Trouble shooting

Directory of

WAM-4(6P), WAG-5, WAG-7


&
WAP-4
LOCOMOTIVES

Page 1 of 105
CONTENT

SL NO SUBJECT Page No
From To
1. Scope of the Manual 3 3
2. Standard instruction for loco pilot & Loco 3 5
controllers
3. Current rating of Traction Motors for Electric 5 5
locomotives
4. General information and trouble shooting of VCD & 5 7
C2N Feed Valve
5. Instructions about Auto Flasher light. 8 8
6. Different Pneumatic panel 9 12

7. TSD for WAM-4(6P), WAG-5, WAG-7 & WAP-4 13 65


locomotives.

8. Microprocessor based locomotives 67 89


9. Static Converter loco 90 104
10. Precautions on relay wedging 105 105
11. Air Dryer 106 106
12. Working from leading loco in MU/Consist when 107 107
leading loco defective
13. Parts of OHE (Cantilever) 108 108
14. Parts of Pantograph 109 109

Page 2 of 105
WAM-4(6P), WAG5, WAG7,& WAP-4 LOCOMOTIVES

SCOPE OF THE MANUAL

This manual briefly describes the various steps to be taken by the Loco Pilots in case of
loco troubles on line.
The prescribed trouble shooting procedures laid emphasis on quick trouble shooting and
faster clearance of block sections in case of a mid-section failure.
This manual deals with the trouble shooting of locos as single, multiple and consists.

STANDARD INSTRUCTIONS FOR LOCO PILOTS AND TRACTION LOCO


CONTROLLERS

1. During trouble shooting in block section, utmost care should be taken to trouble
shoot the fault, and resume traction within 10 minutes. If unsuccessful
LC/TPC/CONTROL to be informed within next 10 minutes, for assistance. All
efforts should be made to minimize the detentions in block section.

2. In MU/Consist, if one of the loco fails, try to clear block section with good
loco/locos without wasting time for trouble shooting.

3. In case of trouble shooting in MU/Consist locos, the abnormal sign should always
be picked up from leading loco. There after all the observations and interventions
shall be made on the loco which is defective. [Always check the proper fitment of MU
jumpers].
4. When ever HOBA is placed in ‗Off‘ position during trouble shooting in one of the loco
in MU/Consist, HOBA of other locos also to be kept in ‗Off‘ position.

5. (a) During manual operation/wedging contactors or relays, ensure the operation of


auxiliary contacts with full crushing and contactors do not chatter after wedging.

(b) While Q-118 manually operated, release it after all blowers start or after 1
minute.
(c) While operating GR manually, ensure GR on ‗O‘ by anticlockwise movement.
6. LC should be informed at the normal stoppage regarding wedging of
relays/contactors.
(a)FOR WEDGING CONTACTORS: i) Take Full Safety measures. If C105, C106
& C107 are wedged, Q118 is to be
manually operated for closing DJ in ARNO
base loco.
ii) After isolating any auxiliary motor through
rotating switch, ensure its corresponding
contactor is properly opened.

Page 3 of 105
b) FOR WEDGING RELAYS: First switch off battery.
i) If relay Q118 is wedged- block section
may be cleared observing working of all
auxiliaries.
ii) Wedging of Q118 is not Permitted in
trailing Loco/Locos while driving from
leading loco.
iii) During the course of trouble shooting, if
it is required to wedge Q118 on rear loco –
Proceed to rear loco and wedge Q118 on
rear loco. Clear block section only driving
from rear loco observing working of all
auxiliaries following G&SR in force.
iv) Wedging of relay Q-44 & Q-45 is strictly
prohibited.
7. (a) During trouble shooting if MPH is isolated, the train can be worked up to the
destination provided MVRH is working normally and there is no appreciable rise
in the oil level in the transformer gauge.

The following current ratings to be observed.

Starting : 920 amps for 10 minutes.

Continuous : 500 amps

The loco should be withdrawn in a planned manner by the LC.


(b) In case MVRH is isolated- clear block section with the following current ratings.

Starting : 920 Amps for 10 minutes.

Continuous: 500 Amps.


(c) In case MVSL is isolated – Clear block section with the current rating of 500
Amps (Maximum).
8. During trouble shooting if HQOP/HOBA is kept ‗OFF‘ or HQOA is on ‗O‘ a frequent
watch should be kept for any smoke emission from power equipments i.e. RSI
blocks, TMs, BA & TK panel and Auxiliaries etc., as the case may be. LC should be
informed at the first opportunity. LC should withdraw the loco with HQOP/HOBA in
OFF or HQOA on ‗O‘ in a planned manner and direct the loco to the nearest shed for
attention.

9. Whenever any equipment (including TM)/relay is isolated on a locomotive, Loco Pilot


must record in the loco log book and inform LC at the first available opportunity.

LC must ensure planned withdrawal of the loco from service.


10. The Loco Pilots must record all cases of on line loco troubles/other unusual
occurrences/wheel slipping, clearly mention the time loss in block section/station,
time and place of occurrence as well as information given to LC (with name).

Page 4 of 105
11. Check availability/working of following safety equipments.
a. Flasher lights, Auto Flasher light, Marker lights, Head lights, Horns, Wipers,
Speedometer, Sanders and availability of dry sand in the sand boxes.
b. Portable telephone/Fire extinguishers/detonators/wooden wedges.
12. In case of ICDJ & TLTE, failed to rectify according to tripping and Traction failure,
drain out MR & RS pressure, close DJ/VCB and resume traction after rebuilding of
RS & MR pressure.
13. During the course of trouble shooting, if it is required to switch off HBA, IP C.O.C.
must be isolated before switching off HBA and it should be kept normal after
switching ON HBA.
14 IP C.O.C. must be kept isolated in trailing loco/locos in MU/ Consist and in dead
loco.

Current Rating of Traction Motors For Electric Locomotives

Starting Current (Amps) Acceleration Continuous


Type of loco 2 min 10min. 60 min.
WAP1 1100 1000 840 750
WAP4 1250 1100 960 900
WAM-4 (6P)` 1100 1000 840 750
WAM4 (SP) 1100 1000 750 667
WAG5 (TAO 659) 1100 1000 840 750
WAG5 (HS15250) 1200 1100 840 750
WAG7 1300 1100 960 900

General information and Trouble shooting of VCD

LED indications and other items on VCD cab unit

Name of LED Colour Function


HEALTHY Green Glows as soon as BL is unlocked & shows
the system is healthy.
FAULTY Red Glows In case of any internal faults in the
system.
WARNING Yellow Flashes when none of the operations
continuous period of 60 sec, / Reset button
is pressed for continuously 60 sec.
VCD BYPASS Red Manual bypass switch HVCD put on ‗O‘ ,
VCD goes into bypass mode
VCD ACK push button - For acknowledge VCD

Page 5 of 105
INSTRUCTIONS TO BE FOLLOWED FOR VCD LOCOS
 Vigilance Control Device (VCD) monitors alertness of the engine crew on continues
basis by checking his actions while running a train.
 VCD consists of one control unit, two display unit (one on each cab), relay QVCD &
isolation switch HVCD.
 On putting BL key on BL box (Unlock), the VCD will become active but will remain in
suppressed mode. When pressure in locomotive build up, the VCD will start
functioning.

1. Engine crew should do any of the following operation once in 60 seconds for non
actuation of VCD:
a) Notch up/Notch down by master controller or EEC;
b) Brake applications through A9
c) Application of sander;
d) Pressing VCD acknowledgement push button available for LP.
e) Pressing of foot switch available for LP;
f) Operation of first shunting notch i.e. MPS-1
2. Actuation of VCD:
a) If none of the above operations is done within 60 seconds, a yellow flashing light will glow
for 8 seconds.
b) Even after that no operation is done then an alarm will sound along with yellow flashing light
for another 8 seconds.
c) Even after that (total 76 sec) if no operation is not done then VCD will actuate & apply
penalty brake automatically for 32 seconds and auto regression will take place. During
brake application only yellow flashing light shall glow.
3. Resetting of VCD:
Wait for 32 sec after penalty brake application.
Keep MP on zero position and then push the Reset push button available at driver desk.
(Pressing of reset button before 32 second shall not reset the VCD).

Page 6 of 105
4. Bypass / Isolating of VCD:
 If RED LIGHT (FAULTY) flashes on VCD cab unit it indicates VCD has become defective.
 Put Bypass Switch HVCD on position ‗0‘ from ‗1‘ to bypass VCD duly endorsing in the log
book and inform TLC.
 Ensure the glowing of Bypass lamp in VCD cab unit & displaying VCD bypass in VCD
main unit and resume traction.

5. If VCD is mal-functioning & not bypassed even putting HVCD on ‗0‘:


 Trip the loco & Put HBA ‗OFF /ON‘
 Wedge the relay QVCD in de-energized condition
 Isolate IP valve cock
 Then energise the loco & resume traction. Enter in loco log book & inform TLC
6. When BL key is inserted, then VCD goes in ―self-check‖ mode. If the IP/E3W valve cock is in
closed condition then VCD will log the event as IP isolated.
7. VCD will remain in ―Sleep mode‖ when
1. In trailing loco in the MU operation.
2. Application of A-9/SA-9
3. Manual control of GR
8. Note:
1) Ensure IP valve COC in open position to avoid mal-functioning of VCD.
2) Vigilance acknowledgement Push Button/foot paddle switch should not be pressed for more
than 60 seconds continuously.
3) In standing condition, apply SA-9 (more than 1.5 kg/cm2) otherwise VCD may be active in the
locomotive.
4) Don‘t try to reset VCD within 32 sec after application of penalty brake.

Trouble shooting
1. In case of auto regression of GR on 1st notch - check relay QVCD-
If energized – Reset VCD as per procedure.
If unsuccessful- try with putting HBA on ‗0‘ and again on ‗1‘
If unsuccessful- wedge QVCD in de-energized condition and isolate VCD by keeping HVCD
on ‗0‘.
2. BP Pressure is not building up after resetting VCD
Check IP valve for any air leakage and found, Isolate IP valve C.O.C and Open after BP
is recreated.
If unsuccessful- Isolate IP valve C.O.C and isolate VCD by putting HVCD on‘ 0‘
Note: QTW-6 relay is provided in place of QVCD in some locos.

C2 N feed valve in place of D24B feed valve (feed pipe) with incoming isolating cock &
out going isolating cock is provided in some locos.

Location – Pneumatic panel.

NB : Both the Incoming & out going isolating cocks shall be isolated in case metallic feed pipe
broken due to cattle run over and work with single pipe and Dead loco.

Page 7 of 105
Instruction About Auto Flasher Light :

Modification of switch ‗ON‘ Auto Flasher Light, LED & Audio indication automatically during
train parting/ACP is just an aid to Loco Pilot.

This modification does not alter duties/responsibility of the Loco Pilot as mentioned in GR&SR.

1. Press push button switch ―BPSW‖ provided in each cab for initial charging of BP after EOT
& for quick release of train brakes when applied A9.
BPSW is to be released after BP reaches 5 Kg/cm2.
2. The modification functions only when Reverser key ―MPJ‖ is operated in ―F‖ or ―R‖
direction.
3. To test this modification, press test switches ―TS‖ provided in Cab2 and observe Auto
Flasher Light working, Buzzer sounding, LED indication and auto regression of GR. It
works till it is kept in pressed condition.
4. In case of train parting/ partial uncoupling of BP pipe / during ACP / application RS1/RS2,
Loco Pilot gets Auto Flasher Light with buzzer & LED indication and auto regression of GR.
Loco Pilot should immediately find out the cause of abnormality and act as given in GR and
SR
5. Press reset switch SW to stop flasher light working & buzzer sounding after checking and
ensuring for any abnormality as per GR & SR, LED indication continues to glow till BP
recharges to 4.8 Kg/Cm2.
6. If resetting of only buzzer is required but wants to continue the glowing of flasher light then
LP must manually switch ‗ON‘ Flasher Light before pressing reset switch SW.
7. In any emergency, if auto Flasher Light is not working, put ‗ON‘ flasher light manually.
8. In MU operation during cab changing from one to another loco the following sequence of
operation should be carried out by the Loco Pilot to release the air pressure of P1 pipeline
between MU2B & A9 valve of trailing loco.
o MU2B to be operated to ―Trail‖ position & isolate the L/T cock.
o Apply A9 valve up to full service then isolate the inlet & outlet cut out cock so as to
release BP pressure.
Release A9 and proceed to other loco and energize as per normal
procedure.
In case of malfunctioning of Auto Flasher Light, or if TLTE is experienced, remove
CCLSA fuse and resume traction, work the train. Inform TLC, and
make an entry in the loco logbook.
9. Loco Pilot should not disturb setting of pressure switches/ A9 after the Sheds have set it.
10. Whenever a goods train is controlled by A-9 and while recreating BP, if it takes more than
1minute to come BP pressure up to 4.7 kg/cm2 due to excess leakage on train. This may
be cause for glowing of Auto flasher light. In this case LP is advised to release A9 gradually
/press SW as per condition.
NB :- NEVER USE TEST SWITCH “TS” WHILE TRAIN IS ON RUN

Page 8 of 105
Tri-plate Pneumatic Panel (Stone India)

Page 9 of 105
Tri-plate Pneumatic Panel (Faively)

STONE INDIA

Page 10 of 105
KNORR -BREMSE

FAIVELEY TRANSPORT

Page 11 of 105
TROUBLE SHOOTING DIRECTORY

FOR WAG5, WAG7, WAM4(6P), WAP4 CLASS LOCOS

Contents Page Number

1. CHAPTER ONE

Tripping Failure 15

2. CHAPTER TWO

Traction failure 38

3. CHAPTER THREE

Miscellaneous failures 49

4. CHAPTER FOUR

Microprocessor, STC, Air Dryer, Parts of OHE, 66


Pantographs, MU Loco Instructions.

Page 12 of 105
CHAPTER – I
TRIPPING FAILURE
CHECKING OPERATION IN CASE OF TRIPPING FAILURE

Preparation-1
Tripping on line, Bring MP to ‗0‘, wait 15 second for LSGR to glow, If LSGR does not glow
then bring GR to 0 manually., If LSGR glow then check panto and OHE. If any abnormality
found then lower panto, stop the train, comply with GR 6.03, contact LC/TPC. If no
abnormality found on OHE & panto, then check relay targets by physically operating reset
button of each relay, If relay target show red/locked indication refer the page number as
follows.

Srl. No. Abnormal Sign. Page No.

1(i) QLM alone dropped with ―LOCKED‖ indication 16

(ii) QLM dropped with QRSI-I/QRSI-2/QOP-1/QOP-2 16

2 QLA dropped 17

3 QOA dropped 17

4 QOP-1 or QOP-2 alone dropped 19

5 QRSI-1 or QRSI-2 alone dropped 19

Note: Check relay target physically after every tripping.

Page 13 of 105
If no relay target dropped, to pick up abnormal sign do as
given below:-
Preparation-2

Ensure MP on ‗0‘, & LSGR glows and RS pressure in between 8-10 Kg/Cm². Open all top
row BL switches except BLCP ‗A‘, Close BLDJ, Press BLRDJ and observe LSDJ, UA
needle & LSCHBA to pick up the abnormal signs as follows:-

SL Abnormal Sign. Loco defect Page No.


.No.

LSDJ remains glowing. Try with ADL 22


1 BLRDJ and BP2DJ. IF still then LSDJ ICDJ
remains glowing it is ICDJ.

LSDJ goes out but UA needle does not 26


2 No tension on line
deviate & LSDJ glows again.

LSDJ goes out but UA needle deviates, but 27


3 LSDJ glows again before LSCHBA goes OPERATION-A
out.

LSDJ & LSCHBA goes out, but LSDJ 28


4 comes again within 15 seconds after OPERATION-B
LSCHBA goes out.

LSDJ & LSCHBA goes out and remains 30


extinguished, Build up MR pressure to 8
5 OPERATION-O
Kg/Cm². Close BLVMT, if DJ trips within 15
seconds after closing BLVMT.

Take one traction notch, DJ trips within 15 33


6 OPERATION-I
seconds.

LSDJ glows within 15 seconds after taking 35


6 traction notches ( Follow as per the case
below)
While standing: Open DJ, Put both HVSI
7 switch on ‗0‘ close DJ take 6 traction OPERATION-II
notches and wait for 15 seconds, If LSDJ
glows:-
While on Run: Take six traction notches
and wait for 15 seconds, If LSDJ glows:-

DJ trips repeatedly on different occasions 37


8 TWAC
other than the above tripping operations.
Page 14 of 105
TROUBLE SHOOTING OF RED TARGET DROPPED RELAYS

Probable defects/ Action to be taken by the Loco Pilot


observation/checking
1.i IF QLM HAS TRIPPED DO NOT RESET RELAY TARGET.
ALONE Check the feeding power circuit for any abnormalities
like signs of oil spillage/splashing near tap
changer/transformer, their oil levels, GR safety
valve blowing off, CGR contactors, proper
fitment of arc chutes, roof bushing/insulator,
smoke, burning smell, over heating of
equipment, fire, etc. in HT Compartment and
Machine Room. If any abnormality noticed, take
proper safety measure
If possible, clear block section with good loco in
MU/Consist
QLM ALONG WITH QRSI- i) Note down the ammeter reading. Check as
1.ii 1 & QRSI-2. per above item-1 along with corresponding
OR circuit. If no abnormality noticed:
QLM ALONG WITH QRSI- Reset the relay indicators-Resume traction.
1/ QRSI-2 & QOP1/ QOP2. If DJ trips again – through the same relay/
OR relays.
QRSI-1/ QRSI-2 Put HMCS on position II, III & IV one by one.
ALONG WITH QOP1/QOP2 Resume traction.
Observe the above relays dropping.
Put HMCS in that position where no tripping
occurs.
Where tripping does not occur, Reset relay
target.
Close DJ/VCB, Resume traction.
ii) If tripping again takes place in all
position of HMCS:
Put back HMCS on position-1.
Put HQOP-1/HQOP-2 in ‗off‘ position.
Resume traction.
iii) If tripping takes place again:
Reset the relay target.
Once again try with HMCS on different
Position‘s one by one.
Observe the target of above relays.
Keep HMCS in that position where tripping
does not take place. Resume traction.
Observe for any smoke emission on run.
iv) If tripping takes place again in all
positions of HMCS.
Isolate corresponding RSI block. (Rectifier
Block ).
If MVMT-1 is isolated, wedge C 106.(if required)
Manually operate Q118.
If load permits – Resume traction, in

Page 15 of 105
Probable defects/
observation/checking Action to be taken by the Loco Pilot
2. IF QLA HAS DROPPED Check for smoke emission from auxiliary motors,
contactor panel, switch board, Q30,UA,ARNO,
R118 and C-118/S-118.
If no abnormality- Reset the relay target.
Close DJ. Resume traction.
If DJ trips again through QLA.
Check for smoke emission.
If no smoke emission- reset the relay target, close
DJ and resume traction.
If there is smoke emission, isolate the
corresponding equipment and work as per standard
instruction.
3. QOA DROPPED Check for smoke emission from Auxiliary motors,
contactor panel, switch board,Q30,UA, ARNO,
R118, C118/S-118, etc. Ensure all contactors are
open.
If no abnormality do the following.
A. I. If QOA target reset Reset the relay target. Close DJ and Resume
traction.
II. If DJ trips again OpenBLRA-1/BLRA-2,remove CCRA-1,CCRA-
through QOA 2,CCVT & CCSPM. Reset the relay target. Close
DJ and resume traction. Inform LC at the first
opportunity and enter in log book.
III. If DJ trips again Put HVSI-1 & 2, HVSL-1 & 2, HPH, HCHBA on ‗O‘
through QOA. and BLCP, and BLVMT ―OFF‖. Reset relay target.
Close DJ.
If DJ trips again through QOA, Put HQOA on
―O‖, Reset relay target. Close DJ – resume
traction.
Observe for any smoke emission on run and work
as per step ‗C‘.
If DJ holds, put back HVSI-1 & 2, HVSL-1&2,
HCHBA and HPH on position ‗I‘ one by one. If DJ
trips after putting any switch on position-1, isolate
that auxiliary and work the train as per standard
instruction.

IV. If QOA drops for If QOA drops through MPH or MVSI-1 or 2 or


MPH/MVSI-1or MVSL-1 or 2, then isolate the defective motor and
2/MVSL-1 or 2/CHBA work as per step ‗C‘. If CHBA defective Refer Page
No: 59..
V. If QOA drops on Put BLCP,& BLVMT ‗ON‘ one by one. If QOA
Closing BLCP/ drops on closing BLCP change the position of HCP
BLVMT. and isolate the defective motor .
If QOA drops on closing BLVMT – put MVMT-1,
MVMT-2 & MVRH in service one by one. Isolate
the defective motor and work as per step C

Page 16 of 105
Probable defects/
observation/checking Action to be taken by the Loco Pilot
B. If DJ trips through QOA Put HOBA on ―OFF‖ position. Reset relay target.
with HQOA on ―O‖, Close DJ – resume traction.
Observe for any smoke emission on run.

C. If smoke emission from Extinguish fire using Fire extinguisher.


auxiliary motor, contactor Follow the instruction given below for isolation
panel, ARNO & R-118 etc. of Auxiliary motor/motors.
If smoke emission from MPH Put HPH on ‗O‘. Ensure MVRH is working.
Continue Traction not exceed the following current
ratings:
920 Amps for 10 minutes
500 Amps continuous.
If smoke emission from MVRH Put HVRH on ‗O and put HC-105 on O (if provided)
otherwise Wedge Q118. Clear block section.
Maintain the following current ratings:
Starting: 920 amps for 10 minutes.
Continuous: 500 amps.
If smoke emission from MVSI- Isolate corresponding RSI block.
1/MVSI-2 or MVMT-1/MVMT-2 Put HVSI-1/HVSI-2, HVSL1/HVSL-2 and HVMT-
1/HVMT-2 on ‗O .‘If load permits – continue traction.
If the load does not permit- contact LC.
If smoke emission from Put respective HVSL1/HVSL2 on ―0‖.Clear block
MVSL1/MVSL2 section with 500AMPs..After arrival at station isolate
corresponding block..If load permits resume traction.
If the load does not permit- Contact LC.
If QOA target is unable to reset Put HBA in ‗off‘ position. Reset relay target and
(permanent QOA). put HBA ‗ON‘.
If target drops when HBA put ‗ON‘ then open
BLRA-1&2, remove CCRA-1&2, CCVT CCSPM.
Reset relay target. Close DJ – resume traction.
If unable to reset, Put HVSI-1 & 2, HVSL-1 & 2,
HPH, HCHBA on ‗O‘ and BLCP, and BLVMT
―OFF‖ one by one. Reset relay target. Close DJ –
resume traction after isolating faulty one.
If still unable to reset, kept all above switches
normal and HQOA on ‗0‘- Reset QOA and
resume traction.
If relay target is still unable to reset- Put HOBA in
‗off‘ position in all locos and resume traction.
If relay indicator is still unable to reset- clear the
section by good loco in MU/Consist, if load permits
and inform LC.
If SU/ load does not permit- contact LC/SM/SCR
and request for assistance.
NOTE: 1) For SIV Loco Refer trouble shooting for EXTERNAL FAULT lamp glow.
2) AFTER ISOLATING ANY AUXILIARY MOTORS, ENSURE THE CORRESPONDING
CONTACTOR IN OPEN CONDITION AND ENTER IN THE LOCO LOG BOOK,

Page 17 of 105
Probable defects/
observation/checking Action to be taken by the Loco Pilot
4.
QOP-1 OR QOP-2 ALONE ,Check for smoke emission from TMs, Reversers, CTFs,
HAS TRIPPED RSI block, line contactors, shunting contactors, SLs, etc.
If there is smoke emission- Use fire extinguisher to
extinguish fire.
Isolate the equipment- Resume traction.
If there is no smoke emission-
Reset the relay – Resume traction.
i. If DJ trips again through the
same relay.
Put the corresponding HMCS on position II, III, IV, one
by one. Reset the relay- Resume traction.
Observe QOP dropping.
Keep HMCS in that position, where QOP is not
dropping. Resume traction.
ii. If QOP-1/QOP-2 drops in all
positions of HMCS.
Put corresponding HQOP in ‗OFF‘ position.
Put back HMCS on position 1 – Resume traction.
Observe for any smoke emission on run.
If QOP-1/QOP-2 drops again –
Put HOBA in ‗OFF‘ position – Resume traction.
Observe for any smoke emission on run.
a. IF RELAY INDICATOR CANNOT BE RESET.
.i. Put HBA in ‗off‘ position. Reset relay target
and put HBA ‗ON‘.
ii. If target drops when put HBA ‗ON ‘try with isolating
TM‘s one after another.
Iii .If not success Put HQOP-1/HQOP-2 in ‗OFF‘ Reset
the relay target- Resume traction.
Observe for any smoke emission on run.
iv. If still unable to reset the relay:
Put HOBA in ―OFF‖ position.
Reset the relay target – Resume traction.
Observe for any smoke emission on run.
v. If still unsuccessful (after putting HOBA in OFF )
Isolate corresponding block. Resume Traction.
If unsuccessful, ask for relief Loco.
5. QRSI1/QRSI-2 ALONE HAS a. Reset the relay indicator.
TRIPPED Note down the Ammeter reading
Resume traction at lower notches (less TM current).
b. If unsuccessful:
Isolate any one Traction Motor corresponding to
QRSI dropped.
Resume traction.
c. If unsuccessful again
Isolate corresponding RSI (Rectifier) block.
Put HVSI-1/HVSI-2, HVSL1/HVSL-2 and HVMT-
1/HVMT-2 on ‗O‘.
If load permits – Resume traction and inform LC.
If unsuccess ask for relief loco.
CAUTION--DO NOT PUT HQOP/HOBA IN “OFF” POSITION UNLESS TRACTION
MOTOR-ISOLATION IS TRIED THROUGH OPERATION OF HMCS

Page 18 of 105
Page 19 of 105
ICDJ
LSDJ REMAINS GLOWING

[Re- Check Relay Target, if dropped follow trouble shooting of safety


Relay dropping]
Remark – 1 for SU
Remark – 2 for MU/Consist.

REMARK - I
Probable defects/
observation/checking Action to be taken by the Loco Pilot
Ensure BLDJ is closed, LSGR glowing and ZPT is in other than ‗O‘ position.
1. IF LSGR EXTINGUISHED Bring GR to ―O‖ manually. Close DJ after
ensuring LSGR is glowing.
2. IF LSGR GLOWING a. Check C-118/S-118 for closing/not
closing by following the method given below.
b. Stand near C-118/S-118. Ask the Asst. Loco
Pilot to close BLDJ and press
BLRDJ./BP2DJ Listen to the closing sound
of C-118/S-118.
3. IF C-118/S-118 CLOSING If closing sound is heard-
Ensure RS pressure is above 8 kg/ cm².
IF RS PRESSURE IS LESS Ensure air control cut out is open, RDJ drain
THAN 8 KG/CM² cock closed.
Then build up RS pressure through CPA up to
8kg/cm².
IF RS PRESSURE IS Drain out full RS pressure and close DJ after re-
EXCESS building RS to 8 kg/ cm².
a. Check DJ / VCB for any air leakage.
b. VCB pressure regulating gauge is showing
more than 5.2 kg/ cm², if visible.
4. IF C-118/S-118 IS NOT Check BA Voltage.
CLOSING-

IF BA VOLTAGE LESS OR Operate HBA switch few times. [One 35 amps


NIL fuse/MCB is provided in BA Box-1, as
additional CCBA. [If any time, Loco Pilot
experienced BA voltage ―Zero‖, he should
positively change this fuse/ Reset MCB].

IF BA VOLTAGE IS > 80 V. Check relay Q-118


5. IF Q-118 NOT ENERGISED Check CCBA, CCPT, one by one. Ensure the
opening of C-105,C-106 & C-107&C118/S118.
Page 20 of 105
Probable defects/ Action to be taken by the
observation/checking Loco Pilot
A. IF CCBA & CCPT a. Renew the melted fuse. Close DJ
. melted.
b. If unsuccessful – check the fuse and fuse
carrier again.
c. If fuse melts again- put HOBA in ―OFF‖
position [in all the locos of MU/Consist].
Renew the fuse, clean the fuse carrier base
and resume traction.
d. If fuse melts again- request for assistance.
B. If CCBA & CCPT a. Close BLDJ & BLVMT, close Q-118
NORMAL manually. Close DJ by BLRDJ/BP2DJ.
Release Q118 after all the blowers start or
after one minute and resume traction.
If unsuccessful – Take safety measures.
b. Ensure C-118 is open.
Wedge Q-118 and close DJ.
Resume traction – clear block section.
Observe the working of all auxiliaries.
On arrival at station – Take safety
measures.
Remove the wedge of Q-118. Put HVMT-1
& 2, HVSL- 1&2, HPH, HVRH on ‗III‘ and
HQCVAR on ―O‖ after operating few times.
i. If Q-118 is energized : Put back all the
above switches in position-1 one by one.
Observe Q-118.
If Q-118 gets de-energized: Put back that
switch on position-III.(HQCVAR on ‗0‘)
Resume traction. Observe the working of
auxiliary whose switch is kept on position-
III. (Relay isolated).
In case HPH is kept on position ‗III‘ –
Continue traction. Observing the following
current rating:-
Starting – 920 Amps for 10 minutes.
Continuous – 500 Amps.
ii. If Q118 is still de-energized-request for
assistance and inform LC.

Close BLDJ, PRESS BLRDJ/BP2DJ


IF Q-118 IS ENERGISED.
OBSERVE Q-45 & Q-44

Page 21 of 105
Probable defects/ Action to be taken by the
observation/checking Loco Pilot
6. IF Q-45 ALONE NOT a. Check CCDJ-
ENERGISED
i)-If CCDJ found melted – - Renew the same. If melts again put HOBA
‗off‘ and renew the fuse. If CCDJ melts after
putting HOBA ‗off‘ request for assistance.
ii)- If CCDJ found good - Change the position of ZPT. Ensure GR on
‗O‘.
Operate GR manually from ‗O‘ to ‗1‘ and
back to ‗O‘ for few times.
Close BLDJ, press BLRDJ/BP2DJ - Close
DJ.
b. If still Q- 45 not energized –
Operate Q-45 manually, (after ensuring GR
on ‗O‘). Release Q45 after LSCHBA goes
out. Resume traction.
Every time for closing DJ, Operate Q45
manually.
c. If DJ does not close – Don‘t release Q45.
Check Q-44.
If Q-44 is energized -Try from other cab.
If DJ closed – Resume traction.
Clear the block section, observing the GR &
SR in force.
If unsuccessful – Request for assistance.
7. IF Q-44 ALONE NOT Operate GR manually from ‗O‘ to ‗1‘ and
ENERGISED back to ‗O‘ for few times.
Close DJ– Resume traction.
If unsuccessful – Close both Q-45 &Q-44
manually. Release Q-44 & Q-45 after
LSCHBA goes out.
Resume traction.
If unsuccessful – Request for assistance.

8. IF DJ CLOSES ON MANUAL Never wedge relay Q44.


OPERATION OF Q-44 AND DJ Ask for assistance/Relief loco.
OPENS ON RELEASING Q-44
9 If Q-44 is energized but Take safety measure. Operate C-118/
C-118/S-118 is not closing S-118 manually few times. Close DJ.
If Unsuccessful- Request for Assistance.

Page 22 of 105
REMARK – II
[FOR REAR LOCO IN MU / CONSIST]

In case of ICDJ in leading loco refer Remark-I


On pressing BLRDJ on leading loco, LSDJ remains glowing but UA deviates and
LSGRPT goes out, LSOL remains glowing.

ICDJ on trailing/rear loco in i. If the load permits – Clear the block section by
MU/Consist. leading loco.

ii .a On leading loco- Ensure BLSN is in normal/Up


position.
Operate BLSN few times. Ensure PT raised on
trailing loco.
Close DJ. Resume traction.

b. If unsuccessful – Tap gently on the BL board


near BLSN switch.
Close DJ- Resume traction.

c. If unsuccessful again – while going to trailing


loco. (In which LSGRPT remains glowing)
Keep leading loco in energized condition, with
BLVMT closed.
Ensure proper fitness of the MU jumpers
connected between locos.
On trailing loco press BP2DJ. Close DJ.

IF DJ CLOSED Come back to leading loco – Resume traction.

IF DJ DOES NOT CLOSE Trouble shoot on trailing loco as per Remark-I.


[Page- 19 ]
Use BP2DJ in place of BLRDJ in trailing locos.

IMPORTANT INSTRUCTIONS
a. WEDGING OF Q-118 NOT PERMITTED IN TRAILING LOCO.
If it is necessary to wedge Q -118 on rear loco, follow standard instructions .
b. WEDGING OF Q-118 ON LEADING LOCO IS PERMITTED TO CLEAR BLOCK
SECTION ONLY.
c. WEDGING OF Q-44 IS STRICTLY PROHIBITED.
d. WHEN EVER EXPERIENCE ICDJ MR & RS PRESSURE (SHOWING IN GAUGE)
SHOULD BE CHECKED AND MENTIONED IN THE LOG BOOK.

Page 23 of 105
NOTENSION ONLINE
LSDJ GOES OUT BUT UA FAILS TO DEVIATE AND LSDJ COMES AGAIN

Probable defects/ Action to be taken by the Loco Pilot


observation/checking

1. CLOSE BLDJ, PRESS - While on run check OHE, PANTO, TRACK


BLRDJ, IF UA DOES NOT AND TRAIN in front and in rear.
DEVIATE, RELEASE - If any abnormally noticed – lower panto.
BLRDJ AFTER LSDJ Stop the train, comply with GR 6.03 –
GLOWS AGAIN Contact LC/TPC.
If no abnormality is noticed:
Ensure RS pressure is 8.0 to 10.0
kg/sq.cm.
Close DJ once in every minute for three
times.
Don‘t Release BLRDJ till DJ trips.
If tension restores – Continue traction.
If still tension not restored:
Put other panto into service.
If successful – Resume traction.
- Informed LC at first opportunity
- If unsuccessful with other panto.
- Stop the train near an emergency socket.
Lower the panto and Check loco roof from
ground level. Look for any abnormality and
foreign body.
- Contact LC/TPC.

If unable to contact - Raise panto once in every three minutes for


three times.
- If tension not restored – Lower panto. Ask
for assistance. Observe SR 6.04.02(d)
- If tension restored after 5 min. ,then
Obverse SR 17.09.01 (5) (ii),(iii),(iv)
IMPORTANT INSTRUCTIONS

a. If OHE damaged – lower the panto immediately. Stop the train and protect as
per GR 6.03. Contact TPC.

b. If panto is damaged – stop the train. Comply with GR 6.03 and follow
instructions on page No.56.

Page 24 of 105
OPERATION ‗A‘

LSDJ GOES OUT, UA DEVIATE AND LSDJ GLOWS AGAIN BEFORE


LSCHBA GOES OUT
Remark – 1 for SU
Remark – 2 for MU/CONSIST.
REMARK – I

Probable defects/
observation/checking Action to be taken by the Loco Pilot

CHECK QCVAR Close DJ. Observe QCVAR.

IF QCVAR REMAINS DE- Put HQCVAR on ‗O‘ Close BLDJ.


ENERGISED Press BLRDJ and release it after 3 to 5
seconds.(LSCHBA remains glowing)
Resume traction.
Observe for any abnormal sound/smoke
emission from ARNO.
Frequently check for working of CHBA. If CHBA
is not working, Refer MISC FAILURE.

REMARK - II

Trouble shoot as per Remark-1 for leading loco.


Ensure from leading loco:
Panto of trailing loco is touching the contact wire.
Proceed to the trailing loco.
Do the same operation on trailing loco as given under Remark-I for SU or leading
loco in MU/Consist.
Observe for any abnormal sound/smoke emission from ARNO.

NOTE

IF LSDJ FLICKERS:

1. CHECK RELAY TARGETS BY MANUAL OPERATION, IF ANY RELAY TARGET


DROPPED- TROUBLE SHOOT FOR SAFETY RELAY DROPPING.
2. CHECK VCB PRESSURE REGULATOR (ABOVE 5.2 kg/cm²), IF VISIBLE. IF NO
ABNORMALITY NOTICED – ASK FOR RELIEF LOCO.

Page 25 of 105
OPERATION – ‗B‘

LSDJ GOES OUT, UA DEVIATES & LSCHBA GOES OUT, BUT LSDJ GLOWS
AGAIN WITHIN 15 SECONDS AFTER LSCHBA GOES OUT
Remark – 1 for SU
Remark – 2 for MU/CONSIST.

REMARK- I

Probable defects/
observation/checking Action to be taken by the Loco
Pilot
RECORD OHE VOLTAGE, SECTION AND Put HQCVAR on ‗O‘, HPH,
TIME. IF OHE VOLTAGE LESS THAN 19 KV HVSL-1 and HVSL-2 on position
CONTACT WITH TLC/TPC/SCR AND WAIT III – after operating the switches
TILL NORMALISATION OF OHE. .IF OHE a few times.
ABOVE 19 KV THEN DO AS -> Close DJ- Wait for 15 seconds.
1. IF DJ HOLDS Observe the working of both
MVSL-1 & MVSL-2.
A. IF BOTH MVSL-1 & 2 ARE WORKING. Clear block section.
On arrival at next station – Trip
DJ.
Put back HQCVAR, HPH, HVSL-
1 & HVSL-2 to position-1, one by
one.
Each time after closing DJ – Wait
for 15 seconds.
If DJ trips after putting any
switch on position-1:
Put that switch on position-III (for
HQCVAR, put on ‗O‘).
If DJ holds:
Resume traction.
Observe the working of MVSL-1
& 2 frequently.
On keeping HPH on III, observe
for abnormal rise in TFP oil level
and inform LC immediately.
Check for any oil leakage from
transformer.
Continue traction – Observe
following current ratings.
Starting – 920 amps – 10
minutes.
Continuous – 500 amps.
Inform LC.

Page 26 of 105
Probable defects/
observation/checking Action to be taken by the Loco Pilot
B. IF MVSL-1 OR MVSL-2 OR BOTH Isolate the defective blower – Clear
ARE NOT WORKING. block section.
Do not exceed the current ratings of 500
amps.
On arrival at next station:
If both MVSL-1 & 2 are not working,
Request for assistance/Relief loco.
If either MVSL1 or 2 only not
working.
Isolate the corresponding block.
Put corresponding HVSL, HVMT & HVSI
on ‗O‘
If load permits – Inform LC and continue
traction.
If load does not permit – Contact LC.
2. IF DJ TRIPS Put back HPH, HQCVAR, HVSL-1 &
HVSL-2 on position-1.
Wedge Q118 – Close DJ. Clear block
section.
Ensure the working of all auxiliaries.
Observe for any smoke emission from
auxiliaries.
On arrival at the station – contact LC.
ON WEDGING Q 118 If unsuccessful
Remove Wedge from Q118.
Ask for assistance/Relief loco

REMARK- II
Trouble shoots as per Remark-I for leading loco.
Proceed to the trailing loco.
Trouble shoot as given under Remark-I for SU and on leading loco in MU/CONSIST.

NOTE:

1. Wedging of Q118 is not permitted on trailing loco while driving from leading loco.
2. If HPH put on ‗O‘ – Follow the Standard instructions on Page No.-(iii) item – 7
3. While closing DJ if LSDJ & LSCHBA extinguishes but LSDJ glows immediately
after releasing of BLRDJ – defects in Q-30. Observe Q-30 for any smoke
emission.
4. During the course of trouble shooting, if it is required to wedge Q118 on rear
loco – Proceed to rear loco and wedge Q118 on rear loco. Clear block section
only driving from rear loco observing working of all auxiliaries following GR &
SR 4.21 in force.

Page 27 of 105
OPERATION-‗O‘

HVMT-1
0,3

Page 28 of 105
OPERATION ‗O‘
LSDJ GlOWS AGAIN WITHIN 15 SECONDS AFTER CLOSING BLVMT.

Remark – 1 for SU, Remark – 2 for MU/CONSIST.

REMARK- I

Probable defects/
observation/checking Action to be taken by the Loco Pilot
Keep BLVMT switch in closed position. Put HVRH, HVMT-1 & 2 on position-III,
Close DJ, wait for 15 secs.
1. IF DJ TRIPS Put the above switches on position-1.
Wedge Q118.
Close DJ, close BLVMT and Observe the
working of blowers of MVRH, MVMT-1 & 2.
Clear block section.
2. IF DJ HOLDS Check the working of Blowers

A. IF ALL THE BLOWERS Clear the block section


ARE WORKING. Observe working of all blowers on run.

On arrival at station,
Put back the above switches one by one on
position-I. Close DJ. Close BLVMT.
If DJ trips on putting any switch on position-1:
Maintain that switch on position-III.
Put all other switches on position-I.
Resume traction –
Observe the working of the blower, whose relay
is isolated.

B. IF ONE OR MORE Isolate the defective blower motor and


BLOWERS DO NOT follow the instructions given below:
WORK.
I. LOCOS PROVIDED i. If MVRH not working –
WITH HC105. Put HVRH on ‗O‘ and HC105 on ‗O‘.
Clear block section observing following
current rating
Starting: 920 Amps for 10 minutes
Continuous: 500 Amps.
On arrival at station – Request for assistance.
ii. If MVMT1 or MVMT2 is not working-
Put HC105 on ‗O‘.
Put corresponding HVMT-1 or 2, HVSL-1 or 2
& HVSI-1 or 2 on ‗O‘.
If load permits – Resume traction and inform
LC.
If load does not permit – Contact LC/SM/SCR
for assistance loco.
Page 29 of 105
II. LOCOS NOT i. If MVRH not working.
PROVIDED WITH Clear block section.
HC105. Put HVRH on ‗O‘, wedge Q118, close DJ.
Follow current rating (starting 920 Amps for
10 minutes and continuous 500 Amps).
On arrival at station – Request for assistance.
ii. If MVMT-1 or MVMT -2 not working.
Put corresponding HVMT-1 or 2, HVSL-1 or 2
& HVSI-1 or 2 on ‗O‘.
If load permits – Resume traction.
If load does not permit – Contact LC.
REMARK- II
Trouble shoot as the Remark- I for leading loco.
Proceed to the trailing loco.
Do the same operation as given under Remark- I for SU/leading loco.

NOTE:
1. Wedging of Q118 Is Not Permitted On Trailing Locos While Driving From
Leading Loco.
2. During the course of trouble shooting, if it is required to wedge Q118 on rear
loco – Proceed to rear loco and wedge Q118 on rear loco. Clear block section
only driving from rear loco observing working of all auxiliaries following GR&SR.
3. There is no provision to wedge Q118 in Microprocessor loco (except MPCS
version -3), clear block section with 5 notches.
OPERATION-‗1‘

HVSI-1
0,3

HVSI-2
0,3

Page 30 of 105
OPERATION –I
LSDJ GLOWS AGAIN WITHIN 15 SECONDS AFTER TAKING ONE TRACTION
NOTCH
Remark – 1 for SU
Remark – 2 for MU/CONSIST.
REMARK- 1

Probable defects/
observation/checking Action to be taken by the Loco Pilot
Put HVSI-I & II on position-III, Close DJ, Take one traction notch and wait for 15
secs.
1. IF DJ HOLDS Check the working of MVSI-1 & 2
i. If MVSI-1 & 2 are working:
Clear the block section.
a. On arrival at station –
Open DJ, Put back HVSI-1 & 2 one by one on
position-I, Close DJ.
Take one traction notch and wait for 15 seconds.
If DJ trips:
Put that HVSI switch on position III.
Put the other HVSI on position-I. Resume traction.
Observe the working of blower whose relay is
isolated.
2. IF DJ TRIPS i. Put the HVSI-1 & 2 on position ‗I‘.
AGAIN - Check SMGR reducing valve and ensure the
pressure 3.0 to 3.5 kg/cm², resume traction.
If unsuccessful, operate GR manually few times
Resume traction if unsuccessful, operate BL few
times on both cabs.
ii. If unsuccessful.
Isolate the RSI blocks one by one.
If load permits – Resume traction.
iii. If Unsuccessful – Clear Block Section by Manual
Control of GR.
3. IF MVSI-1 OR Isolate the corresponding block.
MVSI-2 IS NOT Put the corresponding HVSI-1 or 2, HVSL-1 or 2 and
WORKING HVMT-1 or 2 on ―O‖ If load permits – Resume traction.
If the load does not permit – Contact LC.

REMARK- II

Trouble shoot as per Remark-1 for leading Loco. Check proper fitment of MU
Jumpers & proceed to trailing loco.
Do the same operation on trailing loco.In MU CONSIST-Follow the instructions as
given under Remark-1 for SU/Leading Loco.

Page 31 of 105
OPERATION – II

HVMT-1
(0,3)

HVMT-2
(0,3)

Page 32 of 105
OPERATION –II
LSDJ GLOWS AGAIN WITHIN 15 SECONDS AFTER TAKING SIX TRACTION NOTCHES
Remark – 1 for SU
Remark – 2 for MU/CONSIST. .

REMARK- I

Probable defects/
observation/checking Action to be taken by the Loco Pilot
Ensure HVRH, HVMT-1 & 2 on position-I, Close DJ, Close BLVMT, Check the
working of blowers.
1. IF ALL THE a.i. On locos provided with HC 105
BLOWERS ARE Put HC 105 on ‗O‘ –close DJ do test for OP-II.If DJ
WORKING holds Resume traction
Observing the working of blowers on run.
ii. On locos not provided with HC 105
Put HVMT-1 & 2 on position-III. Close DJ, test for
OP-II. If DJ holds
Resume traction and observing the working of
blowers on run.
b. If unsuccessful.(DJ NOT HOLD)
Put back all switches in position-I.
Wedge Q118. Clear block section.
Observing the working of auxiliaries.
c. On arrival at station:
Take safety measure.
Remove the wedge from Q118.
Operate manually – C107, C106 and C105
Resume traction.
If unsuccessful.
Take safety measures – Wedge C107.
Put HVRH on III/Operate Q118 manually. Close DJ-
Resume traction.
If again unsuccessful – Request for assistance.
2. IF ALL THE a. Close BLCPD. Check the working of compressors.
BLOWERS ARE i. If the compressors are working:
NOT WORKING. Take safety measures.
Wedge C107, C106 and C105 manually operated
Q 118. Close DJ. Resume traction.
ii. If the compressors are not working – Refer
Troubleshooting of ALL AUIXILIARY NOT
WORKING.
3. IF ONE/MORE I Take safety measure. Wedge the corresponding
BLOWERS ARE contactor. Put corresponding switches on position –
NOT WORKING. III/manually close Q-118. Close DJ. Resume
traction.

Page 33 of 105
REMARK – II
Trouble shoots as per Remark-I for leading loco.
Proceed to the trailing loco.
Do the same operation on trailing loco as given under Remark-I for SU/leading
loco.
During the course of trouble shooting:
When one or more blower contactors are wedged.
Put HVMT1, HVMT2 and HVRH on position III.
Check Q118.

i. If Q118 is energized.
Come back to leading loco – Resume traction.

ii. If Q118 is not energized.


Put back HVMT1, HVMT2 and HVRH on
position I.

Manually operate Q118 on trailing loco.


Close DJ with BP2DJ.

Resume traction. Clear block section.

On arrival at next station.

If the load does not permit-Request for assistance.


NOTE
1. Before putting HC105 on position ‗0‘, ensure all the blowers are working.
2. After putting HC105 on ‗O‘ check working of blowers every 15 minutes on run
3. On wedging contactors C105, C106 or C107, manually operate Q118/ Put HVMT
– 1, HVMT – 2, & HVRH on III. Close DJ. (on STC loco manual closing of Q 118
not required)
4. Wedging Of Q118 Is Not Permitted On Trailing Locos While Driving From
Leading Loco.
5. During the course of trouble shooting, if it is required to wedge Q118 on rear loco
– Proceed to rear loco and wedge Q118 on rear loco. Clear block section only
driving from rear loco observing working of all auxiliaries following G&SR.
.
6. IN CASE OF SIV FITTED LOCO:
Ensure BLVMT is closed before closing DJ.
Resume traction.
If the compressors are not working –
Refer -Miscellaneous failures for auxiliaries not working).
Page 34 of 105
TWAC
TRIPPING WITHOUT ANY APPARENT CAUSE

IF THE TRIPPING OCCURS SPECIALLY ON HIGHER NOTCHES, CHECK THE UA.


IF UA SHOWING – BELOW 19KV, CLEAR BLOCK SECTION ON LOWER NOTCHES
AND INFORM TLC/TPC AT THE NEXT STATION.

Probable defects/ Action to be taken by the Loco Pilot


observation/checking
1. IF NO TRIPPING Continue haul the train. Enter in the loco Log
Book and inform TLC.
2. IF TRIPPING OCCURS i. Ensure RS pressure above 8.0 Kg./cm²

ii Change the position of ZPT. Use EEC –


Resume traction
a) IF TRIPPING OCCURS Take safety measures.
3. AGAIN (TWAC) Operate the following switches two or three
times.
Put HQCVAR on ‗O‘, HVRH, HVMTI,
HVMT2, HVSL1, HVSL-2, HVSI-1 & HVS1-
2, HPH on position III & HC- 105 on ‗O‘.
b) IF TRIPPING OCCURS Check-SMGR Reducing valve pressure
DURING PROGRESSION (3.5kg/cm²),
OR REGRESSION OF GR. Operate GR manually few times.
Put back ZPT on ‗1‘ and resume traction
using MP.
Observe the working of all blowers.
4. IF NO TRIPPING OCCURS At next stoppage –
Put back the above switches in position - ‗1‘
one by one
Observe tripping.
If tripping occurs by putting any particular
switch on position ‗1‘ – Keep that switch on
position-III.
Put other switches on position ‗1‘. Resume
traction.
Ensure frequent checking of blower
Whose relay/relays have been isolated.
In case, if HPH is kept on III – Continue
traction.
Observing the following current ratings.
Starting – 920 amps for 10 minutes.
Continuous- 500 amps.

5. IF TRIPPING OCCURS AGAIN Put HQOP-1 & 2 in ‗OFF‘ position and


HQOA on ‗O‘.
Resume traction.

6. IF TRIPPING OCCURS AGAIN Put HOBA in off position

Page 35 of 105
Probable defects/ Action to be taken by the Loco Pilot
observation/checking
(On all locos in MU/Consist)- Resume
traction.

7. IF UNSUCCESSFUL Change the cab or loco. Clear the block


section. Observe instructions of SR,
4.21.01(b)(i).

8. IF UNSUCCESSFUL AGAIN: If tripping permits – continue haul the train.


If tripping does not permit – Stop the train
at the next station/emergency socket –
Inform LC. Enter in the loco log book.

NOTE:

1. ENSURE RS PRESSURE 8.0 KG/CM2 AFTER EVERY TRIPPING

2. OBSERVE IF LOCO TRIPS IN BETWEEN NOTCH 2 TO 5 OR AFTER NOTCH


6.

3. IN EVERY TRIPPING, OBSERVE OHE VOLTAGE AND MENTION IT IN THE


LOCO LOG BOOK. IF IT IS FOUND LOW/HIGH- CONTACT WITH TLC/TPC.

Page 36 of 105
( CHAPTER – II )

TRACTION FAILURE

A. TOTAL LOSS OF TRACTIVE EFFORT (TLTE) Page


1. Total loss of Tractive Effort or impossibility to start during
Traction. Ammeters do not deviate.
a. GR is not progressing at all. 42
b. GR is progressing 44

2. Total loss of Tractive Effort after using Rheostatic Braking. 45

B. REDUCTION/LOSS OF TRACTIVE EFFORT. Page


1. LSP glows on run without wheel slipping with both or one 46
ammeter deviating and GR comes to ‗O‘
2. Auto-Regression of GR without glowing of any lamp on lower 47
notches/1st notch.
3. Auto regression of GR without glowing of any lamp on higher 47
notches.
4. Smoke or Spark or abnormal noise from the Traction Motors. 48
5. GR does not progress beyond one/certain notch in SU/MU. 49
6. Connection of Ammeter – Voltmeter – QDs. 49
7. Connection of Ammeter – Voltmeters for locos with two 49
voltmeters and one ammeter in each cab. (Modified).

Page 37 of 105
Page 38 of 105
Page 39 of 105
TRACTION FAILURE

A. TOTAL LOSS OF TRACTIVE EFFORT


OR
IMPOSSIBILITY TO START DURING TRACTION, AMMETERS DO NOT DEVIATE

1. a ) GR IS NOT PROGRESSING AT ALL

Probable defect/
Observation/ Checking Action to be taken by the Loco Pilot
I. IF LSB GLOWS Take safety measures. Ensure the following.
[MPJ on ―F‖ OR ―R‖] i. J1 & J2 is in desired direction.
Driving Position of Direction of Direction of
cab MPJ J-1 J-2
Cab-1 Forward UP UP
Cab-1 Reverse DN DN
Cab-2 Forward DN DN
Cab-2 Reverse UP UP

ii. CTF-1, 2 & 3 are in ‗TR‘ (UP) Position.


iii. C-145 is in open condition.
If no abnormality is noticed-
Close DJ, Put MPJ in forward position.
If LSB Extinguished- Resume traction.
iv. If LSB still remains glowing:
Trip DJ, Take safety measures – Wedge Q50 in
energized condition and Resume traction.

N.B. i) If LSC-145 lamp is provided and it is glowing –


Do not wedge Q50. Follow item-III above.
ii) LSC – 145 glowing – C145 close condition
Extinguish – C145 open condition.

Page 40 of 105
II. IF LSB IS Check and ensure the following:
EXTINGUISHED 1) BP pressure to be 5 kg/sq.cm.
2) Observe Auto Flasher light, if flashing, reset. If not
[MPJ on ―F‖ OR ―R‖] resetting, remove CCLSA (in MPCS loco try with
bypassing Q-51 by putting HPAR or HQ51 on ―0‖.
3) If QRS is in de-energized condition, Wedge QRS in
energized condition.
4) Check Proper fitment of MP couplers (2 Nos).
5) Operate EEC- Resume traction.
If unsuccessful :
Try with MP or EEC from rear cab and clear block
section only (observing GR & SR in force).
ON ARRIVAL AT STATION-OR IF unsuccessful
6) Ensure ZSMGR knob and ZSMS are in correct
Position.
7) Check SMGR pressure 3.0 to 3.5 kg/cm2
8) Operate BL few times.
9) Check Q51, if energized condition, then wedge Q 51 in
de- Energized condition and resume traction.
10) Check Q52, if Q52 is in energized condition- Wedge
Q52 in de-energized condition - Resume traction.
IF Q51 & Q52 are good (i.e. DE-ENERGISED) or
If unsuccessful:
11) Operate GR manually few times from ‗0‘ to 10 & back
to ‗0‘ and resume traction if unsuccessful.
12) Clear block section by manual control of GR in
SU/Leading loco.

In MU:
If load permits – clear block section with good loco. If load
does not permit – contact LC/SM/SCR for assistance
loco.

Page 41 of 105
TOTAL LOSS OF TRACTIVE EFFORT
OR
IMPOSSIBILITY TO START DURING TRACTION, AMMETERS DO NOT DEVIATE

1. b. GR IS PROGRESSING

Probable defect/
Observation/ Checking Action to be taken by the Loco Pilot
GR is progressing but ammeters Ensure MR pressure is 8 kg/sq. cm.
are not deviating. Try from rear cab- Clear block section
observing GR & SR rules in force.
If unsuccessful from rear cab or on
arrival at the station.
Operate HVSI-1, HVSI-2, HVMT-1 and
HMVT-2 few times from 1 to 0 and back to 1.
Operate HMCS-1 & HMCS-2 few times from
1 to 4 and back to 1.
Manually operate line contactors few times.
Manually operate all CTFs few times.
Ensure they are in ‗TR‘ (UP) Position.
Check for any air leakage from line
contactors or its pipe line – try to arrest the
leakage.
Check EP cut out cock. If close, open EP
cocks.
Check 3 numbers BD couplers below rotating
switch board for proper fitment. .
Resume traction.
Operate relay Q50 few times and try again.
If unsuccessful, drain out the MR pressure
and try again.

IF UNSUCCESSFUL TO RESUME If unsuccessful, In case of SU Loco - Request


TRACTION for assistance.
In case of MU /Consist – If load permits –
Clear block section with good loco.
If load does not permit - Contact LC/SM/SCR
for assistance loco.

NOTE :
 In MU / Consist – During starting or on run -
 If ammeters on leading loco deviate abnormally high, check the trailing loco.
 If GR progressing but both ammeters do not deviate refer 1.b. above
 If both ammeters are deviating on all locos check the train for brake
binding.

Page 42 of 105
TOTAL LOSS OF TRACTIVE EFFORT AFTER USING RHEOSTATIC BRAKING

Probable defect/
Observation/ Checking Action to be taken by the Loco Pilot
I. IF LSB DOES NOT GLOW Ensure MP on ‗O‘ and observe glowing of LSB
putting MPJ on ‗F‘ or ‗R‘. If LSB does not glow,
trouble shoot as per page number: 41 (Trouble
Shooting for TLTE).
II. IF LSB GLOWS Take safety measures and-
a) Check CTF-1, CTF-2 & CTF-3 are in ‗TR‘
(UP) position.
If CTFs are on ‗BR‘ position – bring them to
‗TR‘ position. (Manually operate the CTF
electro valves).
Ensure C145 is in open condition, If C-145 is
closed – Open C145. (Manually operate the
CTF electro valve) and resume traction.
If unsuccessful – try from rear cab.
Resume traction – Clear block section
observing GR & SR in force.
If unsuccessful – clear block section by manual
control of GR in case of SU/leading loco in
MU.

In MU/consist:

If load permits – Clear block section by good


loco.
If load does not permit - Contact LC/SM/SCR
for assistance loco.

NOTE:

 In MU manual control of GR is not permitted on trailing loco.

 In case of CTFs /J1 & J2 are to be operated manually due to failure of


electro valves or air pressure, close EP cut out cock first and then set
CTFs /J1 & J2 in the required position. After manual operation – open EP
cut out cock.

 On opening EP cut out cock if any CTF again back to BR position. Secure
that CTF with rope in the TR position and do not use RB.

Page 43 of 105
REDUCTION /LOSS OF TRACTIVE EFFORT

1. LSP GLOWS ON RUN WITHOUT SLIPPING AND GR COMES TO ‗O‘ IN SU


OR MU/CONSIST WAG- 5, WAM - 4 (6P), WAG - 7, WAP - 4 LOCOS OR
AUTO REGRESSION ON IST NOTCH WITH LSP GLOW.
Remark -1: For SU
Remark -2: For MU
REMARK – 1
Probable defect/ Action to be taken by the Loco Pilot
Observation/ Checking
ENSURE ZQWC/BPQWC is not operated in all cabs, Put HMCS-1 and HMCS-2
on position –III and take two traction notches. Observe both ammeters.
I. IF BOTH AMMETERS - Put back HMCS-1 on position -1 and take two
/BOTH CAB AMMETERS traction notches, observe for auto regression of
DEVIATE GR with LSP glow.

a. If LSP glows with Auto regression


Put back HMCS- 1on position-III and, HMCS-2
on position-1.
Resume traction. (TM -2 isolated).
b. If LSP does not glow and Auto regression
does not takes place.
Maintains HMCS -2 on position –III. .Resume
traction (TM-5 isolated).
II. IF LEFT HAND SIDE Put HMCS -1 on position -IV and
AMMETER -A1/Cab-1 (A-3) HMCS -2 on position -1.
DOES NOT DEVIATE Resume traction. (TM-3 isolated).
Ensure working of TM-2 by observing U-2 on run.
III. IF RIGHT HAND SIDE Put HMCS -2 on position-II and
AMMETER - HMCS -1 on position-1.
A2/Cab-2 (A-4) Resume traction (TM-4 isolated).
DOES NOT Ensure working of TM-5 by observing U-5 on run.
DEVIATE.
IV. IF BOTH AMMETERS Put HMCS-I on position –IV and HMCS-II on
NOT DEVIATE. position-II. Resume traction.(TM-3 &TM-4
isolated)
REMARKS- II
 Trouble shoot as per Remark-1 for leading loco
 Put BLSN down on leading loco.
 Check the TMS (Ammeter) as per trouble shooting mentioned in
Remaks-1
 If no trouble is experienced on leading loco – Proceed to trailing loco
 Do trouble shooting by keeping BLSN down on the trailing loco as per
instructions laid down in Remark-1.
NOTE :
 In case experienced reduction of Tractive Effort without auto regression
of GR: Check all the ammeters and voltmeters if any voltmeter and/or
ammeter does not deviate, isolate the corresponding TM and inform

Page 44 of 105
TLC & record in the loco log book.
 On locos having two voltmeters and one ammeter in each cab
(modified) observe both ammeters on both cabs whenever required.
 Do not use MPS If auto regression takes place with LSP glow.
ISOLATION OF TRACTION MOTORS

POSITION OF HMCS HMCS1 HMCS2


I TM 1-2-3 are in service TM 4-5-6 are in service
II TM1- is isolated TM4 is isolated.
III TM2- is isolated TM5 is isolated.
IV TM3- is isolated TM6 is isolated.

2. AUTO REGRESSION OF GR WITHOUT GLOWING OF ANY LAMP ON LOWER


NOTCHES/1st NOTCH.

Probable Defect/
Observation/Check Action to be taken by the Loco Pilot
Ensure QVCD is de-energised in case of VCD fitted loco.
IF QVCD ENERGISED  If energised. Reset VCD
 If still energised, Put HBA on ―0‖ then again on ―1‘
and try.
 If unsuccessful – isolate VCD by HVCD.
 If unsuccessful wedge QVCD in de-energised
condition.
In case QVCD de-energised-
BL DEFECT  Operate BL key & BPR switch in both cabs few
AND/OR times. Try to resume traction,
BPR in PRESSED*  If unsuccessful, resume traction with EEC.
 If unsuccessful, clear block section from rear cab,
Observing GR & SR rules in force.
 If unsuccessful, clear block section by manual
control of GR.

3 AUTO REGRESSION OF GR WITHOUT GLOWING OF ANY LAMP ON


HIGHER NOTCHES.

Probable defect /
Observation /Checking Action to be taken by the Loco Pilot
ACTION OF Q20 If auto regression is experienced without the use of
(ENERGISED) MPS.
 It may be due to the action of Q20.
 Note the TM voltage at which auto regression takes
place.
 Resume traction – Work at lower notches.

Note:Do not use MPS,if auto regression with LSP glow takes place on
using MPS.

Page 45 of 105
4. SMOKE OR ABNORMAL SOUND FROM THE TRACTION MOTORS:

Stop the train and observe the concerning traction motor

Probable defect / Action to be taken by the Loco Pilot


Observation /Checking
 SMOKE EMISSION FROM If the defective traction motor is detected:
TRACTION MOTOR  Isolate the defective TM.
 Resume traction observe the TM on run for
any smoke or abnormal sound.
 SMOKE EMISSION FROM  Detect the damaged suspension bearing.
SUSPENSION BEARING,  Isolate the corresponding traction motor.
GEAR CASE  Clear block section cautiously.
 On arrival at station – Ask for Relief loco.
 SLIPPED PINION If the damaged traction motor is not detected.
 Stop the train
 Advise the Assistant Loco Pilot to stand
near the track.
 Apply IAB, take two traction notches.
 Ask the Assistant Loco Pilot to observe
armature of all traction motors.
 If any armature rotates– Isolate the
corresponding traction motor.
 Resume traction – Clear block section.
 On arrival at station – request for
assistance/Relief loco.
 LOCKED AXLE Observe the rotation of all the wheels by moving
loco –
If any pair of wheels are not rotating –
 Isolate that particular TM.
 Move the loco forward and backward two to
three times.
 Observe wheel rotation.
 If all wheels are rotating – Continue
traction.
 If any pair of wheels is not rotating –
Request for assistance.

Page 46 of 105
5. GR DOES NOT PROGRESS BEYOND ONE/CERTAIN NOTCH IN SU/MU/CONSIST

Probable defect / Action to be taken by the Loco Pilot


Observation /Checking

 CHECK Q52 IN SU IF  Bring MP to ‗O‘


ENERGISED
 Try with EEC and resume traction
If unsuccessful,
 Wedge Q52 in de-energised condition [for SU ]
 Wedge Q49 in de-energised condition [on
affected /trailing locos in MU/Consist and
Resume traction.

6. CONNECTION OF AMMETERS –VOLTMETERS & QD in WAG-5, WAM-4(6P),


WAG-7 & WAP-4 Locos

CAB-1 Voltmeter (UMT-1) Indicates voltage for TM-1


Left hand side ammeter (A-1) Indicates current for TM-3
Right hand side ammeter (A-2) Indicates current for TM-4
Cab-2 Voltmeter (UMT-2) Indicates voltage for TM-6
Left hand side ammeter (A-1) Indicates current for TM-3
Right hand side ammeter (A-2) Indicates current for TM-4
QD-1 Connected between TM-2 & 3
QD-2 Connected between TM-4 & 5

7. CONNECTION OF AMMETERS AND VOLTMETERS FOR LOCOS WITH TWO


VOLTMETERS AND ONE AMMETER IN EACH CAB (MODIFIED):

CAB-1 Voltmeter (U-1) Indicates voltage for TM-1


Voltmeter (U-2) Indicates voltage for TM-2
Ammeter (A-3) Indicates current for TM-3
Cab-2 Voltmeter (U-5) Indicates voltage for TM-5
Voltmeter (U-6) Indicates voltage for TM-6
Ammeter (A-4) Indicates current for TM-4

Page 47 of 105
(CHAPTER – III )

MISCELLANEOUS FAILURES

1. PNEUMATIC FAILURES
Page No.
A) MR pressure not building up/ maintaining 51
B) RS pressure not building up 52
C) BP pressure not building up/maintaining 53
D) BP pressure not building up after cattle run over 54
E) BP pressure fluctuating on run 54
F) BP not dropping by DAB/A-9 54
G) Loco brakes not releasing 54
H) ACP on WAP 4 locos 54

2. ELECTRICAL FAILURES :

Page No.
A) Pantograph failures 55
B) DJ locked in closed position 56
C) All auxiliaries are not working (CCA fuse melted) 61
D) All pilot lamps not glowing during opening of DJ 62
E) MVRH, MVMT-1 OR MVMT-2 does not start on closing BLVMT 62
F) LSCHBA glows on run (ARNO Fitted Loco) 63
G) LSCHBA glows on run without tripping (SIV Fitted Loco) 63
H) CPA does not start when ZCPA is closed 64
I) Cab lights/compartment lights are not glowing 64
J) Marker lights does not glow 64
K) Head light does not glow 65
L) Notch repeater is not working 65
M) Cab fans are not working 65
N) Cab heaters are not working 65
O) All sanders are not working 65
P) LSB glowing during RB 65
Q) LSRSI glows on run/remains glowing 66
R) LSB glows with MP is placed on ‗P‘ but does not extinguish. 66

Page 48 of 105
1. PNEUMATIC FAILURE

Probable defect / Action to be taken by the Loco Pilot


Observation /Checking
A. MR pressure not Close BLCPD. Check the working of MCP.
building up If MCP not working-
ARNO FITTED LOCO :
 Close BLVMT, Check working of Blowers – if blowers
are also not working – Refer trouble shooting of All
Auxiliary not working page No. 57.
 If Blowers are working – Change the position of
ZCP/HCP.
 Check C101/102/103-if open wedge as per
requirement.
 Create leakage by opening MR2 drain cock and
work.
SIV FITTED LOCO:
 Ensure LSCHBA is extinguished- if glowing refer
miscellaneous failure of LSCHBA remains glowing.
 If LSCHBA extinguished---Close BLVMT, Check
working of Blowers – if blowers are also not working
– Refer trouble shooting of All Auxiliary not working.
 If Blowers are working – Change the position of
ZCP/HCP.
 Check C101/102/103-if open- Ensure QTD101 is
energized.
 If QTD101 is de-energized condition – wedge in
energized condition.- if successful always close
BLCP after 5 seconds of LSCHBA extinguish –
Resume traction.
 If QTD101 is energized– wedge CP contactors as per
requirement. Create leakage by opening MR drain
cock and work.
 If VCB close, SIV pick up but LSCHBA glows and
MCPs not working wedge QCON in energized
condition and close DJ by manual operation of
Q118..
If MCPs are working
 Check the MR gauge in both the Cabs. If both cabs
pressure shows ―0‖ or less.
 Change the position of ZCP/HCP.
If pressure does not building up.
 Ensure DAB isolating cocks are open in driving
cab.
 Check leakage from safety valve, unloader valve,
Auto Drain valve, MR drain cocks, Sanders, MU air
hoses on both side & Angle clocks C2 relay valve, D1
Page 49 of 105
& D2 Assistant Loco Pilot Emergency valves & air
dryer.
● Ensure MR4 cut out cock is open.

 In case of leakage from one of the unloader valves


or safety valves- isolate the corresponding MCP.
 In case leakage from all unloader valves or safety
valve – Isolate VEAD isolating cock. Work with
BLCPD.
 In case of air leakage from sanders. Isolate the
corresponding sander electro valve. Close the
sanding cut out cock.
 In case of leakage or damage from MU air hose,
Isolate angle cock between the locos. Build up MR
pressure individually on each loco. Resume traction.
 In case of air leakage from Auto Drain valve. Close
Auto Drain valve isolating cock.
 In MU/Dead loco – Ensure LT cock/MU-2B on trailing
loco is on closed/trail position & C2N feed valve/D-
24B-feed valve. Cock is in closed condition.
 Ensure no leakage from IP. If there is any leakage
from IP. Close IP isolating cock.
 If leakage from air drier, By-pass Air dryer.
 .Ensure C2N feed valve should be in open on
working / leading loco.
B. B. RS PRESSURE Ensure BA voltage is more than 80 Volts.
NOT BUILDING UP  Ensure CPA is working. If not working check CCBA.
 Ensure RAL is open.
 Ensure RS drain cock & CPA drain cocks are
closed.
 Ensure ZPT on O on both Cab,
 Check leakage from CPA, safety valve, both VEPT
&, RDJ and its drain cock, DJ oil separator. VCB
chambers & BV box.
 if found leakage from CPA safety valve- tap gently.
 If found leakage VEPT isolate that VEPT cock
 If found leakage from any drain cock, isolate that
drain cock properly.
 If found leakage from VCB chamber and BV box-
operate BV by inserting ZPT key few times. put on
normal and try.

If there is no leakage – Close RAL cock :


 Build up pressure for ten minutes even if RS gauge
does not indicate any Pressure. Raise panto –
Close DJ.
 If unsuccessful – Close Air control Cut Out Cock
and build up RS pressure – Close DJ – Build up MR
Pressure- open air control cut out cock.
Page 50 of 105
C.BP PRESSURE NOT ● Close BP angle cock of loco towards train.
BUILDING UP/
 Check BP gauge in both CAB‘S.
MAINTAINING
If BP pressure is building up-
 Check the train for any leakage,

If BP pressure is not building up, check the


following:
 MR pressure is above 8 kg/cm2 in MR
gauge.
 Isolating cocks of DAB/A9 are properly
open in the driving cab and closed in non
driving cabs.
 LT cock open, MU-2B is in leading position,
if MU-2B is in leading position then operate
it few times & again keep it in leading
position.
 No leakage from C3W distributor valve,
 If there is leakage from Mechanical IP valve
(E3W) –Ensure QVCD is in de-energized
condition.
 If unsuccessful Isolate mech. IP (E3W)
valve.

Note:
 On trailing loco/locos in MU/Consist or dead
loco –ensure IP valve is isolated.
 In MU/Consist- Ensure LT cock is in closed
position and MU-2B on trail position on
trailing locos.
 Check leakage from DAB/A9 – Operate A9
few times – properly.
 Drain the moisture in MR.
 Gently tap C-2 relay valve for BP charging–
If necessary,
 Operate few times D1/D2 – Emergency
valve if necessary,
If unsuccessful – Change the cab and work the
train from rear cab/rear loco (after isolating inter
mediate BP angle cock) in MU/Consist as per GR
& SR rules in force.

NOTE: If BP gauge shows ‗O‘ in driving Cab and 5.0Kg/Cm2 in rear Cab, then check
BP additional angle cock in rear Cab .If is in close position open the same.

Page 51 of 105
D. BP PRESSURE Isolate the additional BP angle cock ( if provided)
NOT BUILDING UP If additional BP angle cock not provided –
AFTER CATTLE Contact LC/SM/SCR for advice.
RUN OVER  In case of cattle run over Loco pilot must inform
LC/SCR.
E. BP PRESSURE  Use BLCPD.
FLUCTUATING ON  Maintain minimum 9 kg/ cm 2 MR pressure.
RUN
F. BP NOT DROPPING  Ensure A9 inlet/outlet cocks are in proper position in
BY - A9 . all cabs, LT cocks & MU2B valves are in proper
position.
 Operate A9 a few times.
If unsuccessful, Drain out MR pressure and re-build.
 Gently tap C-2 relay valve for BP charging.
 Operate MU-2B valve few times & keep it in leading
position.
If still unsuccessful, drive from rear cab/ rear loco in
MU/Consist observing GR & SR rules in force.

G. LOCO BRAKES  Ensure BP is 5.0Kg/Cm2.


NOT RELEASING  Ensure DAB/IAB inlet/outlet cocks are in proper
position in all cabs, LT cocks & MU2B valves are in
proper position in all locos.
 Keep IAB /DAB in released position.
 Isolate C3W distributor valve.
 Release C3W distributor valve of loco/locos.
 Ensure the brake cylinder gauge needle comes to ‗O‘.
 Drain out full MR pressure and re-build - Release loco
brakes.
If still brake do not release -
 Gently tap on C2 relay valve for loco brakes & double
check valve.

H. ACP ON WAP4 To check ACP function.


LOCOS  Put MPJ in ‗F‘ or ‗R‘
 Put BLVMT ‗ON‘. Press ‗TS‘ for 5 seconds.
 If ACP buzzer blows continuously
 Press ‗BIS/SW switch to stop buzzer sound.

Page 52 of 105
2. ELECTRICAL FAILURES

Probable defect observation/checking Action to be taken by the Loco Pilot.


Check RS pressure is to be more
A. PANTOGRAPH FAILURES than 8 kg/cm2.
Change the position of ZPT-
 If other panto raises – resume
traction.
If other panto does not raise –
 Check BA Voltage, if showing ―0‖-
replace additional CCBA fuse/MCB.
 If BA Voltage is above 80V check -
CCBA & CCPT
 If CCBA, additional CCBA/MCB &
CCPT are good - check VEPT
isolating cocks for proper opening.
 Operate VEPT manually few times –
Resume traction
NOTE:
 Ensure BPEMS is not in pressed
condition and QEMS is de-energized.
 HLS /ZLS not in ―O‖ position (if
provided).
IF CCPT MELTS  Renew the fuse – Resume traction.
IF CCPT MELTS AGAIN  Put HOBA in ‗OFF‘ position on all
locos and renew CCPT– Resume
traction.
 If melted again, clean fuse holder and
replace CCPT.
IF CCPT MELTS AGAIN AFTER  Change the panto and renew CCPT.
PUTTING HOBA ‗OFF‘  If unsuccessful –Try from other cab in
SU/ rear loco in MU/Consist.
 If successful, clear section from
cab/loco observing GR & SR in force
and inform LC/SM/SCR.
 If unsuccessful-Request for
assistance.
 Lower the pantograph and stop the
IF PANTO IS DAMAGED train immediately. Isolate
corresponding VEPT cut out cock.
 Check loco roof & look out for any
abnormality or foreign body like tree
branches/ wire, etc.
 Contact LC/TPC & Section Controller.
 After securing the damaged
pantograph - Resume traction by
other pantograph.
Note : Loco Pilot should not start the
train unless the pantograph has been
secured.
Page 53 of 105
Page 54 of 105
B. DJ LOCKED IN CLOSED POSITON If the pantograph is raised –

Checking signs:  Lower the panto immediately.


I. LSDJ remains extinguished on  Ensure glowing of LSDJ in other Cab
Unlocking BL. OR  If LSDJ glows – Resume normal
LSDJ not glowing but LSCHBA, traction.
LSGR & LSGRPT glowing on  If LSDJ does not glow – increase
Unlocking BL. RS Pressure more than 8 kg/cm2 and
open BLDJ.
 If LSDJ glows – Resume traction.
II. On opening BLDJ, LSDJ does not If LSDJ does not glow – Close BLDJ press
glow, UA does not drop to zero, and BLRDJ, raise pantograph and observe UA
auxiliary noise does not reduce. needle( in STC loco, BLRDJ need not to be
pressed).
If UA needle deviates:
III. In case of No Tension on line LSDJ  Release BLRDJ after LSCHBA goes
does not glow, UA drops to ‗0‘, out.
LSCHBA glows and auxiliary sound  Resume traction and clear Block
reduces. section.
 Observe UA & LSCHBA on run and
inform LC.
 Frequently check for any smoke
emission from power/auxiliary circuit.
 Ensure proper functioning of the
auxiliaries on run.
 Check safety relay targets.
If UA needle does not deviate:
 Lower pantograph and observe
instructions for ‗No tension‘ on line.

NOTE :

In case of DJ locked in closed position :


 To trip DJ at neutral section or whenever necessary – Lower Pantograph.
 To Close DJ – Close BLDJ press BLRDJ, raise pantograph and observe UA.
Release BLRDJ after LSCHBA goes out. On opening BLDJ, LSDJ does not glow
on both Cab but UA drops to ‗O‘ and auxiliary sound stops-defects in QV-60.

Page 55 of 105
Page 56 of 105
Probable defect / observation/ Action to be taken by the Loco Pilot
checking
C. all auxiliaries not Check CCA FUSE
working(auxiliaries start by own
“bl”switches) in SU
1. IF CCA GOOD Check Q -100 /QTD-100 with DJ closed condition.
If Q100/QTD-100 de-energised:

 Trip DJ, wedge Q100/QTD-100 in energised


condition close DJ and resume traction if all
auxiliaries working..
If unsuccessful / if Q-100/QTD-100 is energised
 Take safety measures - wedge all contactors
C105, C106,C107 & C101/C102/C103 as
per requirement.
 Close DJ/VCB by manually operating Q
118.Create leakage from MR2..
 Resume traction.
2. IF CCA MELTED  Open BLCPA, BLVMT
 Renew fuse & close DJ
2a) IF CCA HOLDS  Close BLCPA and BLVMT one after another
& observe CCA.
NOTE :- This must be ensured
properly. i.e, After replacing CCA- If CCA melts on closing BLCPA
first put HBA on ‗1‘ and again to ‗0‘.  Change the position of HCP/ZCP.
Then check CCA – If CCA melts, it  Renew the fuse and resume traction.
means trouble in Q119 and VEUL  If CCA melts again on closing BLCP, Put
branch. HCP/ZCPs on ‗0‘/OFF and wedge
C101/C102/C103 as per requirement. Create
Again check CCA after closing DJ leakage from MR.2. Do not close
without closing BLCPA or BLVMT, BLCP‘A/BLCP‘D. Renew CCA & Work the
taking safety measures- If CCA melts train and inform LC.
at this juncture, it means trouble with
Q100/QTD 100 branch. If CCA melts on closing BLVMT
 Remove CCA.
If both times on checking finds CCA
 Wedge C105, C106, C107, and C101 / C102
not melted, then only considered/
/ C103 as per requirement.
recognized as CCA holds in this
 Close DJ by operating Q118 manually and
case.
create leakage from MR2 and work the train
up to destination.

 Put HOBA off in all Locos


2b) IF CCA MELTS AGAIN  Renew fuse and close DJ
 If CCA holds- Resume traction.
IF CCA MELTED AGAIN AFTER  Remove CCA.
PUTTING HOBA ‗OFF  Wedge C105, C106, C107 and
C101/102/C103 as per requirement.
 Close DJ by operating Q118
manually create leakage from MR2
and work the train up to destination

Page 57 of 105
All aux. are not working in MU  First put BLSN downwards and trouble shoot
as above for single loco.

 If during trouble shooting in leading loco, in


case CCA fuse has to be removed, after
putting HOBA in ‗OFF‘ condition:-
 Do not remove CCA.
 Wedge relay Q100 in de-energize
condition and renew CCA in leading
loco. Wedge all contactors in leading
loco as per requirement
 If no problem found in leading loco, then try
to work with single loco and clear block
section.
.
 Put BLSN switch upwards. Open all BL
At station or load not permits with switches and close DJ.
single loco, do trouble shooting as  After closing DJ, close BLCPA.
follows:- A) If compressors stop working in leading
loco, check CCA in leading loco
If CCA is melted- it means trouble with
trailing loco compressor circuit :-
 Put HCP on ‗0‘ in trailing loco.
 Increase number of compressors in
leading loco.
 Renew CCA fuse in leading loco and
resume traction.
 If MR is not maintaining, then wedge any
of compressor contactor in trailing loco
after taking safety measures.

B) If compressors are working, close BLVMT.


In case blowers fails to start- check CCA of
leading loco
If CCA is melted- it means trouble with
trailing loco blowers circuit :-
 Take safety measure. Wedge
Q100/QTD-100 in de-energize
condition in trailing loco.
 Wedge C105, C106 & C 107 in
trailing loco.
 put HVMT1,HVMT2 & HVRH on ‗3‘ in
trailing loco.
 Increase number of compressors in
leading loco, if required.
 Contact TLC .
NOTE :- 1) In case trailing loco CCA is melted, LP would get tripping in Operation 2 in trailing loco. To
overcome this problem, LP has to wedge relay Q100 in energize condition in trailing loco.
Need not to renew CCA fuse.
2) Whenever CCA fuse is removed, it ceases the action of Q119 and VEUL. So, LP should take
care of compressors while closing BLCPA/BLCPD for back pressure in MCP pipeline.

Page 58 of 105
Page 59 of 105
IN SIV FITTED LOCO : If SIV is not working – Trouble shoot for SIV fails to start.
• If SIV working but ALL AUXAILIRIES not working-- Check CCA only ,if
melted renew the same.

• If CCA melting even after HOBA ―OFF‖, wedge the


contactors as per requirement and close DJ normally.
IF CCA melting after closing BLVMT:-
• In SU as well as in MU keep BLVMT open and
clamp all blower contactor, resume traction.

D. ALL PILOT LAMPS ARE NOT Check BA voltage:


GLOWING DURING OPENING OF
 If BA voltage is ‗0‘-operate HBA few times
DJ/UNLOCKING BL.
and ensure HBA is on‘1‘ If unsuccessful –
Replace Additional CCBA/ reset MCB
provided near BA BOX no.1
 If BA voltage is ‗0K‘– Check CCLS-If CCLS
melted- replace.
 If CCLS fuse melts again – put HOBA in
‗OFF‘ position in all locos.
 Renew the fuse CCLS. Resume traction.
 If CCLS again melts – wedge QRS in energised
condition, isolate IP COC, close DJ and Clear
block section only.

E. Blowers MVRH,MVMT-1&  Ensure HVRH, HVMT-1 & HVMT-2 are on


MVMT-2 does not start, when position ‗I‘ or ―III‖.
BLVMT is ON  Check the contactor C105, C106 & C107, if
open take safety measure, operate
contactors manually few times & try.
If unsuccessful Wedge the contactors and
closed DJ by manual operation of Q118 (in
ARNO loco only). Resume traction.

F. LSCHBA GLOWS ON RUN Continue traction and on arrival at station:


WITHOUT TRIPPING
 Put HBA on ‗0‘on DJ close condition – wait
(ARNO Fitted Loco)
for 15 seconds.
 If DJ does not trip – put back HBA to ‗ON‘
position.
 Ignore LSCHBA- Resume traction.
 If DJ trips- check the cartridge fuse /MCB
provided on Battery Charger (CHBA)
 If the fuse is melted – replace with 16 amps
fuse/ reset MCB -resume traction.
 If the fuse is good – check the BA voltage.
 If it is more than 80 volts,and charging
current more than 2 AMPS. put HCHBA on
‗0‘.
Page 60 of 105
 Inform LC, Enter in the Loco logbook.
 Work the Locomotive for 4 hrs.
 Minimize battery load .
Check the SIV panel :
G. LSCHBA GLOWS ON RUN
WITHOUT TRIPPING I) If CHBA ‖OK‖ indication LED is glowing –
(SIV fitted loco)
 Close BLCPA/ BLCP‘D
OR  If CPs are not working – Wedge QCON
in energised condition – Manually
SIV Working but LSCHBA operate Q118 to Close DJ/VCB.
remains glowing –  Close BLCP after 5 seconds of SIV
picked up.
 If Compressors are working –Ignore
Probable defects – LSCHBA resume traction and
 frequently check the working of CHBA.
i) QCON not pick up
ii) CHBA is not working II) If CHBA ―ok‖ indication LED is not
glowing – If loco is in block section
 Reset the SIV.
 Ensure BA voltage above 90 volts
 Close DJ and if SIV working and
Close BLCPA/ BLCP‘D
 If CPs are not working – Wedge QCON
in energised condition – Manually
operate Q118 to Close DJ/VCB.
 Close BLCP after 5 seconds of SIV
picked up.
 If Compressors are working –Ignore
LSCHBA resume traction and
 continue traction and inform TLC
 Minimize BA load and frequently check
BA voltage on run. Clear block section
and contact with LC.

H. CPA DOES NOT START Check BA Voltage.


WHEN ZCPA IS ON POSITION.
 If BA Voltage ―0‖- operate HBA few
times

If unsuccessful –

 Replace additional CCBA/ reset MCB near


BA Box No.1.
 If BA Voltage is more than 80V - Check
CCBA
 If CCBA fuse is melted – replace fuse
CCBA.
 If it melts again – put HOBA in ‗OFF‘ on all
locos.

Page 61 of 105
 Replace fuse CCBA – Put ZCPA‖ON‖ to
start MCPA.
 If the fuse is good – check the terminal of
ZCPA and CPA.
 If disconnected, connect the same and try.
I. CAB/ COMPARTMENT  Ensure bulb is good.
LIGHTS ARE NOT GLOWING  Check CCLC.
 If fuse CCLC is melted – Renew fuse.
J. MARKER LIGHTS ARE NOT  Check CCLF1/CCLF2. If melted- Renew
GLOWING the same
K. HEAD LIGHT DOES NOT  Put on BLPRD-If head light glows-work
GLOW normally
 If head light does not glow- ensure
ZPR/ZRT is ON, if provided. If
unsuccessful.
Put ON BLPRR:
 If the rear head light glows.
 Check the front head light holder.
 If it is good - Change the bulb (if
possible).

If rear headlight does not glow.


 Operate BL few times
 Change the position of DC-DC converter
change-over switch.
 Check the glowing of headlight.
If head light does not glow- work the
train with glowing of marker light
observing GR & SR in force and inform
LC.

Page 62 of 105
 Check CCVT and CCTFS if melted renew it
L. NOTCH REAPTER IS NOT  if un success Continue traction.
WORKING  Enter in the loco log book and inform LC
 On SIV Fitted loco change the position of
HRAVT.
 Checks CCVT –If melted renew CCVT.
M. CAB FANS ARE NOT  On SIV Fitted loco change the position of
WORKING HRAVT.

 Check CCRA-1 & CCRA-2.If melted renew the


N. CAB HEATERS ARE NOT fuse.
WORKING  On SIV Fitted loco change the position of
HRAVT.
 Check CCLS – if melted renew fuse.
O. ALL THE SANDERS ARE NOT  Ensure all VESA isolating Cocks (4 Nos) and
WORKING sanding cut out cocks are open.
 Ensure sand in the sand boxes.

 Bring MP to ―0‖-Wait till LSB extinguishes


P. LSB GLOWING DURING RB  Check QF1, QF2 and QE.
 If any of them is showing red, reset & use RB.
 If LSB glows again and the above target drops
do not use RB
 If all targets are normal- Use RB not exceeding
–900A.

Q. LSRSI GLOWS ON RUN Ignore LSRSI – Clear Block section.

On arrival at next station- Stop the train:


 Open DJ/VCB, Lower pantograph and
put HBA on ‗0‘, observe LSGRPT/LSOL
in MU/Consist.

Check the Tell-tale fuses :

 Remove the melted Tell-tale fuses.


i) IF 1 OR 2 OR 3 FUSES ARE Resume traction after LSRSI is
MELTED IN THE SAME ARM / extinguished
ROW

Page 63 of 105
ii) IF 4 FUSES ARE MELTED IN  Remove the melted tell tale fuses.
SAME ARM / ROW. Isolate the corresponding block. If load
permits- Resume traction. If load does
not permit-Contact LC.

NOTE: where LED indication lamp is provided instead of tell – tale fuse-
1) 6 LED lamps in one RSI block - If one LED indication Lamp is glowing, then isolate
the corresponding block.
2) 14/18 LED lamps one RSI block –
a) If one LED indication Lamp is glowing in having, operate micro switch and work
carefully observing RSI block.
b) If 2 LED indication Lamp is glowing in one RSI block - then TM to be isolated by
HMCS .
c) If more than 2 LED indication Lamp is glowing in one RSI block - then
correspondence RSI block to be isolated.
iii) IF NO FUSE IS MELTED Ignore the glowing of LSRSI.
Enter in the loco logbook – In form LC.
Resume traction.

R. LSB Remains Glowing on  Checks J1 & J2 in desired direction


putting MPJ on ‗F‘ or ‗R‘.  Ensure CTF1 , CTF2 & CTF3 are in TR
position
 Ensure LSC-145 is not glowing and
C145 is Open.
 Resume Traction.
If unsuccessful check Q-50 in DJ close condition
after putting MPJ “F”/”R”.
 If Q50 is de-energised – Wedge in
energised condition, Resume traction
If unsuccessful:
 If load permits- Clear block section by
good loco in MU/Consist and inform LC.
 If load does not permit or SU- clear block
section by manual control of GR.

Page 64 of 105
CHAPTER-4

CONTENTS Page No.

A. Microprocessor. 67

B. Static Converter. 90

C. Precautions on relay wedging. 105

D. Air Dryer. 106

E. Instructions for working from leading loco in


107
MU/Consist in case of defect noticed on
leading loco.

F. Parts of the OHE cantilever. 108

G. Parts of the Pantograph. 109

Page 65 of 105
MICROPROCESSOR BASED LOCOMOTIVES

1. SYSTEM CONFIGURATION:

a. A MAIN UNIT-provided near ARNO or near relay panel.


b. Two display units- one in each cab.
c. Signaling & conditioning units - i) AUX voltage ii) ARNO/SIV voltage iii) Traction Motor
voltage (each unit is mounted in BA1 and BA2 panels)
iv) Battery Charger voltage

The following relays removed from the loco:

Q20 Q30 Q44 Q45 Q46 Q48 Q49 Q50 Q51 Q52 Q100 Q118
Q119 QV60 QV62 QV63 QV64 QWC QRS QTD105 QTD106 PR1 PR2
(QCON in SIV Locos)
In some locos QD, QCVAR, QV61, Q30 are also not provided.
HQCVAR SWITCH IN THAT CASE IS NOT PROVIDED

The Following Relays Are Available In Loco:

QOA,QOP1,QOP2,QRSI1,QRSI2,QLM,QLA,QPH,QVSL1&2,QVSI1&2,QVMT1&2,QVRH,
QPDJ,QVRF,QFL(QD1,QD2,Q30,QCVAR,QV61 IN SOME LOCOS)

New Switches Provided:

BPQD-provided near BPP&BPR to prevent auto regression of GR due to wheel


slipping. It works up to 10th notch.

HPAR/HQ-51:-: Two position switch having ―0‖&‖1‖.Normal position is‖1‖.If LP is getting


TLTE due to mal-function of auto flasher light, this switch is to be kept on ―0‖. Either
HPAR or HQ-51 will provided in loco.

Fuses Removed: CCDJ, CCA, CCLS, and CCLSA.

Fuse Provided: CCCPU (6A), In some locos MAIN UNIT is directly taking feed
from CCPT. (In MPCS VERSION-3,CCCPU is 16 AMPS)

KEYS PROVIDED ON DISPLAY UNIT:-

KEY PURPOSE
ENTER THIS IS COMMAND TERMINATOR.
ACK THIS KEY IS USED FOR ACKNOWLEDGEMENT OF FAULT.
MENU USED FOR SELECTION OF VARIOUS OPERATIONS.

Page 66 of 105
CURS UP THIS ALLOWS TO SEE THE NEXT CURSOR FAULT IN MEMORY
WHEN ONE IS IN CURSOR FAULT DISPLAY MODE.
CURS DN TO SEE THE PREVIOUS FAULT IN MEMORY WHEN IN CURSOR
FAULT DISPLAY MODE.

Page 67 of 105
Page 68 of 105
INSTRUCTIONS TO LOCO PILOT:

1. NO need to change position of ZSMS while driving by MP or EEC.


2. DO NOT changes any programming switch on loco energize condition.
3. Any fault occurred will be displayed on the display unit .LP has to trouble shoot
as per TSD IF SUCCESS. After trouble shooting press ACK button on the display unit.
Message will clear from the screen and will be recorded in memory.
4. If any safety relay acts trouble shoot as per TSD.
5 .In case display unit is /are not working ,keep HBA on ―0‖ for 10 seconds & put back
to ON position. if still display unit does not work and loco is in energize condition work
up to destination. If fault occurs trouble shoot as per TSD by picking up the checking
sign.
6 .If main unit is not working, pilot lamps will not glow and no message will display on
the display units in this situation
 Ensure BA Voltage is more than 90 volts.
 If not, Replace additional CCBA.
 Check CCBA, CCPT, CCCPU. If melted replace the same.
 If melts again put HOBA IN ―OFF and replace.
 If unsuccessful keep HBA on‖0‖ and wait for‖ 3‖minutes again try to close DJ.
 If unsuccessful request for assistance.

7. In case E.M. contactors is/are not closing, trouble shoot as per TSD.
If unsuccessful keep HOBA in ―OFF and try.
If unsuccessful -wedge the contactors.
8. On pressing ACK, If the fault message on screen of display unit does not clear .
Keep HBA on ‗0‘ for 3 minutes and try. If unsuccessful keep HOBA―OFF‖ and try.
9. If tripping through any circulation relay of any aux. motor, LP shall isolate the
relay 1st and close DJ- If DJ holds- check the working of aux, motor and work
accordingly like conventional loco.

ICDJ IN MICRO PROCESSOR LOCO:


1. CHECK, CCBA, CCPT, CCCPU.( if provided) If any fuse melts, replace the fuse. If
melts again, put HOBA in OFF and replace the fuse.
2. Ensure RS pressure is above 8 kg/cm2
3. Ensure VCB gauge pressure is 5.2 kg/cm2.
4. Ensure no safety relay is in dropped condition.
5. Ensure BA voltage is more than 90 volts.
6. Ensure GR is on ―0‖.
7. Ensure ZPT is other than ‗O‘
8. Try to close DJ by BP2DJ and ADL BLRDJ.
9. Ensure C118 is closing .If not operate manually few times.

Page 69 of 105
10. If ICDJ due to feedback fail through C105 or C106 – operate C105/c106 few times
after taking safety measures and try. If unsuccessful, Put HVMT1 or HVMT2
switches on ‗O‘ and try if successful –clear block section if load permits.
11. Put HBA in ―0‘ for 3 minutes and again try to energize.
12. Try from rear cab.
13. Put HQOA in ―0‖, HQOP-1&2 in ―OFF‘ position and HOBA in ―OFF‖ and try.
14. Drain full MR/RS and rebuild the pressure and try.
15. If unsuccessful request for assistance.

TLTE IN MICRO PROCESSOR LOCO :


TLTE WITH LSB GLOW-

1. Operate MPJ,2 to3 times and try.

2. Ensure J1, J2 and CTFs are in proper position and C145 Open.

3. Ensure LSC-145 is in extinguished if provided.

4. Keep HOBA in ―OFF‖ and try

.5. .If un success switch OFF HBA ,wait for 3 minutes and switch ON and try.
TLTE WITH LSB EXTINGUISH-
1.-Ensure SMGR pressure is between 3.0 to 3.5Kg/cm 2

.2.Ensure ZSMGR in proper position and PACCO SWITCH in lifted condition.


3. Ensure BP pressure 5 kg/cm2 and RGEB 2 COC is in open condition.
4 .Try with EEC operation.
5. Put HPAR/HQ-51 from ‗1‖ to ‗0‘ and try.
6. .Operate BL key few times
7. Try from rear cab.
8. Put HBA in ―0‘ for 3 minutes and again try to resume traction.
9. Keep HOBA in OFF and try.
10. Operate GR manually few times from O to 10 and back to O and resume
traction.
11 .If unsuccessful try to clear the section by manual control of GR
TLTE WITH GR PROGRESS BUT AMMETER NOT DEVIATE---
1.Ensure MR/RS pressure is above 8.0 kg/cm2.
2.Ensure HVSI-1,HVSI-2,HVMT-1,HVMT-2 in ―1‖ position, try by changing to ―3‖.
3.Ensure EP-1 and EP-2 cocks are in open condition.
4.Tap CTF handles gently and keep in proper direction.
5 .operate LINE CONTACTORS manually few times and try.
6.If still not success, try from rear cab.
7.If still not success, keep HBA in OFF and ON and try.
8. If not success put HOBA ―OFF‖ and try.
9.If not success ask for assistance.

Page 70 of 105
Sometimes, the fault diagnostic systems may give erratic information leading to wrong
guidance since they are not stabilized fully. Hence Loco Pilots should follow the normal
procedure of troubleshooting

TROUBLE SHOOTING FOR MICROPROCESSOR LOCO DESIGNED BY MEDHA


If any fault message comes on display unit with buzzer, note the fault message and then press
―ACK‖

Sr.
No. Fault message on display unit Duties of Loco Pilot
1 C118 N/C Contact Fail Check C 118 is opened fully.
Ensure C118 Opening Do not Press Operate C118 manually few times.
BLRDJ
2 C118 Stuck up Release BLRDJ and ensure C118 is
Ensure opening of C118 opened fully
Release BLRDJ if pressed
3 No Tension Trouble shoot as per TSD of WAG5
Wait for OHE Voltage
Retry to close DJ
4 OHE low / No Voltage Trouble shoot as per TSD of WAG5
Apply Emergency Brake
5 DJ tripped Via QOP-1
Reset QOP-1 isolate faulty TM by HMCS-1
6 DJ tripped Via QOP-2
Reset QOP-2 isolate faulty TM by HMCS-2 Trouble shoots as per WAG-5 TSD.
7 DJ tripped Via QOA
Put HQOA on 0
Check all Auxiliary / Heater, follow TSD
8 DJ tripped Via QRSI-1
Reset QRSI-1 isolate faulty TM by HMCS-
1
Follow TSD inform TLC
9 DJ tripped Via QRSI-2:
Reset QRSI-2 isolate faulty TM by HMCS- Trouble shoots as per WAG-5 TSD.
2
Follow TSD inform TLC
10 DJ tripped Via QLM
Check transformer / GR oil splashing.
11 DJ tripped Via QVSL-1
Check MVSL-1 if normal Put HVSL-1 on 3
Resume Traction
12 DJ tripped Via QVSL-2
Check MVSL-2 if normal Put HVSL-2 on 3
Resume Traction
13 DJ tripped Via QVMT-1
Check MVMT-1 if normal Put HVMT-1 on 3
Resume Traction Put corresponding switch on 3, close DJ
14 DJ tripped Via QVMT-2 and check corresponding auxiliary.
Check MVMT-2 if normal Put HVMT-2 on 3
Resume Traction - If auxiliary is working, work the train.
15 Check MVRH if normal Put HVRH on 3 - If auxiliary is not working, isolate the
Resume Traction particular auxiliary and work the train
16 DJ tripped Via QVSI-1 following relevant precautions.
Check MVSI-1 if normal Put HVSI-1 on 3
Resume Traction

Page 71 of 105
17 DJ tripped Via QVSI-2
Check MVSI-2 if normal Put HVSI-2 on 3
Resume Traction
18 DJ tripped Via QPH
Check TFP oil level frequently
Put HPH on 0 & clear block section.
19 DJ tripped due to GR stuck between Bring GR to 0 manually, close DJ and try.
notch If DJ trip again due to GR stuck up then
Bring GR to 0 manually. clear block section by manually control
Clear block section manually. of GR
20 DJ tripped due to Low / No ARNO voltage Inform to LC and ask for relief loco.
21 DJ tripped Via QLA.
Isolate faulty auxiliary machine, if fault
exists make loco dead and inform to TLC. Trouble shoots as per WAG-5 TSD.

22 DJ tripped Via QPDJ Check RS pressure


Start CPA to build up pressure.
23 QVRF not working Do not use DBR.
Do not use Dynamic Braking.

24 ICDJ through QOP-1 Dropped


Put HQOP-1 OFF
On running condition watch HTC

25 ICDJ through QOP-2 Dropped


Put HQOP-2 OFF
On running condition watch HTC
26 ICDJ through QOA Dropped Trouble shoots as per TSD.
Put HQOA on 0
Check auxiliary machines
27 ICDJ through QLM Dropped
Check HT compartment for Oil splashing.
Inform to TLC.
28 ICDJ through QRSI-1 dropped
29 ICDJ through QRSI-2 dropped.
30 ICDJ through QLA dropped
Check ARNO
Inform to TLC
31 ICDJ through QPDJ . Trouble shoots as per WAG-5 TSD.
Check RS pressure / leakage
Start CPA to build up pressure
32 Reverser are neither in ‗F‘ or ‗R‘ Trouble shoots as per WAG-5 TSD.
Set the Reverser manually
Resume traction
33 CTFs are neither in ‗TR‘ nor ‗BR‘ Trouble shoots as per WAG-5 TSD.
Set the CTFs manually on TR side only.
Resume traction.
34 GR not in Zero Bring GR to 0 manually and close DJ
Put GR at 0 manually
Close DJ
35 Brake applied through IP Close IP cut out cock and do not use
Do not use DBR DBR
36 Auto regression Via RGEB Ensure BP pressure is 5 kg/cm2 & RGEB
If not Brake applied check for leakage cock is in open condition.
37 Auto regression Via QD - If auto regression takes place due to

Page 72 of 105
Press BPQD / Resume traction wheel slip, press BPQD and apply
sanders.
- If auto regression takes place due to
traction motor defects, isolate defective
traction motor.
38 Auto regression Via TM over voltage Work the train on lower notches and
Check TM voltage inform to LC
39 Braking Fault SWC Operated Ensure SA-9 is in released & BC gauge
Do not use Loco Brake during RB shows ‗O‘ and do not use RB
40 Working with One CPU Resume traction and inform to TLC.
41 EEPROM Failed Resume traction and inform to TLC.
42 Other CAB display fail Resume traction and inform to TLC.
43 Loco in LT STATUS MESSAGE during LT testing
44 Press BLDJ After energising loco STATUS MESSAGE
Select Pantograph
Press BLRDJ
45 HVMT-1 in Position 0 After isolating MVMT-1, STATUS
L-1, L-2 and L-3 cut off Half power MESSAGE
available
46 HVMT-2 in Position 0 After isolating MVMT-2, STATUS
L-4, L-5 and L-6 cut off Half power MESSAGE
available
47 HVSI-1 in Position 0 After isolating MVSI-1, STATUS
L-1, L-2 and L-3 cut off Half power MESSAGE
available

48 HVSI-2 in Position 0 After isolating MVSI-2, STATUS


L-4, L-5 and L-6 cut off Half power MESSAGE
available
49 Reverser not as per MPJ position Trouble shoots as per WAG-5 TSD
50 CTFs not as per MP position Trouble shoots as per WAG-5 TSD
51 C-145 Open HMCS-1 / 2 not in 1 Do not use RB
Do not use RB
52 DBR Overheating or QF / QE operated Do not use RB
Do not use RB
53 DJ tripped via DJ FB fail Build up RS pressure.
If unsuccessful, inform to TLC / ask for
relief loco
54 Battery charger Out put fail Trouble shoots as per WAG-5 TSD
Check CHBA , Clear block section
55 ICDJ through C-107 Feed back fail Put HBA on 0 and check C-107 is opened
Inform TLC Operate C-107 few times manually and
try to close DJ
If unsuccessful, put HVRH on ‗0‘.close
DJ.
Clear block section and inform to TLC.
56 ICDJ through C-106 Feed back fail Put HBA on 0 and check C-106 is opened
Put HVMT-2 on 0 Operate C-106 few times manually and
Clear section, inform TLC try to close DJ
if unsuccessful put HVMT-2 on 0, clear
block section and inform to TLC.
57 ICDJ through C-105 Feed back fail Put HBA on 0 and check C-105 is opened
Put HVMT-1 on 0 Operate C-105 few times manually and
Clear section, inform TLC try to close DJ.
close DJ if unsuccessful put HVMT-1 on
0, clear block section and inform to TLC.
Page 73 of 105
58 GR stuck up on Notches Bring GR to 0 manually and close DJ
Put GR on 0 manually
59 DJ tripped via C-107 Feed back fail Put HBA on 0 and check C-107 is opened
Inform to TLC fully
Operate C-107 manually few times and
try to close DJ if unsuccessful wedge C-
107
If unsuccessful, inform LC
60 DJ tripped via C-106 Feed back fail Put HBA on 0 and check C-106 is opened
Put HVMT-2 on 0 fully
Clear section and inform to TLC Operate C-106 manually few times and
try to close DJ if unsuccessful wedge C-
106
If unsuccessful, put HVMT-2 on 0, clear
section and inform to LC

61 DJ tripped via C-105 Feed back fail Put HBA on 0 and check C-105 is opened
Put HVMT-1 on 0 fully
Clear section and inform to TLC Operate C-105 manually few times and try
to close DJ if unsuccessful wedge C-105
If unsuccessful, put HVMT-1 on 0, clear
section and inform to LC
62 DJ tripped Via C118 N/C contact fail Check C118 is fully opened.
If unsuccessful, ask for relief loco
63 ARNO not picking up Inform to TLC / ask for relief loco
64 TM voltage channel Noisy Resume traction and inform to LC.
65 V965 voltage channel noisy Resume traction and inform to LC.
66 ARNO voltage channel noisy Resume traction and inform to LC.
67 User changed configuration / Loco No. Resume traction. STATUS MESSAGE
68 Communication Link Display in Cab-2 fail Resume traction and inform to LC
69 Communication Link Display in Cab-1 fail Resume traction and inform to LC
70 RTC Fail Resume traction and inform to LC
71 V 965 Channel fail Inform to LC / Ask for relief loco
72 ARNO channel fail Inform to LC / Ask for relief loco
73 TM voltage channel fail Q-20 will not energise, work the train by
observing Voltmeter and inform to LC.
74 Auto – regression via ACP Reset ACP and work the train
75 BPAR put in bypass After putting HPAR on 0, STATUS
MESSAGE
76 BPAR restored After putting HPAR on 1, STATUS
MESSAGE

TROUBLE SHOOTING FOR MICROPROCESSOR LOCO DESIGNED BY STESALIT (FDCS-9648)


Duties of Loco Pilot when DJ/VCB trips

Sr.
No. Display panel / Message on screen Duties of Loco Pilot
1 C-118 N/C Contact Fail Check C-118 is opened fully
2 C-118 Stuck Up Release BLRDJ and check C-118 is opened fully.
3 OHE not available when DJ closed Trouble shoots as per WAG-5 TSD
4 No OHE when Loco Running Trouble shoots as per WAG-5 TSD
5 DJ tripped via QOP-1 Trouble shoots as per WAG-5 TSD
6 DJ tripped via QOP-2 Trouble shoots as per WAG-5 TSD
7 DJ tripped via QOA Trouble shoots as per WAG-5 TSD

Page 74 of 105
8 DJ tripped via QRSI-1 Trouble shoots as per WAG-5 TSD
9 DJ tripped via QRSI-2 Trouble shoots as per WAG-5 TSD
10 DJ tripped via QLM Trouble shoots as per WAG-5 TSD
11 DJ tripped via QVSL-1 Put corresponding switch on position 3, close DJ
12 DJ tripped via QVSL-2 and frequently check proper working of auxiliary.
13 DJ tripped via QVMT-1 - If auxiliary is working, work the train.
14 DJ tripped via QVMT-2
- If auxiliary is not working, isolate the
15 DJ tripped via QVRH
16 DJ tripped via QVSI-1 corresponding auxiliary and work the train by
17 DJ tripped via QVSI-2 taking precautions.
18 DJ tripped via QPH

19 DJ tripped due to GR Stuck Between Bring GR to ‗0‘ manually, close DJ and clear block
Notch section by manual control of GR.
20 DJ tripped due to Low or No ARNO Inform to TLC / Ask for relief loco.
Voltage.
21 DJ Tripped via QLA Trouble shoots as per WAG-5 TSD
22 DJ Tripped via QPDJ Check RS pressure, if less build up pressure by
MCPA
23 DJ Tripped via QVRF Do not use DBR
24 ICDJ due to QOP-1 Dropped Trouble shoots as per WAG-5 TSD
25 ICDJ due to QOP-2 Dropped Trouble shoots as per WAG-5 TSD
26 ICDJ due to QOA Dropped Trouble shoots as per WAG-5 TSD
27 ICDJ due to QLM Dropped Trouble shoots as per WAG-5 TSD
28 ICDJ due to QRSI-1 Dropped Trouble shoots as per WAG-5 TSD
29 ICDJ due to QRSI-2 Dropped Trouble shoots as per WAG-5 TSD
30 ICDJ due to QLA Dropped Trouble shoots as per WAG-5 TSD
31 ICDJ due to QPDJ Dropped Trouble shoots as per WAG-5 TSD
32 Reverses are Neither in ‗F‘ nor in ‗R‘ Trouble shoots as per WAG-5 TSD
33 CTFs are Neither in ‗TR‘ Nor in ‗BR‘ Trouble shoots as per WAG-5 TSD
34 GR Not in Zero Bring GR to ‗0‘ manually and close DJ
35 Brake Applied Through ‗IP‘ Close ‗IP‘ cut out cock. Do not use DBR
36 Auto Regression Via RGEB Ensure BP pressure is 5 kg/cm2 & RGEB cock
open
37 Auto Regression Via QD - If auto regression takes place due to wheel slip,
press BPQD and apply sanders.
- If auto regression takes place due to TM
defective, isolate defective traction motor and
work the train.
38 Auto Regression Via TM Over Work the train on lower notches and inform to
Voltage TLC.
39 Braking Fault. SWC Operated Ensure SA-9 is in release position and do not use
DBR
40 Working with one CPU Inform to LC
41 System Error Resume traction and inform to LC
42 Other Cab display fail Resume traction and inform to LC
43 Loco in LT During LT Testing STATUS MESSAGE
44 Auto Regression Via ACP Reset ACP
45 HVMT-1 in Position 0 While isolating MVMT-1 STATUS MESSAGE
46 HVMT-1 in Position 2 While putting HVMT-1 on position ‗2‘ STATUS
MESSAGE
47 HVMT-2 in Position 0 While isolating MVMT-2 STATUS MESSAGE
48 HVMT-2 in Position 2 While putting HVMT-2 on position ‗2‘ STATUS
MESSAGE
49 HVSI-1 in Position 0 While isolating MVSI-1 STATUS MESSAGE
Page 75 of 105
50 HVSI-1 in Position 2 While putting HVSI-1 on position ‗2‘ STATUS
MESSAGE
51 HVSI-2 in Position 0 While isolating MVSI-2 STATUS MESSAGE
52 HVSI-2 in Position 2 While putting HVSI-2 on position ‗2‘ STATUS
MESSAGE
53 Reversers Are Not as per MPJ Trouble shoots as per WAG-5 TSD
position
54 CTFs Are Not as per MP position Trouble shoots as per WAG-5 TSD
55 C 145 Open HMCS-1 & 2 Not in ‗1‘ Do not use RB
56 C 145 Open DBR overheated Do not use RB

57 Auto Regression Via QF/QE Do not use DBR


58 Battery Charger Output Fail Trouble shoots as per WAG-5 TSD
59 J Forward Feedback Fail Manually operate J-1, J-2 few times
60 J Reverse Feedback Fail Manually operate J-1, J-2 few times
61 CTF Traction Feedback Fail Manually operate CTF-1, 2 & 3 few times and put
on Traction side
62 CTF Brake Feedback Fail Manually operate CTF-1, 2 & 3 few times and put
on Traction sideDo not use DBR
63 ICDJ through C-107 Feedback fail Put HBA on ‗0‘ and check C-107 is opened.
Manually operate C-107 few times and try to close DJ if
unsuccessful put HVRH on III and try.
If unsuccessful, inform to LC
64 ICDJ through C-106 Feedback fail Put HBA on 0 and check C-106 is opened.
Manually operate C-106 few times and try to close
DJ
If unsuccessful, HVMT-2 on ‗0‘, clear section and
inform to LC
65 ICDJ through C-105 Feedback fail Put HBA on ‗0‘ and check C-105 is opened.
Manually operate C-105 few times and try to close
DJ.
If unsuccessful, HVMT-1 on ‗0‘, clear section and
inform to LC
66 DJ tripped via DJ Feed Back fail Check RS pressure.
If unsuccessful, inform to LC / Ask for relief loco.
67 DJ Feedback found close before DJ Inform to LC / Ask for relief loco.
is closed
68 Auto Regression via DBR pressure Do not use DBR
switch
69 ICDJ due to Q-44 operated Inform to LC / Ask for relief loco.
70 BRLDJ released before C-118 is Press BLRDJ 3-4 seconds
energised
71 ICDJ due to feedback failed Inform to LC / Ask for relief loco.
72 DJ tripped due to GR stuck on Bring GR to ‗0‘ manually, close DJ and clear
Notches block section by manual control of GR
73 Auto regression via Q-50 Clear block section by manual control of GR and
inform to LC

NOTE
If any fault message comes on display unit, trouble shoot as per fault message. If trouble is not
rectified, before asking relief loco, Loco Pilot do as follows:
1. Put HOBA in OFF and try to rectify the trouble.
2. Switch off Battery for 3 minutes and try to rectify the trouble.
3. Drain out full MR/RS pressure & rebuild the pressure and try.
Page 76 of 105
MPCS VERSION-3
BLOCK DIAGRAM:-

DISPLAY SCREEN:

Page 77 of 105
OBJECTIVES OF MPCS VERSION -3

1.10.4 INCH TFT DISPLAY.

2 . VCD INBUILT.

3. SPEED RECORDER INBUILT.

4. ENERGY METER INBUILT.

5 . NOTCH REPEATER INBUILT.

6 . ISOLATION OF VCD BY SOFTWARE.

7 .Q118 ,QCON ,Q50 ,QCVAR RELAY WEDGING BY SOFTWARE FACILITY IS


PROVIDED.

8. BPMPR push button provided on MAIN UNIT to reset the MPCS in case of
‗INTERNAL FAULT‖ message display.

Introduction:

The Display Unit of MCS system locomotives is HMI unit through which the user can
interact with the system. It has numeric keyboard through which user interacts with the
system. It gets the information requested by user from the control system through the
serial communication Interface and display it on the Display.
Display module provides user with the necessary data of what exactly going on within
the system. It has a MENU driven operation that makes it user friendly. The display Unit
serves the following functions :

● Viewing of operational status of locomotives.


● Crew announcements, wherever pilot information / intervention is required.
● Viewing of fault log information.
● System configuration settings modifications.
● Vigilance test modes interface.
● Isolation Status.
● Viewing of digital input, digital output and analog parameters.
● Train configuration information.
● Software versions of the sub modules of the system.

Page 78 of 105
● The input keypad is split on two sides of the LCD Display screen. The buttons on
the right of the screen have fixed functions like, brightness control, automatic brightness
control, contrast control, Display ON / OFF, Faults and Menu.
● The buttons on the right hand side of the display screen are four direction arrows
for navigation, Enter and Cancel keys.
● Twenty keys are provided on the display unit
1. Right Key Pad - 10 Keys
2. Bottom Key Pad - 10 Keys

Bottom keys:
There are 10 keys at the bottom of the display. The 10 context sensitive keys acts as
soft keys and their function changes as per the content that is displayedon the screen.
S. no Key Description
1. 1. MAIN MENU
2. 2 CREW MESSAGE
3. 3 LP INFORMATION
4. 4 LOCO STATUS
5. 5 ISOLATION
6. 6 SETTINGS
7 7 Q50 BYPASS
8. 8 QCON BYPASS
9. 9 QCVAR BYPASS
10. 0 Q118 BYPASS

LAMPS PROVIDED ON DISPLAY UNIT—


1. BPFA – Self illuminated push button for FAULT ACKNOWLDGEMENT.
2. LSFI -- Fault indication lamp.
3. LSVW – Vigilance warning lamp.

Page 79 of 105
● Whenever crew occur, BPFA and LSFI lamps glow. Pressing illuminated
push button (BPFA) is taken as acknowledgment by the system for the
crew that is shown on the display screen, after acknowledgment by the
user the lamps become OFF.
● Whenever VCD Warning cycle is started, then LSVW glows.

Main screen / Default screen :


In this default screen section 1, Loco number, Date and Time, Isolation Status of VCD,
HMCS,HVRH,HVMT and HPAR/ Wedging status of relay Q50,QCON,QCVAR ,Q118

and Notch is displayed.


This default screen section 1 is common to most of the screens. TFT displays
the working Cab status i.e., CAB1 Active or CAB2 Active status. In Crew
Messages information, Display shows the status of BL key, Pantograph,
BLRDJ, BLDJ, MP and MPJ position. From this screen, user can go to main
menu and crew messages by selecting the number keys.

Page 80 of 105
VIGILANCE CONTROL DEVICE-

1. The VCD unit is inbuilt in DISPLAY UNIT.


2. If LOCO PILOT will not acknowledge VCD for a period of 60 sec‘s LSVW lamp
provided on DISPLAY UNIT ill glow for 8 sec‘s.
3. If LP not acknowledge BUZZER will sound after 8 sec‘s.
4. If till not acknowledge penalty brake will apply.

5. FAULT DIAGNOSTICS
There are three types of diagnostic messages, which are displayed from loco
crew on the respective CAB display unit.

1. Fault Messages
● Faults are grouped as per sub system. Each fault message is assigned
to either priority 1 or priority 2 level.
● Priority 1 messages are related to DJ tripping, total loss of tractive effort,
vigilance control and system related.
● Priority 2 messages are the remaining messages which are not related to
priority 1 level.
2. Isolation Messages
Isolation messages provide the information about the sub system isolation
status.
3. Information Messages
Information messages provide information to the loco pilot about the
status of the loco operation.

Page 81 of 105
INCASE FAULTS DISPLAY-
1. If any fault comes shows on DISPLAY SCREEN.

2. Buzzer will sound.

3. LSFI and BPFA provided on Display screen will glow.

4.The fault displays with corresponding diagnostic data code,with date, time & TSD that
is instructions to trouble shoot the same.

5. LP should read and note the fault message and trouble shoot as per instruction
display. Then press BPFA to acknowledge the fault.

6. After that BUZZER will stop.

7. To check the fault messages LP should select ‗ VECHICLE DIAGNOSTIC ― option


from‘ MAIN MENU and then select sub menu‘ DIAGNOSTIC DATA‘.

8. Then fault data display screen shows all the faults which are logged in the memory
with‘ TSD‘.

9. Then LP should select TSD. After that information about TSD is displayed with
diagnostic code.

Page 82 of 105
Page 83 of 105
L1 & L2 LED LAMP.
1. These LED lamps are provided on the bottom of DISPLAY SCREEN & on the
left side of the SOFT KEYS.
2. If there is any short circuit of contactors C101/C102/C103/C105/C106/C107 the
circuit breakers DOP1/DOP4 provided on the CPU (on main unit) will be tripped
and L1 & L2 LED lamp will flashing on DDS.
3. WHAT TO DO—LOCO PILOT should open the cover of MAIN UNIT & RESET
the circuit breaker DOP1/DOP4 once.
4. This feature not provided on FDCS VERSION 1/2.

Page 84 of 105
RELAY BYPASS
1 .If there is any fault occurs due to problem in relay Q50/QCON/QCVAR/Q118
message will display on the DDS screen with yellow arrow mark appears above the
corresponding soft key 7/8/9/0 accordingly and the soft key is becomes active.

2. Then corresponding soft key to be press.

3. After pressing the soft key the corresponding relay screen comes and
BYPASS/ACTIVE information is also given in the conformation screen.

4. After pressing the soft key following options comes on display screen for loco pilot-

a) For instantaneous bypass press key -―1‖.

b) For permanent wedging of the relay press soft key -―2‖.

c) To cancel press key –―3‖

5. Display shows bypass with red arrow mark in the screen for bypassing and active for
removing bypass.

6. This wedging status shall be considered only until the relay is faulty. Once the relay
is healthy ,the relay functions normal automatically & Corresponding relay wedging
shall be removed by the system.

Page 85 of 105
Page 86 of 105
IF DJ TRIPPED & INTERNAL FAULT MESSAGE OF MPCS SHOWS ON DISPLAY.--
--

1 .ACK the fault and try to reclose DJ. If successes resume traction.
2. If not success ,open the door of the MAIN UNIT/CPU and reset MPCS
SYSTEM by pressing the push button ‖BPMPR‖ located on MAIN UNIT/CPU of
MPCS.
3.,Press push button for 5 SEC‘S and release ,then reclose DJ. If success
resume traction.
4. In case FAULT persists call for relief loco.

Page 87 of 105
STATIC INVERTOR LOCO

NEW ITEMS FITTED AND THEIR FUNCTIONS


REMOVED ITEMS ITEMS FUNCTION
C-118, R-118, QOA, CCINV 6 amps fuse for converter control circuit
HQOA, Q100, QTD-
Q-CON PC-8 relay on Q-118 circuit for trip indication of STC
105, QTD-106,
QCVAR, HQCVAR. Q-SIT PC-8 relay on Q-44 circuit (in lieu of QCVAR)
LSSIT Fault indication lamp on driving desk- glows along
with external and internal fault.
QTD-101 For 5 second delay to start compressor.
QSVM For 2 second delay to start STC during BLVMT ‗ON‘
HSIV Earth fault by-passing switch for auxiliaries.
HRAVT Isolation switch for cab heater, cab fan, notch
repeater, charger for walkie-talkie.
ELD Auxiliary earth fault by-pass re-setting switch.
C108 Contactor for 3 phase AC MVRF.

IMPORTANT INSTRUCTIONS FOR SIV FITTED LOCO


CHECKING OPERATION IN CASE OF TRIPPING FAILURE.
1.. In case of tripping on line, Bring MP to ―0‖,wait 15 second for LSGR to glow .If
LSGR not glow then bring GR to ―0‖ manually .If LSGR glow then check PANTO
and OHE. If any abnormality found then lower the PANTO ,stop the train, comply
with GR 6.03.If no abnormality found then check safety relay targets ,If relay
targets show red/locked follow trouble shooting of safety relays. In case of
tripping failure always check relay QSIT/LSSIT lamp along with safety relays after
every tripping during the course of trouble shooting.
b) In case of tripping with QSIT drop LSSIT lamp glow; it means trouble is in SIV.
Then check the fault code / fault message displayed on the VFD and trouble
shooting to be done accordingly.(Either INTERNAL FAULT or EXTERNAL
FAULT.)
c) In case of tripping with any fault indication lamp on its panel, LP to note down
the text message displayed on the LCD/VFD, before trouble shooting. The
same message to be followed & conveyed to TLC, if required.
2.If no relay target dropped and QSIT not energies and LSSIT not glow then pick up
abnormal sign as per ARNO loco. During the course of trouble shooting count the
time/pick up abnormal sign only after extinguishing LSCHBA (i.e. after SIV picked
up)
3. HSIV to be put on ‗0‘ in case of external fault in auxiliary circuit only when:-
a) Locomotive is stuck up in block section and to work the train up to next station
maximum up to 45 minutes.
b)If It is not possible to identify and isolate the fault circuit.
c) Earth fault message displayed on SIV PANEL.
4. During MU operation if one loco is ARNO fitted and other is SIV fitted, then the
loco pilot should :-

Page 88 of 105
i) Release the BLRDJ switch as per the practice being followed in the case of
ARNO fitted loco, irrespective of one or the other loco is fitted with ARNO or
SIV.
ii) Take initial ‗6‘ traction notches slowly enough after closing of DJ to ensure that
in event of the rear loco being fitted with SIV , it does not trip through air flow
relay as the blowers take little time to start in SIV loco.
5. During ICDJ trouble shooting in SIV loco: loco pilot to check Q44 instead of C118
for recognizing the electrical /pneumatic failure as there is no provision of C118 in SIV
loco.

4.OPERATIONS OF DIFFERENT MAKES STC LOCOS:

(A) RESET:

(i) Press ‗RESET‘ push button on STC


body if provided or

(ii) Keep HBA on ‗0‘ for 3 minutes to


reset SIV.

(B) ELD By-pass:

(i) Put HSIV in ‗0‘ position.

(ii) Press ELD push button till earth


fault by-pass lamp glows and external
fault extinguish.

(C) To find fault data: On pressing


‗MODE‘ button it will show:

(i) On time mode

(ii) Failure mode


HIRECT/HIND RECTIFIER
Then press SET button, fault message
appears on screen by UP & DN cursor.

Page 89 of 105
(A) RESET: To reset SIV press OK
push button provided on SIV panel till
the RED fault lamp on SIV goes off and
LSSIIT is extinguished.

(B) ELD By-pass:

(i) If external fault RED lamp glows in


SIV and if SIV display shows ‗Earth
fault‘.

(ii) Reset SIV by pressing ‗OK‘ push


button on SIV display till the RED
lamp on SIV goes off. SIV is reset
only if the RED lamp is OFF.

(iii) Press Earth fault by-pass switch


near SIV display.

(iv) Close DJ and SIV will start in Earth


fault by-pass mode.

Note: HRAVT & HSIV switch not


provided.

(C) To find fault data: To see SIV fault


ABB history press or arrow key
provided on display unit.

(A) RESET: Press ‗Reset‘ button


provided on SIV panel till LSSIIT is
extinguished.

(B) ELD By-pass:

(i) Put HSIV on ‗0‘ position.


(ii) Press ELD By-pass button till ELD
By-pass lamp glows and external
lamp extinguished on STC body.

(C) To find fault data:

(i) First time press ‗SEL‘ button to find


parameters of the loco.

(ii) Press ‗SEL‘ twice, then press UP or


DN cursor to find fault.

SIEMENS

Page 90 of 105
A) RESET: Press ‗RESET‘ button on
STC body.
(B) ELD By-pass: Press ‗ENT‘ button
by-pass active message display and
ELD by-pass lamp glows on STC body.
Note: HRAVT & HSIV switch not
provided.
(C) To find fault data:
(i) Press-1 to view voltage, current, BA
voltage, Frequency & CHBA voltage
etc.
(ii) Press-2 fault data enquiry fault
Then press UP & DN cursor to find
current fault.

BOMBARDIER

(A) RESET: Press ‗RESET‘ button


provided on SIV panel till LSSIIT is
extinguished.
(B) ELD By-pass:
(i) Put HSIV in ‗0‘ position.
(ii) Press ELD By-pass button till
earth by pass lamp glows and
external fault lamp extinguished.
(C) To find fault data: Press UP &
DN cursor at a time for 5 Seconds
fault will appears on screen, then
press UP or DN cursor to find fault.
MEDHA
(A) RESET:
(i) Press ‗RESET‘ button if
provided. OR
(ii) Keep HBA on ‗0‘ for three
minutes to reset ‗SIV‘.
(B) ELD By-pass:
(i) Put HSIV on ‗0‘ position.
(ii) Press the ELD by-pass switch
provided on display panel of
converter till ELD by- pass
lamp glows and external lamp
extinguished on STC body.
(C) To find fault data: In DDS of
STC press MEMU button two times
then press ‗SET‘ button fault data
AAL (Autometre Alliance) can be seen by UP or DN cursor.

Page 91 of 105
TRIPPING THROUGH RELAY QSIT ( LSSIT GLOW)-IN SIV FITTED LOCO.
CHECK SIV PANEL FOR FAULT INDICATION---
1. IF INTERNAL FAULT INDICATION LAMP GLOWING ON SIV PANEL:
Check for any smoke, fire and burning smell from SIV and also message on display
screen.
If FAN fault message displaying:-
 Reset the Fan MCB if provided, reset SIV ,close DJ and resume traction.
 If MCB not resetting ask for relief loco.
 If MCB not provided, press ‗RESET‘ push button.
 If not success, close IP valve, put HBA from ‗ON‘ to ‗OFF‘ and to ‗ON‘.
 If successful, open IP valve and resume traction.
 If not success ask for relief loco.
If OVER TEMPRATURE fault message displaying:-
 Wait for 10 minute, then Reset SIV ‗RESET‘ button and then close DJ
 If fault clear and DJ holds resume traction.
 If fault comes again, close IP valve, put HBA from ‗ON‘ to ‗OFF‘ and to ‗ON‘. Then
close DJ.
 If successful (DJ holds) open IP valve and resume traction.
 If not success, ask for relief loco.
If fault displaying Except Fan/Over temp. Fault message:-
 Press SIV ‗RESET‘ push button. Close DJ
 If fault clear and DJ holds resume traction.
If same fault comes again close IP valve, put HBA from ‗ON‘ to ‗OFF‘ and to ‗ON
‘&.close DJ
 If successful, (DJ HOLDS) open IP valve and resume traction.
If still not succeeded, isolate loads one by one and try.
 If not success, ask for relief loco.
2, EXTERNAL FAULT INDICATION ON SIV PANEL:

Check for any smoke, fire and burning smell from SIV, all auxiliary motors, contactor
panel,switch board and also ensure all contactors are open and check the message on
display screen. If any abnormality noticed: use fire extinguisher and isolate the same, reset
SIV close DJ resume traction and clear block section as per STANDARD INSTRUCTION.
A). If no abnormality but, ‗EARTH FAULT‘ message is displayed & loco is on block
section:-
 Press Reset button
 Put HSIV on ‗0‘.
 Press earth fault/ELD bypass button. Close DJ.
 Work up to 45 min. And clear block section.

Page 92 of 105
On arrival at station put HSIV on ‗1‘and trouble shoot as per‖ other than earth fault
message.
B). OTHER THAN‗EARTH FAULT‘ message displayed:-
 Remove CCSPM fuse if provided. Trip AC MCB if provided.
 Put HRAVT on ‗0‘ position.(If HRAVT not provided remove CCRA1&2,open
BLRA1&2, remove CCVT fuse).Reset SIV close DJ.
 If successful (DJ holds), resume traction.
 If not success (same fault comes again), Open BLCPA and BLVMT, reset SIV try to
close DJ.
IF DJ HOLDS WITH BLCPA & BLVMT OPEN:-
 Close BLVMT only.
 IF DJ TRIPS with same fault message: Put HVRH, HVMT-1 & HVMT-2 on ‗0‘
one by one ,reset SIV and close DJ.
 IF DJ HOLDS after putting any of the switches on ‗0‘ work as per standard
instruction.
IF DJ HOLDS WITH BLVMT CLOSED:-
 Close BLCPA.
 IF DJ TRIPS with same fault message : Change the position of ZCP/HCP reset
SIV close DJ .If DJ holds keep HCP/ZCP on that position where DJ holds.
IF DJ TRIPS WITH SAME FAULT WITH BLCPA & BLVMT OPEN:-
 Put HVSI-1, HVSI-2, HVSL-1, HVSL-2 and HPH on ‗0‘ one by one reset SIV and
close DJ.
 IF DJ HOLDS after putting any switches on ‗0‘, work as per standard instruction.
IF UNSUCCESSFUL OR FAULTS NOT TRACEABLE IN BLOCK SECTION:-
 Put HSIV on ‗0‘.
 Press earth fault/ELD bypass button ,close DJ and
 Work up to 45 min. And clear block section.

3. DJ CLOSE BUT SIV DOES NOT START WITHOUT ANY INDICATION ON SIV
PANEL (LSDJ extinguish, UA will deviate but LSCHBA will not extinguish,
Auxiliaries sound will not come):-
 Check OHE voltage if in between 16.5 KV to 31 KV.
 If OHE voltage is normal, Check CCINV fuse – If melted – Replace CCINV.
 If melts again put HOBA ‗OFF‘ in all loco/locos in case of MU/Consist – Renew
the fuse and try.
 If unsuccessful – Request for assistance.
 IF CCINV GOOD: Close BLVMT first then close DJ .
 If unsuccessful – Put HBA on ‗0‘, wait for 2 sec. and try again.
 If unsuccessful – Put HOBA ―OFF‖ and try again.
If not successful -- Isolate loads one by one and try.

Page 93 of 105
This trouble may be due to over temperature. So, wait for 10 minutes and try again
to close DJ/VCB. If trouble not rectified, after that ask for assistance loco.

4. SIV FAILS TO START WITH indication lamp glowing “Input voltage out of range /
Input voltage in range”on SIV PANEL.

After closing VCB if LSCHBA not extinguish and auxiliary sound is not coming.
Check SIV panel. If lamp indication of ―Input voltage out of range/ Input voltage in
range‖ is glowing,

Check the OHE voltage in between 16.5kv - 31kv in UA meter and in


speedometer:-
i) If OHE voltage is not in the range, contact with TLC/TPC & wait for normalization
of OHE voltage.

ii) If OHE voltage within range but still unsuccessful, close IP cock, put HBA on ―0‖
wait for 2 sec. and put back to ―1‖ & try again.
Indication for input voltage on various make SIV:

Sl SIV Make LED indication name LED Status (Red)


no.
1 HIRECT INPUT VOLTAGE IN When voltage not in range it will
RANGE glow
2 MEDHA INPUT VOLTAGE IN When voltage not in range it will
RANGE glow
3 SIEMENS INPUT VOLTAGE IN When voltage not in range it will
RANGE glow
4 BOMBARDIER VOLTAGE OUT OF When voltage not in range it will
RANGE glow

Page 94 of 105
5 ABB IP VOLTAGE NOT IN When voltage not in range it will
RANGE glow
6 AAL INPUT VOLTAGE OUT When voltage not in range it will
OF RANGE glow
(**)

** In AAL make SIV after HBA ‗ON‘ to till VCB close Input voltage out of range led will
glow.
CONTROL CIRCUIT OF
BLOWER CONTACTORS (STC)

CCA (6A) DJ
CCINV (6A)

BLVMT 1 BLVMT 2
QSVM QSVM

QV60 R B
R

01 2 3 01 2 3 012
S 3
QSVM 2SEC

TS
C HVRH HVMT-1 HVMT-2
C107 C105 C106

5.SIV FAILS TO RE-START AFTER CLOSING BLVMT:


After closing BLVMT ,SIV will ―OFF‖,LSCHBA glows and Auxiliaries sound
stop BUT after 10 to 12 seconds SIV not restart ,LSCHBA not extinguish
and no auxaliries sound comes.
 Check CCINV and CCA fuse (both locos in case of MU) and replace if melted.

 If both fuses are good, check QSVM relay in DJ close condition after closing BLVMT..
If not energized, wedge QSVM in energize condition. Close BLVMT before closing
DJ/VCB, if SIV will start along with all blowers resume traction..

 If QSVM is in energies condition and still SIV fails to start then try by wedging QSVM
In de-energies condition, put BLVMT ‗ON‘ before closing DJ.

 If unsuccessful – Put HBA on ―0‖ for few seconds and again put on normal and try.

 If still trouble persist request for assistance.

Page 95 of 105
NOTE : During trouble shooting following should be ensured:-
1. Whenever HSIV kept on ‗0‘ and ELD bypass check the auxiliaries and SIV for any
smoke or fire in every 15 minutes.

2. After every tripping due to fault in SIV troubleshoot as per procedure, reset the
SIV then close DJ.

3. If it is required to put HBA on ‗0‘ for resetting the SIV / MPCS, isolate the ‗IP‘
isolating cock first. Again put on service after putting HBA on ‗1‘.

4. .Whenever tripping on line, check LSSIT lamp, if glowing then check QSIT relay
along with safety relay targets. If QSIT found energize and no safety relay
dropped then check the SIV panel for Internal/External fault lamp glowing. If
Internal/External lamp glowing troubleshoot for the same observing fault
messages in SIV display.
5. If no safety relay drop and QSIT not energies pick up checking sign as per
ARNO loco.

6. While pick up checking sign for Operation- ‗B‘ & ‗O‘, always count 15 sec after
extinguishing Of lamp LSCHBA .

7.For Operation- ‗I‘ & ‗II‘, take traction notch after extinguishing of lamp LSCHBA
.

Page 96 of 105
IN CASE ICDJ IN SIV FITTED LOCO :

Trouble shoot as per ARNO loco- (Check Q44 instead of C118/S118)


In addition to trouble shooting of ARNO loco following trouble shooting also to be
done:
Probable defects/ Action to be taken by the Loco Pilot.
Observation/checking
LSDJ remains glowing Ensure BLDJ is closed,
after closing BLDJ and LSGR glowing and
pressing BLRDJ. ZPT is in other than ‗O‘ position.
Ensure LSSIT is not glowing/QSIT is not energized.
a) If LSSIT/QSIT not energized-Trouble shoot as
ARNO LOCO
b) If unsuccessful-put HQOP 1& 2 in OFF position
reset SIV and close DJ.
c) If unsuccessful – put HOBA OFF- Reset SIV &
close DJ.
d) IF unsuccessful – Put HBA on ―0‖ for few seconds
and put on ―1‖ and close DJ.
e) If unsuccessful- Request for assistance

If LSSIT is glowing/QSIT is check SIV panel and do the trouble shooting as per
energized. lamp indication.

IN CASE OF NO TENSION CHECKING SIGN---Close BLDJ,Press BLRDJ,


LSDJ goes out UA not deviate release BLRDJ not waiting for LSDJ to glow.LSDJ will
glows after releasing BLRDJ. Refer trouble shooting of ARNO loco.

Page 97 of 105
WHILE CLOSING DJ IF LSDJ GOES OUT, UA deviates, release BLRDJ,
if LSDJ GLOWS AGAIN BEFORE LSCHBA GOES OUT in SIV FITTED
LOCO OPERATION—A
―FOR SINGLE UNIT‖

Probable defect Action to be taken by the Loco Pilot.


observation/checking
 Close BLDJ, Close BLVMT, Press
BLRDJ, LSDJ goes out UA deviate&
Q3O or its N/O interlock /GR on ―0‖ Release BLRDJ after LSCHBA
interlock on Q44 branch defective. extinguish –if DJ holds resume traction.
 If DJ trips before releasing BLRDJ-Close
DJ by manual operation of Q118.
 If DJ trips after Releasing BLRDJ-
Request for assistance.
―FOR MULTI UNIT‖
 Troubles shoot as per SU for leading
loco.
 Ensure from leading loco: Pantograph
of trailing loco is touching the contact
wire.
 Proceed to the trailing loco. Do the
same operation on trailing loco as given
for SU or leading loco in MU/Consist.

Page 98 of 105
OPERATION-B
In SIV Fitted loco while pick up checking sign in case LSDJ goes out, UA
deviates release BLRDJ- Count 15 Sec after LSCHBA extinguish – If LSDJ
glows again check safety relays and QSIT/LSSIT, if all are normal that is
tripping in operation-B.
Probable defect Action to be taken by the Loco Pilot.
observation/checking
1.MPH/QPH,MVSL1/QVSL1,  Close BLVMT first and then check for
MVSL2/QVSL2 operation –B tripping again-
2 .N/C interlock of C105/C106/C107  If DJ holds-resume traction (always
on Q118 branch. close BLVMT before Closing DJ.
 IF DJ TRIPS- Put HPH, HVSL-1 and
HVSL-2 on position III after operating
the switches a few times
 Close DJ and count 15 sec.

IF DJ HOLDS/ TRIPS Refer ARNO loco trouble shooting for OP-B


Tripping.

OPERATION--O
If there is no tripping up to operation-B,close BLVMT and wait till
LSCHBA extinguish ,if DJ trips within 15 sec‘s check safety relays
and QSIT/LSSIT,if all are normal it is operation –O.
TROUBLE SHOOT AS PER ARNO LOCO.
OPERATION—1
If there is no tripping up to operation-O, take one traction notch and
,if DJ trips within 15 sec‘s check safety relays and QSIT/LSSIT,
if all are normal it is tripping in operation-1.
TROUBLE SHOOT as per ARNO loco.
NOTE- -Always take traction notch after LSCHBA extinguish
OPERATION-II--
If there is no tripping up to operation-I ,take six traction
notches, if DJ trips within 15 sec‘s ,check safety relays, QSIT/LSSIT if
all are normal it is tripping in operation –II.
TROUBLE SHOOTING-----
1. Ensure switches HVRH,HVMT-I and HVMT-2 should be in 1 or 3.
2. Close DJ close BLVMT and check contactor C105, C106 & C107are
In close position.
3. If C107 not closing first ensure that CTF‘S are in TR position.
4. If any contactor not closing clamp the contactor and try.
5. If contactors are closing trouble shoot as per ARNO loco.
6. Remember that HC105 is not provided in SIV fitted locos.
NOTE-After wedging blower contactors no need to operate Q118 manually
to close DJ.
Position of HRAVT switch:-
HRAVT Cab heater Cab fan Notch repeater Charger
position
0 Isolated Isolated Isolated Isolated
1 Working Working Working Working
2 Isolated Working Working Working
3 Isolated Isolated Working Isolated

Page 99 of 105
110V DC
CCA (6A) BLOWERS CONTROL CIRCUIT (STC)
+ VE
GR CL QVRF
0-5

DJ
CTF1
(BR)

CTF2
(BR)

CTF3
(BR)

BLVMT 1 BLVMT 2 HMCS 1

HMCS 2

CTF 1 (TR)

HVRH HVMT 1 HVMT 2

C107

2Sec

BA -VE
QSVM C107 C105 C106 C145 C108 LSDBR

COMPRESSORS CONTROL CIRCUIT (STC)


CCA (6A)
+110V

QCON

F R F R
MPJ
FROM
CCPT 1 2
1 2 1 2 (005) CTF1
BLCP BLCPD CL ON BR CCLSA
(6A)
C 101 PVEF1 PVEF2
RGCP
CUT IN 8 Kg/Cm² CTF2
CUT OUT 9.5Kg/Cm² C 102 CL ON BR
Q 119
QTD101 5Sec
5Sec C 103
Q119 HCP
5Sec CTF3
3
CL ON BR

1/2/3 1/3 1/2 1 1/2/3 3/2 1/2 2 1/2/3 2/3 1/3 3

HCP HCP HCP


QV64

QRS2
406 407 408 629 421
400
5Sec 5 sec

B-VE
1 2 3
VEAD QTD101 C 101 C 102 C 103 Q 119 VEF( E )
VEUL S

Page 100 of 105


PRECAUTIONS ON RELAY WEDGING
Q50
1. Ensure correct position of ‗J1‘and ―J2‖ as per position of MPJ, CTF1,2,3 are in
―TR‖ side and C145 fully open.
2. Wedge in energised condition.
3. Do not operate ‗MPJ‘-If operated. After Cab changing physically ensure correct
position of ‗J1‘and ―J2‖.
4. Do not use RB.
5. If DJ tripped on notches, or during NO TENSION bring ‗MP‘ to ‗0‘.
Q51
1. If required wedge in de-energised position.( in case of MU/Consist in all locos)
2. Auto regression will not take place by the action of QD, Q20, QRS or PR2.
3. If LSP glowing due to wheel slipping – regress notches to avoid wheel skidding or
rail burnt.
4. Observe BP level- if drops or dropped by A9 - bring ‗MP‘ to ‗0‘.
QRS
Before checking QRS, Ensure – i) BL is unlocked ii) BP pressure 5kg/cm2
iii) RGEB COC is open.
1. If required wedge in energized position ( in case of MU/Consist in all locos)
2. If BP pressure dropped abnormally or dropped by A9/RS – bring MP to ‗‗0‘.
Q100
To be checked after DJ closing.
1. If required wedge in energized position (in case of CCA good but still it is de-
energized )
2. If required wedge in de- energized position (in case of CCA melts even after HOBA
‗OFF‘ or after closing BLVMT in MU loco.)
3. In case wedged Q100 in energized condition open all auxiliary switches before
closing DJ, close one by one giving time gap to avoid over loading on ARNO.
4. If after wedging found ICDJ, ensure MPJ on ―0‘‘ – try to close DJ.
5. If still found ICDJ – Put HBA on ‗0‘ and then on 1 close DJ.
Q118
To be checked after HBA on ‗1‘-
1. If required wedge in energized position.
2. While working ensure all auxiliaries are working (Frequently).
3. Clear block section only.
4. Not to wedge in trailing loco. (If needed drive from trailing loco after wedging.)
Q52
1. If required wedge in de-energized condition.
2. While taking notches by MP quickly bring to ‖N‖ from + or – or quickly release
BPP/BPR while using EEC.
QTD101(SIV fitted LOCO)
1. If required wedge in energized condition.
2 .Close BLCPA/BLCPD after at least 5 seconds SIV starts ( LSCHBA extinguish.)
QCON (SIV fitted loco)
1. If required wedge in energized condition.
2. Close DJ by manual operation of Q118.
3. Close BLCPA/BLCPD after at least 5 seconds SIV starts
QSVM
1. To be wedged either in energized or de-energized condition if SIV fail to restart
after closing BLVMT .Always close BLVMT before closing DJ
Page 101 of 105
AIR DRYER

TWIN TOWER REGENERATING TYPE DESSICANT AIR DRYERS is used to remove

 OIL DROPLETS FROM AIR


 DIRT PARTICLES FROM AIR
 MOISTURE FROM AIR

It is fitted in between MR-2 and MR-3. It comes into function when compressors are
working. While air dryer is in service, slight exhaust of air takes place continuously from
purge valves alternatively. This should not be considered as leakage.

If only MR is not maintaining due to air leakage from air dryer, air dryer may be isolated
– mention in the log book with date and time.

Visual checking of Humidity indicator :

a) Blue colour: Dryer is performing correctly.


b) Lavender: Dryer is suspected for any malfunctioning.
c) White: Possible damaged dryer.
d) Yellow or Brown colour : Damaged dryer. It indicates that desiccant has
been contaminated with oil. Replacement of
coalesci and desiccant is required.

Note :
Service – Cock ―A‘ & ―B‖ open – ―C‖ close.
Isolate -- Cock ―A‘ & ―B‖ close – ―C‖ open.

Page 102 of 105


WORKING WITH THE LEADING LOCO IN MU/CONSIST WHEN

LEADING LOCO IS DEFECTIVE

SL. Type of defects on Action to be taken by the Loco


Precautions to be observed
No. Leading loco Pilot
1. ICDJ Close BLDJ. Press BLRDJ Ensure ZPT on pos -1 or 2.
Release BLRDJ after 3 to .5 Panto‘s of both locos are raised
sec‘s Resume Traction

2. TLTE – A1 & A2 both Put ZSMS switch on position – Ensure Q49 and Q52 are De-
are ‗0‘. ‗0‘in all locos of MU or consist (If energized. If energized Wedge
A) GR not progressing needed) for EEC and ensure on Q49 and Q52 in De – energized
at all ‗1‘ while Resume Traction with condition on all Locos
MP operating from leading loco.
B) GR is progressing

3. GR Safety Valve Blown Isolate VEPT both cut out cocks Ensure fire, if any is properly
close BLDJ. Press BLRDJ extinguished. Ensure there is
Release BLRDJ after 3 to.5 secs Smoke Emission due to oil
Resume Traction Clear Block spread near GR. Ensure both
Section. Pantos are Lowered on Leading
Loco.

4. If DJ trips through QGR Check for any abnormality near Ensure there is no oil spread
GR If no abnormality is noticed. near GR. Oil Level in the GR oil
Reset the relay target. Close DJ gauge is between + 20 and –20
Resume Traction. degrees.

5. If DJ trips through QGR Isolate VEPT both cut out cocks Ensure both pantos are
again. Close BLDJ. Press BLRDJ Lowered on Leading Loco.
Release BLRDJ after 3 to5
seconds Resume Traction. Clear
Block Section.

6. Smoke Emission From Take safety Measures. Ensure both Pantos are
ARNO Extinguish the Fire. Isolate Lowered on Leading Loco.
VEPT both cut out cocks. Close
BLDJ. Press BLRDJ Release
BLRDJ after 3to.5 secs. Resume
Traction.

7. MR Air Hose Pipe Isolate MR Air Hose Pipe cutout Ensure Pressure is more than
Burst cocks on both locos. Close 8Kg / Cm2. If less, Build up RS
BLDJ press BLRDJ Release pressure individually on both
BLRDJ after LSCHBA goes out. Locos.
Resume Traction.

Page 103 of 105


PARTS OF OHE CANTILEVER

Page 104 of 105


PARTS OF PANTOGRAPH

Page 105 of 105