ OR ―R‖] resetting, remove CCLSA (in MPCS loco try with
bypassing Q-51 by putting HPAR or HQ51 on ―0‖.
3) If QRS is in de-energized condition, Wedge QRS in
energized condition.
4) Check Proper fitment of MP couplers (2 Nos).
5) Operate EEC- Resume traction.
If unsuccessful :
Try with MP or EEC from rear cab and clear block
section only (observing GR & SR in force).
ON ARRIVAL AT STATION-OR IF unsuccessful
6) Ensure ZSMGR knob and ZSMS are in correct
Position.
7) Check SMGR pressure 3.0 to 3.5 kg/cm2
8) Operate BL few times.
9) Check Q51, if energized condition, then wedge Q 51 in
de- Energized condition and resume traction.
10) Check Q52, if Q52 is in energized condition- Wedge
Q52 in de-energized condition - Resume traction.
IF Q51 & Q52 are good (i.e. DE-ENERGISED) or
If unsuccessful:
11) Operate GR manually few times from ‗0‘ to 10 & back
to ‗0‘ and resume traction if unsuccessful.
12) Clear block section by manual control of GR in
SU/Leading loco.
In MU:
If load permits – clear block section with good loco. If load
does not permit – contact LC/SM/SCR for assistance
loco.
Page 41 of 105
TOTAL LOSS OF TRACTIVE EFFORT
OR
IMPOSSIBILITY TO START DURING TRACTION, AMMETERS DO NOT DEVIATE
1. b. GR IS PROGRESSING
Probable defect/
Observation/ Checking Action to be taken by the Loco Pilot
GR is progressing but ammeters Ensure MR pressure is 8 kg/sq. cm.
are not deviating. Try from rear cab- Clear block section
observing GR & SR rules in force.
If unsuccessful from rear cab or on
arrival at the station.
Operate HVSI-1, HVSI-2, HVMT-1 and
HMVT-2 few times from 1 to 0 and back to 1.
Operate HMCS-1 & HMCS-2 few times from
1 to 4 and back to 1.
Manually operate line contactors few times.
Manually operate all CTFs few times.
Ensure they are in ‗TR‘ (UP) Position.
Check for any air leakage from line
contactors or its pipe line – try to arrest the
leakage.
Check EP cut out cock. If close, open EP
cocks.
Check 3 numbers BD couplers below rotating
switch board for proper fitment. .
Resume traction.
Operate relay Q50 few times and try again.
If unsuccessful, drain out the MR pressure
and try again.
NOTE :
In MU / Consist – During starting or on run -
If ammeters on leading loco deviate abnormally high, check the trailing loco.
If GR progressing but both ammeters do not deviate refer 1.b. above
If both ammeters are deviating on all locos check the train for brake
binding.
Page 42 of 105
TOTAL LOSS OF TRACTIVE EFFORT AFTER USING RHEOSTATIC BRAKING
Probable defect/
Observation/ Checking Action to be taken by the Loco Pilot
I. IF LSB DOES NOT GLOW Ensure MP on ‗O‘ and observe glowing of LSB
putting MPJ on ‗F‘ or ‗R‘. If LSB does not glow,
trouble shoot as per page number: 41 (Trouble
Shooting for TLTE).
II. IF LSB GLOWS Take safety measures and-
a) Check CTF-1, CTF-2 & CTF-3 are in ‗TR‘
(UP) position.
If CTFs are on ‗BR‘ position – bring them to
‗TR‘ position. (Manually operate the CTF
electro valves).
Ensure C145 is in open condition, If C-145 is
closed – Open C145. (Manually operate the
CTF electro valve) and resume traction.
If unsuccessful – try from rear cab.
Resume traction – Clear block section
observing GR & SR in force.
If unsuccessful – clear block section by manual
control of GR in case of SU/leading loco in
MU.
In MU/consist:
NOTE:
On opening EP cut out cock if any CTF again back to BR position. Secure
that CTF with rope in the TR position and do not use RB.
Page 43 of 105
REDUCTION /LOSS OF TRACTIVE EFFORT
Page 44 of 105
TLC & record in the loco log book.
On locos having two voltmeters and one ammeter in each cab
(modified) observe both ammeters on both cabs whenever required.
Do not use MPS If auto regression takes place with LSP glow.
ISOLATION OF TRACTION MOTORS
Probable Defect/
Observation/Check Action to be taken by the Loco Pilot
Ensure QVCD is de-energised in case of VCD fitted loco.
IF QVCD ENERGISED If energised. Reset VCD
If still energised, Put HBA on ―0‖ then again on ―1‘
and try.
If unsuccessful – isolate VCD by HVCD.
If unsuccessful wedge QVCD in de-energised
condition.
In case QVCD de-energised-
BL DEFECT Operate BL key & BPR switch in both cabs few
AND/OR times. Try to resume traction,
BPR in PRESSED* If unsuccessful, resume traction with EEC.
If unsuccessful, clear block section from rear cab,
Observing GR & SR rules in force.
If unsuccessful, clear block section by manual
control of GR.
Probable defect /
Observation /Checking Action to be taken by the Loco Pilot
ACTION OF Q20 If auto regression is experienced without the use of
(ENERGISED) MPS.
It may be due to the action of Q20.
Note the TM voltage at which auto regression takes
place.
Resume traction – Work at lower notches.
Note:Do not use MPS,if auto regression with LSP glow takes place on
using MPS.
Page 45 of 105
4. SMOKE OR ABNORMAL SOUND FROM THE TRACTION MOTORS:
Page 46 of 105
5. GR DOES NOT PROGRESS BEYOND ONE/CERTAIN NOTCH IN SU/MU/CONSIST
Page 47 of 105
(CHAPTER – III )
MISCELLANEOUS FAILURES
1. PNEUMATIC FAILURES
Page No.
A) MR pressure not building up/ maintaining 51
B) RS pressure not building up 52
C) BP pressure not building up/maintaining 53
D) BP pressure not building up after cattle run over 54
E) BP pressure fluctuating on run 54
F) BP not dropping by DAB/A-9 54
G) Loco brakes not releasing 54
H) ACP on WAP 4 locos 54
2. ELECTRICAL FAILURES :
Page No.
A) Pantograph failures 55
B) DJ locked in closed position 56
C) All auxiliaries are not working (CCA fuse melted) 61
D) All pilot lamps not glowing during opening of DJ 62
E) MVRH, MVMT-1 OR MVMT-2 does not start on closing BLVMT 62
F) LSCHBA glows on run (ARNO Fitted Loco) 63
G) LSCHBA glows on run without tripping (SIV Fitted Loco) 63
H) CPA does not start when ZCPA is closed 64
I) Cab lights/compartment lights are not glowing 64
J) Marker lights does not glow 64
K) Head light does not glow 65
L) Notch repeater is not working 65
M) Cab fans are not working 65
N) Cab heaters are not working 65
O) All sanders are not working 65
P) LSB glowing during RB 65
Q) LSRSI glows on run/remains glowing 66
R) LSB glows with MP is placed on ‗P‘ but does not extinguish. 66
Page 48 of 105
1. PNEUMATIC FAILURE
Note:
On trailing loco/locos in MU/Consist or dead
loco –ensure IP valve is isolated.
In MU/Consist- Ensure LT cock is in closed
position and MU-2B on trail position on
trailing locos.
Check leakage from DAB/A9 – Operate A9
few times – properly.
Drain the moisture in MR.
Gently tap C-2 relay valve for BP charging–
If necessary,
Operate few times D1/D2 – Emergency
valve if necessary,
If unsuccessful – Change the cab and work the
train from rear cab/rear loco (after isolating inter
mediate BP angle cock) in MU/Consist as per GR
& SR rules in force.
NOTE: If BP gauge shows ‗O‘ in driving Cab and 5.0Kg/Cm2 in rear Cab, then check
BP additional angle cock in rear Cab .If is in close position open the same.
Page 51 of 105
D. BP PRESSURE Isolate the additional BP angle cock ( if provided)
NOT BUILDING UP If additional BP angle cock not provided –
AFTER CATTLE Contact LC/SM/SCR for advice.
RUN OVER In case of cattle run over Loco pilot must inform
LC/SCR.
E. BP PRESSURE Use BLCPD.
FLUCTUATING ON Maintain minimum 9 kg/ cm 2 MR pressure.
RUN
F. BP NOT DROPPING Ensure A9 inlet/outlet cocks are in proper position in
BY - A9 . all cabs, LT cocks & MU2B valves are in proper
position.
Operate A9 a few times.
If unsuccessful, Drain out MR pressure and re-build.
Gently tap C-2 relay valve for BP charging.
Operate MU-2B valve few times & keep it in leading
position.
If still unsuccessful, drive from rear cab/ rear loco in
MU/Consist observing GR & SR rules in force.
Page 52 of 105
2. ELECTRICAL FAILURES
NOTE :
Page 55 of 105
Page 56 of 105
Probable defect / observation/ Action to be taken by the Loco Pilot
checking
C. all auxiliaries not Check CCA FUSE
working(auxiliaries start by own
“bl”switches) in SU
1. IF CCA GOOD Check Q -100 /QTD-100 with DJ closed condition.
If Q100/QTD-100 de-energised:
Page 57 of 105
All aux. are not working in MU First put BLSN downwards and trouble shoot
as above for single loco.
Page 58 of 105
Page 59 of 105
IN SIV FITTED LOCO : If SIV is not working – Trouble shoot for SIV fails to start.
• If SIV working but ALL AUXAILIRIES not working-- Check CCA only ,if
melted renew the same.
If unsuccessful –
Page 61 of 105
Replace fuse CCBA – Put ZCPA‖ON‖ to
start MCPA.
If the fuse is good – check the terminal of
ZCPA and CPA.
If disconnected, connect the same and try.
I. CAB/ COMPARTMENT Ensure bulb is good.
LIGHTS ARE NOT GLOWING Check CCLC.
If fuse CCLC is melted – Renew fuse.
J. MARKER LIGHTS ARE NOT Check CCLF1/CCLF2. If melted- Renew
GLOWING the same
K. HEAD LIGHT DOES NOT Put on BLPRD-If head light glows-work
GLOW normally
If head light does not glow- ensure
ZPR/ZRT is ON, if provided. If
unsuccessful.
Put ON BLPRR:
If the rear head light glows.
Check the front head light holder.
If it is good - Change the bulb (if
possible).
Page 62 of 105
Check CCVT and CCTFS if melted renew it
L. NOTCH REAPTER IS NOT if un success Continue traction.
WORKING Enter in the loco log book and inform LC
On SIV Fitted loco change the position of
HRAVT.
Checks CCVT –If melted renew CCVT.
M. CAB FANS ARE NOT On SIV Fitted loco change the position of
WORKING HRAVT.
Page 63 of 105
ii) IF 4 FUSES ARE MELTED IN Remove the melted tell tale fuses.
SAME ARM / ROW. Isolate the corresponding block. If load
permits- Resume traction. If load does
not permit-Contact LC.
NOTE: where LED indication lamp is provided instead of tell – tale fuse-
1) 6 LED lamps in one RSI block - If one LED indication Lamp is glowing, then isolate
the corresponding block.
2) 14/18 LED lamps one RSI block –
a) If one LED indication Lamp is glowing in having, operate micro switch and work
carefully observing RSI block.
b) If 2 LED indication Lamp is glowing in one RSI block - then TM to be isolated by
HMCS .
c) If more than 2 LED indication Lamp is glowing in one RSI block - then
correspondence RSI block to be isolated.
iii) IF NO FUSE IS MELTED Ignore the glowing of LSRSI.
Enter in the loco logbook – In form LC.
Resume traction.
Page 64 of 105
CHAPTER-4
A. Microprocessor. 67
B. Static Converter. 90
Page 65 of 105
MICROPROCESSOR BASED LOCOMOTIVES
1. SYSTEM CONFIGURATION:
Q20 Q30 Q44 Q45 Q46 Q48 Q49 Q50 Q51 Q52 Q100 Q118
Q119 QV60 QV62 QV63 QV64 QWC QRS QTD105 QTD106 PR1 PR2
(QCON in SIV Locos)
In some locos QD, QCVAR, QV61, Q30 are also not provided.
HQCVAR SWITCH IN THAT CASE IS NOT PROVIDED
QOA,QOP1,QOP2,QRSI1,QRSI2,QLM,QLA,QPH,QVSL1&2,QVSI1&2,QVMT1&2,QVRH,
QPDJ,QVRF,QFL(QD1,QD2,Q30,QCVAR,QV61 IN SOME LOCOS)
Fuse Provided: CCCPU (6A), In some locos MAIN UNIT is directly taking feed
from CCPT. (In MPCS VERSION-3,CCCPU is 16 AMPS)
KEY PURPOSE
ENTER THIS IS COMMAND TERMINATOR.
ACK THIS KEY IS USED FOR ACKNOWLEDGEMENT OF FAULT.
MENU USED FOR SELECTION OF VARIOUS OPERATIONS.
Page 66 of 105
CURS UP THIS ALLOWS TO SEE THE NEXT CURSOR FAULT IN MEMORY
WHEN ONE IS IN CURSOR FAULT DISPLAY MODE.
CURS DN TO SEE THE PREVIOUS FAULT IN MEMORY WHEN IN CURSOR
FAULT DISPLAY MODE.
Page 67 of 105
Page 68 of 105
INSTRUCTIONS TO LOCO PILOT:
7. In case E.M. contactors is/are not closing, trouble shoot as per TSD.
If unsuccessful keep HOBA in ―OFF and try.
If unsuccessful -wedge the contactors.
8. On pressing ACK, If the fault message on screen of display unit does not clear .
Keep HBA on ‗0‘ for 3 minutes and try. If unsuccessful keep HOBA―OFF‖ and try.
9. If tripping through any circulation relay of any aux. motor, LP shall isolate the
relay 1st and close DJ- If DJ holds- check the working of aux, motor and work
accordingly like conventional loco.
Page 69 of 105
10. If ICDJ due to feedback fail through C105 or C106 – operate C105/c106 few times
after taking safety measures and try. If unsuccessful, Put HVMT1 or HVMT2
switches on ‗O‘ and try if successful –clear block section if load permits.
11. Put HBA in ―0‘ for 3 minutes and again try to energize.
12. Try from rear cab.
13. Put HQOA in ―0‖, HQOP-1&2 in ―OFF‘ position and HOBA in ―OFF‖ and try.
14. Drain full MR/RS and rebuild the pressure and try.
15. If unsuccessful request for assistance.
2. Ensure J1, J2 and CTFs are in proper position and C145 Open.
.5. .If un success switch OFF HBA ,wait for 3 minutes and switch ON and try.
TLTE WITH LSB EXTINGUISH-
1.-Ensure SMGR pressure is between 3.0 to 3.5Kg/cm 2
Page 70 of 105
Sometimes, the fault diagnostic systems may give erratic information leading to wrong
guidance since they are not stabilized fully. Hence Loco Pilots should follow the normal
procedure of troubleshooting
Sr.
No. Fault message on display unit Duties of Loco Pilot
1 C118 N/C Contact Fail Check C 118 is opened fully.
Ensure C118 Opening Do not Press Operate C118 manually few times.
BLRDJ
2 C118 Stuck up Release BLRDJ and ensure C118 is
Ensure opening of C118 opened fully
Release BLRDJ if pressed
3 No Tension Trouble shoot as per TSD of WAG5
Wait for OHE Voltage
Retry to close DJ
4 OHE low / No Voltage Trouble shoot as per TSD of WAG5
Apply Emergency Brake
5 DJ tripped Via QOP-1
Reset QOP-1 isolate faulty TM by HMCS-1
6 DJ tripped Via QOP-2
Reset QOP-2 isolate faulty TM by HMCS-2 Trouble shoots as per WAG-5 TSD.
7 DJ tripped Via QOA
Put HQOA on 0
Check all Auxiliary / Heater, follow TSD
8 DJ tripped Via QRSI-1
Reset QRSI-1 isolate faulty TM by HMCS-
1
Follow TSD inform TLC
9 DJ tripped Via QRSI-2:
Reset QRSI-2 isolate faulty TM by HMCS- Trouble shoots as per WAG-5 TSD.
2
Follow TSD inform TLC
10 DJ tripped Via QLM
Check transformer / GR oil splashing.
11 DJ tripped Via QVSL-1
Check MVSL-1 if normal Put HVSL-1 on 3
Resume Traction
12 DJ tripped Via QVSL-2
Check MVSL-2 if normal Put HVSL-2 on 3
Resume Traction
13 DJ tripped Via QVMT-1
Check MVMT-1 if normal Put HVMT-1 on 3
Resume Traction Put corresponding switch on 3, close DJ
14 DJ tripped Via QVMT-2 and check corresponding auxiliary.
Check MVMT-2 if normal Put HVMT-2 on 3
Resume Traction - If auxiliary is working, work the train.
15 Check MVRH if normal Put HVRH on 3 - If auxiliary is not working, isolate the
Resume Traction particular auxiliary and work the train
16 DJ tripped Via QVSI-1 following relevant precautions.
Check MVSI-1 if normal Put HVSI-1 on 3
Resume Traction
Page 71 of 105
17 DJ tripped Via QVSI-2
Check MVSI-2 if normal Put HVSI-2 on 3
Resume Traction
18 DJ tripped Via QPH
Check TFP oil level frequently
Put HPH on 0 & clear block section.
19 DJ tripped due to GR stuck between Bring GR to 0 manually, close DJ and try.
notch If DJ trip again due to GR stuck up then
Bring GR to 0 manually. clear block section by manually control
Clear block section manually. of GR
20 DJ tripped due to Low / No ARNO voltage Inform to LC and ask for relief loco.
21 DJ tripped Via QLA.
Isolate faulty auxiliary machine, if fault
exists make loco dead and inform to TLC. Trouble shoots as per WAG-5 TSD.
Page 72 of 105
Press BPQD / Resume traction wheel slip, press BPQD and apply
sanders.
- If auto regression takes place due to
traction motor defects, isolate defective
traction motor.
38 Auto regression Via TM over voltage Work the train on lower notches and
Check TM voltage inform to LC
39 Braking Fault SWC Operated Ensure SA-9 is in released & BC gauge
Do not use Loco Brake during RB shows ‗O‘ and do not use RB
40 Working with One CPU Resume traction and inform to TLC.
41 EEPROM Failed Resume traction and inform to TLC.
42 Other CAB display fail Resume traction and inform to TLC.
43 Loco in LT STATUS MESSAGE during LT testing
44 Press BLDJ After energising loco STATUS MESSAGE
Select Pantograph
Press BLRDJ
45 HVMT-1 in Position 0 After isolating MVMT-1, STATUS
L-1, L-2 and L-3 cut off Half power MESSAGE
available
46 HVMT-2 in Position 0 After isolating MVMT-2, STATUS
L-4, L-5 and L-6 cut off Half power MESSAGE
available
47 HVSI-1 in Position 0 After isolating MVSI-1, STATUS
L-1, L-2 and L-3 cut off Half power MESSAGE
available
61 DJ tripped via C-105 Feed back fail Put HBA on 0 and check C-105 is opened
Put HVMT-1 on 0 fully
Clear section and inform to TLC Operate C-105 manually few times and try
to close DJ if unsuccessful wedge C-105
If unsuccessful, put HVMT-1 on 0, clear
section and inform to LC
62 DJ tripped Via C118 N/C contact fail Check C118 is fully opened.
If unsuccessful, ask for relief loco
63 ARNO not picking up Inform to TLC / ask for relief loco
64 TM voltage channel Noisy Resume traction and inform to LC.
65 V965 voltage channel noisy Resume traction and inform to LC.
66 ARNO voltage channel noisy Resume traction and inform to LC.
67 User changed configuration / Loco No. Resume traction. STATUS MESSAGE
68 Communication Link Display in Cab-2 fail Resume traction and inform to LC
69 Communication Link Display in Cab-1 fail Resume traction and inform to LC
70 RTC Fail Resume traction and inform to LC
71 V 965 Channel fail Inform to LC / Ask for relief loco
72 ARNO channel fail Inform to LC / Ask for relief loco
73 TM voltage channel fail Q-20 will not energise, work the train by
observing Voltmeter and inform to LC.
74 Auto – regression via ACP Reset ACP and work the train
75 BPAR put in bypass After putting HPAR on 0, STATUS
MESSAGE
76 BPAR restored After putting HPAR on 1, STATUS
MESSAGE
Sr.
No. Display panel / Message on screen Duties of Loco Pilot
1 C-118 N/C Contact Fail Check C-118 is opened fully
2 C-118 Stuck Up Release BLRDJ and check C-118 is opened fully.
3 OHE not available when DJ closed Trouble shoots as per WAG-5 TSD
4 No OHE when Loco Running Trouble shoots as per WAG-5 TSD
5 DJ tripped via QOP-1 Trouble shoots as per WAG-5 TSD
6 DJ tripped via QOP-2 Trouble shoots as per WAG-5 TSD
7 DJ tripped via QOA Trouble shoots as per WAG-5 TSD
Page 74 of 105
8 DJ tripped via QRSI-1 Trouble shoots as per WAG-5 TSD
9 DJ tripped via QRSI-2 Trouble shoots as per WAG-5 TSD
10 DJ tripped via QLM Trouble shoots as per WAG-5 TSD
11 DJ tripped via QVSL-1 Put corresponding switch on position 3, close DJ
12 DJ tripped via QVSL-2 and frequently check proper working of auxiliary.
13 DJ tripped via QVMT-1 - If auxiliary is working, work the train.
14 DJ tripped via QVMT-2
- If auxiliary is not working, isolate the
15 DJ tripped via QVRH
16 DJ tripped via QVSI-1 corresponding auxiliary and work the train by
17 DJ tripped via QVSI-2 taking precautions.
18 DJ tripped via QPH
19 DJ tripped due to GR Stuck Between Bring GR to ‗0‘ manually, close DJ and clear block
Notch section by manual control of GR.
20 DJ tripped due to Low or No ARNO Inform to TLC / Ask for relief loco.
Voltage.
21 DJ Tripped via QLA Trouble shoots as per WAG-5 TSD
22 DJ Tripped via QPDJ Check RS pressure, if less build up pressure by
MCPA
23 DJ Tripped via QVRF Do not use DBR
24 ICDJ due to QOP-1 Dropped Trouble shoots as per WAG-5 TSD
25 ICDJ due to QOP-2 Dropped Trouble shoots as per WAG-5 TSD
26 ICDJ due to QOA Dropped Trouble shoots as per WAG-5 TSD
27 ICDJ due to QLM Dropped Trouble shoots as per WAG-5 TSD
28 ICDJ due to QRSI-1 Dropped Trouble shoots as per WAG-5 TSD
29 ICDJ due to QRSI-2 Dropped Trouble shoots as per WAG-5 TSD
30 ICDJ due to QLA Dropped Trouble shoots as per WAG-5 TSD
31 ICDJ due to QPDJ Dropped Trouble shoots as per WAG-5 TSD
32 Reverses are Neither in ‗F‘ nor in ‗R‘ Trouble shoots as per WAG-5 TSD
33 CTFs are Neither in ‗TR‘ Nor in ‗BR‘ Trouble shoots as per WAG-5 TSD
34 GR Not in Zero Bring GR to ‗0‘ manually and close DJ
35 Brake Applied Through ‗IP‘ Close ‗IP‘ cut out cock. Do not use DBR
36 Auto Regression Via RGEB Ensure BP pressure is 5 kg/cm2 & RGEB cock
open
37 Auto Regression Via QD - If auto regression takes place due to wheel slip,
press BPQD and apply sanders.
- If auto regression takes place due to TM
defective, isolate defective traction motor and
work the train.
38 Auto Regression Via TM Over Work the train on lower notches and inform to
Voltage TLC.
39 Braking Fault. SWC Operated Ensure SA-9 is in release position and do not use
DBR
40 Working with one CPU Inform to LC
41 System Error Resume traction and inform to LC
42 Other Cab display fail Resume traction and inform to LC
43 Loco in LT During LT Testing STATUS MESSAGE
44 Auto Regression Via ACP Reset ACP
45 HVMT-1 in Position 0 While isolating MVMT-1 STATUS MESSAGE
46 HVMT-1 in Position 2 While putting HVMT-1 on position ‗2‘ STATUS
MESSAGE
47 HVMT-2 in Position 0 While isolating MVMT-2 STATUS MESSAGE
48 HVMT-2 in Position 2 While putting HVMT-2 on position ‗2‘ STATUS
MESSAGE
49 HVSI-1 in Position 0 While isolating MVSI-1 STATUS MESSAGE
Page 75 of 105
50 HVSI-1 in Position 2 While putting HVSI-1 on position ‗2‘ STATUS
MESSAGE
51 HVSI-2 in Position 0 While isolating MVSI-2 STATUS MESSAGE
52 HVSI-2 in Position 2 While putting HVSI-2 on position ‗2‘ STATUS
MESSAGE
53 Reversers Are Not as per MPJ Trouble shoots as per WAG-5 TSD
position
54 CTFs Are Not as per MP position Trouble shoots as per WAG-5 TSD
55 C 145 Open HMCS-1 & 2 Not in ‗1‘ Do not use RB
56 C 145 Open DBR overheated Do not use RB
NOTE
If any fault message comes on display unit, trouble shoot as per fault message. If trouble is not
rectified, before asking relief loco, Loco Pilot do as follows:
1. Put HOBA in OFF and try to rectify the trouble.
2. Switch off Battery for 3 minutes and try to rectify the trouble.
3. Drain out full MR/RS pressure & rebuild the pressure and try.
Page 76 of 105
MPCS VERSION-3
BLOCK DIAGRAM:-
DISPLAY SCREEN:
Page 77 of 105
OBJECTIVES OF MPCS VERSION -3
2 . VCD INBUILT.
8. BPMPR push button provided on MAIN UNIT to reset the MPCS in case of
‗INTERNAL FAULT‖ message display.
Introduction:
The Display Unit of MCS system locomotives is HMI unit through which the user can
interact with the system. It has numeric keyboard through which user interacts with the
system. It gets the information requested by user from the control system through the
serial communication Interface and display it on the Display.
Display module provides user with the necessary data of what exactly going on within
the system. It has a MENU driven operation that makes it user friendly. The display Unit
serves the following functions :
Page 78 of 105
● The input keypad is split on two sides of the LCD Display screen. The buttons on
the right of the screen have fixed functions like, brightness control, automatic brightness
control, contrast control, Display ON / OFF, Faults and Menu.
● The buttons on the right hand side of the display screen are four direction arrows
for navigation, Enter and Cancel keys.
● Twenty keys are provided on the display unit
1. Right Key Pad - 10 Keys
2. Bottom Key Pad - 10 Keys
Bottom keys:
There are 10 keys at the bottom of the display. The 10 context sensitive keys acts as
soft keys and their function changes as per the content that is displayedon the screen.
S. no Key Description
1. 1. MAIN MENU
2. 2 CREW MESSAGE
3. 3 LP INFORMATION
4. 4 LOCO STATUS
5. 5 ISOLATION
6. 6 SETTINGS
7 7 Q50 BYPASS
8. 8 QCON BYPASS
9. 9 QCVAR BYPASS
10. 0 Q118 BYPASS
Page 79 of 105
● Whenever crew occur, BPFA and LSFI lamps glow. Pressing illuminated
push button (BPFA) is taken as acknowledgment by the system for the
crew that is shown on the display screen, after acknowledgment by the
user the lamps become OFF.
● Whenever VCD Warning cycle is started, then LSVW glows.
Page 80 of 105
VIGILANCE CONTROL DEVICE-
5. FAULT DIAGNOSTICS
There are three types of diagnostic messages, which are displayed from loco
crew on the respective CAB display unit.
1. Fault Messages
● Faults are grouped as per sub system. Each fault message is assigned
to either priority 1 or priority 2 level.
● Priority 1 messages are related to DJ tripping, total loss of tractive effort,
vigilance control and system related.
● Priority 2 messages are the remaining messages which are not related to
priority 1 level.
2. Isolation Messages
Isolation messages provide the information about the sub system isolation
status.
3. Information Messages
Information messages provide information to the loco pilot about the
status of the loco operation.
Page 81 of 105
INCASE FAULTS DISPLAY-
1. If any fault comes shows on DISPLAY SCREEN.
4.The fault displays with corresponding diagnostic data code,with date, time & TSD that
is instructions to trouble shoot the same.
5. LP should read and note the fault message and trouble shoot as per instruction
display. Then press BPFA to acknowledge the fault.
8. Then fault data display screen shows all the faults which are logged in the memory
with‘ TSD‘.
9. Then LP should select TSD. After that information about TSD is displayed with
diagnostic code.
Page 82 of 105
Page 83 of 105
L1 & L2 LED LAMP.
1. These LED lamps are provided on the bottom of DISPLAY SCREEN & on the
left side of the SOFT KEYS.
2. If there is any short circuit of contactors C101/C102/C103/C105/C106/C107 the
circuit breakers DOP1/DOP4 provided on the CPU (on main unit) will be tripped
and L1 & L2 LED lamp will flashing on DDS.
3. WHAT TO DO—LOCO PILOT should open the cover of MAIN UNIT & RESET
the circuit breaker DOP1/DOP4 once.
4. This feature not provided on FDCS VERSION 1/2.
Page 84 of 105
RELAY BYPASS
1 .If there is any fault occurs due to problem in relay Q50/QCON/QCVAR/Q118
message will display on the DDS screen with yellow arrow mark appears above the
corresponding soft key 7/8/9/0 accordingly and the soft key is becomes active.
3. After pressing the soft key the corresponding relay screen comes and
BYPASS/ACTIVE information is also given in the conformation screen.
4. After pressing the soft key following options comes on display screen for loco pilot-
5. Display shows bypass with red arrow mark in the screen for bypassing and active for
removing bypass.
6. This wedging status shall be considered only until the relay is faulty. Once the relay
is healthy ,the relay functions normal automatically & Corresponding relay wedging
shall be removed by the system.
Page 85 of 105
Page 86 of 105
IF DJ TRIPPED & INTERNAL FAULT MESSAGE OF MPCS SHOWS ON DISPLAY.--
--
1 .ACK the fault and try to reclose DJ. If successes resume traction.
2. If not success ,open the door of the MAIN UNIT/CPU and reset MPCS
SYSTEM by pressing the push button ‖BPMPR‖ located on MAIN UNIT/CPU of
MPCS.
3.,Press push button for 5 SEC‘S and release ,then reclose DJ. If success
resume traction.
4. In case FAULT persists call for relief loco.
Page 87 of 105
STATIC INVERTOR LOCO
Page 88 of 105
i) Release the BLRDJ switch as per the practice being followed in the case of
ARNO fitted loco, irrespective of one or the other loco is fitted with ARNO or
SIV.
ii) Take initial ‗6‘ traction notches slowly enough after closing of DJ to ensure that
in event of the rear loco being fitted with SIV , it does not trip through air flow
relay as the blowers take little time to start in SIV loco.
5. During ICDJ trouble shooting in SIV loco: loco pilot to check Q44 instead of C118
for recognizing the electrical /pneumatic failure as there is no provision of C118 in SIV
loco.
(A) RESET:
Page 89 of 105
(A) RESET: To reset SIV press OK
push button provided on SIV panel till
the RED fault lamp on SIV goes off and
LSSIIT is extinguished.
SIEMENS
Page 90 of 105
A) RESET: Press ‗RESET‘ button on
STC body.
(B) ELD By-pass: Press ‗ENT‘ button
by-pass active message display and
ELD by-pass lamp glows on STC body.
Note: HRAVT & HSIV switch not
provided.
(C) To find fault data:
(i) Press-1 to view voltage, current, BA
voltage, Frequency & CHBA voltage
etc.
(ii) Press-2 fault data enquiry fault
Then press UP & DN cursor to find
current fault.
BOMBARDIER
Page 91 of 105
TRIPPING THROUGH RELAY QSIT ( LSSIT GLOW)-IN SIV FITTED LOCO.
CHECK SIV PANEL FOR FAULT INDICATION---
1. IF INTERNAL FAULT INDICATION LAMP GLOWING ON SIV PANEL:
Check for any smoke, fire and burning smell from SIV and also message on display
screen.
If FAN fault message displaying:-
Reset the Fan MCB if provided, reset SIV ,close DJ and resume traction.
If MCB not resetting ask for relief loco.
If MCB not provided, press ‗RESET‘ push button.
If not success, close IP valve, put HBA from ‗ON‘ to ‗OFF‘ and to ‗ON‘.
If successful, open IP valve and resume traction.
If not success ask for relief loco.
If OVER TEMPRATURE fault message displaying:-
Wait for 10 minute, then Reset SIV ‗RESET‘ button and then close DJ
If fault clear and DJ holds resume traction.
If fault comes again, close IP valve, put HBA from ‗ON‘ to ‗OFF‘ and to ‗ON‘. Then
close DJ.
If successful (DJ holds) open IP valve and resume traction.
If not success, ask for relief loco.
If fault displaying Except Fan/Over temp. Fault message:-
Press SIV ‗RESET‘ push button. Close DJ
If fault clear and DJ holds resume traction.
If same fault comes again close IP valve, put HBA from ‗ON‘ to ‗OFF‘ and to ‗ON
‘&.close DJ
If successful, (DJ HOLDS) open IP valve and resume traction.
If still not succeeded, isolate loads one by one and try.
If not success, ask for relief loco.
2, EXTERNAL FAULT INDICATION ON SIV PANEL:
Check for any smoke, fire and burning smell from SIV, all auxiliary motors, contactor
panel,switch board and also ensure all contactors are open and check the message on
display screen. If any abnormality noticed: use fire extinguisher and isolate the same, reset
SIV close DJ resume traction and clear block section as per STANDARD INSTRUCTION.
A). If no abnormality but, ‗EARTH FAULT‘ message is displayed & loco is on block
section:-
Press Reset button
Put HSIV on ‗0‘.
Press earth fault/ELD bypass button. Close DJ.
Work up to 45 min. And clear block section.
Page 92 of 105
On arrival at station put HSIV on ‗1‘and trouble shoot as per‖ other than earth fault
message.
B). OTHER THAN‗EARTH FAULT‘ message displayed:-
Remove CCSPM fuse if provided. Trip AC MCB if provided.
Put HRAVT on ‗0‘ position.(If HRAVT not provided remove CCRA1&2,open
BLRA1&2, remove CCVT fuse).Reset SIV close DJ.
If successful (DJ holds), resume traction.
If not success (same fault comes again), Open BLCPA and BLVMT, reset SIV try to
close DJ.
IF DJ HOLDS WITH BLCPA & BLVMT OPEN:-
Close BLVMT only.
IF DJ TRIPS with same fault message: Put HVRH, HVMT-1 & HVMT-2 on ‗0‘
one by one ,reset SIV and close DJ.
IF DJ HOLDS after putting any of the switches on ‗0‘ work as per standard
instruction.
IF DJ HOLDS WITH BLVMT CLOSED:-
Close BLCPA.
IF DJ TRIPS with same fault message : Change the position of ZCP/HCP reset
SIV close DJ .If DJ holds keep HCP/ZCP on that position where DJ holds.
IF DJ TRIPS WITH SAME FAULT WITH BLCPA & BLVMT OPEN:-
Put HVSI-1, HVSI-2, HVSL-1, HVSL-2 and HPH on ‗0‘ one by one reset SIV and
close DJ.
IF DJ HOLDS after putting any switches on ‗0‘, work as per standard instruction.
IF UNSUCCESSFUL OR FAULTS NOT TRACEABLE IN BLOCK SECTION:-
Put HSIV on ‗0‘.
Press earth fault/ELD bypass button ,close DJ and
Work up to 45 min. And clear block section.
3. DJ CLOSE BUT SIV DOES NOT START WITHOUT ANY INDICATION ON SIV
PANEL (LSDJ extinguish, UA will deviate but LSCHBA will not extinguish,
Auxiliaries sound will not come):-
Check OHE voltage if in between 16.5 KV to 31 KV.
If OHE voltage is normal, Check CCINV fuse – If melted – Replace CCINV.
If melts again put HOBA ‗OFF‘ in all loco/locos in case of MU/Consist – Renew
the fuse and try.
If unsuccessful – Request for assistance.
IF CCINV GOOD: Close BLVMT first then close DJ .
If unsuccessful – Put HBA on ‗0‘, wait for 2 sec. and try again.
If unsuccessful – Put HOBA ―OFF‖ and try again.
If not successful -- Isolate loads one by one and try.
Page 93 of 105
This trouble may be due to over temperature. So, wait for 10 minutes and try again
to close DJ/VCB. If trouble not rectified, after that ask for assistance loco.
4. SIV FAILS TO START WITH indication lamp glowing “Input voltage out of range /
Input voltage in range”on SIV PANEL.
After closing VCB if LSCHBA not extinguish and auxiliary sound is not coming.
Check SIV panel. If lamp indication of ―Input voltage out of range/ Input voltage in
range‖ is glowing,
ii) If OHE voltage within range but still unsuccessful, close IP cock, put HBA on ―0‖
wait for 2 sec. and put back to ―1‖ & try again.
Indication for input voltage on various make SIV:
Page 94 of 105
5 ABB IP VOLTAGE NOT IN When voltage not in range it will
RANGE glow
6 AAL INPUT VOLTAGE OUT When voltage not in range it will
OF RANGE glow
(**)
** In AAL make SIV after HBA ‗ON‘ to till VCB close Input voltage out of range led will
glow.
CONTROL CIRCUIT OF
BLOWER CONTACTORS (STC)
CCA (6A) DJ
CCINV (6A)
BLVMT 1 BLVMT 2
QSVM QSVM
QV60 R B
R
01 2 3 01 2 3 012
S 3
QSVM 2SEC
TS
C HVRH HVMT-1 HVMT-2
C107 C105 C106
If both fuses are good, check QSVM relay in DJ close condition after closing BLVMT..
If not energized, wedge QSVM in energize condition. Close BLVMT before closing
DJ/VCB, if SIV will start along with all blowers resume traction..
If QSVM is in energies condition and still SIV fails to start then try by wedging QSVM
In de-energies condition, put BLVMT ‗ON‘ before closing DJ.
If unsuccessful – Put HBA on ―0‖ for few seconds and again put on normal and try.
Page 95 of 105
NOTE : During trouble shooting following should be ensured:-
1. Whenever HSIV kept on ‗0‘ and ELD bypass check the auxiliaries and SIV for any
smoke or fire in every 15 minutes.
2. After every tripping due to fault in SIV troubleshoot as per procedure, reset the
SIV then close DJ.
3. If it is required to put HBA on ‗0‘ for resetting the SIV / MPCS, isolate the ‗IP‘
isolating cock first. Again put on service after putting HBA on ‗1‘.
4. .Whenever tripping on line, check LSSIT lamp, if glowing then check QSIT relay
along with safety relay targets. If QSIT found energize and no safety relay
dropped then check the SIV panel for Internal/External fault lamp glowing. If
Internal/External lamp glowing troubleshoot for the same observing fault
messages in SIV display.
5. If no safety relay drop and QSIT not energies pick up checking sign as per
ARNO loco.
6. While pick up checking sign for Operation- ‗B‘ & ‗O‘, always count 15 sec after
extinguishing Of lamp LSCHBA .
7.For Operation- ‗I‘ & ‗II‘, take traction notch after extinguishing of lamp LSCHBA
.
Page 96 of 105
IN CASE ICDJ IN SIV FITTED LOCO :
If LSSIT is glowing/QSIT is check SIV panel and do the trouble shooting as per
energized. lamp indication.
Page 97 of 105
WHILE CLOSING DJ IF LSDJ GOES OUT, UA deviates, release BLRDJ,
if LSDJ GLOWS AGAIN BEFORE LSCHBA GOES OUT in SIV FITTED
LOCO OPERATION—A
―FOR SINGLE UNIT‖
Page 98 of 105
OPERATION-B
In SIV Fitted loco while pick up checking sign in case LSDJ goes out, UA
deviates release BLRDJ- Count 15 Sec after LSCHBA extinguish – If LSDJ
glows again check safety relays and QSIT/LSSIT, if all are normal that is
tripping in operation-B.
Probable defect Action to be taken by the Loco Pilot.
observation/checking
1.MPH/QPH,MVSL1/QVSL1, Close BLVMT first and then check for
MVSL2/QVSL2 operation –B tripping again-
2 .N/C interlock of C105/C106/C107 If DJ holds-resume traction (always
on Q118 branch. close BLVMT before Closing DJ.
IF DJ TRIPS- Put HPH, HVSL-1 and
HVSL-2 on position III after operating
the switches a few times
Close DJ and count 15 sec.
OPERATION--O
If there is no tripping up to operation-B,close BLVMT and wait till
LSCHBA extinguish ,if DJ trips within 15 sec‘s check safety relays
and QSIT/LSSIT,if all are normal it is operation –O.
TROUBLE SHOOT AS PER ARNO LOCO.
OPERATION—1
If there is no tripping up to operation-O, take one traction notch and
,if DJ trips within 15 sec‘s check safety relays and QSIT/LSSIT,
if all are normal it is tripping in operation-1.
TROUBLE SHOOT as per ARNO loco.
NOTE- -Always take traction notch after LSCHBA extinguish
OPERATION-II--
If there is no tripping up to operation-I ,take six traction
notches, if DJ trips within 15 sec‘s ,check safety relays, QSIT/LSSIT if
all are normal it is tripping in operation –II.
TROUBLE SHOOTING-----
1. Ensure switches HVRH,HVMT-I and HVMT-2 should be in 1 or 3.
2. Close DJ close BLVMT and check contactor C105, C106 & C107are
In close position.
3. If C107 not closing first ensure that CTF‘S are in TR position.
4. If any contactor not closing clamp the contactor and try.
5. If contactors are closing trouble shoot as per ARNO loco.
6. Remember that HC105 is not provided in SIV fitted locos.
NOTE-After wedging blower contactors no need to operate Q118 manually
to close DJ.
Position of HRAVT switch:-
HRAVT Cab heater Cab fan Notch repeater Charger
position
0 Isolated Isolated Isolated Isolated
1 Working Working Working Working
2 Isolated Working Working Working
3 Isolated Isolated Working Isolated
Page 99 of 105
110V DC
CCA (6A) BLOWERS CONTROL CIRCUIT (STC)
+ VE
GR CL QVRF
0-5
DJ
CTF1
(BR)
CTF2
(BR)
CTF3
(BR)
HMCS 2
CTF 1 (TR)
C107
2Sec
BA -VE
QSVM C107 C105 C106 C145 C108 LSDBR
QCON
F R F R
MPJ
FROM
CCPT 1 2
1 2 1 2 (005) CTF1
BLCP BLCPD CL ON BR CCLSA
(6A)
C 101 PVEF1 PVEF2
RGCP
CUT IN 8 Kg/Cm² CTF2
CUT OUT 9.5Kg/Cm² C 102 CL ON BR
Q 119
QTD101 5Sec
5Sec C 103
Q119 HCP
5Sec CTF3
3
CL ON BR
QRS2
406 407 408 629 421
400
5Sec 5 sec
B-VE
1 2 3
VEAD QTD101 C 101 C 102 C 103 Q 119 VEF( E )
VEUL S
It is fitted in between MR-2 and MR-3. It comes into function when compressors are
working. While air dryer is in service, slight exhaust of air takes place continuously from
purge valves alternatively. This should not be considered as leakage.
If only MR is not maintaining due to air leakage from air dryer, air dryer may be isolated
– mention in the log book with date and time.
Note :
Service – Cock ―A‘ & ―B‖ open – ―C‖ close.
Isolate -- Cock ―A‘ & ―B‖ close – ―C‖ open.
2. TLTE – A1 & A2 both Put ZSMS switch on position – Ensure Q49 and Q52 are De-
are ‗0‘. ‗0‘in all locos of MU or consist (If energized. If energized Wedge
A) GR not progressing needed) for EEC and ensure on Q49 and Q52 in De – energized
at all ‗1‘ while Resume Traction with condition on all Locos
MP operating from leading loco.
B) GR is progressing
3. GR Safety Valve Blown Isolate VEPT both cut out cocks Ensure fire, if any is properly
close BLDJ. Press BLRDJ extinguished. Ensure there is
Release BLRDJ after 3 to.5 secs Smoke Emission due to oil
Resume Traction Clear Block spread near GR. Ensure both
Section. Pantos are Lowered on Leading
Loco.
4. If DJ trips through QGR Check for any abnormality near Ensure there is no oil spread
GR If no abnormality is noticed. near GR. Oil Level in the GR oil
Reset the relay target. Close DJ gauge is between + 20 and –20
Resume Traction. degrees.
5. If DJ trips through QGR Isolate VEPT both cut out cocks Ensure both pantos are
again. Close BLDJ. Press BLRDJ Lowered on Leading Loco.
Release BLRDJ after 3 to5
seconds Resume Traction. Clear
Block Section.
6. Smoke Emission From Take safety Measures. Ensure both Pantos are
ARNO Extinguish the Fire. Isolate Lowered on Leading Loco.
VEPT both cut out cocks. Close
BLDJ. Press BLRDJ Release
BLRDJ after 3to.5 secs. Resume
Traction.
7. MR Air Hose Pipe Isolate MR Air Hose Pipe cutout Ensure Pressure is more than
Burst cocks on both locos. Close 8Kg / Cm2. If less, Build up RS
BLDJ press BLRDJ Release pressure individually on both
BLRDJ after LSCHBA goes out. Locos.
Resume Traction.