SKYCOM CAN-X
Installation Manual
FM 40432
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 2
REF: ILE-TS-CXIM-V1.0 27/02/2013
Contents
Introduction .................................................................................................................................................... 4
System outline ................................................................................................................................................. 4
System limitations ........................................................................................................................................... 4
System nomenclature ...................................................................................................................................... 4
Quick start kit .................................................................................................................................................. 6
General do’s and don’ts ........................................................................................................................................................................ 6
Fitting the quick start kit ....................................................................................................................................................................... 7
Preparing the control panel run on inspection ..................................................................................................................................... 9
Mains connections ........................................................................................................................................................................... 9
Braking resistor fitting and connections (traction only) ................................................................................................................... 9
Motor connections (traction) ......................................................................................................................................................... 11
Motor connections (Hydraulic) ...................................................................................................................................................... 12
Motor encoder connections (traction) ........................................................................................................................................... 13
Machine connections (traction) ..................................................................................................................................................... 14
Valve connections (hydraulic) ........................................................................................................................................................ 15
Starting up both hydraulic and traction ......................................................................................................................................... 16
Drive start up wizard (traction) ...................................................................................................................................................... 18
Ready to run? ................................................................................................................................................................................. 18
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 3
REF: ILE-TS-CXIM-V1.0 27/02/2013
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 4
REF: ILE-TS-CXIM-V1.0 27/02/2013
Introduction
The Skycom CAN-X control system has been designed to speed up installation time by being supplied as
standard with looms that include all shaft wiring, motor room wiring, trailing flex and car wiring. This system
not only speeds up installation time thus reducing the down time for the customer it also cuts down on
wiring errors as all looms are tested before leaving ILE’s factory.
This manual outlines the correct procedure for connecting and installing these looms. For setting the drive
up (traction lifts) see the Can-X Fuji drive manual.
System outline
The Skycom CAN-X control system is a distributed system. All I/O devices are local to their input or output, so
the landing pushes have an I/O board mounted locally to them and the data from them is sent to the CAN-X
CPU via a CAN cable (included in the loom). The same localisation of I/O is carried through to the car. The car
top I/O and connections are housed within a custom halfway box and the I/O for the COP is pre-wired and
fitted to a din rail to be mounted in the back of the COP. If the COP or landing push stations are bought from
ILE these will be pre-wired and pre-addressed and will plug directly into the loom.
System limitations
Standard shaft and trailing flex looms have been tested for 32 floors up to 125M length (with ILE
indicators at each floor). Installations above these lengths may require special looms, available on
request.
For ease of installation we recommend the use of 75mm x 75mm trunking.
Non ILE indicators are not catered for within the loom. If foreign indicators are to be fitted they have
to be hard wired in accordance with their manufacturer’s instructions.
Alarm bell wiring is not included within the loom as it is not an EN81 requirement. We give the
installer connections at the car top I/O unit and in the control panel for connecting an alarm bell if
required.
Connections for auto diallers or pit / car intercoms are not included in the loom (although the spare
cores in the trailing flex could be used).
Fixings are not included within the loom pack, neither are the trailing flex hangers. (these can be
supplied seperatley)
System nomenclature
The drawings for the Skycom CAN-X control system are marked into 2 categories “E” for Electrical and “R”
for Reference. E.g. C8259E7, C8259R2. Electrical drawings are the as wired drawings. Some of these
drawings include external equipment for clarity but are generally how the control circuit is wired. It is these
Electrical drawings that should be used for any fault finding. The drawing overleaf shows how to identify the
different types of drawing.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 5
REF: ILE-TS-CXIM-V1.0 27/02/2013
The reference drawings are split into categories (car top, motor room e.t.c.) and should be used for
connecting the looms to the auxiliary equipment and the controller / car top I/O. All of these reference
drawings refer to connections on the main Electrical drawings.
The control panel’s terminals are sectioned into zones all proceeding with an “X”. On the drawings these are
followed by the terminals nomenclature e.g. X19:L3. The car top’s terminals are sectioned into zones
proceeding with a “Y”. 2 extra zones are allowed for we call these “XOP” and “YOP”. These are for optional
equipment on the controller (XOP) and the car top (YOP).
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 6
REF: ILE-TS-CXIM-V1.0 27/02/2013
NOTE; The condition of all jumper plugs and cables and the test unit cable should be checked prior to
every installation and should be used in a controlled manner in line with your companies health and
safety policy.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 7
REF: ILE-TS-CXIM-V1.0 27/02/2013
+
O C P P P
T 2
S T T T T
R 4
G E R U D
V
X5
PLUG IN TO X5 ON
THE TERMINAL RAIL
+
O C PS P P
S T 2
S
P T TP T T
G E R
R
U D
4
V
REEL OFF TO THE
DESIRED LENGTH
THEN LOCK IT OFF
X5
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 8
REF: ILE-TS-CXIM-V1.0 27/02/2013
PLUG IN TO X4 ON
THE TERMINAL RAIL
0 S M
D
S C
P V P E
Z F
R S
X4
NOTE:THIS IS THE
STANDARD ILE
HANDWINDING UNIT.
DIFFERENT UNITS
ARE AVAILABLE BUT
ALL PLUG INTO X4
o Fit jumper plugs into X8, 10, 11, 12 and 13 on the controller terminal rail as diagram below.
C T T
C C S C C T C L D D P O S B O C L S S S T U U M P O O
T U U D D U
L L G T T U D D G G E S S G S T D D M M M U M M E E S S T
S L L L L L
S N S E S L C C S N P G S S L C C U C D L 1 2 S P G L
1 1 1
PLUG THE
APPROPRIATE PLUG
X8 X10 X11 X12 X13 X14 INTO THE
CORRESPONDING
SOCKET ENSURING
THAT THE SOCKET
PINS DO NOT GET
BENT
C T C L T U U
C C SS C C T C L D D P O S B O U S SS S D T M PS O O
S T U S S
D D D U M M
S
LP L GP T T U D D G G E
P S SP G S T L M M M L
P U E
P E SP S T
S L C C L L 1 2
S N S E S L C C S N P G S S L U C D L S P G L
1 1 1
X X X X X
X 1 1 1 1 1
8 0 1 2 3 0
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 9
REF: ILE-TS-CXIM-V1.0 27/02/2013
Mains connections
The incoming mains are connected at the control panel terminal rail on both traction and hydraulic lifts at
location X17. Traction lifts are supplied with a screened SY cable and Hydraulic lifts with single cables. The
cable is cut to the length that was specified at the time of survey, if it is too long it can be cut to the desired
length.
TO OPEN CAGE
CLAMP
TERMINAL
INSERT A
SCREWDRIVER
INTO THIS SLOT
UNTIL IT CLICKS PRESS
IN
L L L
N E
1 2 3
INSERT A
SCREWDRIVER INTO
THE SLOT IN THE
EMC CLAMP AND
APPLY PRESSURE
12mm X17 TO COMPRESS THE
SPRING
1 2 3 4
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 10
REF: ILE-TS-CXIM-V1.0 27/02/2013
heat can dissipate efficiently and that now other components around the resistor can be damaged by the
heat. See diagram overleaf showing correct mounting and connections.
TO OPEN
CAGE CLAMP
TERMINAL
INSERT A
SCREWDRIVE
R INTO THIS PRESS
SLOT UNTIL IT
CLICKS IN
P D
E
+ B
INSERT A
SCREWDRIVER INTO
THE SLOT IN THE
EMC CLAMP AND
APPLY PRESSURE
12mm X18 TO COMPRESS THE
SPRING
1 2
INSERT CABLE
INTO THE OPEN
EMC CLAMP AND
RELEASE THE
SCREWDRIVER
SO THE SPRING
NOW CLAMPS
THE CABLE
<0.5m
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 11
REF: ILE-TS-CXIM-V1.0 27/02/2013
PRESS
E MC
INSERT A
2 T1 4 T2 6 T3
SCREWDRIVER INTO
THE SLOT IN THE
EMC CLAMP AND
APPLY PRESSURE
X17 TO COMPRESS THE
SPRING
12mm
1 2 3
1 2 3
U1 V1 W1
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 12
REF: ILE-TS-CXIM-V1.0 27/02/2013
TO OPEN CAGE
CLAMP
TERMINAL
INSERT A
SCREWDRIVER
INTO THIS SLOT CABLES MUST BE PROTECTED BY SUITABLE
UNTIL IT CLICKS MECHANICAL PROTECTION (NOT SUPPLIED)
IN
U V W U V W
E
1 1 1 2 2 2
12mm X18
U1 V1 W1
U2 V2 W2
`
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 13
REF: ILE-TS-CXIM-V1.0 27/02/2013
1 2
4
GEARLESS / TTL ENCODER
CONNECTIONS
GEARED ENCODER
CONNECTIONS
20mm
CUT BACK SHEATH TO
ROUTE ENCODER CABLE EXPOSE THE SCREEN CLAMP THE EXPOSED
THROUGH RUBBER GROMET SCREEN TO THE CHASSIS OF
AND CONNECT TO THE THE DRIVE USING THE EMC
CORRECT SOCKET CLAMP PROVIDED
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 14
REF: ILE-TS-CXIM-V1.0 27/02/2013
LOOM
B B B B T T
B B +
PL1337
P F K K 2
K K K K H H
N S S S 4
+ + - - 1 2
1 2 V
B B +
B B B B T T
P
S F SP K K 2
P K K K K H H
N S S S 4
+ + - - 1 2
1 2 V
PLUG IN TO X15 ON
THE TERMINAL RAIL
X15
X15
X15
X15
MOTOR FAN
(230VAC)
The diagram above is for guidance only and is shown wired in compliance with EN81-1 with A3.The cables
are connected as follows and should be connected in conjunction with the R1 drawing.
5 core cable marked MOTOR THERMISTORS & BRAKE SWITCHES should be wired as follows;
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 15
REF: ILE-TS-CXIM-V1.0 27/02/2013
The valve cable is not detailed below because each valve type has an individual loom manufactured for it.
Please refer to the R1 drawing for further details.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 16
REF: ILE-TS-CXIM-V1.0 27/02/2013
1 PHASE+
THERMISTOR
PFRR
2 U NOT LIT UP
RELAY
CHECK VOLTAGE BETWEEN AT
CHECK FOR ALL 3 LED’S ON CONTROLLER TERMINAL RAIL
U
THE PFRR. X17
TC L1-L2
U=POWER SUPPLY PRESENT
(GREEN LED) L2-L3 ALL 400V or ABOVE L L L
R E
L1-L3 1 2 3
TC=THERMISTORS OK (RED
LED) L1-E
L2-E ALL 230V or ABOVE
R=PHASES PRESENT AND L3-E
1 2 3
ROTATION OK (RED LED)
IF ALL VOLTAGES ARE OK
X17
IF ALL LED’S LIT UP GOTO THE CHECK CB1 CIRCUIT BREAKER
NEXT SECTION IS IN THE START POSITION IF IT
IS OK CONTACT ILE
TECHNICAL SUPPORT
3
B B +
4
B B B B T T
TC NOT LIT UP P F
N S
K K K K H H
K K
S S
2
4 R NOT LIT UP
+ + - - 1 2
1 2 V
X15
X15
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 17
REF: ILE-TS-CXIM-V1.0 27/02/2013
5 E C L U L
6
M D D M T
R R R R R
CHECK FOR ALL 5 LED’S ON IF NO LEDS ARE LIT UP CHECK
THE SSR’S (3rd RAIL DOWN ON THE SUPPLY VOLTAGE AT F1
110VAC
THE CONTROL PANEL) (110VAC)
IF NO VOLTAGE IS PRESENT
PROCEED TO STEP 9
7
CONNECT YOUR METER
8
BETWEEN THE BOTTOM TEST
POINT AND EARTH CONNECT YOUR METER
BETWEEN NUMBER 2 ON THE
IF VOLTAGE IS PRESENT BOTTOM R/H CORNER OF THE
PROCEED TO STEP 8 CPU AND EARTH
110VAC
9
CHECK THE FOLLOWING ITEMS;
IF THE ANSWERS TO ALL THE ABOVE ARE YES, PLEASE CONTACT ILE TECHNICAL SUPPORT FOR ADVICE.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 18
REF: ILE-TS-CXIM-V1.0 27/02/2013
If we supplied the motor the wizard data may have already been entered and the motor tune completed.
Check the front panel of the drive, there will be a label stating whether the set up wizard has been
completed or not. See below.
Ready to run?
If all the steps in this section have been completed correctly the lift should now be running on the quick start
kit pendent.
NOTE: The lift is running with no safety circuits connected (except the pendent stop) so all the following
operations should be carried out in a controlled manner to your company’s health and safety policy. If in
doubt consult your H&S department.
If the lift is not running after this stage or you are unsure about any of the stages so far please contact ILE
technical support.
The loom is pre-marked with a hanger position which the loom is referenced from. This position corresponds
to 2.5m above the top floor finished floor level.
Please ensure all looms are wired at the destination end BEFORE connecting to the controller terminal rail.
NOTE: It is imperative the loom is hung from this level. If it is not hung from this level the loom tap off
points could be in the wrong position and the loom could be too long or too short.
NOTE: it is recommended that the loom is dropped before any of the peripheral looms are fitted and cut
(if necessary) to length.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 19
REF: ILE-TS-CXIM-V1.0 27/02/2013
KG
CABLES SHOULD BE
!! !! !! !!
PLUGS SHOULD NOT BE
TIED BACK TO THE EMC
LEFT SO THE WEIGHT OF
RAIL SO NO UNDUE
THE CABLE CAN CAUSE
PRESSURE CAN BE
UNDUE PRESSURE ON
EXERTED ON THE
THE CONNECTION
PLUGS
The hanger
The hanger is a fabricated galvanised steel bracket custom made for the Can-X application. The last 75mm of
the hanger has a rubberised coating to stop the loom cores chaffing when fitted. Additional hangers should
be fitted at intermediate floors when the hang exceeds 30m.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 20
REF: ILE-TS-CXIM-V1.0 27/02/2013
Hanger installation
The loom should be fixed to the hanger as detailed in the following diagram.
1
INTERNATIONAL LIFT EQUIPMENT INTERNATIONAL
INTERNATIONALLIFT
LIFTEQUIPMENT
EQUIPMENT
LOCATE THE FIX THIS HANGER FIX
FIXTHIS
THISHANGER
HANGER
HANGER 2500mm ABOVE TOP 2500mm
2500mmABOVE
ABOVETOP
TOP
FLOOR FINISHED FLOOR FLOOR
FLOORFINISHED
FINISHEDFLOOR
FLOOR
LEVEL LEVEL
LEVEL
2 3
LOCATE THE LABEL THREAD THE LOOM
ON THE LOOM. THIS THROUGH THE
IS THE REFERNECE HANGER,
POINT FOR THE THREADING AN
LOOM AND SHOULD EQUAL AMMOUN OF
BE ATTACHED CABLES OF THE
2500mm ABOVE THE LEFT AND RIGHT
TOP FLOOR LEVEL HAND FORKS THEN
FIX WITH MULTIPLE
CABLE TIES
The loom and hanger should then be fitted into the trunking using fixings appropriate for the weight of the
loom (not supplied) at a distance of 2.5m from the top floor finished floor level as detailed in the following
diagram.
USE FIXINGS
APPROPRIATE FOR
THE WEIGHT OF THE
LOOM
2.5m
FFL
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 21
REF: ILE-TS-CXIM-V1.0 27/02/2013
NOTE: This is particularly important for the CAN data cables as excess coiling of cables can cause
communication problems.
LOCK
LOCK
LOCK
LOCK LOCK LOCK PL1328
PL1328
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 22
REF: ILE-TS-CXIM-V1.0 27/02/2013
1
LOCATE THE TLL1 AND TLL2
SOCKETS WITHIN THE LOOM (250mm
BELOW THE HANGER) RUN THE TOP 2 FINAL LIMIT
LIMIT ARRAY LOOM TO THE LIMITS
AND WIRE THE CORES IN AS
SHOWN TO THE LEFT. REFER TO
THE R2 DRAWING. CONNECT PLUGS 7
TLL1 AND TLL2 INTO THIER
CORRESPONDING SOCKETS.
STOP LIMIT
TLL1
TLL1
5
LINK NOT SUPPLIED
SPEED MONITOR
6 LIMIT (TRACTION ONLY)
TLL2
TLL2
TEST LIMIT
4
NOTE: The ILE limit arrays limits are marked as LS1, 2, 3, and 4. We do NOT mark the corresponding limit
number on the drawing (only it’s function) as the array can be fitted either way round depending on the
installation. (So LS1 would become LS4 and vice versa)
Lock connections
The lock connection looms are supplied as single multi core cables per floor fitted with a plug to connect to
the main loom. The plugs are marked LOCK the loom has a part number of PL1328. Details of how to
connect this loom to the locks are on the R2 drawing and are also detailed in the drawing below.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 23
REF: ILE-TS-CXIM-V1.0 27/02/2013
1
LOCATE THE LOCK SOCKET(S)
WITHIN THE LOOM (2000mm ABOVE
2 LOCK CONTACT
FLOOR LEVEL) RUN LOCK LOOM(S)
TO THE LOCK(S) AND WIRE THE
CORES IN AS SHOWN TO THE LEFT.
REFER TO THE R2 DRAWING.
CONNECT PLUG(S) LOCK INTO ITS
CORRESPONDING SOCKET.
STOP LIMIT
LOCK
LOCK
PL1328
LOCK
1
LOCATE THE LOCKED SOCKET(S)
WITHIN THE LOOM (2000mm ABOVE
FLOOR LEVEL) RUN LOCK LOOM(S) 2 PRE LOCK CONTACT
TO THE PRE LOCK(S) AND WIRE THE
CORES IN AS SHOWN TO THE LEFT.
REFER TO THE R2 DRAWING.
CONNECT PLUG(S) LOCK INTO ITS
CORESPONDING SOCKET.
STOP LIMIT
LOCKED
LOCKED
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 24
REF: ILE-TS-CXIM-V1.0 27/02/2013
5
LOCATE THE BLL SOCKETS WITHIN
THE LOOM (AT BOTTOM FLOOR
4 FINAL LIMIT
LEVEL) RUN THE BOTTOM LIMIT
ARRAY LOOM TO THE LIMITS AND
WIRE THE CORES IN AS SHOWN TO
THE LEFT. REFER TO THE R2 3
DRAWING. CONNECT PLUG BLL INTO
ITS CORRESPONDING SOCKET.
STOP LIMIT
2
LINK NOT SUPPLIED
SPEED MONITOR
1 LIMIT (TRACTION ONLY)
BLL
BLL
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 25
REF: ILE-TS-CXIM-V1.0 27/02/2013
OVER SPEED
1 GOVERNOR
FINAL LIMIT TENSION
JUST A LINK ON PL1334 (NO WEIGHT
BUFFERS)
OSG TENSION
FRAME
OSGL
1
OSGL
BUFFER SWITCH
CAR
CAR BUFFER
2 SWITCH
COUNTERWEIGHT
BUFFER SWITCH
TRUNKING
1
TEST LIMIT
COUNTERWEIGHT
2 BUFFER SWITCH
1
1
PIT STOP
2 SWITCH 1
1
2
PIT STOP
2
SWITCH 2
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 26
REF: ILE-TS-CXIM-V1.0 27/02/2013
DC+
DC+
DC-
DC-
LOOM PL1329
IO1
IO2
CH
CL
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 27
REF: ILE-TS-CXIM-V1.0 27/02/2013
2
1
DC+
DC+
IND DC-
DC-
PL1329
ILE POSITION
INDICATOR
CH
CL
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 28
REF: ILE-TS-CXIM-V1.0 27/02/2013
BEFORE PLUGGING
IN AND POWERING S C C 0 L H P O S B O C L S S S T
T
U U
U D D U
UP CHECK C H L V N
N 1 1 R F
P
F
E S S G S
P G S S
T
L
D D
C C
L
M M M
U C D
L L
U
L
L
M M
1 2
1
CH1 TO EARTH
AND
CL1 TO EARTH
TO SEE IF ANY X9 X10 X11
X12 X13
SHORTS EXIST AS
THIS WILL STOP
COMMS OR DAMAGE
THE NODES
T
S C C 0 L H P O S B O C L S S S T U U
S U D D U
C H L V N P E S S G S T D D
P M M M U M M
L L L L
N 1 1 R F F P G S S L C C U C D L 1 2
1
CONNECTIONS
CONNECTIONS
AND NODE COMMS
LOW VOLTAGE
CIRCUITS
LOCK
LIMIT
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 29
REF: ILE-TS-CXIM-V1.0 27/02/2013
IF EITHER CIRCUIT
M P O O IS NOT REQUIRED +
2
E
R
C C
E E S S T E L L
S P G L REMOVE THE CABLE 4
V
E
T
S N
AND PERMANENTLY
BRIDGE OUT
MOTOR ROOM STOP
X14 SWITCH
X15
X16
CABLE NOT SUPPLIED
PLUG IN TO X14 ON
M P O O
S
E EP S S T THE TERMINAL RAIL FROM FUSED CAR
S P G L
LIGHT SUPPLY
X14
X14
LOOM
PL1336
FIRE RETURN
OVER SPEED SIGNAL
GOVERNOR SWITCH
Trailing flex
The trailing flex comes pre-stripped and cut to the length specified at the time of the survey and is fitted
with plugs for direct connection between the control panel and the car top I/O unit’s terminal rails. The flex
cores are divided in three sections and are marked with the section of terminal rail they plug into. The
control panel connections are marked with an X and the car top I/O’s with a Y and the trailing flex is marked
“car top end” or “controller end” for ease of identification. In actual fact in can be connected either way
around but to keep the correct nomenclature the X and Y connections should be observed. The flex is split
into 3 sections, low voltage and non switching high voltage (cables 1-11+Earth), data (2 twisted pairs) and
high voltage (cables 12-24). There are spare cores and a spare twisted pair. The flex is wound so the
controller end is the 1st off the reel. On request the flex can be wound the opposite way if the installer
prefers. The trailing flex connections can be found at X6, X7 and X8 on the controller terminal rail and at Y4,
Y7 and Y8 on the car top I/O unit’s terminal rail. The connections are detailed on the R1 drawing and a visual
representation of the trailing flex is shown overleaf.
If the trailing flex is too long for the installation it can be cut and stripped to the desired length. The core
numbers to re-make the ends are detailed on the R1 drawing.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 30
REF: ILE-TS-CXIM-V1.0 27/02/2013
+ C T
0 C A C C S C C S C C T C L D D
2 D A T S S S S S S T U
V N B E H L C L L G T T U D D G G
4 Z B S P P P P P P S L
R F + 2 2 N S N S E S L C C S N
V 1 1
Y4 Y6
PLUG IN TO Y4 ON
PLUG IN TO Y6 ON
THE CAR TOP I/O
THE CAR TOP I/O
TERMINAL RAIL OR
TERMINAL RAIL OR
X6 ON THE
X8 ON THE
CONTROLLER
CONTROLLER
TERMINAL RAIL
TERMINAL RAIL
+ C T
0 C A C L D D C C SS C C T C L D D
2SP S D A T S S S S S T U
V N
P B E D D G G LP L GP T T U D D G G
4 Z B S P P P P S L
R F + C C S N S N S E S L C C S N
V 1 1
PLUG IN TO Y5 ON
Y Y THE CAR TOP I/O Y
4 5 6
TERMINAL RAIL OR NOTE: ALL
X7 ON THE TRAILING FLEX
CONTROLLER CONNECTORS AT
TERMINAL RAIL THE CAR TOP I/O
END SHOULD BE
PLUGGED INTO THE
UPPER ROW OF
CONNECTORS
CAR TOP
END
o Car top control (pre-wired to the car top control if an ILE car top control is ordered)
o Detector edge
o Load weighing unit
o Car gate contact
o Safety gear switch
o Car lights
o COP I/O connections
o Proximity switches / tape head (pre-wired to the tape head if an ILE tape head is ordered)
o Door operators either generic VF or specific for ILE supplied door operators.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 31
REF: ILE-TS-CXIM-V1.0 27/02/2013
Most of the car looms are of the open ended type i.e. they are just bare wires at the peripheral end for
wiring into your existing equipment. Please ensure they are wired at the destination end BEFORE connecting
to car top I/O unit especially if the trailing flex is already connected. To keep the car top I/O unit as small as
possible some of the connections are double socket types. All earth connections from each loom need to be
hard wired into the earth connections at either end of the terminal rail.
All car top loom connections can be found on drawing R4 and are detailed in the following sequence of
diagrams.
WE RECOMMEND THAT KG
THE CAR TOP I/O UNIT IS
FITTED VERTICALLY AND
IS FIXED WITH 4
SUITABLE FIXINGS AS
INDICATED BY THE
ARROWS
IF MOUNTED
!! !!
HORIZONTALLY THE
CAR TOP I/O UNIT
SHOULD BE FITTED SO
IT IS NOT EASILY
STEPPED ON
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 32
REF: ILE-TS-CXIM-V1.0 27/02/2013
KG
CABLES SHOULD BE
!! !! !! !!
PLUGS SHOULD NOT BE
TIED BACK TO THE EMC
LEFT SO THE WEIGHT OF
RAIL SO NO UNDUE
THE CABLE CAN CAUSE
PRESSURE CAN BE
UNDUE PRESSURE ON
EXERTED ON THE
THE CONNECTION
PLUGS
The door operator loom is supplied for VF door operators is supplied in 2 different guises, either generic to
suit most VF operators or specific for ILE supplied door operators. See the spare part section of this manual
for specific part numbers. Any other type of operator would have a custom loom. The door operator
connection can be found on the R4 drawing.
The drawing overleaf shows the car top control and door operator connection points on the car top I/O
terminal rail.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 33
REF: ILE-TS-CXIM-V1.0 27/02/2013
L
+ + + L + + C T + + C
C U D D D D 0 W 0 C A C C S C C S C C T C L D D D D D T T T A D D A 0 C C S C C A A
2 2 R D D S 2 W 2 2 D A T S S S S S S T U 2 2 T A T
E E L P N G O C V 1 V N B E H L C L L G T T U D D G G G G L R U D D T T B V L L G T D F F E E
4 4 S O C E 4 9 4 4 Z B S P P P P P P S L 4 4 S B S
S V V C L L R 1 R F + 2 2 N S N S E S L C C S N N S R S P N O O C + R N T S E C 1 2
v v V 0 V V 1 1 V V 1
0
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11
CONNECT CONNECT
THE EARTH THE EARTH
WIRE TO PLUG Y2 THE CAR WIRES TO
ANY TOP CONTROL INTO ANY
AVAILABLE THE TOP ROW OF AVAILABLE
EARTH D
S
G D D
P S
D D
S
+
2 SOCKETS AND Y6
C C S C C
S
P S
C
T
T
T
U
D D +
2SP
T T T
T SP
A D D A
A
0 EARTH
P O C L L G
P T T U G G R U D D T T B V
TERMINAL C O C L L E 4
V INTO THE BOTTOM
S N S E S S
1
L
L
1
S N 4
v
S
S P N O O C +
B
R TERMINAL
ROW OF SOCKETS
Y2
Y6
Y8
Y6
Car gate switch, safety gear switch, car lights, load weighing and COP loom connections
The car gate switch, safety gear switch and the car lights connections are achieved using the supplied 3 core
cables. They connect into Y11, Y10 and Y9 respectively on the car top I/O terminal rail and the loom part
numbers are PL1340, PL1341 and PL1342.
The COP has a 5 core cable and a shielded twisted pair cable it comes pre-wired to the COP I/O din rail ready
to mount in the COP. It plugs into Y4, Y5 and Y8.
The load weighing connections are achieved using a 5 core cable. It connects to Y3 on the car top I/O
terminal rail and the loom part number is PL1339. (This is prepared for the LLEC5 and 6 load weighing units
supplied by ILE if any other unit or supply voltage is required contact ILE for support)
Refer to the R4 drawing for the connections and core numbers. The drawing overleaf shows their connection
points on the car top I/O terminal rail.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 34
REF: ILE-TS-CXIM-V1.0 27/02/2013
CONNECT
THE EARTH
WIRES TO
ANY
+
C
+
U D D D D
+
0
L
L
W
+ +
0 C A C C S C C S C C
C
T
T
C L D D D D D
+ +
T T T A D D A 0 C C S C
C
C A A
AVAILABLE
2 2 R D D S 2 W 2 2 D A T S S S S S S T U 2 2 T A T
E E L
4
S
4
P N
V V
S
G
C
O C
O C
L L
E 4
V
R
9
1
1
4 4
V N
R F
Z
B
+
B S P
E
P P P P P
H L
2 2
C L L G T
N S N S E
T
S
S
U
L
L
D D G
C C S
G
N
G G L
N S R
4 4 S
R
S
U D D T T B
P N O O C +
B
V
R
L
N
L
T
G T
S E
S
D
C
F F
1 2
E E
EARTH
v v V 0 V V 1 1 V V 1
0
TERMINAL
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11
CONNECT
THE EARTH
WIRE TO
ANY
AVAILABLE PLUG Y4 INTO THE PLUG Y5 AND Y8 INTO
L
EARTH 0
L
W
W
+
2
+
2
0 BOTTOM ROW OF C C S THE BOTTOM ROW OF A C C S C
C
C
V 1 V H L C A T
B L L G T D
TERMINAL R
9
0
1
4
V
4
V
R SOCKETS 2 2 N SOCKETS +
B
N T S E
S
C
0 1
Y10
Y11
Y5
Y4 Y8
Y3
Y9
24VDC
90% SUPPLY TO THE COP
+ - NODES (SEE
110%
SEPARATE
CONNECTION
DIAGRAM)
SAFETY GEAR CAR GATE
CAR LIGHTING
SWITCH SWITCH
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 35
REF: ILE-TS-CXIM-V1.0 27/02/2013
L
+ + + L + + C T + + C +
C U D D D D 0 W 0 C A C C S C C S C C T C L D D D D D T T T A D D A 0 C C S C C A A T 0
2 2 R D D S 2 W 2 2 D A T S S S S S S T U 2 2 T A T P 1
E E L P N G O C V 1 V N B E H L C L L G T T U D D G G G G L R U D D T T B V L L G T D F F E E H V
4 4 S O C E 4 9 4 4 Z B S P P P P P P S L 4 4 S B S N 2
S V V C L L R 1 R F + 2 2 N S N S E S L C C S N N S R S P N O O C + R N T S E C 1 2 S R
v v V 0 V V 1 1 V V 1 V
0
Y4
Y1
Y7
Y1
Y4
LIVE
230VAC
UPV
NEUTRAL
YOP
DNV
CONNECTED TO Y1 & Y4
INSTEAD OF PROXIMITY
RS SWITCHES TAPE HEAD
(IF FITTED)
(SEE R4 DRAWING FOR
CONNECTIONS)
COP connections
The I/O for the COP (car pushes, Door open push, Door Close push and Service control) are fitted to a din rail
for mounting behind the COP. The din rail also includes the ILE serial speech unit (if ordered). This complete
unit is pre wired to the COP loom for plugging directly into the car top I/O unit. Wires are included in the
loom for connecting to the alarm push and to an ILE position indicator. The car pushes then have to be hard
wired into the node(s). (The wiring is not included unless pre-wired by ILE)
The COP connections can be found at Y4, Y5 and Y78 on the car top I/O unit’s terminal rail.
NOTE: The COP loom does not contain any wires for auto diallers or pictograms.
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 36
REF: ILE-TS-CXIM-V1.0 27/02/2013
The panel test connection can be found at X5 on the controller terminal rail.
PANEL TEST
+
O C P
T
P P
2
OVERIDE UP DOWN
S T T T T
R 4
G E R U D
V
NORMAL
X5
PANEL TEST UNIT PL1322PW
PLUG IN TO X5 ON
THE TERMINAL RAIL
+
O C PS P P
S T 2
S
P T TP T T
R 4
G E R U D
V
X5
Technical support
ILE technical support can be contacted if any problems occur or advice is needed during installation. They
can be contacted on:
0116 2690900 Monday – Thursday 8-30am – 5.00pm and Friday 8.30am – 4.00pm
London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900
London Fax: 0208 531 0936 Leicester Fax: 0116 269 0939
Website: www.ileweb.co.uk Email: service@ilegroup.co.uk
We reserve the right to alter without giving prior notice technical data dimensions and weights described in this manual
International Lift Equipment Ltd : Can-X Installation Manual Page 37