Occupancy Category
Seismic conditions for HRSG (in addition to above or where conflict exists HRSG specific value prevales) MPW060522: Not Applicable To ECA Compressor.
HHITMC140622: Confirm (HHITMC062922:
Effective Shear Wave Propagation Rate, Vs(m/s) 372.09
Delete)
HHITMC140622: Confirm (HHITMC062922:
Period of Dominance at the Site, Ts( sec) 0.43
Delete)
HHITMC140622: Confirm (HHITMC062922:
Response Factor, Fr= 3.571
Delete)
HHITMC140622: Confirm (HHITMC062922:
Site Factor, Fs= 1.75
Delete)
3.3. GENERAL TECHNICAL REQUIREMENTS REQUIREMENTS FINAL AGREEMENT
Area Classification
Noise:
Utility Supply
Cooling Water Requirements MPW060522: Confirm Compliance.
Type Treated Demineralized Water HHITMC140622: Confirm
Max Supply Temperature for Heat Exchanger Sizing [°F (°C)][122 (50)] HHITMC140622: Confirm
Mechanical Design Temperature [°F (°C)] [165.2 (74)] HHITMC140622: Confirm
Minimum Supply Temperature [°F (°C)] [50 (10)] HHITMC140622: Confirm
Mechanical Design Pressure [psig (MPag)] [150 (1.03)] HHITMC140622: Confirm
Instrument Air Requirements MPW060522: Confirm Compliance.
Mechanical Design Temperature [°F (°C)] [140 (60)] HHITMC140622: Confirm
Mechanical Design Pressure [psig (MPag)] 145 [1] HHITMC140622: Confirm
Maximum Operating Pressure [psig (MPag)] HOLD
Normal Operating Pressure [psig (MPag)] 100 [0.69] HHITMC140622: Confirm
Normal Operating Temperature [°F (°C)] More than 41 degF HHITMC140622: Confirm
80air
Minimum Supply Pressure to be used for sizing (i.e. instrument [0.55]
actuators) HHITMC140622: Confirm
Minimum Supply Pressure [psig (MPag)] 80 [0.55] HHITMC140622: Confirm
Instrument Air Dew Point [°F (°C)] [-40 (-40)] HHITMC140622: Confirm