Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Distributed Starters with

Local Intelligence for Increased Efficiency


Bulletin 100 The functionality of the DeviceLogix module is easy configured
DeviceNet Starter Auxiliary Module with DeviceLogix by using the software platform RSNetWorx™ which is commonly
used when working with the DeviceNet Network. RSNetWorx
The DeviceNet Starter Auxiliary (DSA module enables a simple allows to work on the screen with drag and drop functions for a
integration of contactors and sensors into the DeviceNet net- fast and efficient set-up of the modules.
work. Especially components with lower I/O requirements
(e.g., 4 inputs and 2 outputs) are are suited to be connected. Starter Module Characteristics
• DeviceLogix component technology
The DSA has high-capacity outputs that eliminate the need for • 24 VDC or 120 VAC inputs
interposing relays. This makes the DSA ideal for the use with • High-capacity transistor or relay outputs
motor starters, circuit breakers, contactors, motor protectors, • Diagnostics via communication
softstarters, sensors and actuators. • Rotary node address switches
• Reduced engineering, installation and startup costs
The DeviceLogix component technology incorporated into the
DSA allows it to be programmed with up to 48 function blocks to
execute simple logic – elementary supervision and control tasks
– locally. The local intelligence frees controllers and networks Decentralised Architecture
and increases the efficiency of the systems. This functionality The advantages of Decentralised architecture:
can be used to solve high-speed applications, controlled shut • Reduced wiring
down, or other local operations, such as Star-Delta motor starts • Simplified connectivity
without the necessity to equip the starter with a timing module. • Minimised space requirements

Control Device

Decentralized
DeviceNet™ Starter

Motor
DeviceNet Starter Auxiliary Module
with DeviceLogix

Specifications

DeviceLogix is implemented on the DSA Series B. Configuring


these devices requires RSNetWorx Revision 3.00.00 Service pack 2 or higher.

Network Inputs 16
Network Outputs 8
Max. function Blocks 42
Boolean function Blocks AND, NAND, OR, NOR, XOR, XNOR, NOT
Latch function Blocks RS Latch, SR Latch
Counter function Blocks Up Counter, Up/Down Counter
Timer function Blocks Pulse Timer, On delay -, Off delay Timer
Execution Time 16 function Blocks/ms

Product Selection

Inputs Outputs Cat.No.

4 AC (120 VAC) 2 Relays 100-DNY41R


(240 VAC/30 VDC)
4 DC (24 VDC) 2 Relays 100-DNY42R
(240 VAC/30 VDC)
4 DC (24 VDC) 2 Solid State 100-DNY42S
(15-30 VDC)

Publication 100-PP021A-EN-P July 2001 © 2001 Rockwell International Corporation. All rights reserved.