Lab Assignment-4

1) Aim: To design an active butterworth band pass filter.


Apparatus: Resistors of values 1.4k, 2.73k, 100 and 5 ohms, two
capacitors of 47nf, opamp etc.
Experiment: Design an active band pass filter as follows.

𝑅1 = 𝑅2 = 1400 𝛺, 𝐶1 = 𝐶2 = 47𝑛F, 𝑅𝑓 = 1.95𝑅1 = 2.73𝑘.


Measure Vout and Vin in oscilloscope
Observation: Simulation of circuit in LT spice

Conclusion: An active butterworth band pass filter is constructed.