SUBMITTAL AM036NN4DCH/AA
Samsung DVM S Series, Wind-Free™ 4-Way Cassette

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #

Specifications
Cooling (Btu/h) 36,000
Performance1 Nominal Capacity
Heating (Btu/h) 40,000

Voltage (ø/V/Hz) 1 / 208-230 / 60


Nominal Running Current (A) 0.56
Power
MCA 0.49
MOP 15 • Compatible with Samsung DVM S, DVM S Water, and DVM S Eco
systems (AM**********AA).
Type Turbo (1)
• Electro-static, washable, pleated filters as standard (included with
Fan Type BLDC fascia panel)
Motor
Output (W) 97 • Built in condensate pump with maximum 29" lift from the bottom
of the unit, check valve, and float switch that disables indoor unit
Airflow CFM (UL) H/M/L 845 / 777 / 706 during overflow detection

Type R410A • Knock-out for outside air capability


Refrigerant
Control Method Electronic Expansion Valve
• Fascia panel shall have LED indicator lights and 4 motorized
louvers with independent control (32° - 65° louver control range)
Liquid (flare) Inches 3/8
Piping • High-voltage terminal block temperature sensor to disable unit in
Suction (flare) Inches 5/8
Connections the event overheating of power connection.
Drain Inches VP25 (OD 1 1/4, ID 1)
• Wind-Free™ function will close the supply air outlet louver while in
Unit WXHXD Inches 33 1/16 X 11 3/8 X 33 1/16 cooling mode to gently disperse cool air into the space without
blowing directly onto occupants. The Wind-Free™ feature is
Dimensions Weight lbs. 40.79 optional and can be enabled using central or local control options
(MWR-SH11UN, MWR-WE13N, MWR-WE13UN, MWR-WG00*N,
Model Number (Wind-Free™) PC4NUFMUN and AR-EH03U only).
LXWXH Inches 37 3/8 X 37 3/8 X 2 1/2
• The Wind-Free™ 4-way cassette can be configured for 2-stage
Weight lbs. 13.89 operation, cooling the space with the louver open (fixed or swing)
Fascia Panel
until the room temperature nears set temperature. Once room
(required)2 Model Number (Standard) PC4NUSKUN temperature is near set temperature, Wind-Free™ operation will
start automatically, closing the louver and using the face of the
LXWXH Inches 37 3/8 X 37 3/8 X 1 13/4 fascia panel to gently cool the space with still air*.
Weight lbs. 12.79
• The Wind-Free™ panel (PC4NUFMUN) has an integral humidity
sensor that will open the louvers for standard cool mode when
Sound Level H/M/L dB(A) 42 / 39 / 36
space conditions could potentially cause condensation formation
on the panel surface.
Fascia Panel (Wind-Free™) PC4NUFMUN
Fascia Panel (Standard) PC4NUSKUN Construction
Insulated, HIPS chassis with a galvanized steel frame and fascia
External Contact Control MIM-B14 panel certified to UL94 V0.
Motion Occupancy Sensor MCR-SMC Heat Exchanger
Accessories External Temperature Sensor MRW-TA The heat exchanger shall be mechanically bonded fin to copper tube

Wireless Remote Controller AR-EH03U Indoor Fan


Indoor fan is a single turbo type
CN83 Pigtail (for 12VDC VENT output) DB39-01263A
Three fan speed settings and auto setting
MTFC - Multi-Tenant Function Controller MCM-C210N
Controls
MERV 13 Filter MF-C6A0 The unit shall be operated via a wireless or wired remote control with
DDC type signal
Safety Certifications ETL (UL 1995)
The unit shall integrate with the Samsung NASA Controls Network
1 Nominalcooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.
Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.
Solution
2A fascia panel is required for unit operation and is sold separately. PC4NUFMUN is required to use Wind-Free™ functions. Control wiring shall be 2 X 16 AWG shielded wire
* The Wind-FreeTM unit delivers an air current that is under 0.15 m/s while in Wind-Free™ mode. Air velocity that is
below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and Samsung HVAC maintains a policy of ongoing development, specifications are
Air-Conditioning Engineers). subject to change without notice.

© 2019 Samsung HVAC


www.SamsungHVAC.com
SHA-DVMS-11122019 888-699-6067
SUBMITTAL AM036NN4DCH/AA Page 2 of 2

Samsung DVM S Series, Wind-Free™ 4-Way Cassette

35 1/16 - 35 13/16" Ceiling Opening

28 15/16" Suspension Position 37 3/8"

35 1/16 - 35 13/16" Ceiling Opening


28 15/16" Suspension Position

37 3/8"
6
5 PC4NUFMUN Panel (ordered separately)

14 9/16"
33 1/16" 2 3/16"
7 1/4"
2 3/16" 3 11/16"
9 3/8" 2 3/8"
7 1/4"
2 3/4"
5 1/4"
1 9/6"

4 3/4"
8 7/16"
8 3/4"

9"
5"
3 13" 9 5/16" 4 1 2 6 1/2"
11 7/8" 13 13/16"

Ø 4" 3 1/8"
3 1/8"
6 3/4"
5 3/16"

1 7/8"

7
7 11/16"

re
or mo
m(59”) No. Name Description
1500m

1 Liquid Pipe Connection Ø 3/8" Flare


15
00
m
m
2 Gas Pipe Connection Ø 5/8" Flare
(5
9” Drain Pipe Connection
)o
rm
3 OD 1 1/4", ID 1"
15
or 00 Conduit for Power & Communication Wiring
e m
m
4 -
(5
9”
)o
rm
5 Air Inlet Grille -
or
e 6 Air Outlet Louver -
7 Fresh Air Intake Ø4"
re
or mo
m(59”)
1500m

Proper clearance must be maintained around unit for proper operation.

www.SamsungHVAC.com