Professional Documents
Culture Documents
Electrical Erection BOQ - LS MPS - Assof Infra
Electrical Erection BOQ - LS MPS - Assof Infra
IMPLEMENTING AGENCY
KMDA/WS/GAP/SE(N)/NIT-6/18-19 &
28 / SE (N)/GAP/W&S/KMDA of 2018-2019
CLIENT
-
CONCESSIONAIRE
REVISION HISTORY
A) ERECTION OF PANELS
Labour charges for shifting of Panels from the respective store/store –yard to work site with the help of Hydra & Crane (which is accessible in
site) & trained rigger, Placing /Erection of the same shall be done as per drawing in position with the help of Hydra/ Crane /Manual
Derrick/Chain-pully block /Other mechanical devices etc –(which is safer for erection and accessible to the site) & trained rigger. including
fabrication of frame work and painting of the same,alignment of the panel,interconnection of bus and control wiring, pre-commissioning and
commissioning of the same to the satisfaction of VA TECH
WABAG/client and all the test reports needs to be maintained, Incoming /Outgoing: As per SLD and panel wiring diagram .The rate includes
proper alignment as per procedure (including the supply of any kind consumeables and machineries) .
1 750 mm(L) X 1575 mm(D) X 2540 mm(H) 950 Kgs
11 KV CICO Panel
Rating : 3 Phase ,3 Wire, 11KV,50HZ,800A,20KA/3 Sec, No
Power Pack : 7HA, Input :230 V Ac,Output 24 V DC
2 750 mm(L) X 1575 mm(D) X 2540 mm(H) 950 Kgs
6 KV CICO Panel
Rating : 3 Phase ,3 Wire, 6KV,50HZ,800A,20KA/3 Sec, No 1
Power Pack : 7HA, Input :230 V Ac,Output 24 V DC
3 415 V LT PMCC With integreted APFC PANEL ,Incommer-1250A, and outgoing feeder as per SLD (APFC Rating : 150 KVAr) Location : Itchapur PS Location : Itchapur PS
Location : Itchapur PS 4250 mm(L) X 1050 mm(D) X 2075 mm(H) TS1: 230 Kgs
Transportation Section-1 : Length -1500 mm,Depth - 1000 mm,Height- 2075 mm TS2-150 Kgs
Transportation Section-2 : Length -1600 mm,Depth - 1000 mm,Height- 2075 mm TS3-180 Kgs
Transportation Section-3 : Length -1100 mm,Depth - 1000 mm,Height- 2075 mm
Type : Metallic Enclosure- Compartmetalized, Double Front, Fixed Type Feeder,Form-3B
Cable Entry: Bottom ,Dgree of Protection: IP-54
415 V LT PMCC With integreted APFC PANEL ,Incommer-1250A, and outgoing feeder as per SLD (APFC Rating : 200 KVAr) Location :Kona MPS
Location :Kona MPS Location :Kona MPS TS1: 230 Kgs
Transportation Section-1 : Length -1500 mm,Depth - 1000 mm,Height- 2075 mm 4750 mm(L) X 1050 mm(D) X 2075 mm(H) TS2-150 Kgs
Transportation Section-2 : Length -1700 mm,Depth - 1000 mm,Height- 2075 mm TS3-180 Kgs
Transportation Section-3 : Length -1500 mm,Depth - 1000 mm,Height- 2075 mm
Type : Metallic Enclosure- Compartmetalized, Double Front, Fixed Type Feeder,Form-3B
Cable Entry: Bottom ,Dgree of Protection: IP-54
Location :Hanuman Jute Mill-LS-1
415 V LT PMCC With integreted APFC PANEL ,Incommer-1250A, and outgoing feeder as per SLD (APFC Rating : 200 KVAr) TS1: 230 Kgs
Location :Hanuman Jute Mill-LS-1 TS2-150 Kgs
Transportation Section-1 : Length -1500 mm,Depth - 1000 mm,Height- 2075 mm Location :Hanuman Jute Mill-LS-1 TS3-180 Kgs No 1
Transportation Section-2 : Length -1800 mm,Depth - 1000 mm,Height- 2075 mm 4850 mm(L) X 1050 mm(D) X 2075 mm(H)
Transportation Section-3 : Length -1500 mm,Depth - 1000 mm,Height- 2075 mm Location :Matkhal MPS
Type : Metallic Enclosure- Compartmetalized, Double Front, Fixed Type Feeder,Form-3B TS1: 230 Kgs
Cable Entry: Bottom ,Dgree of Protection: IP-54 TS2-150 Kgs
TS3-180 Kgs
415 V LT PMCC With integreted APFC PANEL ,Incommer-1250A, and outgoing feeder as per SLD (APFC Rating : 200 KVAr) Location :Matkhal MPS
Location :Matkhal MPS 4850 mm(L) X 1050 mm(D) X 2075 mm(H)
Transportation Section-1 : Length -1500 mm,Depth - 1000 mm,Height- 2075 mm
Transportation Section-2 : Length -1800 mm,Depth - 1000 mm,Height- 2075 mm
Transportation Section-3 : Length -1500 mm,Depth - 1000 mm,Height- 2075 mm
Type : Metallic Enclosure- Compartmetalized, Double Front, Fixed Type Feeder,Form-3B
Cable Entry: Bottom ,Dgree of Protection: IP-54
415 V LT MCC With integreted APFC PANEL,Incommer-200A, and outgoing feeder as per SLD (APFC Rating : 30 KVAr) Location : CPT Land-IPS-2
Location : CPT Land-IPS-2 Location :CPT Land-IPS-2 TS1: 230 Kgs
Transportation Section-1 : Length -1100 mm,Depth - 500 mm,Height- 2075 mm 2300 mm(L) X 550 mm(D) X 2075 mm(H) TS2-150 Kgs
Transportation Section-2 : Length -1150 mm,Depth - 500 mm,Height- 2075 mm
Type : Metallic Enclosure- Compartmetalized, Single Front, Fixed Type Feeder,Form-3B
Cable Entry: Bottom ,Dgree of Protection: IP-54 Location : Round Tank-IPS-3
TS1: 230 Kgs
415 V LT MCC With integreted APFC PANEL,Incommer-315A, and outgoing feeder as per SLD (APFC Rating : 50 KVAr) Location Round Tank-IPS-3 TS2-150 Kgs
Location : Round Tank-IPS-3 3300 mm(L) X 650 mm(D) X 2075 mm(H)
Transportation Section-1 : Length -1200 mm,Depth - 600 mm,Height- 2075 mm
Transportation Section-2 : Length -2050 mm,Depth - 600 mm,Height- 2075 mm Location :Bally Khal -LS-3 No 1 1
Type : Metallic Enclosure- Compartmetalized, Single Front, Fixed Type Feeder,Form-3B TS1: 230 Kgs
Cable Entry: Bottom ,Dgree of Protection: IP-54 TS2-150 Kgs
415 V LT MCC With integreted APFC PANEL,Incommer-125A, and outgoing feeder as per SLD (APFC Rating : 20 KVAr) Location Bally Khal -LS-3
Location :Bally Khal -LS-3 2300 mm(L) X 550 mm(D) X 2075 mm(H)
Transportation Section-1 : Length -1100 mm,Depth - 500 mm,Height- 2075 mm
Transportation Section-2 : Length -1050 mm,Depth - 500 mm,Height- 2075 mm Location : Panchanantala-LS-4
Type : Metallic Enclosure- Compartmetalized, Single Front, Fixed Type Feeder,Form-3B TS1: 230 Kgs
Cable Entry: Bottom ,Dgree of Protection: IP-54 Location Panchanantala-LS-4 TS2-150 Kgs
2300 mm(L) X 550 mm(D) X 2075 mm(H)
415 V LT MCC With integreted APFC PANEL,Incommer-125A, and outgoing feeder as per SLD (APFC Rating : 20 KVAr)
Location :Panchanantala-LS-4
Transportation Section-1 : Length -1100 mm,Depth - 500 mm,Height- 2075 mm
Transportation Section-2 : Length -1150 mm,Depth - 500 mm,Height- 2075 mm
Type : Metallic Enclosure- Compartmetalized, Single Front, Fixed Type Feeder,Form-3B
Cable Entry: Bottom ,Dgree of Protection: IP-54
6 415 V LT MCC PANEL-Incommer-400A, and outgoing feeder as per SLD Location : Golabari-LS-6 Location : Golabari-LS-6
Location : Golabari-LS-6 2250 mm(L) X 550 mm(D) X 2075 mm(H) TS1: 230 Kgs
Transportation Section-1 : Length -2000 mm,Depth - 600 mm,Height- 2075 mm TS2-150 Kgs
Transportation Section-2 : Length -500 mm,Depth - 600 mm,Height- 2075 mm
Type : Metallic Enclosure- Compartmetalized, Single Front, Fixed Type Feeder,Form-3B
Cable Entry: Top ,Dgree of Protection: IP-54
Location : Arupara MPS
415 V LT MCC PANEL-Incommer-1000A, and outgoing feeder as per SLD Location :Arupara MPS TS1: 230 Kgs
Location : Arupara MPS 2650 mm(L) X 1050 mm(D) X 2075 mm(H) TS2-180 Kgs
Transportation Section-1 : Length -1600 mm,Depth - 1000 mm,Height- 2075 mm
Transportation Section-2 : Length -1000 mm,Depth - 1000 mm,Height- 2075 mm
Type : Metallic Enclosure- Compartmetalized, DoubleFront, Fixed Type Feeder,Form-3B
Cable Entry: Bottom ,Dgree of Protection: IP-54 Location : Belur Math-LS-2
Location : Belur Math-LS-2 TS1: 230 Kgs
415 V LT MCC PANEL-Incommer-400A, and outgoing feeder as per SLD 2600 mm(L) X 850 mm(D) X 2075 mm(H) TS2-180 Kgs
Location : Belur Math-LS-2
Transportation Section-1 : Length -1200 mm,Depth - 800 mm,Height- 2075 mm
Transportation Section-2 : Length -1350 mm,Depth - 800 mm,Height- 2075 mm
Type : Metallic Enclosure- Compartmetalized, DoubleFront, Fixed Type Feeder,Form-3B Location : Belur Math-LS-2 No 1
Cable Entry: Bottom ,Dgree of Protection: IP-54 TS1: 230 Kgs
Location : Saltgola-LS-5 TS2-180 Kgs
415 V LT MCC PANEL-Incommer-200A, and outgoing feeder as per SLD 2700 mm(L) X 550 mm(D) X 2075 mm(H)
Location : Saltgola-LS-5
Transportation Section-1 : Length -1100 mm,Depth - 500 mm,Height- 2075 mm
Transportation Section-2 : Length -1550 mm,Depth - 500 mm,Height- 2075 mm
Type : Metallic Enclosure- Compartmetalized, Single Front, Fixed Type Feeder,Form-3B
Cable Entry: Top ,Dgree of Protection: IP-54
2 6 /0.433 KV ,800 KVA oil type Transformer with OLTC and RTCC panel Transformer with OLTC:
Vector Grope: Dyn11 3395 KG Approx/unit
Tappings on winding on HV side: ON-Load Tap Changer RTCC Panel: 150 KG/Unit
Number of Steps : 8 steps9 PositionRange of tappings for variation : +5% to -15% @2.5 %
Losses(KW) : No load Loss : 1450 Watts, Load Loss: 9000 Watts
Positive sequence impedance on rated MVA base at rated current and Transformer with OLTC:
frequency at 75 deg C.winding temperature at Principle tap precent : :5 % 2600 mm(L) X 2600 mm(D) X 2200 mm(H)
Efficiency at full load percent at 0.8 P.f : 98.39% RTCC Panel: Set 1
Type of cooling : ONAN 600 mm(L) X 600 mm(D) X 2200 mm(H)
Mass of Oil : 810 Kgs
Vol. of Oil : 980 Ltr
4 SPDB Panel (SUB- POWER DB) 600 mm(L) X 200 mm(D) X 400 mm(H) 80 Kgs
Cable Entry: Bottom ,Dgree of Protection: IP-54 No 1
G) HT CABLE TERMINATION
HT Cables end Termination along with suitable termination kit -including proper insulation,, Meggaring, testing, commissioning
complete to the satisfication(HT termination kit will be Supply By WABAG)
Pre-commissioning and commissioning of the same at different location (indoor + outdoor )of the plant , to the satisfaction of VA TECH
WABAG/client and all the test /reports needs to be maintained. The rate includes proper erection and testing as per procedure (including the
supply of any kind consumeables and machineries req for completion of work to the satisfactory of VA TECH / Client )
1 11 KV HT Termination Kit
suitable for Cable Size : 1C X 500 Sq.mm
Type: A2XCeWaY
Voltage Grade : 11 /!!KV (UE)
2 6.6 KV HT Termination Kit
suitable for Cable Size : 1C X 630 Sq.mm
Type: A2XCeWaY Nos 12
Voltage Grade :6.6 KV/6.6 KV (UE)
H)LV CABLE TERMINATION
Termination of Cables along with Double Compression Cable Glands, along with terminations of Lugs at Motor / PBS / Socket
Outlets/ Light Fittings/Elect. Eqpt. end including proper insulation,printed tubular ferule, Meggaring, testing, commissioning
complete to the satisfication(Gland shall be Supply By WABAG)
Pre-commissioning and commissioning of the same at different location (indoor + outdoor )of the plant , to the satisfaction of VA TECH
WABAG/client and all the test /reports needs to be maintained. The rate includes proper erection and testing as per procedure (including the
supply of required size of cable lugs ( power and control cables) and any kind consumeables and machineries req for completion of work to the
satisfactory of VA TECH / Client )
Cable Gland and Terminations
1
Weatherproof Type Double
Compression Cable Gland Suitable for Nos
Cable Size: 3.5C x 400
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 64
2
Weatherproof Type Double
Compression Cable Gland Suitable for Nos 16
Cable Size: 3.5C x 300
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 60
3
Weatherproof Type Double
Compression Cable Gland Suitable for Nos
Cable Size: 3.5C x 150
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 42
4
Weatherproof Type Double
Compression Cable Gland Suitable for Nos 8
Cable Size: 3.5C x 120
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 40
5
Weatherproof Type Double
Compression Cable Gland Suitable for Nos 4 4
Cable Size: 3.5C x 95
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 37
6
Weatherproof Type Double
Compression Cable Gland Suitable for Nos 16
Cable Size: 3C x 300
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 51
7
Weatherproof Type Double
Compression Cable Gland Suitable for Nos
Cable Size: 3C x 150
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 39
8
Weatherproof Type Double
Compression Cable Gland Suitable for Nos 6
Cable Size: 3C x 120
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 36
9
Weatherproof Type Double
Compression Cable Gland Suitable for Nos
Cable Size: 3C x 70
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 29
10
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 3C x 35 Nos
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 24
Accessories : Shrouds
11
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 3C x 25 Nos 4
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 23
Accessories : Shrouds
12
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 3C x 10 Nos
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 20
Accessories : Shrouds
13
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 4C x 4 Nos 6 4 4 2
Cable Type : 2XWY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 17
Accessories : Shrouds
14
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 3C x 4 Nos 2 16 18
Cable Type : 2XWY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 16
Accessories : Shrouds
15
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 4C x 2.5 Nos 2
Cable Type : 2XWY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 16
Accessories : Shrouds
16
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 3C x 2.5 Nos 22 14 14 14
Cable Type : A2XFY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 15
Accessories : Shrouds
17
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 3C x 4 Nos 4
Cable Type : 2XWY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 16
Accessories : Shrouds
18
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 4C x 2.5 Nos 6 2 2 2
Cable Type : 2XWY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 16
Accessories : Shrouds
19
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 10C x 2.5 Nos 8
Cable Type : 2XWY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 21
Accessories : Shrouds
20
Weatherproof Type Double
Compression Cable Gland Suitable for
Cable Size: 12C x 2.5 Nos 10 10 10 10
Cable Type : 2XWY
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) : 23
Accessories : Shrouds
21
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 4 4
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
(7.5 KW & KW : 15)
Power Cable : 1R x 4C x 1.5Sq.mm
22
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 6 6
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
(7.5 KW & KW : 15)
Power Cable : 1R x 3C x 1.5Sq.mm
23
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
(22 KW & KW : 30)
Power Cable : 1R x 4C x 4Sq.mm
24
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 4
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
(22 KW & KW : 30)
Power Cable : 1R x 3C x 4Sq.mm
25
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 37
Power Cable : 1R x 4C x 6Sq.mm
26
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 37
Power Cable : 1R x 3C x 6Sq.mm
27
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
(45KW & KW : 55)
Power Cable : 1R x 4C x 10Sq.mm
28
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
(45KW & KW : 55)
Power Cable : 1R x 3C x 10Sq.mm
29
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 3
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 75
Power Cable : 1R x 4C x 16Sq.mm
30
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 3
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 75
Power Cable : 1R x 3C x 16Sq.mm
31
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 90
Power Cable : 1R x 4C x 25Sq.mm
32
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 90
Power Cable : 1R x 3C x 25Sq.mm
33
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 2
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 132
Power Cable : 1R x 4C x 35Sq.mm
34
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 2
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 132
Power Cable : 1R x 3C x 35Sq.mm
35
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 200
Power Cable : 1R x 4C x 95Sq.mm
36
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 200
Power Cable : 1R x 3C x 95Sq.mm
37
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 3
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 250
Power Cable : 1R x 4C x 120Sq.mm
38
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 3
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
KW : 250
Power Cable : 1R x 3C x 120Sq.mm
39
Nylon Type Cable Gland Suitable fo
Cable Size:
Cable Type: YY Nos 5 5 5 5
Appr. Overall Dia. of Cable (tolerance +/- 2mm)(mm) :
All rating Start from 7.5 KW to 250 KW
Power Cable : 1R x 15C x 1.5Sq.mm
7 Earth electrode
40mm dia 3000 mm long heavy Duty G.I. pipe electrode Nos 6 6 6 6
8 75 x 10 mm GI flat Mtr 243 222 206 206
9 Earth electrode 40mm dia 3000 mm long heavy Duty G.I. Pipe with 600 x 600 x 6 mm GI plate for Plate earthing Nos 4 2 2 2
10 25 x 6 mm GI flat Mtr 30
Lightning Systems
1 25 x 3 mm GI flat Mtr 76 45 43 39
2 1.5M long lightning spike with all accessories Nos 2 2 2 2
3 TEST LINK SUITABLE FOR (25X3mm GI.FLAT) Nos 2 2 2 2
4 2METER LONG,20MM DIA. Cu AIR TERMINATION ROD WITH MOUNTING ASSEMBLY (SUITABLE FOR 25X3MM GI. FLAT) Nos 1 1 1 1
5 Fixing of Insulator - suitable for Lightning Arrester GI strip for 25x3 mm with required size of M8 x 50 mm long anchor fastner and
M8 x 15 mm long GI Bolt with double washers
Nos 102 61 58 52
15 RUBBER MAT - PUMPING STATION 1) Location : Golabari-LS-6 : SIZE 2550 mm(L) X1000MM (W)
APFC Panel - Safety Rubber Mat - 415 KV As per IS : 15652 : 2006 2) Location : Belur Math-LS-2 : SIZE 2600 mm(L) X1000MM (W) No 1
Colour : Black 3) Location : Saltgola-LS-5 : SIZE 2700 mm(L) X1000MM (W)
23 Installation of Cable marker over ground for UG HT cables at all bends,loops,joints, crossing points and at every 25 Meterintraval on stright runs.
MOC: Galvanised Cast Iron
Size : 200mm x 100MM x 5mm Thickness
Colour of plate back ground and lettering – yellow colour with Black colour Letters
75mm L angle Support with Nuts & Bolt to the plate burring it. Height of the angle should be – 700mm height
Cable markers shall be anchored in the ground at a depth of minimum 500mm
Message on each plate- Example Nos 5
6kV HT cable Depth @ 1000mm depth (30mm size letters)
24 Installation of Cable marker over ground for UG LT cables at all bends,loops,joints, crossing points and at every 25 Meterintraval on stright runs.
MOC: Galvanised Cast Iron
Size : 200mm x 100MM x 5mm Thickness
Colour of plate back ground and lettering – yellow colour with Black colour Letters
75mm L angle Support with Nuts & Bolt to the plate burring it. Height of the angle should be – 700mm height
Cable markers shall be anchored in the ground at a depth of minimum 500mm
Message on each plate- Example Nos 16 16 16
415V HT cable Depth @ 1000mm depth (30mm size letters)
Spreading of sand
1 As per the underground cable routing - requied sand bedding to be done ( Supply of sand will be under the Wabag Scope of Supply)
Cu.M 10000
Laying of cable protective cover
1 Laying of cable protective cover ( made of Reinforced concreate ) for HT Cable Nos 500
( Supply of sand will be under the Wabag Scope of Supply)
2 Laying of cable protective cover ( made of Earthenware ) Brick for LT cable Nos 20000
( Supply of sand will be under the Wabag Scope of Supply)
M) ERECTION OF LOCAL CONTROL PANEL FOR PUMPS WITH SUPPORTS
Labour charges for shifting of Local control panel for pumps from the respective store/store –yard to work site.
Placing/Erecting the same (including the fabrication , erection and painting of support ) and cable termination .
Pre-commissioning and commissioning of the same at different location (indoor + outdoor )of the plant , to the satisfaction of VA TECH
WABAG/client and all the test /reports needs to be maintained. The rate includes proper erection and testing as per procedure (including the
supply of any kind consumeables and machineries req for completion of work to the satisfactory of VA TECH / Client )
1 1
1 1 3
1 1 1 4
1 1 1 1 1 8
1 1 1 5
1 1 1 4
1 1 3
1 1
1 1 3
2
1 1 2
1 1
1 2
1 2
1 1
1 1
1 1 1 1 1 1 1 1 1 13
1 1 1 1 1 1 1 1 1 13
1 1 1 1 1 1 1 1 1 13
1 1 1 1 1 1 1 1 1 13
1 1 1 4
150 150
3200 3200
50 50
50 100 250
100
75 50 50 250
75 75 150
50 50 100
75 125
150
150 300
50 50 75 75 40 40 40 65 45 680
25 25 25 100
175 175 275 275 175 200 200 250 150 2675
25 25 50 150
25 25 75 75 25 25 25 75 500
125 125 125 125 125 150 150 100 100 1625
12 12
12 12 36
16 16
16 16 4 4 16 72
4 4
4 8 20
16 16 48
8 8 16
6 4 4 20
6 6 12
4 4 8
6 10
12 12 24
4 4 6 6 4 4 4 6 4 58
8 2 2 12 2 62
2 2 2 8
14 14 22 22 14 16 16 20 12 214
2 2 4 12
2 2 6 6 2 2 2 6 40
8 8 8 32
10 10 10 10 10 12 12 8 8 130
4 6 22
6 6 12
6 10
2 2 4
2 2 4
6 6
6 6
3 6
3 6
2 2 4
2 2 4
2 2 6
2 2 6
2 2 4
2 2 4
3 3 9
3 3 9
5 5 5 5 5 6 6 4 4 65
30 30 30 30 150
20 20 20 20 100
55 25 25 25 25 55 55 25 25 435
20 80
40
25 25 25 25 25 25 25 25 25 325
6 6 6 11 6 6 6 6 6 83
201 214 248 285 265 255 247 283 259 3134
2 2 4 4 2 2 2 4 32
50 50 30 160
1 1 1 1 1 1 1 1 1 13
1 1 1 1 1 1 1 1 1 13
1 1 1 1 1 1 1 1 1 13
1 1 1 1 1 1 1 1 1 13
2 2
2 2 6
2 2 2 2 2 2 2 2 2 26
1 1 1 1 1 1 1 1 1 13
1 1 1 4
1 1 1 1 1 1 1 1 1 13
1 1 1 4
1 1 1 4
1 1 1 4
1 1 1 4
1 1 1 4
1 1 1 1 6
1 1 3
1 1 1 1 1 1 1 1 1 13
0.3 0.3 1.2 1.2 0.6 0.6 0.6 1.2 1.2 8.7
0.1 0.1 0.4 0.4 0.2 0.2 0.2 0.4 0.4 2.9
1000
1520
1 1 1 1 1 1 1 1 1 13
1 1 1 1 1 1 1 1 1 13
1 1 1 1 1 1 1 1 1 13
5 5
5 5 15
16 16 16 16 16 16 144
2 8
3 3
3 3 6
3 5
2 2
2 2
3 3
3 3
3 6
2 2 4
2 2 6
2 2 4
3 3 9
Supply of Lugs Details
S. No Description Unit QTY
1 400 Sq.mm AL.Ring Type Lugs Nos 48
2 300 Sq.mm AL.Ring Type Lugs Nos 360
3 185 Sq.mm AL.Ring Type Lugs Nos 16
4 150 Sq.mm AL.Ring Type Lugs Nos 132
5 120 Sq.mm AL.Ring Type Lugs Nos 183
6 95 Sq.mm AL.Ring Type Lugs Nos 56
7 70 Sq.mm AL.Ring Type Lugs Nos 56
8 50 Sq.mm AL.Ring Type Lugs Nos 8
9 35 Sq.mm AL.Ring Type Lugs Nos 66
10 25 Sq.mm AL.Ring Type Lugs Nos 58
11 16 Sq.mm AL.Ring Type Lugs Nos 42
12 10 Sq.mm AL.Ring Type Lugs Nos 114
13 6 Sq.mm AL.Ring Type Lugs Nos 28
14 4 Sq.mm CU.Ring Type Lugs Nos 542
15 2.5 Sq.mm CU.Ring/PIN Type Lugs Nos 2714
16 1.5 Sq.mmCU Ring/PINType Lugs Nos 1073
Total 5496
Special Terms & Conditions
1
2
3
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
33
Special Terms & Conditions
Construction Power shall be provided by Wabag at one place but on a chargeable basis at per DISCOMs rates.Further distributi
distribution board etc.,
Water shall be provided by Wabag.
PF & ESI to be arranged by Vendor
Site Safety is in the scope of vendor and this must be maintained meeting all requirements without any compromise.
Safety signage and caution tape and other necessary arrangement to made by contractor.
Major scope of work as a minimum covers, Identification of equipment/ materials at stores / storage yard,technical assistance
stores / storage yard, as received from manufacturer will be handed over to you at our site stores, removal of packing if any, in
designated work areas from our stores, assembly, erection / installation of various Electrical/ Instrumentation works, etc for p
along with all consumables, tools and tackles, testing as per Wabag Engineer’s Instruction / Supervision and providing assistan
shooting, trial operation of the complete equipment
Rate is inclusive of hydra/crane for shifting and erection of panels wherever applicable.
All steel works including chequered plates cutting will be done by grinder or choksa machine. All the holes to be done through
flame cut is allowed.
Two coats of primer & 2 coats of Finished paint to be done by Vendor , the paint will be provided by Wabag as free supply.
Making holes in panels thorough holesaw cutter shall be a part of glanding no additional price is allowed.
For lighting works any chipping come in brick wall will be done by vendor
Anchor fastners for supports shall be included in structural works prices. The anchor fasteners will be provided by Wabag as a
Consumables like welding electrode , gas for cutting, drill bit, grinding wheel, insulation tape, Teflon tape, hexa blade,PVC slee
tagging,including the supply of required size of cable lugs for Power and control cables , Printed ferruls,cable ties, cable tags
dressing materials such as clamps , bricks,Cement, sand excavation (for earth pit only) materials etc.
Any work not mentioned in scope of work (BOQ provided by Wabag) required to be done shall be treated as an extra works aft
Fabrication of cable tray bends shall be included in cable tray erection price.The Cable tray will be provided by Wabag as a f
Cable trench Earth excavation & back filling shall be included in cable laying price.
Vendor shall submit reconciliation statement at least once in a month or with each RA Bill for the free issue materials .
All Equipment Testing & Transformer oil filtrationto be done by vendor
All the erection procedure to be adopted based on the Wabag engineer or consultant recommendation.
Commissioning assistance including machinery and manpower shall be provided by vendor with 2 skilled manpower
for 45 days or till project completion
Vendor shall depute a dedicated qualified Site In Charge, Planning Engineer, Supervisory personnel and crew
personnel including quality control personnel’s shall be made available at site during execution.
Vendor shall furnish daily manpower / equipment report and other information as may be required.
All necessary licences / certifications as may be required to carry out the scope of work.
Construction methodology/quality assurance plan / rigging plan and necessary inspection procedures / documents shall be su
Consultant / Client for approval after award of contract within one week. Only after approval/ clearance of the above, contrac
at site.
Venor shall adopt All statutory and other compliances as per West bengal law
Inspection will be by VA Tech Wabag / Consultant Inspectors and shall have full access to contractor’s work. The work shall be
satisfaction of VA Tech Wabag / Consultant/End user.
Vendor shall perform all works as per good standard engineering practice and guidelines of the relevant IS
Vendor should arrange Personnel Protective Equipment (PPE) for crew, supervisor & Engineer engaged in the job, non complia
penalty as per company policy.
Any damages to the equipments during erection and other permanent equipments in this project, contractor shall take efforts
over to us in its original condition.
Payments shall be made for the actual quantities executed for the work done & certified by our Site engg/RCM/PM
All necessary qualified skilled / unskilled labors,Staffs etc. Adequate manpower shall be mobilized to ensure completion of the
speed up the progress.
Vendor shall ensure that all necessary test certificates shall be made available for all equipments, tools & tackles that are used
House keeping of the respective areas of work , will be in vendor scope.