 TECHNICAL TRAINING MANUAL 
 M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3) 
 WATER & WASTE 
This document must be used for training purposes only

Under no circumstances should this document be used as a reference

It will not be updated.

All rights reserved


No part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,
without the prior written permission of AIRBUS S.A.S.
Single Aisle TECHNICAL TRAINING MANUAL

WATER & WASTE


GENERAL
Water/Waste Level 2 (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
POTABLE WATER (A320)
Potable Water System D/O (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
POTABLE WATER (A318/A319/A321)
Potable Water System D/O (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
WASTE WATER
Waster Water System D/O (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
TOILET
Toilet System Principle (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Toilet System Description (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
MAINTENANCE PRACTICE
Potable Water SYS Servicing (A320) (2) . . . . . . . . . . . . . . . . . . . . . . 36
Potable Water SYS Servicing (A318/319/321) (2) . . . . . . . . . . . . . . . 42
Toilet System Servicing (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
U5F07351 - U1135T0

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  TABLE OF CONTENTS Sep 12, 2007
38 - WATER & WASTE Page 1
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


SYSTEM OVERVIEW
The water and waste system consist of three subsystems:
- Potable water system
- Waste water system
- Toilet system
WATER AND WASTE FLUID STORAGE (A318 / A319 /
A321)
The potable water tank and the waste holding tank are installed in the
pressurized underfloor area LH rear the aft cargo compartment. An
indication system monitors the water and waste tank quantities.
POTABLE WATER SYSTEM
The potable water system supplies water from the water tank through
a distribution system to the user. The water is supplied to water faucets
in the galleys and lavatories. The system also supplies water to the
water heaters and vacuum toilet units. Mechanically or electrically
operated valves control the supply of the potable water system.
Compressed air is used to pressurize the system to supply water from
the tank to the necessary service locations. The air pressure is supplied
from the bleed air system in normal configuration or a ground pressure
connection for maintenance. An air compressor can be installed as an
U5F07351 - U1135T0 - UM38BA000000002

option. Each lavatory can be isolated from the potable water


distribution system through a manual shut-off valve.

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 2
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

SYSTEM OVERVIEW - WATER AND WASTE FLUID STORAGE (A318 / A319 / A321) & POTABLE WATER SYSTEM

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 3
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


SYSTEM OVERVIEW (continued)
WATER AND WASTE FLUID STORAGE (A320)
For the A320 only, the location of the potable water tank is aft of the
forward cargo compartment.
U5F07351 - U1135T0 - UM38BA000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 4
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

SYSTEM OVERVIEW - WATER AND WASTE FLUID STORAGE (A320)

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 5
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


SYSTEM OVERVIEW (continued)
POTABLE WATER HEATING, ICE PROTECTION AND
WINTERIZATION PROTECTION
One water heater is installed in each lavatory and in each galley. Water
pipes, where icing conditions can occur are insulated and heated by
tape electrical heaters. The potable water service panel is heated to
prevent ice formation. Optionally, the fill/drain nipple and overflow
nipple are also electrically heated. These heating elements are
controlled automatically by two anti-ice control units installed in the
cargo compartments. In winter conditions, the potable water system
must be drained during night stops.
U5F07351 - U1135T0 - UM38BA000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 6
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

SYSTEM OVERVIEW - POTABLE WATER HEATING, ICE PROTECTION AND WINTERIZATION PROTECTION

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 7
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


SYSTEM OVERVIEW (continued)
POTABLE WATER CONTROL AND INDICATING (FAP)
The water and waste indications are displayed on the Flight Attendant
Panel (FAP) for aircraft fitted with cabin systems. ON FAP, the
quantity indication is displayed automatically as soon as the service
panel is open, or when the Water/Waste key on the FAP is selected.
As an option, the filling quantity can be selected (25%, 50%, 75%
and 100%).
U5F07351 - U1135T0 - UM38BA000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 8
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

SYSTEM OVERVIEW - POTABLE WATER CONTROL AND INDICATING (FAP)

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 9
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


SYSTEM OVERVIEW (continued)
POTABLE WATER CONTROL AND INDICATING
(SERVICE PANEL)
There is only one control handle to fill or drain the water tank. It is
located on the water service panel. One drain valve is electrically
controlled when the fill/drain control handle is set to the drain position.
The overflow valve opens electrically when the fill/drain valve handle
is set to the drain or fill position. On the servicing panel, the indicator
gives the water quantity. One green light indicates that the forward
drain valve is open and one green light indicates that the tank is full.
U5F07351 - U1135T0 - UM38BA000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 10
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

SYSTEM OVERVIEW - POTABLE WATER CONTROL AND INDICATING (SERVICE PANEL)

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 11
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


SYSTEM OVERVIEW (continued)
WASTE WATER SYSTEM
The waste water system drains the used water from the lavatory
washbasins and the galley sinks. The waste water is discarded
overboard outside through the drain valve and the drain mast. The
two drain masts and drain lines have integrated electrical heating
elements to prevent ice formation at high altitude or during cold
weather.
U5F07351 - U1135T0 - UM38BA000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 12
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

SYSTEM OVERVIEW - WASTE WATER SYSTEM

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 13
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


SYSTEM OVERVIEW (continued) TOILET SYSTEM CONTROL AND INDICATING
The vacuum toilet system is connected to the CIDS. The CIDS controls
TOILET SYSTEM and monitors the system functions and the related electric components.
The toilet system gives sanitary facilities for the passengers and crews. A Flush Control Unit (FCU) per toilet controls the rinse and flush
The system is a vacuum type toilet system and uses potable water for cycle as soon as the flush SW is pressed. The system uses potable
flushing. water from the potable water system to rinse the toilet bowl. When
the waste holding tank is full, a signal is sent to the CIDS, which shuts
TOILET SYSTEM FLUSHING OPERATION
down the toilet systems. The FAP displays the waste tank quantity
The system uses potable water from the aircraft pressurized water stored in the waste holding tank when the Water/Waste key on the
system to flush the toilet. A vacuum drain valve removes waste from FAP is selected.
the toilet bowl to an under floor waste holding tank. At high altitude,
the differential pressure between the cabin and the atmospheres is
sufficient to move the waste from the toilet bowl into the waste holding
tank. At low altitude or on ground, a vacuum generator starts to give
the necessary differential pressure in the waste system to move the
waste from the bowl to the tank. The Vacuum System Controller
Function (VSCF), integrated in the Cabin Intercommunication Data
System (CIDS), controls the flushing system operation and stops the
operation when the waste servicing panel is open. When the tank is
full, the liquid level transmitter stops the system operation.
TOILET SYSTEM WASTE DISPOSAL
The waste holding tank is installed on the right of the aircraft under
U5F07351 - U1135T0 - UM38BA000000002

the floor behind the bulk cargo compartment. The tank includes a
water separator, a liquid level transmitter, a liquid level sensor, a waste
drain valve and two rinse line connections.
TOILET SYSTEM WASTE TANK HEATING
(OPTIONAL)
The waste holding tank can be insulated. The lines between the tank
and the service panel with the waste drain valve can be insulated and
heated.

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 14
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

SYSTEM OVERVIEW - TOILET SYSTEM ... TOILET SYSTEM CONTROL AND INDICATING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 15
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


SERVICING
POTABLE WATER SERVICING
The potable water system supplies the galleys and toilets with water
from the tank via a distribution system. The tank is pressurized by air
either:
- From the pneumatic system,
- Or from a ground cart connected to the ground connector,
- Or optionally from a compressor.
On the A320 only, two valves are used for filling:
- The fill/drain valve, this is opened manually and closed electrically,
- The overflow valve, this is opened and closed electrically,
Four valves are used for draining:
- The fill/drain valve, this is opened and closed manually,
- The FWD drain valve, tank drain valve and overflow valve, these
are opened and closed electrically.

NOTE: On A320, if there is no electrical power all four valves can


be manually operated.
On A318, A319 and A321, one valve is used for filling:
- The overflow/fill/drain valve, this is opened manually and closed
electrically,
U5F07351 - U1135T0 - UM38BA000000002

Two valves are used for draining:


- The overflow/fill/drain valve, this is manually operated,
- The FWD drain valve, this is electrically operated.

NOTE: On A318, A319 and A321, if there is no electrical power


both valves must be manually operated.

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 16
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

SERVICING - POTABLE WATER SERVICING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 17
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


SERVICING (continued)
TOILET SYSTEM SERVICING
Connect the toilet service vehicle to the toilet service panel.
Move the drain valve control-handle from the close to the open
position.
Drain the waste from the toilet tank.
Flush the toilet system.
Fill the toilet tank with 10 l of disinfectant solution.
Do not discharge products such as oil, fuel, solvent, lubricant either
in trash bins, soil or into the water network (drains, gutters, rain water,
waste water, etc...)
Sort waste fluids and use specific waste disposal containers.
U5F07351 - U1135T0 - UM38BA000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 18
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

SERVICING - TOILET SYSTEM SERVICING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 19
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


MEL/DEACTIVATION
If the drain mast is not heated, the aircraft can be dispatched provided
that the associated galleys or toilets are not used (toilet door locked and
placarded "Inoperative'') and their water shut off valves are closed.
U5F07351 - U1135T0 - UM38BA000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 20
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

MEL/DEACTIVATION

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 21
Single Aisle TECHNICAL TRAINING MANUAL

WATER/WASTE LEVEL 2 (2)


MAINTENANCE TIPS
POTABLE WATER SYSTEM DRAINING IN COLD
WEATHER CONDITIONS
In cold weather conditions the potable water system must be drained
to prevent damage to the system by ice. To decide if the potable water
system needs be drained, we must refer to the water system drain
configuration table in the AMM 12-24-38. If the bleed air system is
off and the outside air temperature is below 0 °C (32 °F), the drain
valves must remain open after the potable water system is drained to
prevent damage to the potable water system. The cold weather
maintenance practices for the potable water system are given in the
AMM 12-31-38.
U5F07351 - U1135T0 - UM38BA000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 22
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38BA000000002

MAINTENANCE TIPS - POTABLE WATER SYSTEM DRAINING IN COLD WEATHER CONDITIONS

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WATER/WASTE LEVEL 2 (2) Sep 17, 2007
38 - WATER & WASTE Page 23
Single Aisle TECHNICAL TRAINING MANUAL

POTABLE WATER SYSTEM D/O (2)


(118,4 °F). An over temperature safety device protects the heating
STORAGE element.
The potable water is stored in one tank installed in the pressurized INDICATING
underfloor area of the right hand fuselage, aft of the forward cargo
compartment. The potable water tank has a capacity of 200 l (53 US gal). The quantity indication system indicates how much water is available in
the potable water tank. The quantity transmitter transmits the signal to
PRESSURIZATION the indicator on the water service panel and to the Forward Attendant
Panel (FAP). The TANK FULL light on the service panel comes on when
Pressurization of the system enables water supply from the tank to the
the tank is full.
necessary service location. Compressed air is tapped from the cross feed
line of the engine or APU bleed air. On ground, when the bleed air system FILLING
is not available, the ground air pressure supply system is used. If installed,
an optional compressor is used for the pressurization in case of bleed air The Filling is achieved through a fill/drain valve operated by the fill/drain
decrease. During servicing, the overflow valve lets the potable water tank control handle on the potable water service panel. The fill/drain control
depressurized. handle simultaneously opens the electrically motorized overflow valve
for venting. The quantity transmitter sends a tank-full signal to close the
DISTRIBUTION fill/drain valve automatically. Manual operation is possible via control
handles dedicated to each valve. Maximum permissible pressure to fill
Potable water from the water tank is supplied through a system of
the potable water tank is 50 psi (3.4 bars).
distribution lines. The lavatory and galley distribution lines run below
the passenger compartment floor. They are shrouded and insulated, and
CAUTION: WITHOUT ELECTRICAL POWER YOU MUST OPEN
some of them are electrically heated to prevent ice formation. Each
THE OVERFLOW VALVE MANUALLY PRIOR TO THE
lavatory and each galley have an individual and manual shutoff valve.
FILLING TO PREVENT WATER SPILLAGE IN THE
U5F07351 - U1135T0 - UM38D1000000002

USER SUPPLY CABIN.

Each lavatory can be isolated from the potable water distribution system DRAINING
through a manual Shut-Off Valve (SOV).
The draining operation is achieved through the fill/drain valve and two
HEATING motorized drain valves using the same control handle as the filling
operation. In this case, the overflow valve is also controlled to open.
A water heater is installed under the wash basin inside the sanitary unit Manual operation is possible via control handles dedicated to each valve.
cabinet. If the quantity transmitter detects a low level into the water tank,
it cuts the electrical supply of the water heater. A thermostat allows the
water temperature to be maintained between 45 °C (113 °F) and 48 °C

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYSTEM D/O (2) Sep 17, 2007
38 - WATER & WASTE Page 24
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38D1000000002

STORAGE ... DRAINING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYSTEM D/O (2) Sep 17, 2007
38 - WATER & WASTE Page 25
Single Aisle TECHNICAL TRAINING MANUAL

POTABLE WATER SYSTEM D/O (2)


STORAGE INDICATING
The potable water tank with a capacity of 200 l (53 US gal) is installed The quantity indication system indicates how much water is available in
in the pressurized LH under floor area behind the rear cargo compartment. the potable water tank. The quantity transmitter transmits the signal to
the indicator on the water service panel. It also sends the information to
PRESSURIZATION a Decoder/Encoder Unit (DEU) B, which in turn interfaces with the active
Cabin Intercommunication Data System (CIDS) director to display on
Compressed air is used to pressurize the system in order to supply water
the Flight Attendant Panel (FAP) the water tank contents in percentage
from the tank to the necessary service locations. The compressed air is
of volume. The TANK FULL light on the service panel comes on when
tapped from the cross feed-line of the engine or APU bleed air and is
the tank is full.
connected to the water tank air inlet. On ground, when the bleed air system
is not available, the ground air pressure supply system is used. If installed, SERVICING
an optional compressor is used for the pressurization in case of bleed air
decrease. The Servicing of the potable water system can be done with or without
electrical power. With electrical power, the single fill/drain control handle
DISTRIBUTION mechanically operates the fill/overflow drain valve and electrically
controls the forward drain valve. Without electrical power, the valves
Potable water from the water tank is supplied through a system of
are individually operated by cables. The draining operation is
distribution lines, which are routed below the passenger compartment
accomplished by opening the fill/overflow drain valve and the forward
floor. A part of the forward distribution line goes through a hose for added
drain valve. The filling operation is accomplished by opening the
protection. The potable water distribution lines are insulated and
fill/overflow drain valve and closing the forward drain valve. When the
electrically heated to prevent ice formation in and around the lines. Each
tank is full, the quantity transmitter sends a signal to close the fill/overflow
lavatory and each galley have an individual and manual shutoff valve.
drain valve automatically.
U5F07351 - U1135T0 - UM38D1000000001

HEATING
In each lavatory, a water heater is installed under the wash basin. If the
quantity transmitter detects a low level into the water tank, it cuts the
electrical supply of the water heater. A thermostat maintains the water
temperature between 45°C (113°F) and 51.7°C (125°F). An over
temperature safety device protects the heating element.

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYSTEM D/O (2) Sep 17, 2007
38 - WATER & WASTE Page 26
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38D1000000001

STORAGE ... SERVICING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYSTEM D/O (2) Sep 17, 2007
38 - WATER & WASTE Page 27
Single Aisle TECHNICAL TRAINING MANUAL

WASTER WATER SYSTEM D/O (3)


GENERAL
The waste water drain system discards the waste water from the lavatory
wash basins and from the galley sinks.

DRAIN ASSEMBLY
Each lavatory wash basin has a drain assembly with a valve actuated by
a control knob and a cable.

NOTE: The control knob is operated by the lavatory user.

DRAIN VALVE
Each drain valve opens only when a certain amount of water is collected.
This prevents a permanent loss of cabin air pressurization through the
drain lines.

DRAIN MAST
In flight, differential pressure between the cabin and the drain mast outlet
discards the waste water. On ground, gravity discards the waste water.
The drain masts are electrically heated to prevent ice formation.
U5F07351 - U1135T0 - UM38D2000000001

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WASTER WATER SYSTEM D/O (3) Sep 17, 2007
38 - WATER & WASTE Page 28
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38D2000000001

GENERAL ... DRAIN MAST

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  WASTER WATER SYSTEM D/O (3) Sep 17, 2007
38 - WATER & WASTE Page 29
Single Aisle TECHNICAL TRAINING MANUAL

TOILET SYSTEM PRINCIPLE (2)


GENERAL
Potable water from the aircraft pressurized potable water system is used
to flush the toilet bowl. Differential pressure between the cabin and the
atmosphere moves the waste from the toilet bowl to the waste holding
tank. This difference of pressure can be caused by the vacuum generator
or by aircraft pressurization.

RINSE/FLUSH CONTROL
A flush control unit per toilet controls the time and sequence of the toilet
operation during the flushing cycle.

VACUUM CONTROL
A vacuum generator is connected to the aircraft power circuit through
the motor starting relay. As soon as a FLUSH switch is pressed, the flush
control unit sends an electrical signal, through the connected
Decoder/Encoder Unit (DEU) B to the Cabin Intercommunication Data
System (CIDS) directors, which activates the motor starting relay
according to the altitude. The Cabin Pressure Controller (CPC) supplies
altitude data to CIDS via the System Data Acquisition Concentrator
(SDAC). At high altitude, the CPC stops the electrical supply of the
vacuum generator, the differential pressure between the cabin and the
U5F07351 - U1135T0 - UM38P1000000002

atmosphere being sufficient to move the waste from the toilet bowl to
the waste holding tank. At low altitude or on ground, the vacuum
generator generates the necessary differential pressure.

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  TOILET SYSTEM PRINCIPLE (2) Sep 17, 2007
38 - WATER & WASTE Page 30
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38P1000000002

GENERAL ... VACUUM CONTROL

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  TOILET SYSTEM PRINCIPLE (2) Sep 17, 2007
38 - WATER & WASTE Page 31
Single Aisle TECHNICAL TRAINING MANUAL

TOILET SYSTEM DESCRIPTION (2)


GENERAL STORAGE
The toilet system removes waste from the toilet bowl through a vacuum The waste holding tank is installed on the right hand side of the aircraft
drain to an underfloor waste holding tank. The vacuum toilet system is under the floor between FRame 65 and FR 68. The tank has a capacity
connected to the Cabin Intercommunication Data System (CIDS), which of 170 l (44.9 US gal). The tank has:
controls and monitors the system function and the related electric - a water separator,
components. The system uses potable water from the potable water system - a liquid level transmitter (hydrostatic pressure),
to flush the toilet. - a liquid level sensor (ultrasonic type),
- waste inlets,
FLUSHING - a waste outlet,
- two flush inlet nozzles.
When the FLUSH switch is pressed, the flush control unit initiates the
flush sequence. The vacuum generator starts to operate and after 1.6 CONTROL/MONITORING
seconds the water valve opens for 1.7 seconds. Then, the flush valve,
controlled by the flush control unit, opens for 4 seconds to evacuate the The waste system data is received by DEUs B and sent to the CIDS
waste material through differential pressure. directors (DIRs). This system is controlled and monitored by the Vacuum
System Controller (VSC) function, which is integrated inside the CIDS
VACUUM DIRs. It also reports the vacuum toilet system failures to the Centralized
Fault Display System (CFDS) and to the RS 232-C interface for shop
As soon as the FLUSH switch is pressed, the flush control unit sends an
maintenance.
electrical signal to the CIDS (via the connected Decoder/Encoder Unit
(DEU) B), which operates the vacuum generator for approximately 15 INDICATING
seconds. The vacuum generator creates the necessary differential pressure
between the cabin and the waste holding tank to move the waste from The waste holding tank is equipped with a liquid level transmitter and a
U5F07351 - U1135T0 - UM38D3000000002

the toilet bowl. The vacuum generator is activated: liquid level sensor. When the tank is full, a signal is sent to the CIDS
- on ground, DIRs through the DEU B, which shuts down the toilet systems. The signal
- during climb when the differential pressure is less than 246 mbar, is also sent to the Flight Attendant Panel (FAP) through the DIRs and a
- during descent when the differential pressure is less than 203 mbar. "WASTE TANK NOT EMPTY-CHECK LEVEL GROUND SERVICE
The different pressure information is supplied by the Cabin Pressure REQUIRED" message is displayed.
Controller (CPC) via the System Data Acquisition Concentrator (SDAC).
SERVICING
NOTE: The landing gear signal is used as a back up in case of CPC or
The waste holding tank is serviced from a service panel, which is located
SDACs failure.
on the right of the lower fuselage between FR 65 and FR 66. It has:
- a drain connection,
M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  TOILET SYSTEM DESCRIPTION (2) Sep 17, 2007
38 - WATER & WASTE Page 32
Single Aisle TECHNICAL TRAINING MANUAL
- a rinse/flush connection,
- an optional waste quantity indicator,
- a waste drain valve control handle,
- a limit switch.
During servicing, the flush control units are automatically de-activated.
Thus, toilet use is inhibited during servicing. The waste drain control
handle mechanically operates the drain valve.
U5F07351 - U1135T0 - UM38D3000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  TOILET SYSTEM DESCRIPTION (2) Sep 17, 2007
38 - WATER & WASTE Page 33
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38D3000000002

GENERAL ... SERVICING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  TOILET SYSTEM DESCRIPTION (2) Sep 17, 2007
38 - WATER & WASTE Page 34
Single Aisle TECHNICAL TRAINING MANUAL

This Page Intentionally Left Blank


U5F07351 - U1135T0 - UM38D3000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  TOILET SYSTEM DESCRIPTION (2) Sep 17, 2007
38 - WATER & WASTE Page 35
Single Aisle TECHNICAL TRAINING MANUAL

POTABLE WATER SYS SERVICING (A320) (2)


FILLING
The water service panel is located on the left side of the aft fuselage.
Electricity must be supplied to the panel. Use ground power and turns
on the MAINTenance BUS switch. When the panel door is open, the
light on the fill gauge indicates that the panel has power. As a back-up
check for electricity, press any one of the four indicator lights, they should
light up. Also on panel are the fill and drain port and the control handle.
To fill the water system, open the service door. Connect the fill hose to
the port. Turn the control handle counter clockwise to the FILL position
and pull out on the handle. Make sure the overflow valve opens: the
indicator light should light up. Turn on the water pump at the truck. The
quantity gauge will show when the system is taking on water. When the
tank is full the FULL light should come on. Turn off the pump of the
truck.
Push the control handle in and turn it back to the NORMAL position. On
some A320, the control handle is automatically pulled in and returns to
the NORMAL position by itself. Disconnect the hose and cap the port.
Before closing the door, clean and dry the service panel and check for
leaks, then close the access door.

NOTE: Filling of the potable water system is also available without


electrical power( AMM Reference Task 12-15-38-613-002).
U5F07351 - U1135T0 - UM38Y1000000001

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A320) (2) Sep 17, 2007
38 - WATER & WASTE Page 36
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38Y1000000001

FILLING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A320) (2) Sep 17, 2007
38 - WATER & WASTE Page 37
Single Aisle TECHNICAL TRAINING MANUAL

POTABLE WATER SYS SERVICING (A320) (2)


DRAINING
Three drain ports controlled by the service panel are used to empty the
water system. The main drain port is located on the underside of the
aircraft directly below the water tank and next to the overflow port. A
few feet ahead of the main drain is another drain port for the forward lav
and galley lines. The port on the water service panel is used to drain the
lines for the rear lavs and galley. To drain the water system, move a
container under the main port.
At the control panel, uncap the port. Turn the control handle clockwise
to the DRAIN position and pull the handle out. Three indicator lights
should come on. They are: the OVERFLOW VALVE OPEN light, the
TANK DRAIN VALVE OPEN light and the FORWARD DRAIN
VALVE OPEN light. Most of the water will come out of the main drain,
only a small amount will come out of the forward and aft drains. When
the system is drained, push the control handle in. Make sure that it returns
to the NORMAL position. All the indicator lights should go off. Replace
the drain cap.
Make sure the service panel is clean and dry. Then close the panel door.
U5F07351 - U1135T0 - UM38Y1000000001

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A320) (2) Sep 17, 2007
38 - WATER & WASTE Page 38
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38Y1000000001

DRAINING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A320) (2) Sep 17, 2007
38 - WATER & WASTE Page 39
Single Aisle TECHNICAL TRAINING MANUAL

POTABLE WATER SYS SERVICING (A320) (2)


MISCELLANEOUS
Without electricity, you will have to use the following manual overrides:
- for filling, open the overflow valve,
- for draining, open both valves of the main drain and the one of the
forward drain.
Maintenance will eventually replaced the X screw holding in this panel
shut with a P/B latch. Information on cold weather water servicing will
be provided by your instructor.
U5F07351 - U1135T0 - UM38Y1000000001

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A320) (2) Sep 17, 2007
38 - WATER & WASTE Page 40
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38Y1000000001

MISCELLANEOUS

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A320) (2) Sep 17, 2007
38 - WATER & WASTE Page 41
Single Aisle TECHNICAL TRAINING MANUAL

POTABLE WATER SYS SERVICING (A318/319/321) (2)


NORMAL FILLING
The water service panel is located on the left side of the aft fuselage.
Electricity must be supplied to the panel. Use ground power and turns
on the maintenance bus (MAINT BUS ON switch). When the service
panel is opened, the light on the fill gauge indicates that the panel has
power. Also on the panel are the fill and drain port and the control handle.
To fill the water system, connect the fill hose to the port. Turn the control
handle couterclockwise to the FILL position and pull out on the handle.
Turn on the water pump on the truck. The quantity gauge will show when
the system is taking on water. When the tank is full, the FULL light comes
on. The control handle returns to the NORMAL position by itself. Turn
off the pump on the truck. Disconnect the hose. Before closing the door,
clean and dry the service panel and check for leaks. Then, close the access
door.
U5F07351 - U1135T0 - UM38Y1000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A318/319/321) (2) Sep 17, 2007
38 - WATER & WASTE Page 42
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38Y1000000002

NORMAL FILLING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A318/319/321) (2) Sep 17, 2007
38 - WATER & WASTE Page 43
Single Aisle TECHNICAL TRAINING MANUAL

POTABLE WATER SYS SERVICING (A318/319/321) (2)


MANUAL FILLING
If electrical power is not available, the manual filling procedure must be
used. To fill the water system, open the servicing panel. Connect the fill
hose to the port. Turn the control handle counterclockwise to the FILL
position and pull out on the handle. Turn on the water pump on the truck.
When the tank is full, the water comes out by the overflow port. Manually
push the control handle back in its NORMAL position. Turn off the pump
on the truck. Disconnect the hose. Before closing the door, clean and dry
the service panel and check for leaks. Then, close the access door.
U5F07351 - U1135T0 - UM38Y1000000002

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A318/319/321) (2) Sep 17, 2007
38 - WATER & WASTE Page 44
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38Y1000000002

MANUAL FILLING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  POTABLE WATER SYS SERVICING (A318/319/321) (2) Sep 17, 2007
38 - WATER & WASTE Page 45
Single Aisle TECHNICAL TRAINING MANUAL

TOILET SYSTEM SERVICING (2)


DRAINING
The lavatory service panel is located on the right side of the aft fuselage.
Open the service door. The controls consist of a drain port, two valve
levers, a drain control handle and a filling port. To empty the waste
system, open the cap assembly and connect the drain hose and next to it
the fill hose. Next to the drain connection is a small lever marked OPEN.
Push this lever in the direction of the arrow; the lever marked CLOSED
should rotate by spring action indicating that the valve has opened. Pull
the drain control handle outward to the extended position. This allows
waste materials to flow from the drain port. When the system is drained
return the control handle to the normal position. To flush the tank, use 5
gallons (19 l) of disinfectant commonly called "Blue Juice". Now drain
the system by extending the control handle. Once drained, return the
handle to the normal position. Replenish with 2 gallons (7,5 l) of blue
juice. You are now ready to disconnect hoses and replace the connection
caps on the drain and rinse ports. By closing the drain cap the drain valve
automatically closes. Clean and dry the panel with a clean cloth and do
not forget to close the service door. On the Forward Attendant Panel:
- if the LAV indicator light is on, reservice the system,
- if the light remains on, contact maintenance or maintenance control.
U5F07351 - U1135T0 - UM38Y2000000001

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  TOILET SYSTEM SERVICING (2) Sep 17, 2007
38 - WATER & WASTE Page 46
Single Aisle TECHNICAL TRAINING MANUAL
U5F07351 - U1135T0 - UM38Y2000000001

DRAINING

M35 LINE MECHANICS (IAE V2500/US) (Lvl 2&3)  TOILET SYSTEM SERVICING (2) Sep 17, 2007
38 - WATER & WASTE Page 47
AIRBUS S.A.S.
31707 BLAGNAC cedex, FRANCE
STM
REFERENCE U5F07351
SEPTEMBER 2007
PRINTED IN FRANCE
AIRBUS S.A.S. 2007
ALL RIGHTS RESERVED

AN EADS JOINT COMPANY


WITH BAE SYSTEMS