requirements of Sec. 6.3.9.1 1c;, except tnat machines and their control equipment located
they may be fastened only to the entrance inside the hoistway enclosure. Access
frame. openings shall:
7.1.9 Overlap of Entrance Panels for Entrances, (a) be of adequate size and so located as to
Vertical Slide Type. The entrance panels permit required maintenance and inspection;
with their attachments shall overlap the
entrance frame and sill by not less than 12.7 (b) have a maximum width of 610 mm and
mm. maximum height of 610 mm.
73i
7.1.10 Hoistway-Door Locking Devices (c) be provided with doors which shall be kept
closed and locked.
a. For Power Dumbwaiters
7.2 Cars
1. At landings where the bottom of the
door opening 610 mm or more 7.2.1 Construction of Gars. Cars shall conform to 7A
above the floor, the hoistway doors the following requirements:
shall be provided with hoistway-unit- t.*1
system hoist-way door combination a. They shall be of solid openwork
mechanical locks and electric construction, and of such strength and
contacts. i
stiffness that they will not deform
appreciably when the load leans or falls
2. At landings where the bottom of the against the sides of the cars.
door opening is less than 610 mm
above the floor, the hoistway doors b. Non-metal cars sections shall be reinforced
shall be provided with hoistway-unit- with metal from the bottom of the car to the
system hoistway door interlocks. point of suspension.
118