COMPARISON BETWEEN INDUS

BHOPAL BYELAWS FOR INDUSTRIAL BUILDINGS


SL. NO. CODE BYELAW

AMENITY OPEN SPACE IN INDUSTRIAL


USE; IN EVERY INDUSTRIAL ZONE, 5 PER
CENT OF THE TOTAL AREA SHALL BE
RESERVED AS OPEN SPACE. THESE
OPEN SPACES MAY BE USED FOR
PAKING, BANKING,
CANTEENS,WELFARE CENTERS AND
SUCH OTHER COMMON PURPOSES AS
1 48(1) APPROVED BY THE AUTHORITY.

OPEN SPACE IN INDUSTRIAL PLOTS; IN


INDUSTRIAL PLOTS MEASURING 1000
SQUARE METERS OR MORE, 10
PERCENT OF THE TOTAL AREA SHALL BE
PROVIDED AS AN AMENITY OPEN
SPACE. SUCH AN AMENITY OPEN SPACE
SHALL HAVE A MEANS OF ACCESS AND
SHALL BE SO LOCATED THAT IT WOULD
BE CONVINIENTLY UTILISED BY THE
2 48(2) PERSONS WORKING IN THE INDUSTRY.
3 48(3) NORM FOR INDUSTRIAL PLOTS

MINIMUM MOS IN METERS

SL.NO. MINIMUM PLOT AREA MAX GROUND COVERAGE FRONT


1 UPTO 0.045 HECT. 60 3.2M
MORE THAN 0.045 HECT. AND UPTO
2 0.1 HECT. 60 4.5M
MORE THAN 0.10 HECT. AND UPTO 0.2
3 HECT. 60 7.5M
MORE THAN 0.20 HECT. AND UPTO
4 0.50 HECT. 60 9M

MORE THAN 0.50 HECT. AND UPTO


5 0..75M 60 12M
MORE THAN 0.75 HECT. AND UPTO 1
6 HECT. 60 15M
MORE THAN 1 HECT. AND UPTO 1.25
7 HECT. 60 18M
FOR FLATTED INDUSTIRES (MIN PLOT
8 AREA 1500SQM) 50 12M

(1) Use premises permitted in land use


classifications Subject to other
provisions of this rule following
Industries are permitted in Residential
Rr. R2 Zone and Commercial Zones
Industries listed in Part-1 of Appendix-F
may be allowed in Zone R1 Provided
that not more than 5 workers at a time
are employed In such industry and it
does not employ or use any steam,
electricity. oll, water or any other
37(I) mechanical power:

Provided further that the industries


listed at Serial Number 1 to 38 of
Appendix-F may be permitted with the
use of electric power load of maximum
1.00 K.W.

Industries listed in Part 1 and II of


37(II) Appendix-F may be allowed in R2 zone:

Provided that an indsutry in part II uses


only electricity with a maximum load of
power indicated indicated against each
other and as per conditions laid down
therein;

Industries listed in part III of appendix F


with a maximum power load of 5kw
may be allowed in commercial zone, in
addition to industries listed in part I and
37(III) part II
WIDTH OF MEANS OF ACCESS IN LENGTH OF MEANS OF
38(4) (b) METERS ACCESS IN METERS
12 200
15 400
18 600
24 ABOVE 600
TWEEN INDUSTRIAL BYELAWS OF BHOPAL AND GUWAHAT
LDINGS ASSAM BYE LAWS FOR INDUSTRIAL
Sl. No. BYELAW

Road width

PARKING SPACE

MINIMUM MOS IN METERS MAX


FLOOR
AREA
SIDE/SIDE REAR RATIO
2.1M/2.1M 2.1M 1.25 REGULATION FOR INDUSTRIAL

3M/3M 3M 1.25
SL . NO.

3.75M/3.75M 4.5M 1 REQUIREMENT


1
4.5M/4.5M 4.5M 1 Minimum size of plot

2 Minimum set back of all structure/ building or


6M/6M 6M 1 the structure from the prescribed street line set

7.5M/7.5M 7.5M 1
3

MINIMUM SET BACK


3

9M/9M 9M 1 MINIMUM SET BACK


4
7.5M/7.5M 7.5 1.5 MAXIMUM HEIGHT

CLAUSE NO.

BYE LAW

26
INDUSTRIAL BUILDING
The base FAR, maximum permissible FAR and
maximum permissible Ground Coverage for
industrial buildings shall be as prescribed in
1(B) following table.

DEVELOPMENT INTENSITY ZONE

HIGH INTENSITY
MODERATE INTENSITY
LOW INTENSITY
VERY LOW INTENSITY

ANNEXURE Minimum No. of Off-Street Parking


(1) For calculation of scooter parking space, one
car parking space will be equivalent to 6
scooter parking. (2) 2.5 car parking space will
be equivalent to one parking space of heavy
vehicle in idustrial and whole sale, warehouse
buildings

115 RE-USE OF RECYCLED/WASTEWATER.

Every group housing scheme/apartment houses


and commercial complexes/ institutional
buildings shall be provided with installation of
system of recycling of wastewater from
bathrooms and kitchen sinks (excluding water
closets). The final treatment plant should
recycle water which should be re-used for
purposes other than drinking such as
gardening, landscaping, and washing of
roads/pathways and so on. Accordingly the
space for a wastewater treatment plant is
mandatory to be proposed in the layout and
constructed as per the approved norms and
specifications in case of-

(c) commercial Complexes / Institutional / Hotel


and Lodges/Industrial Buildings etc. if the built-
up area is 1500 Sqm and more or water
consumption is 20,000 liters per day.

For outlet from the soak-pit to municipal drain


94(1) if provided an intermediate treatment chamber
should be installed, details of which is to be
shown in service plan, subject to approval of
the Authority;

(i) The space for a STP is mandatory to be


proposed in the layout/service plan and
constructed as per the approved norms and
specifications in case of,-

(ic) commercial Complexes/Institutional/Hotel


and Lodges/ Industrial Buildings etc. if the built-
up area is above 2000 Sq.m. or water
consumption is 20,000 liters per day;
For the hazardous and industrial building the
95 Authority shall ask for NOC from the State
Pollution Control Board.
All buildings which are more than 15.8 m in
height and all buildings used as educational,
assembly, institutional, industrial store and
hazardous occupancies and mixed occupancies
having area more than 500 sq. m. on every
floor shall have minimum two staircases. At
62(c)
least one of them be on external wall of
buildings and shall open directly to the
exterior/ interior open space as to an open area
of safety. The provision of alternative staircase
shall be subject to the requirement of travel
distance being complied with.
D GUWAHATI
BYE LAWS FOR INDUSTRIAL BUILDINGS
fig.

OUTSIDE GMC
BUT INSIDE
GMC area=15 M GMA= 18M

ONE CAR PARKING SPACE FOR


EVERY
CAR SCOOTER

100M² 20m²

EGULATION FOR INDUSTRIAL ZONE

LIGHT MEDIUM

AREA IN SQM WIDTH IN M AREA IN SQM WIDTH IN M

744 15.5 1800 27.5

FRONT 6 FRONT 9

REAR 6 REAR 6
SIDE 5 SIDE 6

15M 15M

BYE LAW

MAXIMUM GROUND
BASE FAR PERMISSIBLE FAR COVERAGE

1 1.75 40%
1 1.5
0.7 1 30%
0.4 0.7 25%

mum No. of Off-Street Parking space