Verification of Economizer Parameter
Verification of Economizer Parameter
Verification of Economizer Parameter
α P C (T1 – t)
S = • ln
k (1 - r) (T – t1)
where:
S = heating surface
17,716 ft²
α = coefficient, 0.95
P = 467,824 lb/hr
C = 0.3 Btu/lb °F
k = 7 Btu/ft²/h/°F
r = (t – to) / (T1 – T)
where:
t = water temperature @
economizer outlet
t1 = 230°F
T1 = 520°F, T = 320°F
Then, r = 0.575
And substituting for the variables to get t,
(0.94)(0.3)(467,824)
k (1-r) 70