16 mm Ø STEEL BAR FOR

COLUMN COLUMN REINFORCEMENT @15CM O.C.B.W. COLUMN


16 mm Ø STEEL BAR FOR
(TRANSVERSE TOP BARS) COLUMN REINFORCEMENT @15CM O.C.B.W.
(TRANSVERSE TOP BARS)

16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR


1500 COLUMN REINFORCEMENT @15CM O.C.B.W. 1500 COLUMN 1500 COLUMN REINFORCEMENT @15CM O.C.B.W.
1500
(TRANSVERSE TOP BARS) (TRANSVERSE TOP BARS) COLUMN
300 300 228 300
300 300

16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR
COLUMN REINFORCEMENT COLUMN REINFORCEMENT 300 COLUMN REINFORCEMENT COLUMN REINFORCEMENT
@15CM O.C.B.W. @15CM O.C.B.W. @15CM O.C.B.W. @15CM O.C.B.W.
(LONGITUDINAL TOP BARS) (LONGITUDINAL TOP BARS) (LONGITUDINAL TOP BARS) (LONGITUDINAL TOP BARS)
1500 16 mm Ø STEEL BAR FOR
1500 16 mm Ø STEEL BAR FOR
1500 1500
16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR
COLUMN REINFORCEMENT COLUMN REINFORCEMENT 300 COLUMN REINFORCEMENT COLUMN REINFORCEMENT
@15CM O.C.B.W. @15CM O.C.B.W.
300
@15CM O.C.B.W. @15CM O.C.B.W.
(TRANSVERSE BOT. BARS) (TRANSVERSE BOT. BARS) (TRANSVERSE BOT. BARS) (TRANSVERSE BOT. BARS)

16 mm Ø STEEL BAR FOR


16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR
COLUMN REINFORCEMENT
COLUMN REINFORCEMENT COLUMN REINFORCEMENT 1300 COLUMN REINFORCEMENT
@15CM O.C.B.W.
@15CM O.C.B.W. @15CM O.C.B.W. @15CM O.C.B.W.
(LONGITUDINAL BOT. BARS)
(LONGITUDINAL BOT. BARS) (LONGITUDINAL BOT. BARS) (LONGITUDINAL BOT. BARS)

1A F1C1 PLAN 1C F1C2 PLAN 1E F2C4 PLAN 1G F1C3 PLAN


S 04 SCALE 1:50 MTS S 04 SCALE 1:50 MTS S 04 SCALE 1:50 MTS S 04 SCALE 1:50 MTS

COLUMN COLUMN

COLUMN COLUMN

FOOTING TIE BEAM FOOTING TIE BEAM FOOTING TIE BEAM


FOOTING TIE BEAM
(WHERE OCCURS) (WHERE OCCURS) (WHERE OCCURS)
(WHERE OCCURS)

1.500 16 mm Ø STEEL BAR FOR 1.500 16 mm Ø STEEL BAR FOR 1.500 16 mm Ø STEEL BAR FOR 1.500 16 mm Ø STEEL BAR FOR
COLUMN REINFORCEMENT COLUMN REINFORCEMENT COLUMN REINFORCEMENT COLUMN REINFORCEMENT
@15CM O.C.B.W. @15CM O.C.B.W. @15CM O.C.B.W. 1000 @15CM O.C.B.W.
1000 1000 1000
0.20 (LONGITUDINAL TOP BARS) 0.20 (LONGITUDINAL TOP BARS) 0.20 (LONGITUDINAL TOP BARS) 0.20 (LONGITUDINAL TOP BARS)

16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR 16 mm Ø STEEL BAR FOR
COLUMN REINFORCEMENT COLUMN REINFORCEMENT COLUMN REINFORCEMENT COLUMN REINFORCEMENT
200MM THK. @15CM O.C.B.W. 200MM THK. @15CM O.C.B.W. 200MM THK. @15CM O.C.B.W. 200MM THK. @15CM O.C.B.W.
COMPACTED (TRANSVERSE BOT. BARS) COMPACTED (TRANSVERSE BOT. BARS) COMPACTED (TRANSVERSE BOT. BARS) COMPACTED (TRANSVERSE BOT. BARS)
BASECOURSE BASECOURSE BASECOURSE BASECOURSE
1.500 1.500 1.300 1.500
ENGINEERED FIIL ENGINEERED FIIL ENGINEERED FIIL ENGINEERED FIIL

1B F1C1 SECTION 1D F1C2 SECTION 1F F2C4 SECTION 1H F1C3 SECTION


S 04 SCALE 1:50 MTS S 04 SCALE 1:50 MTS S 04 SCALE 1:50 MTS S 04 SCALE 1:50 MTS

1 COLUMN FOOTING AND COLUM DETAILS


S 04 SCALE 1:50 MTS

ARCHITECTURE ACT OF 2004 (P.D 9266) DESIGNED BY


CIVIL ENGINEER PRC REG NO: ALLIED PROFESSIONAL PROJECT TITLE OWNER'S NAME SHEET CONTENTS SHEET NO.
J.A. MENDOZA
Section 33 (Article 4) Ownership of Plans, Specifications
and other Contract Documents - COLUMN FOOTING & COLUMN
2-STOREY RESIDENTIAL CHALMARIJOY MAKINANO PIE & CADD BY
Drawings and specifications duly signed, stamped or sealed DETAILS

S 04
PLACE: as instruments of services are the property and documents HOUSE PLAN CATHERINE RUIZ PIE J.A. MENDOZA
of the Architect, whether the objects for which they are
made is executed or not. It shall be unlawful for any person CHECKED BY
without the written consent of the Architect or Author of the
PROJECT LOCATION OWNER'S ADDRESS
said documents to duplicate or to make copies of the said
VALID UNTIL:
documents for use in repetition of and for projects or TRACED BY
buildings whether partly or in whole without the consent of Purok 7, Brgy. 18, Obrero, Butuan City
the Architect or author of said documents.

You might also like