Download as pdf
Download as pdf
You are on page 1of 6
(if installed) ‘There are two diferent JCB immobiliser systems, one uses a keypad and the other a unique key system. 1f your machine has an immobiliser system installed, then your JCB dealer should enable the system as part of the standard machine Installation. If you prefer that the system is not enabled, then you must tell your JCB dealer, Your JCB ealer can enable the system at later date. Machines with Immobilisers installed should always be parked as per the instructions in the operators manual Introduction Before attempting to disarm the immobiliser check that the machine is ready to start and that you have your four digit, PIN (Product Identification Number) code available. The green LED (Light Emitting Diode) will illuminate every time that 2 keypad button is fully depressed. Do not operate buttons with sharp objects, they may damage and disable the keypad If you make an error entering your PIN code and you realise this before pressing the ENT button then pressing the MD button cancels inputs and allows you to re-commence. Ifthe PIN code Is incorrectly entered five times the immobiliser will lock for 15 min. In this event itis recommended that you contact the machine owner for confirmation of the PIN code, The PIN code will have to be entered every time that the ignition is switched off for longer than two minutes. To Disarm the Immobi 1 er to Allow the Machine to be Used Put the ignition key in the ignition switch. Turn the ignition key to position 1, Enter your four digit PIN code using the keypad. Push the ‘ENT’ button. The LED will come on for three seconds if the PIN code is correct and the machine can be started If an incorrect PIN code is entered the unit will lock. The LED will flash twice quickly, pause and then flash twice again and will continue this pattern until the ignition key is turned to the off position. Tn this event return to step 1 to try again. 4.1, After five faled tries the system will lock. Duration: 15 min 2aeed oaan| DOoe DONE Le To Arm the Immobiliser 1. Stop the engine. Remove the ignition key. 2, The immobiliser arms automatically after two minutes ‘The green LED flashes for 60 seconds, then goes off. 3. Ifyou restart the engine within two minutes, the system disarms automatically To Add a New or Additional PIN Code Before you try to add a new or additional PIN code, make sure that the machine is ready to start and that you have your six digit master code and your new four digit PIN code available. If you are unsure of the master code or your new PIN code, then do not start this procedure. The keypad immobiliser can be programmed to accept up to 14 different four digit PIN codes, any of which will lt the machine be started. 41, Put the ignition key in the fgnitfon switch, Turn the Ignition key to position 1 2, Enter your six digit master code using the keypad. Push the ‘ENT button. 3, The LED will flash three times to indicate the acceptance of the master code, 4, Within 59 seconds of the three flashes, push the "MD" button 5, Enter your new four digit PIN code using the keypad, Push the ‘ENT button. The LED will flash four times to indicate that the new PIN code has been successfully entered. 6. Turn the Ignition key to the off position, then a minimum of five seconds later, turn the ignition key to position 1. The new PIN code is now entered end Fecorded 7. If another PIN code is to be entered, turn the ignition key to the off position, then return to step 1. To Delete all of the PIN Codes Deleting all the PIN codes does not allow the immobiliser to be bypassed. A four digit PIN code must be entered before 1e machine can be started. If you are unsure of the master PIN code or your new PIN code, then do nat start this procedure. 4, Put the ignition key in the fgnitfon switch, Turn the ignition key to position 1. 2. Enter your six digit master PIN code using the keypad. Push the ‘ENT button. The LED will flash three times to indicate the acceptance of the code. 3, Push the buttons in the following sequence, 'MD', 'F1', "ENT". The LED will flash five times to indicate the acceptance of the delete command, Unique Key Immobiliser System The red key must not be kept on the same key ring as the black key, If the red key is too close to the key switch the antenna can pick up on the key transponder and cause the immobiliser ECU (Electronic Control Unit) ta enter the key programme mode. if this happens it will prevent the machine from starting and the antenna LED will blink 3 times indicating the immobiliser ECy is in the key programme mode, Introduction Each machine is supplied with a master key (red) and two ignition keys (black). The master key is used by the operator to program the ignition keys. You must use an ignition key to start or operate the machine. i To Disarm the Immobiliser Figure 2. 1. Put the ignition key in the ignition switeh. 2, Start the engine, Figure 3 a Col/ a [LED (The position may vary) To Arm the Immobiliser 1. Stop the engine. Remove the ignition key. 2, The immobiliser immediately arms automatically To Add a New or Adi jonal Ignition Key The ignition keys can be programmed to start more than one machine. 4, Put the master key in the ignition switch, 2, Turn the master key to position 1. The LED will fash three times, 3, Turn the master key to position 0, Remove the master key. 4. Puta new or an additional ignition key in the ignition switch, Turn the ignition key to position 1, The LED will flash four times. 5. The new key has been added ‘To Remove the Program From an Ignition Keys The ignition keys can still be used on any other machine on which they have been programmed. 41, Put the master key in the ignition switch, 2. Turn the master key to position 1. The LED will flash three times. 3, Keep the master key in position 1 for 60 seconds, The ignition keys codes have now been deleted from the ECU. 4, Turn the master key to position 0, Remove the master key. 5, Add the required black keys in the system, The starter keys will still be able to be used on any other machine on which they have been programmed, If a non-programmed key or standard key is used, then a symbol will appear on the LCD (Liquid Crystal Display) screen, ‘and the machine will not start

You might also like