HPCL SOP PH-12

Rev: 1.0

Release Date Prepared by Approved By Rev

March 31 2021 Mr. Vikrant Bingi 1. Mr. Dinabandhu Bhukta 1.0


2. Mr. Bhaskar Udaya

FUELING YOUR BUSINESS FOR SUCCESS


Contents
Chapter1: Image and Siteomat installation & configuration Page

A) Image 2.1.15(2.5GB) Installation…………………………………………………………..…..…4


B) Siteomat Version (7.55.28.1) ……………………………………………………………………...4
B.1) FCC redundant cluster installation…………………………………………………….….4

C)Siteomat BUS config ………………………………………………………………………………………4

D) Siteomat Pump Server……………………………..……………………………………………….…..5


E.1) Additional settings ………………………………………………………….………………5

E) Tank Configuration ………………………………………………………………………….…...….…..6

E.1) TLG ……………………………………………………………………………..…….….………..6

E.2) Probes ……………………………………………………………………………………..……..6


F) TANK Configuration …………………………………………………………………………………..…..7

F.1) Product configuration………………………………………………..…………………….7

F.2) Tank setup…………………………………...….………………………………………………8

G) Siteomat Setup…………………………………………………………………………………………..….9
G.1) Pump specific settings…………………………………………………..…………….….9

H) Setup=>global …………………………………………………………………………..………..……...10

H.1) Setup=>global=>comm ……………………………………………………..……….…10

H.2) Setup=>global=>HOS field……………………………………………….…….………11


H.3) Setup=>global=>Advanced:……………………………………………………………11

I) EDC Configuration………………………………………………………………………………………….12

I.1) EDC1 …………………………………………………………………………………….…………12

I.2) EDC2 ……………………………………………………………………………….………………12

2
Chapter 2: WGT Conversion/Setup/Version Upgrade Page

A) CnWGT Home page and login………………………………………………………………………. 13

A.1) Credentials for new nWGT login………………………………………………………13


A.2) License file upload to convert nWGT into CnWGT…………………………...13
A.3)First Method of WGT version upgrade……………………………………………..15
A.4)Second Method of WGT version upgrade…………………………………………16
B)Setup…………………………………………………………………………………………………………...…17
B.1)Minimal setup……………………………………………………………………………….….17
B.2)General setup ………………………………………………………………………………….18
B.3) CnWGT Config ………………………………………………………………………………..18
B.4) Save and Reset………………………………………………………………………………..19
C)Status…………………………………………………………………………………………………………..…19
D) Administration ……………………………………………………………………………………………..19
D.1) WGT Map……………………..………………………………………………………………..19

3
Chapter 1-Image and Siteomat installation & configuration:
A) Download an image 2.1.15 from below link and install in BAT I-3 board.
https://vontier-
my.sharepoint.com/:f:/g/personal/vikrant_bingi_gilbarco_com/EoqvFnaXFdryel9CbV
EvoI0BlHN-5EUgmJcdGO3Qcndkxg?e=zZS4Yw

B) Download for siteomat version(7.55.28.1) from below link and upgrade


it freshly in both FCC.
https://vontier-
my.sharepoint.com/:u:/g/personal/vikrant_bingi_gilbarco_com/EQAMgwg_4q9JosAf
DzM_G4UBMBsTZGZulj4pKw5bF_qAkA?e=Of40lm

Siteomat default Password: U$4F7dc8 and create new Admin password.

B.1) Install ClusterInstall3.V3.6.B17.tar in one FCC. Refer below manual.


https://vontier-
my.sharepoint.com/:f:/g/personal/vikrant_bingi_gilbarco_com/Em0CnPqul-
9Lvyk0sPzebzEBsMhaoNmqor-rrGyJgqsTOA?e=b1f7QB

C)Siteomat BUS configuration:

4
D)Pump Server:

D.1) Additional settings:

5
E) Tank Configuration:
E.1) TLG:

E.2) Probes:

6
F) TANK Configuration:
F.1) Product configuration:
Important- Product code must be checked/corrected before enabling communication services from
global=>comm setting. Otherwise you will not be allowed to change.

7
F.2) Tank setup:

Important for RSP:


F.1.1) Product Id Mapping to product name :

Product
Name Product ID

MS 1322000

HSD 1683000

TURBOJET 1683100

POWER 1322100

POWER 99 2682000

Very IMP:

All Tank cable shield wire should be common at earthing point in the cabinet and same point
should be connected to ground pin of CnWGT RS485 port.

8
G) Setup:

G.1) Pump specific settings:

9
H)Setup=>Global:

H.1)Comm Settings:

Mode: Central server (CHOS)


HOST/IP: retailhos.hpcl.co.in

Port: 443

10
UserName: Admin

Password: Admin

H.2) Setup=>global=>HOS Field:

H.3) Setup=>global=>Advanced:

11
I) EDC Configuration:
I.1) EDC1:

I.2) EDC2:

12
Chapter 2:WGT Conversion/Setup/Version upgrade:
A) Home page and login page:

Browse WGT page with it’s IP address in google chrome https://192.168.1.170

A.1) Credentials for fresh nWGT login


Username: Admin
Password: Admin
After first login you will be asked to change password use “Orpak1983” for permanent
password for all sites.

A.2) login with below credentials and update license file as below mentioned steps
to convert nWGT to CnWGT.

Username: Admin
Password: Orpak1983
• Once login go to “Software Distribution” select file type “License file” then browse
license file and click on upload

13
• It will take 5-10 seconds to reload page (during time don’t refresh or restart WGT
page).
• Once page refreshed device will show as CnWGT.

14
A.3)First Method of WGT version upgrade:

a. Ensure latest WGT version and bootloader is installed at in WGT if not, follow any one of
below methods.
b. Power ON WGT then conect WGT LAN cable to FCC/Laptop or open WGT web page in
mobile google chrome by connection mobile to same network to fcc over Wi-Fi.
c. Open CnWGT page in Laptop/Mobile(chrome).
d. Download latest Software version(09.05.12) from below link:
https://vontier-
my.sharepoint.com/:u:/g/personal/vikrant_bingi_gilbarco_com/EQQtau_PeapFr4BoIWLHIl8
BLgl5tN12kied1LxHbEgPzQ?e=ccSidi
e. Go to ADMINISTRATION=>Software Distrubution.
f. In the Software Distribute tab, upload software version and select the Update at Admin.
Command radio button under Update Options, and select the Manual radio button on the
right
g. Browse software version file the click on upload.
Wait until all nWGTs at the station receive the new version and the status for each nWGT
changes from In Progress to Pending (this may take a couple of minutes).

h. Wait until all the main nWGT is pending


i. Click Send to send the command to replace the firmware version.
j. Validate version 09.05.12 has been replaced in all nWGT devices.

k. In similar manner need to upgrade WGT firmware version if you updating with Laptop or
Mobile only and if you are updating throgh FCC then follow method 2.

Note: Main WGT firmware version wont be upgrade with FCC.

15
A.4)Second Method of WGT version upgrade:
In order to use/upload 09.55.12 file through FCC using admin port and automatic version
upgrade, follow below procedure.
1. Copy new firmware file to folder into Document then run below command
cp Documents/WGT_firmaware_version /home/fcc/New
pkill FCC

2. Once you get the status in CnWGT as in-progress then follow below
a. Go to /home/orpak/Pending location and remove bin file from it by below
command.
cd /home/orpak/Pending
rm -f WGT_firmaware_version

3. Upload process to CnWGT should be triggered within 15 minutes.


4. Wait for upload process to complete (15 minutes). once file uploading completed, in FCC
WGT status would be as “pending”

5. Wait for process to complete for all slave(nWGT) devices (~15 minutes per PnWGT / slave).
6. All device will show as Pending one by one.
7. Click on Send button to distribute across all the WGT. it will take 10 seconds to refresh the
page

8. Validate main firmware version has been replaced in all nWGT devices.

16
9. Browse to CnWGT via Google Chrome and execute Activation
a. If you did not see “Administrator” tab on left side navigation menu, in setup
configure master exists as “NO” and click SUBMIT available on same page. And also
click on “Submit and reset” on “Save Setup” tab. Device will reset.

B) Setup:
B.1) Minimal setup:

17
B.2) General setup:

• Need to set current data and time in RTC section.

B.3) CnWGT Config:

For DU communication it is must to select protocol as “Pump Server”.

18
B.4) Save and Reset:

C)Status:

D) Administration:
D.1) WGT Map:

19
THANK YOU