Professional Documents
Culture Documents
Aec Catalog 2022
Aec Catalog 2022
CATALOG
2022
WWW.AECUPS.COM
2
AEC Group
Our history 06
Our services 10
Our solutions 12
CPSS EN50171 52
Accessories 60
ABOUT
AEC
OUR VISION
The AEC group is an innovative multinational
company and at the forefront of the infrastructure
sector critical electrical and renewable energy and
53 695 11
arises the aim is to improve the quality of the Years of experience Employees Offices
life of citizens and workers.
AEC GROUP
OUR HISTORY
Allis Electric Corporation, better known as AEC, was founded
on September 25, 1968, in the capital of Taiwan, Taipei.
The company started the business by producing low voltage
switchboards, motor control centers, integrated high starter panels
and low voltage, AC / DC industrial control equipment and
transmission and distribution equipment. Its constant activity of
expansion led to the development of independent departments
which produce transformers, switching devices and
subsequently various products in the electronics sector of power.
Through investments, joint ventures and the creation of offices
abroad in Europe, the United States and China, AEC continues to
develop alliances strategic business in order to pursue excellence
such as multinational corporate group. With the confidence
provided through over 53 years of solid performance and in-depth
From 1968.... knowledge, AEC will continually work on his core competencies
to be increasingly customer-oriented and to create values for its
shareholders.
Founded in 1968, the AEC group,
Allis Electric Co. Ltd, is a public company
Listed on the Taipei Stock Exchange since
In 2021 the group, headquartered in Taipei, counts
1994.
4 official branches and 11 offices with service centers
Global leader in the field of
highly specialized and available 24/7.
critical electrical infrastructures, digital
Spare parts stocked in over 21 countries.
and telecommunications, the AEC group
has been specializing in the production
of uninterruptible power supplies for the
Products manufactured and marketed by us can
protection of the power supply of
be supported and assisted anywhere in the world, the
industrial installations.
our network of offices allows us to cover whatever
Technology and design come together
time zone and almost all countries in the world.
to create continuity systems cutting-edge,
robust and efficient.
In 1994, the AEC group, now a solid reality with over 30 years of
experience, it is listed on the Taipei stock exchange through an offer
public launch that was hugely successful.
Stock exchange listing and strategic alliances with partners
Europeans have allowed it to continue its steady growth
and to venture into the telecommunications and high-end sector
technology, designing and developing products qualitatively
without equal.
All products manufactured by AEC are guaranteed by certificates
ISO 9001 quality, ensuring customers the utmost seriousness
production and reliability over time.
Our history
The AEC group, Allis Electric Co., has been listed on the Taipei Stock Exchange
since 1994.
Our company has a capitalization of over 100 million dollars and a staff of 695
employees located in 4 main commercial and production sites located in Italy,
Taiwan, USA and South Africa.
FINANCIALS
AEC GROUP
Constancy, attention to detail and attention to the
customer are just some of our pillars.
From 1968 to today ... $184 MILIONS
TURNOVER IN 2021
AEC was originally a supplier of OEM machinery to manufacturers Critical Power: production and sale of UPS &
Italians and Europeans who use their own brand, while today AEC CPSS continuity systems, and lead or lithium
promotes its brand as a leading manufacturer in the industry e battery storage systems.
for some years it has delocalized and diversified its production which Renewable energies: among the first
it is not only Asian, but it is present with several factories in the designers of photovoltaic inverters, AEC
States United and in Italy to meet the needs of different markets is today an important player in the world
locals. of solar, marketing string and storage PV
inverters for residences and industries.
This continuous improvement process, as well as having an Electrical Mobility: to meet the looming
advantage direct and beneficial on sales and after-sales assistance need to transit from fossil fuel to electric
sale, strengthen the reputation of AEC as of more and more a vehicles, we are committed to offering a
serious, dynamic company attentive to technological progress e wide range of charging stations for electric
qualitative, always in total harmony and respect for the environment. vehicles.
200 Mln $
150 Mln $
100 Mln $
50 Mln $
2021 was one of AEC’s best Expanding markets, AEC in Our passion, our core business
years maximum expansion
Despite all the difficulties The numbers speak for Always the main core business of
due to the pandemic it has themselves! AEC, the world of UPS is giving
hit our planet, the AEC group + 42% UPS sales great satisfaction in terms of
managed to conclude one of the + 27% sales of PV solar inverters growth and our group persists
best years ever, reaching over 184 + 31% sales of 12V batteries in increasing its market share,
million dollars in global turnover. The AEC group continues its especially in the Italian national
growth and increases sales of market.
all 3 of its departments.
10
Our services
OUR
SERVICES
Our team of dedicated experts is always available to evaluate and analyze the infrastructures on which the customer’s reality
operates. Our company offers a very varied and complete range of services, our specialized technicians are able to support our
customers’ projects in all their aspects, from design, to implementation and maintenance.
Design and engineering consultancy, installation of UPS and PV Inverter devices, maintenance of critical infrastructures, lead-
acid battery changes and diesel generator tests, are just some of the services that AEC carries out daily for various customers
throughout our peninsula.
360 degree advice on any Our call center is available 24 hours Technicians located throughout the
critical infrastructure and facilities for per day also on WhatsApp or via peninsula Italian are available for
renewable energies. Our engineers our Live Chat on the aecups.com website. support after-sales interventions. In
they specialize in the study of Our operators will reply to synergy with our call center, the
feasibility and design of structures any of your doubts and they will be our service of technicians will be able
for data centers and photovoltaic able to direct you to the products to provide quick assistance by telephone
systems from scratch or to be restored. best suited to your needs. or through on-site intervention.
Our services
Surveys and UPS installations for Assistance is one of the flagships Maintenance is very important
critical infrastructure. AEC technicians of the AEC group, which offers its of the electronic devices installed, for
are highly qualified for installations of customers a continuous service thanks this AEC makes various available
UPS and battery cabinets of various to which it is always possible to find a maintenance programs and contracts,
brands of UPS manufacturers. technician and solve problems around with the ability to customize
Commissioning and verification of all the clock. AEC always aims to obtain the assistance according to the needs of the
device values and parameters. maximum customer satisfaction. customer and user.
OUR
SOLUTIONS
Ad hoc customized solutions based on the specific requests of the user, meticulous design and feasibility study for all projects
carried out by AEC. We are well aware that there is no longer a standard solution to all situations, and for this reason AEC has
always been dedicated to the development of innovative solutions based on customer feedback.
Our team will follow you step by step in choosing the most advantageous solutions to your situation!
AEC has always focused on While most fossil raw materials With over 53 years of experience
research and development of are being depleted, electricity in the power electronics sector
new technologies and, especially and energy needs are increasing and more than 30 in the renewable
in recent years, has invested in all countries of the world. The energy sector, the AEC group has
heavily in the development of scarcity of materials and the leveraged and put its expertise
modular UPS with innovative rising cost of electricity are more into play to develop and build a
hot-swappable N + 1 technology. than ever global struggles for wide range of charging stations for
New powers also available in which our group is constantly electric vehicles. , available in both
a single 1250kVA UPS solution working on innovative solutions alternating current and super fast
with 10 125kW modules. UPS, with low environmental impact. direct current modes. Our range
uninterruptible power supplies, Our aspiration is to incentivize of EV solutions is able to support
are the main business of AEC, and promote renewable and the most varied needs in terms
which thanks to its significant ecological energies in a significant of power needed, installations in
investments has always managed and incisive way. For this reason private or public environments,
to offer products of the highest we develop ever more efficient such as hospitality or healthcare
quality and reliability. Among the technologies and systems. facilities, shopping and recreation
most advanced technologies in the As a diversified industrial group centers, companies, congress
world of power electronics, AEC with extensive engineering centers, public car parks and large
uses the 3-level IGBT topology capabilities, AEC provides state- supermarkets.
with redundant components, of-the-art products, services and
guaranteeing maximum reliability solutions to meet the insatiable
also through an extended 3-year growing energy needs around the
warranty, which can be extended world.
by means of a maintenance
contract at our service centers.
authorized.
13
Nowadays the use of data centers in the productive world is growing dramatically as they are of fundamental
importance to support the continuous technological development of our planet. If until a few decades ago the
interruption of the operation of a data center would not have caused great inconvenience, today we must always
remain vigilant and ready to intervene in the event of system failure.
For this reason, UPS uninterruptible power supplies are an indispensable element for the correct and continuous
operation of data centers and there are several factors to consider when evaluating the type of UPS to install.
15
CRITICAL POWER
UPS, CPSS & BATTERIES
22
UPS Online single-phase rack IST3J 1-10kVA
30
UPS Online three phase rack IST9 10-20kVA
ADVANTAGES:
• LCD screen to check all information relating to operation;
• Line interactive with switching time <6 msec;
• Equipped with both Schuko and IEC sockets;
• USB communication port and RJ45 protection;
• Starting from batteries without mains present;
• SMT board technology;
• Protection against lightning, spikes and high frequency disturbances;
• Short circuit protection.
TECHNICAL SPECIFICATIONS
ENVIRONMENT CONDITIONS
TEMPERATURE -5 ~ +40° C
HUMIDITY < 90%
NOISE <45dBA @ 1 mt
STANDARDS AND CERTIFICATION CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
1:1
The UPS are available in models with internal batteries or combined with external
battery cabinets for longer runtimes. The 6kVA and 10kVA UPSs include the manual
bypass disconnector to allow correct maintenance without interrupting the output.
The USB card is included and the product range is covered by a 3-year warranty.
The UPS comply with the CEI 0-16 standard.
PRINCIPALS FEATURES
EXCELLENT PERFORMANCE
• Output power factor equal to 1 for a better load capacity • In compliance with the CEI-016 standard, the Charge
at the same power with lower and more convenient reserve function allows the batteries to maintain an
initial investment costs; energy reserve to always guarantee the rearming of the
coil and the restoration of full functionality of the cabin;
• Efficiency AC\AC up to 96%;
Efficienza
• Advanced DSP digital control technology for precise and
100,00% speed data processing;
97,50%
• Detection and warning of faults to ensure the safety of
the device, also monitoring the internal temperature of
the UPS;
95,00%
92,50%
• Intelligent fans with high efficiency cooling, multiple
90,00% modes to control their speed, extend their life and
improve their efficiency.
0% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Carico
• Output 208/220/230/240 Vac, 50 / 60Hz voltage, • NC \ NO dry contact card for alarms (optional).
configurable from on-site display;
WARRANTY
ASSISTANCE
IST3 1 KVA
20
EPO emergency release
Label
2 x Socket Schuko
Fan
Fan
USB\SNMP\Contact card
RS232
Label
Wheels
IST3-L 6-10 KVA
USB\SNMP\Contact card
RS232
Label
Ventilation grid
TECHNICAL SPECIFICATIONS
LCD DISPLAY Voltage and Frequency input/output, Load level protected, State charge of the batteries, Temperature, UPS operation and Block/Fault
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
1:1
The UPS are available in models with internal batteries or combined with external
battery rack cabinets for longer autonomy. Our 2kVA and 3kVA models have the hot-
swappable battery pack which facilitates quick replacement. The 6kVA and 10kVA
models have the advantage of occupying only 2U. The USB card is included and the
UPS are covered by a 3 year warranty.
PRINCIPALS FEATURES
EXCELLENT PERFORMANCE
• Output power factor equal to 1 for a better load capacity • Small footprint of only 2U even for 6 and 10kVA models;
at the same power with lower and more convenient
initial investment costs; • Possibility of installation in 19-inch rack or tower;
• Efficiency AC\AC up to 96%; • Advanced DSP digital control technology for precise and
Efficienza
rapid data processing;
100,00%
STANDARD E COMMUNICATIONS
• Output 208/220/230/240 Vac, 50 / 60Hz voltage, • Maintenance bypass rack module (optional);
configurable from on-site display;
• ECO mode configurable from on-site display; • SNMP network card for remote control and monitoring
(optional);
• 16 \ 17 \ 18 \ 19 \ 20 battery configuration via RS232
port (6-10kVA); • NC \ NO dry contact card for alarms (optional).
WARRANTY
ASSISTANCE
24
IST3-J 1 KVA
TECHNICAL SPECIFICATIONS
OTHER SPECIFICATIONS
RS232+EPO+USB (slot)
COMMUNICATIONS
(SNMP, RS485+ optional dry contact card)
LCD DISPLAY Voltage and Frequency input/output, Load level protected, State charge of the batteries, Temperature, UPS operation and Block/Fault
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
1:1
The lithium UPS units are available in models with internal batteries or combined with
external battery cabinets for longer runtimes. The IST8 UPS is capable of withstanding
temperatures up to 60 ° without risking damage to the batteries.
5-year battery warranty.
PRINCIPAL FEATURES
LITHIUM ION BATTERIES
• Output power factor equal to 1 for a better load capacity • In addition to being much lighter and less bulky,
at the same power with lower and more convenient lithium-ion batteries are also much more versatile
initial investment costs; and advantageous thanks to their ability to operate in
extremely cold temperatures.
• Integrated lithium-ion batteries, weight reduction up to Maximum operation at -20 ° C and up to + 50 °
40% compared to traditional lead-acid VRLA batteries, C, without any risk of damage o downgrading of
maximum discharge capacity up to 80% and an expected performance;
life of 15 years and over 1500 charging cycles;
• Possibility of installation in 19-inch rack or tower;
• Wide input tolerance, compatible with diesel generators; • Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
improve their efficiency.
• Output 208/220/230/240 Vac, 50 / 60Hz voltage, • Maintenance bypass rack module (optional);
configurable from on-site display;
• ECO mode configurable from on-site display; • SNMP network card for remote control and monitoring
(optional);
• RS232 and USB communication ports equipped with user • NC \ NO dry contact card for alarms (optional).
manual, cable and CD for software;
WARRANTY
ASSISTANCE
BUILT-IN LITHIUM-ION BATTERIES
EXCELLENT PERFORMANCE
• Output power factor equal to 1 for a better load • Small footprint of only 2U with autonomy of over 15
capacity at the same power with lower and more minutes from internal battery;
convenient initial investment costs;
• Possibility of installation in 19-inch rack or tower;
• Efficiency AC\AC up to 96%;
• Advanced DSP digital control technology for precise and
speed data processing;
Efficienza
100,00%
TECHNICAL SPECIFICATIONS
MODELS IST8010-LI IST8020-LI IST8030-LI
INPUT
VOLTAGE (VAC) 120-295
FREQUENCY (HZ) 50/60± 10% (50/60Hz)
POWER FACTOR ≥0.99
THDI <5%
OUTPUT
POWER (W/VA) 1000/1000 2000/2000 3000/3000
MAX. AC/AC EFFICIENCY 92.7% 93.5% 96%
POWER FACTOR 1
VOLTAGE (VAC) 208/220/230/240±1%
FREQUENCY (HZ) 50/60±0.1
THD <3%
SWITCHING TIME (MS) 0
ECO MODE SÌ
OVERLOAD 101%~115% per 1 min, 116%~133% per 1 s, < 134% per 200ms
BATTERIE AGLI IONI DI LITIO
VOLTAGE (VDC) 24 48 72
BACKUP TIME (MIN) 11 11 11
MAX. CHARGING CURRENT (A) 4
ALTRE SPECIFICHE
COMMUNICATIONS USB and SNMP (slot) (RS232+ Optional dry contact card)
OUTPUT SOCKETS (8) 5-15R (6) 5-20R (4) 5-20R + (1) L5-30R
DISPLAY LCD
PROTECTIONS Low batteries, Overload, Short-circuit, Over-temperature, ecc.
NOISE (DB) < 55
TEMPERATURE 0°C~60°C
HUMIDITY 0 ~ 95%
DIMENSIONS (L×W×H) (MM) 438×420×87 438×570×87 438×570×87
WEIGHT (KG) 8.9 13.6 19.1
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
PRINCIPAL FEATURES
EFFICIENCY AND FLEXIBILITY
• Output power factor equal to 1 for a better load capacity • Extremely flexible input adaptable to all needs, tolerance
at the same power with lower and more convenient range -60% ~ + 25%;
initial investment costs;
+25%
- 60%
• Innovative three-level IGBT technology integrated in the
inverter section;
Modalità ECO
display, for an improved and user-friendly user
experience;
• Battery configurations minimum 24 up to 40 per series
(± 144 ~ ± 240Vdc) via display;
• UPS input and output configurable from display in
single-phase and \ or three-phase (1: 1,3: 1,3: 3);
• Possibility of parallel installation (redundant or power)
up to 4 units;
• ECO, Normal or Parallel N + 1 mode configurable from
on-site display;
• Display available in 7 languages.
input-output-battery configuration directly from 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
display;
ECO Efficiency
AC/AC Efficiency
• Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
improve their efficiency.
STANDARD AND COMMUNICATIONS Cable terminal IN-OUT-BYP Parallel (only for PRL models)
RS485
TECHNICAL SPECIFICATIONS
NOISE (DB) < 55
TEMPERATURE (°C) -5~40
HUMIDITY 0 ~ 95%
UPS 438×500×130(3U)
DIMENSIONS (L×W×H) MM
Distribution Box 438×500×130(3U)
UPS 20
WEIGHT (KG)
Distribution Box 8
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
3:1 3:3
PRINCIPALS FEATURES
EFFICIENCY E FLEXIBILITY
• Output power factor equal to 1; • Advanced control with double redundant DSP;
100%
• ECO mode with efficiency up to 99%, configurable from
the display;
98%
+25%
ECO Efficiency
AC/AC Efficiency
- 60%
• Innovative three-level IGBT technology integrated in the
inverter section;
• 30kVA and 40kVA versions with configurable output • Shared batteries for parallel systems, a single battery
from display in single-phase or three-phase (3: 1,3: 3); pack for two N + 1 UPSs;
• Integrated external battery connector; • NC \ NO dry contact card for further 12 alarms
(optional).
UPS Trifase-monofase 37
TECHNICAL SPECIFICATIONS
IST7010010 IST7020005 IST7030005 IST7040005
MODELS
IST7010-L IST7020-L IST7030-L IST7040-L
INPUT
VOLTAGE (VAC) 80-280 (L-N) / 138-485 (L-L)
FREQUENCY (HZ) 40~70
VOLTAGE BYPASS (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3:3 / 3:1 / 1 : 1 3:3 / 3:1
OUTPUT
POWER (KVA) 10 20 30 40
POWER FACTOR 1
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD THD<1% (linear loads), THD <3% (non- linear loads)
WAVEFORM Sinusoidal pure, THD<1% linear
EFFICIENCY 97%
110% Overload for 60mins; 130% Overload for 10mins;
OVERLOAD
155% Overload for 1min; >155% Overload for 200ms;
BATTERIES
OTHER SPECIFICATIONS
COMMUNICATIONS RS485, MODBUS, Free contact card (RS232 e SNMP optional)
DISPLAY Touch screen+LED
NOISE (DB) <55
TEMPERATURE (°C) -5~40
HUMIDITY 0~95%
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
3:1 3:3
IST7 UPSs are available in two sizes, from 50kVA to 120kVA and from 160kVA to
200kVA. Thanks to the inverter’s 3 IGBT levels, the UPS guarantee efficiency up to
97% and a unitary output power factor. They are directly configurable from the display,
with ample flexibility in the number of batteries and high overload capacity. The
innovative self-cleaning function reduces the risk of dust accumulation on the boards.
The system includes the free contact card for alarms.
PRINCIPAL FEATURES
EFFICIENT AND EXPANDABLE
• Output power factor equal to 1; • Innovative three-level IGBT technology integrated in the
inverter section;
• Maximum AC \ AC efficiency up to 97%;
100%
• Expandable in power directly on site and from the
display;
98%
90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
ECO Efficiency
AC/AC Efficiency
MODULAR STRUCTURE
50kVA-120kVA Version
Pacco batteria in comune
Touch-Screen Display
• Battery Configurations:
Power modules up to 120kW
from 15 to 20 monoblocks (±180~±240Vcc);
DSP DSP
Touch-Screen Display
• Intelligent fans with high efficiency cooling, multiple
Bypass input and
output switches modes to control their speed, extend their life and
Control and Communication Module improve their efficiency.
Bypass Module
Power modules
up to 200kW Automatic fan control
SETTINGS FROM DISPLAY
• Access to the menu via different password levels (User,
Technician and Manufacturer);
EXCELLENT PERFORMANCE
• Efficiency higher than 95% even at low loads; • Advanced 3-stage battery charging and maintenance
system;
• Maximum output tolerance, ability to operate with 100%
unbalanced loads;
+25%
MINIMUM SIZE
• Extremely small size:
120kW only 450x840x1400mm for max 242Kg;
200kW only 600x900x1600mm for max 380Kg;
FREQUENCY CONVERTER
50HZ 60HZ
• 50Hz-60Hz or 60Hz-50Hz converter mode;
60HZ 50HZ
• Possibility of disabling the static bypass and the DC
Frequency Converter Mode
power supply of the inverter.
OPERATING MODES
Static Bypass Static Bypass
Batteries Batteries
Double Online Conversion ECO Mode
Static Bypass Static Bypass
Batteries Batteries
• Bypass switch for maintenance; • Protection against reverse polarity of the batteries;
• EPO emergency release button on the front, remote • SNMP network card for remote control and monitoring
clean contact on the back; (optional);
• Starting from battery by means of a specific button; • NC \ NO dry contact card for further 12 alarms
(optional).
ECONOMIC SAVING
Let’s take an example on a 120kVA AEC UPS working at full load H24 with average efficiency of 96% and a unit output power
factor, comparing it with a typical UPS with standard efficiency 93% and output power factor = 0.9:
• Daily savings:
(120kVA*1*96% - 120kVA*0.9*93%)*24 hours= 354.24 kWh;
APPEARANCE
IST7 50-120KVA
IST7 160-200KVA
TECHNICAL SPECIFICATIONS
INPUT
VOLTAGE (VAC) 380/400/415 (138~485 L-L)
FREQUENCY (HZ) 40~70
BYPASS VOLTAGE (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3+N+PE
OUTPUT
POWER (KVA) 50 80 100 120 160 200
POWER FACTOR 1
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD 3+N+PE
THREE-PHASE VOLTAGE
STABILIZATION AT FULL ≤2%
UNBALANCED LOAD
WAVEFORM Pure sine wave, THD<1% linear
EFFICIENCY 97%
105%~115% Overload for 60mins; 116%~130% Overload for 10mins;
OVERLOAD
131%~150% Overload for 1min; >150% Overload for 200ms
BATTERiES
BATTERIES VOLTAGE (VDC) ±192/±216 (±180/±204/±216/±228/±240 configurable)
External
MAX. CHARGING CURRENT (A) 1-30 1-40
OTHER SPECIFICATIONS
COMMUNICATIONS RS485, MODBUS, Free Contact Card (RS232 e SNMP opzionali)
DISPLAY Touch screen+LED
ALARMS Low batteries, Anormal input, Overload, Block/Fault ecc.
PROTECTION Low batteries, Overload, Short-circuit, Over-temperature ecc.
NOISE (DB) <65
TEMPERATURE (°C) 0~40
HUMIDITY 0~95%
DIMENSIONS (L×W×H) (MM) 450×840×1400 600×900×1600
WEIGHT (KG) 180 210 242 320 350
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
3:3
Their modularity allows future expansion in power up to 4.8MW. They are available in
four sizes, up to 120kVA | 200kVA - 300kVA | 600kVA- 800kVA | 1000kVA-1200kVA |
with an efficiency of up to 97% and maximum safety. IST6 is designed for medium and
large data centers. UPS configurable directly from the display, with great flexibility and
high overload capacity. The self-cleaning function reduces the risk of dust accumulation
on the cards. The system includes the free contact card for alarms.
UPS MODULAR
UPS Modular 45
PRINCIPAL FEATURES
MODULAR TECHNOLOGY HOT-SWAPPABLE
• Output power factor equal to 1;
98%
95%
93%
90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
On-ECO Efficiency
ECO Efficiency
AC/AC Efficiency
MAXIMUM SCALABILITY
• Innovative modular N + 1 technology in all components
of the UPS system;
• Expandable and hot potential directly on site and from • Battery configurations:
the display; from 15 to 20 monoblocks (± 180 ~ ± 240Vdc);
• Possibility of installation in a single structure up to • ECO mode with efficiency up to 99%, configurable from
1200kW with 12 modules of 100kW; the display;
• Possibility of parallel installation (redundant or power) • Advanced control with double redundant DSP;
up to 5MW;
DSP DSP
EXCELLENT PERFORMANCE
• Advanced 3-stage battery charging and maintenance
• Efficiency higher than 95% even at low loads;
system;
+25%
• Redundant and hot extractable power modules (rectifier
and inverter);
- 60%
OPERATING MODES
Static Bypass Static Bypass
Batteries Batteries
Online Double Conversion ECO Mode
Static Bypass Static Bypass
Batteries Batteries
• Bypass switch for maintenance; • Protection against reverse polarity of the batteries;
• EPO emergency release button on the front, remote • SNMP network card for remote control and monitoring
clean contact on the back; (optional);
• Starting from battery by means of a specific button; • NC \ NO dry contact card for further 12 alarms
(optional).
UPS Modular 49
TECHNICAL SPECIFICATIONS
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
TECHNICAL SPECIFICATIONS
CERTIFICAZIONI
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
51
Nowadays the use of data centers in the productive world is growing dramatically as they are of fundamental
importance to support the continuous technological development of our planet. If until a few decades ago the
interruption of the operation of a data center would not have caused great inconvenience, today we must always
remain vigilant and ready to intervene in the event of system failure.
For this reason, UPS uninterruptible power supplies are an indispensable element for the correct and continuous
operation of data centers and there are several factors to consider when evaluating the type of UPS to install.
CENTRAL POWER SUPPLY SYSTEM
CPSS EN50171
CENTRAL POWER SUPPLY SYSTEM
The EN 50171 standard provides for the obligation to install CPSS in crowded areas and in
public places such as hospitals, schools, museums, cinemas, etc. to provide lighting in the
event of a blackout.
Central Power Supply Systems (CPSS) and Uninterruptible Power Supply Systems
(UPS) have many similarities. As already explained, both products provide electricity
in the event of a blackout or network failure, but it is essential to know that
these two systems are used in different contexts and for this reason they are not
interchangeable.
Although CPSS and UPS have the same components, the former are designed
according to regulatory standards that guarantee maximum product safety to be
applied to safety systems and must comply with all the requirements of the EN
50171 standard.
In fact, the CPSS are used in the event of a power failure during an emergency and
danger situation, such as a fire or an earthquake and, especially on these occasions,
it is essential to have a lighting system that allows people to immediately identify
the ways of exodus, especially in public places subject to crowding and in the
workplace.
CPSS EN 50171
53
EN 50171 COMPLIANT
The EN 50171 standard applies to systems permanently connected to AC power supply voltages not exceeding 1000 V
and which use batteries as an alternative energy source. The structure of the CPSS electric rescuer must also comply with
the CEI EN 62040 standard. The EN 50171 standard lists the technical characteristics that the CPSS must possess in order
to be compliant.
FEATURES:
• Batteries:
The batteries used in the CPSS electric rescuers must have an expected life of at least 10-12 years;
• Overload:
The inverters used in the CPSS must be able to handle a constant overload of 120%;
• Charging Time:
The chargers used must recharge the batteries within 12 hours, starting from a low battery condition;
• Casing Resistence:
The casing of the CPSS must have excellent mechanical strength, capable of resisting heat and fire.
DETAILS:
• Constant overload of 120%;
• Batteries 10-12 years expected life;
• Charging time of less than 12 hours;
• Structure compliant with CEI EN 62040.
CPSS SOCCORRITORI
CPSS EN-50171 55
TECHNICAL SPECIFICATIONS
LCD DISPLAY Input / output voltage and frequency, protected load level, battery charge status, temperature, UPS operation and lockout / fault
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
DETAILS:
• Constant overload of 120%;
• Batteries 10-12 years expected life;
• Charging time of less than 12 hours;
• Structure compliant with CEI EN 62040.
CPSS EN 50171
CPSS EN-50171 57
TECHNICAL SPECIFICATIONS
CPSS7010 CPSS7020 CPSS7030 CPSS7040
MODELS
CPSS7010-L CPSS7020-L CPSS7030-L CPSS7040-L
INPUT
VOLTAGE (VAC) 80-280 (L-N) / 138-485 (L-L)
FREQUENCY (HZ) 40~70
BYPASS VOLTAGE (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3:3 / 3:1 / 1 : 1
OUTPUT
POWER (KVA) 10 20 30 40
POWER FACTOR 0.8
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD THD<1% (linear loads), THD <3% (non-linear loads)
WAVEFORM Sinusoidal pure, THD<1% linear
EFFICIENCY 96%
OVERLOAD Constant up to 120%
BATTERIES
BATTERIES VOLTAGE (VDC) ±192 (±96~±240 configurable) / ±192 (±144~±240 configurable)
MAX. CHARGING CURRENT (A) 1-10 / 1-20 (configurable)
BATTERY LIFE 10 - 12 years
OTHER SPECIFICATIONS
CHARGING TIME < 12 hours
COMPLIANCE Structure in compliance with CEI EN 62040
NOISE (DB) < 65
TEMPERATURE (°C) 0 ~ 40
HUMIDITY 0~95%
DIMENSIONS (L×W×H) (MM) 250×755x880 300x785x1250
WEIGHT (KG) 143 240
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
DETAILS:
• Constant overload of 120%;
• Batteries 10-12 years expected life;
• Charging time of less than 12 hours;
• Structure compliant with CEI EN 62040.
CPSS EN 50171
CPSS EN-50171 59
TECHNICAL SPECIFICATIONS
INPUT
VOLTAGE (VAC) 380/400/415 (138~485 L-L)
FREQUENCY (HZ) 40~70
BYPASS VOLTAGE (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3-4W+PE
OUTPUT
POWER (KVA) 50 80 100 120 160 200
POWER FACTOR 0.8
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD 3-4W+PE
WAVEFORM Pure Sinusoidal , THD<1% linear
EFFICIENCY 96%
OVERLOAD Constant a 120%
BATTERIES
BATTERIES VOLTAGE (VDC) ±192/±216 (±180/±204/±216/±228/±240 configurable)
STANDARD BATTERY
External
CONFIGURATION
MAX. CHARGING CURRENT (A) 1-30 1-40
BATTERY LIFE 10 - 12 years
OTHER SPECIFICATIONS
CHARGING TIME < 12 hours
COMPLIANCE Structure in compliance with CEI EN 62040
NOISE (DB) <65
TEMPERATURE (°C) 0~40
HUMIDITY 0~95%
DIMENSIONS (L×W×H) (MM) 450×840×1400 600×900×1600
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
Through the SNMP card, AEC is also able to carry out H24
checks on each UPS, as part of ordinary and / or preventive
maintenance contracts.
The relay or dry contact card provides a series of potential-free normally open or normally closed contacts to signal the
following UPS functions:
USB CARD
The USB card allows you to connect the UPS to all latest generation
computers via a USB port on the PC. This card is essential if the UPS
does not have the RS232 port and is compatible with all our UPS
models.
61
AEC is able to offer its customers a tested and solid cabinet housing system for accumulators designed to
ensure continuity of power supply for UPS of any size.
BB2+
BB3+
BBJ
BBJ+
BB5 Battery cabinet for three phase and single phase UPS :
Possible configurations:
Max 120 x 12V 9Ah
Max 38 x 12V 26Ah
Max 38 x 12V 40Ah
Max 16 x 12V 60-80-100Ah
BB6 Battery cabinet for three phase and single phase UPS :
Possible configurations:
Max 48 x 12V 26Ah
Max 40 x 12V 40Ah
Max 36 x 12V 60Ah
Max 24 x 12V 80Ah
Max 24 x 12V 100Ah
BB7 Battery cabinet for three phase and single phase UPS:
Possible configurations:
Max 64 x 12V 26Ah
Max 60 x 12V 40Ah
Max 48 x 12V 60Ah
Max 36 x 12V 80Ah
Max 36 x 12V 100Ah
BB8 Battery cabinet for three phase and single phase UPS:
IP20 steel metal battery cabinet
Dimensions 1400x800x1900mm
Empty weight 365Kg
Possible configurations:
Max 120 x 12V 26Ah
Max 100 x 12V 40Ah
Max 80 x 12V 60Ah
Max 64 x 12V 80Ah
Max 64 x 12V 100Ah
OZ Power lead-acid AGM batteries can last up to 10-15 years, but can
affect several external factors on battery life such as:
- Incorrect use of the battery;
- Inadequate maintenance carried out by a non-specialized technician;
- Exposure to extreme temperatures, both too high and too low;
- Incorrect recharging of the battery using an unsuitable charger.
OZ Power AGM batteries are always sold fully charged and, once
discharged, it is advisable to fully recharge them to make the most of
their potential and to avoid deteriorating them, thus reducing their
capacity and therefore also their duration. Furthermore, it is strongly
recommended to carry out a full recharge to 100% even in case of
prolonged non-use of the battery and to be checked by a specialized
technician for complete efficiency.
67
BATTERY MODELS
12V OZ POWER:
MAIN CHARACTERISTICS
12V 9Ah
• Totally hermetic without emission of gas in use;
• No liquid to add during the entire life of the batteries;
• No risk of acid loss as the electrolyte (diluted sulfuric acid) is
absorbed in an AGM opaque glass-like support;
• The plates are very robust and are welded with special alloys to
12V 26Ah ensure high mechanical resistance;
• The casing is made of ABS (Acrylonitrile Butadiene Styrene);
• The batteries comply with the international standards JIS, UL, VDE,
IATA;
• The batteries are designed for high fast discharge currents;
• The expected life of AEC batteries is 10-12 years, according to the
12V 40Ah EUROBAT guide;
• Enclosures are constructed to UL-94 HB or UL94-V0 fire resistant.
12V 80Ah
12V 100Ah
WWW.OZPOWER.IT
OZ POWER | 12V 9AH
AGM SEALED LEAD BATTERY
TECHNICAL SPECIFICATIONS
CELL PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 9Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 2.50Kg(5.51Lbs)
INTERNAL RESISTANCE <18mΩ
TERMINAL TYPE F2
MAX DISCHARGE CURRENT 130A
DESIGN LIFE 8-10 Years
MAX CHARGE CURRENT 2.7A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15.0V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 151±1 mm
AMBIENT TEMPERATURE
Charge: 0°C~40°C WIDTH 65±1 mm
Storage:-15°C~40°C
HEIGHT 94±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 100±1 mm
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
WWW.OZPOWER.IT
OZ POWER | 12V 26AH
AGM SEALED LEAD BATTERY
TECHNICAL SPECIFICATIONS
CELL PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 26Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 8.0Kg
INTERNAL RESISTANCE <12mΩ
TERMINAL TYPE IT (F12)
MAX DISCHARGE CURRENT 375A (5s)
DESIGN LIFE 8-10 Years
MAX CHARGE CURRENT 7.8A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 166±2 mm
AMBIENT TEMPERATURE Charge: 0°C~40°C WIDTH 175±2 mm
Storage:-15°C~40°C
HEIGHT 125±2 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 125±2 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
WWW.OZPOWER.IT
OZ POWER | 12V 40AH
AGM SEALED LEAD BATTERY
TECHNICAL SPECIFICATIONS
CELL PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 40Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 12.60Kg
INTERNAL RESISTANCE <10mΩ
TERMINAL TYPE IT (M)
MAX DISCHARGE CURRENT 380A (5s)
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 12A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 197±3 mm
AMBIENT TEMPERATURE Charge: 0°C~40°C WIDTH 165±1 mm
Storage:-15°C~40°C
HEIGHT 170±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 170±1 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
WWW.OZPOWER.IT
OZ POWER | 12V 60AH
AGM SEALED LEAD BATTERY
TECHNICAL SPECIFICATIONS
CELL PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 60Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 16.50Kg
INTERNAL RESISTANCE 8mΩ
TERMINAL TYPE IT (M6)
MAX DISCHARGE CURRENT 500A
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 15A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 229±1 mm
AMBIENT TEMPERATURE Charge: 0°C~40°C WIDTH 138±1 mm
Storage:-15°C~40°C
HEIGHT 205±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 210±1 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
WWW.OZPOWER.IT
OZ POWER | 12V 80AH
AGM SEALED LEAD BATTERY
TECHNICAL SPECIFICATIONS
CELL PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 80Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 22.50Kg
INTERNAL RESISTANCE 6.6mΩ
TERMINAL TYPE IT (M6)
MAX DISCHARGE CURRENT 700A
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 22.5A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 259±3 mm
AMBIENT TEMPERATURE
Charge: 0°C~40°C WIDTH 168±1 mm
Storage:-15°C~40°C
HEIGHT 208±3 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 214±3 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
WWW.OZPOWER.IT
OZ POWER | 12V 100AH
AGM SEALED LEAD BATTERY
TECHNICAL SPECIFICATIONS
CELL PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 100Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 30Kg
INTERNAL RESISTANCE 5mΩ
TERMINAL TYPE IT (M8)
MAX DISCHARGE CURRENT 1000A
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 33A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 330±3 mm
AMBIENT TEMPERATURE
Charge: 0°C~40°C WIDTH 173±2 mm
Storage:-15°C~40°C
HEIGHT 215±3 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 220±3 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
WWW.OZPOWER.IT
We have been guaranteeing continuity
and reliability since 1968
WE ARE BEHIND THE POWER...
AEC GROUP
Offices in the world
CONTACTS
Main office Head office address
+39 02 94158991 Via Nerviano 55, 20045
Mobile\WhatsApp Lainate, MI
+39 3349785900 Italia