STEAM TURBINE WITH ACCESSORIES
SA 00-: 1x Impulse blades type steam condensing turbine with single controlled extraction before LP turbine.
Rated power measured on the generator terminals at the heat off take for desalting station of
171 G. cal/h 160 000 kW
Rated speed = 3000 RPM
Rated steam pressure close before HP Emergency stop valve =126 bar
0
Rated steam temperature close before HP Emergency stop valve =510 C
Pressure at HP cylinder outlet =33.92 bar
Rated steam temperature close before IP Emergency stop valve = 510 0C
Pressure in controlled extraction point = 3.0 bar
Heat removed from controlled extraction point =171 G cal/ h
0
Temperature of return condensate = 99.6 C
0
Temperature of cooling water (circulating water) = 32 C
SA11 – 1x Turbine high pressure part in double shell design including rotor and diaphragms
SA11G411, SA11G412, SA11G413 & SA11G414 – 4x – Steam regulating valve including hydraulic actuator
actuating mechanism, limit switches & position sensor,
Regulating oil pressure approx. 2 ~ 4.0 bar, Maximum
closing speed approx. 0,5 sec.,
SA11G601, SA11G602- 2x – High pressure regulating valve incl. hydraulic actuating mechanism and limit
switches, Tripping oil pressure approx. 15 bar,
maximum closing speed approx. 0.5 sec.,
SA11G616, SA11G617, SA11G621 & SA11G622 4x- Non-return flap valve at HP cylinder outlet,
Tripping oil pressure approx. 15 bar.
SA11G618 1x – HP turbine casing heating up NRV by pass valve including a hydraulic actuating mechanism
SA11G645 1x – Extraction NRV valve with a hydraulic actuating mechanism, HP regulating valves,
interconnecting piping, interconnecting heating through of flanges, heating through of regulating
valve chest including fittings.
SA12 1x – Mean-pressure IP turbine part in double – shell design including rotor and diaphragm.
SA12G601, SA12G602 -2 x – Steam regulating valves include. a hydraulic actuating mechanism and limit switch.
SA12G603, SA12G604 -2x – Mean press. EM stop valve incl. a hydraulic actuating mechanism and valves limit
switch.
nd
SA12G651, SA12G653 2X- Reg. Control valves to control press. In the 2 extraction point, including hydraulic
actuating mechanism and limit switch.
SA12G052, SA12G062 -2x – NRV flap valve closed by gravity and opened by a steam flow, include hydraulic
damping.
SA12G643 – 1x – NRV valve with hydraulic actuating mechanism.
SA12G644 – 1x – NRV extraction valve with a hydraulic actuating mechanism, nozzle boxes of IP regulating and
EM stop valves, inter connecting heating – through of flanges,
heating through of chests, transfer piping between turbine IP & LP parts.
SA13 - 1x - Turbine Low Press. Part, including rotor and diaphragm.
SA13G641 – 1x – NRV valve with hydraulic actuating mechanism
SA13G101, SA13G102 - 2x – Safety exhaust diaphragms with exhaust adapters and a set of spare diaphragms.
- piping of injection water for cooling the LP part,
- Protecting device against stray earth currents
SB10 - Bearing pedestals
SB11 - Front bearing pedestal with built in hydraulic regulating system of the turbine
SK12 - 2x Rear bearing HP pedestal,
Rear bearing IP pedestal
SB13 - Rear bearing LP pedestal
SB11A11 - Turning gear with hydraulic damping,
Turning speed - 65.31 1 / min.,
The turning gear is delivered inclusive of a gear box and an electric motor 45 kW, 380 V , 3000 RPM.
SB24 - Turbine drying equipment, the drying equipment consists of following parts:
SB24A10 – Air dryer equipment Munters , Inlet air parameters, Outlet air parameters, Air pressure at
Outlet, Electric power input 5.4 kW, 380 V.
SB20A20 - - Drying equipment fan.
2
SC - Turbine Oil system
3
SC17N01 – 1x – Magnetic filter for building in piping, Rated flow rate – 160 1/min, Press. Loss 0, 07 bar, Mesh
size = 63 µm
SC17N02, 03, 04, 05 – 4x – Magnetic filter for building in the piping,
Rated flow rate- 250 1 / min, Press. Loss = 0, 07 bar, Mesh size = 250 µm
SC17N10, N20- 1x – Vertical design Fine duplex filter for oil,
Rated flow rate = 132 m3/h, Press. Loss in clean filter = 0.15 bar, Mesh size = 40 µm.
• The filter is delivered inclusive of shift – over valves.
SC17Z - -
SC18 - 2x - Shifting of lifting oil
SC18A21 - Gear pump with electric motor,
Output = 37 kW for voltage of 380 v, Capacity = 6,6 m3/h, Pressure on delivery branch = 160 bar
• The pump is equipped with a safety by pass valve.
SC18N10, N20 – x1- Vertical design fine duplex filter for oil,
Rated flow rate = 7, 2 m3/h, Press. Loss in clean filter = 0, 15 bar. Mesh size = 40 µm.
SC18Z –
SC19 - - System of primary oil
- Primary oil pressure source.
- Pipe distribution system, local measuring devices, manostats, electro magnets
SC22 - - Tertiary oil system.
- Oil transformer to generate pressure.
- Distribution pipes, local measuring devices.
SC40Z -- -SC90Z
4
SD – CONDENSING PLANT
• SD15A10, SD25A10 – 2x- Water jet air pump for evacuation the steam space of the turbine and of the
condenser
- Electric motor vacuum pump type 2BW4303 – OBL4 in a compact design
- Set capacity - 65 kg / h dry air
- Corresponding quantity of air and steam mixture - 230 kg / h
- Pressure in suction part - 0,025 up to 1 bar
• The Set consists of following parts:
- Ejector pump
3
- Capacity - 21 m / h
- Speed - 585 RPM
5
- Quantity of service steam -3t/h
- Quantity of sucked – off air - 1.2 t / h
- Rated pressure in suction part - 0.49 bar
- Minimum pressure in suction part - 0.2 bar
SG41, 42A10- 2x – Lead off tube steam fan / STK steam fan, radial flow centrifugal fan with electric motor,
output = 11 kW, 380 V,
0 3
- Delivered medium – steam – air mixture of = 70 C , 0.88 kg / m
- Delivered quantity = 910 m3 / h
- Static pressure = 1.458 bar
- Power input on shaft = 3. 14 kW
6
• SH - - Turbine dewatering system.
SH1, SH9 - - Dewatering of extraction steam and NR flap valves.
SH10- - HP dewatering system, collecting piping for dewatering of:-
- Steam regulating valves.
- Heating – through pipings
- Return steam and HP cylinder
- Piping for flooding the gland steam system
• SH20 - - IP and LP dewater systems, collecting piping for dewatering of:-
- Steam regulating valves.
- Steam piping to the turbine
- Extraction pipings
- Flange heating – through system.
- Gland steam system.
• SH30 - - Expansion branches of the condenser.
• VC10A10 -1 x – Cooling (sea) water pump, Vertical single-stage tubular pump with mixed flow.
•
- Type: BVa 1800, Producer: Balcke- Ďurr ( FRG)
3
- Capacity - 33250 m / h
- Delivery head - 14 m W.C.
- Speed - 370 RPM.
- Pump power input - 1519 kW
0
- Max. temperature of medium - 35 C
3
- Sea water density - 1,03 t / m
- Max. Pressure at null quantity - 31 m W.C.
- Pump weight with out motor - approx. 35 ton.
• The thrust plain bearing is dripped in oil bath cooled with sea water from cooling and lubricating water
pump (78VC60/ 61A10). Radical bearings on a vertical shaft are lubricated and cooled with sea water
directly, also by means of the above mentioned pump 78VC60 / 61A10.
• Antifriction bearings of the electric motor are lubricated by dripping in the oil bath ( the upper thrust bearing)
and / or by a permanent grease filling ( the lower radial bearing on the motor driving side).
• The electric motor is equipped with necessary measuring instruments and with a heating body of 1600 W,
220 V, 50 C / S prevented condensation.
• 78VC10A10 – 1x- Spare cooling (sea) water pump for units 7 & 8. The data ditto pump VC10A10.
• VC – Delivery piping of the cooling (sea) water pump including expansion bend.
• 78VC10- Delivery piping of the cooling (sea) water pump 78VC10A10, including expansion bend, piping .
• VC10G800 – 1x – combined closing NR butterfly valve with a hydraulic drive.
• 78VC10G800 – Gate valve at the delivery of the emergency pump 78VC10A10, data ditto VC10G800.
• 78VC11 – Delivery piping of reserve cooling sea water pump after fitting 78VC10G800 ( in the pumping
Station object),
• 78VC12 – Piping at the delivery of sea cooling water pumps – interconnection between pumps VC10A10
and 78VC10A10: including expansion bend of diameter 2200.
7
• 78VC12G200- 1x – closing fitting on interconnection pipe between pumps VC10A10 and 78VC10A10
(pipeline 78VC12).
• C11 - - pipeline at the delivery of cooling (sea) water pump VC10A10 (after combined valves VC10G800).
In the pumping station object, this pipe line is carried on 3 sliding supports. In the part between
the pumping stating and entrance to the engine room, the pipe line is led underground in sand
subsoil. ON this part pf the line , there are provided five inspection holes ( utilized also for the
installation of a portable pump, for exhausting the cooling sea water system) and a branch pipe
to water drain basin . In the engine room, the pipe line is led in a concrete channel on the floor at
-5.10 meter on 1 fast and 4 sliding supports. Three branch pipe lines (VC20, VC30 to the
condenser and VC40 to service water coolers) are brought out of this part of VC11 pipeline in the
engine room, and a drain piping.
• VC20 - - Supply and waste pipings to one half of the condenser.
• VC30 - - Supply and waste pipings to the other half of the condenser.
• Pipelines VC20, VC30 are inclusive of drain piping with a closing valve and a sieve and expansion bends at
the condenser inlet and outlet.
• VC20G200 -1x – Closing fitting at the condenser inlet on pipeline VC20,
• VC30G200 -1x - Closing fitting at the condenser inlet on pipeline VC30
• VC40 -- - Common supply piping to service water coolers,
• VC41B100 – drain and dewatering pipings and fittings
• VC42 - - Supply and waste pipings of cooler VC42B100. Drain and dewatering pipings.
• VC42 - - Supply and waste pipings of cooler VC42B100.
• VC41G200 – Closing fitting at the service water cooler inlet VC41B100.
• VC42G200 - Closing fitting at the service water cooler inlet VC42B100.
• VC41B100 – Cooler of service water, Horizontal heat exchanger with a tubular heat exchange surface.
3
Quantity of cooling (sea) water = 3683 m / h
3
Quantity of service water = 1105 m / h
Heat output = 6630000 kcal / h
Sea water max. temperature
0
(Inlet & outlet) = 35 / 36.8 C
Service water max. temperature
(Inlet & outlet) = 46 / 40 0C
Press. Loss (sea water side) = 2.8 m W.C.
Press. Loss (service water side) =13.5 m W.C.
2
Heat exchange surface ( total) = 507.2 m
Main dimensions: dia. x length = 1300 x 8300 mm
Number of tubes = 1300
Dimensions of tubes = dia. 23 x 1.5 mm
• VC42B100 – service water cooler (reserve).
• VC41201 - - Closing fitting at outlet of service water cooler VC41B100
• VC42G201 - Closing fitting at outlet of service water cooler VC42B100.
• VC49 - - Common w3aste piping from service water coolers leading into VC50.
• VC50 - - Common waste piping from the condenser to the siphon trap.
• Note: - All cooling sea waste pipings are coated with polyamide epoxy resin on either side-
for the precise description of transport coat, laying in the channel and / underground see
the Specifications of Voest Alpine.
8
• VG – SERVICE WATER SYSTEM
VG10B01 – 1x –Expansion vessel. Vertical welded cylindrical vessel with built in overflow safety device as
protection against overpressure.
- Vessel height = 2.8 m
- Vessel diameter = 1.1 m
3
- Total volume = 2.5 m
- Weight without water = 923 kP
(Inner protective coat is resisting to demineralized water)
• Overpressure of 1.2 bar abs, in the expansion vessel is held by N2 supplied from a pressure bottle.
• The vessel is outfitted with necessary measuring instruments, an inspection manhole and branches for
connecting the pipings of service water, demineralized water (and/or condensate) and N2 nitrogen.
• VG10A10, A20 -1x – Horizontal single stage centrifugal Service water pump 1 & 2. Type TW 400/ 600,
3
- Capacity = 1105 m / h
- Delivery head = 50 m W.C.
- Speed = 985 RPM.
- Pump power input = 232 kW
- Delivery head at null delivery quantity = 57 m W.C.
• The pump is installed on a common frame with electric motor
- Rated output = 260 kW
- Voltage = 6000 v, 50 C / S.
- Speed = 985 RPM
- Rated current = 36 A
- Power factor = 0.74
- Power input ( at rated load) = 276 kW.
• VG10N10N20 – Filters in service water pumps VG10A10 & A20 suction, vertical welded cylindrical vessel
with five removable sieves of cylindrical shape ( dia. 230 x 992 mm).
The filter is equipped with a filter fouling signaling device to the control room and with a local indicator
of presser loss, drain and deaerating pipings with fittings.
The service water system consists of five separate parallel branches. The flow in every branch is
controlled by a regulating valve with pneumatic drive operated by the pressure difference at the
branch inlet and outlet. All five branches are joined to a single common collecting pipe in the suction
part of service water pumps.
9
- Calculated pressure of injection water = 120 bar
0
- Temperature of injection water = 180 C
10
• RB31,RB41G100 -2x- Direct – acting by pass valve
• RB31,RB41G101 -2x – Pressure governor
• RB31B11,RB41B11-2x- Hydro-pneumatic accumulator
- Nitrogen space volume = 18 l
- Maximum working pressure = 210 bar
- GY51 - Control Box of Local automatics
• RC01, RC02 – Double branch part of cold reheat steam line , pressure = 46 bar, temperature = 420 0C .
- The steam line is provided with necessary adapting pieces.
• RC05 – - HP turbine outlet Cold reheating by pass of NRV flap valve
• RC05G411- - Temperature gradient control valve with electric driven intended for heating HP turbine
casing.
0
• RC 10 - - Single branch part of cold heat steam line, pressure = 46 bar, temperature = 420 C.
- The steam line is provided with necessary adapting pieces.
0
• RC11 - - Supply piping for flooding the turbine glands, pressure = 46 bar, temperature = 420 C
0
• RC12 - - Supply piping for flooding the IP turbine check valves, pressure = 46 bar, temp. = 420 C
0
• RC20 - - Piping for steam extraction from CRH steam system, press. =46 bar, temp.= 420 C
0
• RC21 - - CRH steam piping for step-down station RQ20, Press. =46 bar, temp.= 420 C
• RC22 - - CRH steam piping for alternate (in absence of turbine) heating of the HPH NO. 2 , equipped
with NRV , a motor operated closing valve
• RC24 - - Heating up piping for step down station – RQ20
• RC25 - - CRH steam supply piping for heating steam for HPH no. 2
• RC30 - - Single branch part piping from HP by Passes outlet
• RC31 - - Outlet steam piping from HP by Pass RA30
• RC32 - - Outlet steam piping from HP by Pass RA40
th
• RF10 - - Heating steam piping from the turbine 4 extraction point to HPH NO.1,
0
Press. 22 bar, temp. 425 C
• RF10B10- - HP heater No. 1 of feed water, heating with extracted steam from the IP turbine casing.
•
Vertical exchanger with tubular heat exchange surface.
- Number of tube ------------------------------ = 1120
- dimension of tubes = dia. 16 x 2 mm
2
- total heat exchange surface = 712 m
2
- effective de-superheating zone = 112.6 m
2
- effective condensing surface = 464.7 m
- effective sub-cooling surface = 87.4 m2
- heat output = 26.6 MW
- pressure loss at MCR = 0.486 bar.
0
- dimension of steam side = 22 bar, 425 C temp.
0
- dimension of water side = 242 bar, 240 C temp.
3
- steam space volume = 8.9 m
3
- tubular part volume = 2.4 m
• RF20B10- - HP heater No. 2 of feed water, heating with steam from outlet of HP turbine casing.
11
2
- total heat exchange surface = 781 m
2
- effective de-superheating zone = 118 m
2
- effective condensing surface = 536 m
2
- effective sub-cooling surface = 60 m
- heat output = 29.97 MW
- pressure loss at MCR = 0.466 bar.
0
- dimension of steam side = 53 bar, 425 C temp.
0
- dimension of water side = 242 bar, 240 C temp.
3
- steam space volume = 8.3 m
3
- tubular part volume = 2.5 m
• RH10- - heating steam piping from the turbine first extraction point to the LP heater NO.1,
0
Press. = 2.71 bar, temp.= 294 C.
st
• RH10B10- LP heater no. 1 of turbine condensate, heated with extraction steam from turbine 1 extraction
point.
Vertical exchanger with tubular heat exchange surface.
- number of U tubes = 707
- dimension of tubes = dia 16 x 1.25 mm
2
- total heat exchange surface = 476 m
- effective de-DE superheating zone =-
- effective condensing surface = 409 m2
- effective sub-cooling surface =0
- heat output =
- pressure loss at MR = 0.072 bar.
0
- dimension of steam side = 2.71 bar, 235 C temp.
0
- dimension of water side = 30 bar, 125 C temp.
3
- steam space volume = 6.5 m
3
- tubular part volume = 2.7 m
nd
• RH20B10- LP heater no.2 of turbine condensate, heated with extraction steam from turbine 2 extraction
point.
Vertical exchanger with tubular heat exchange surface.
- number of U tubes = 617
- dimension of tubes = dia 16 x 1.25 mm
2
- total heat exchange surface = 422 m
- effective de-DE superheating zone =-
- effective condensing surface = 330 m2
2
- effective sub-cooling surface = 33 m
- heat output = 27 MW
- pressure loss at MR = 0.095 bar.
0
- dimension of steam side = 16.5 bar, 355 C temp.
0
- dimension of water side = 30 bar, 170 C temp.
3
- steam space volume = 5.6 m
3
- tubular part volume = 2.25 m
st
• RH20B11 – Expansion pipe for expansion of condensate from the 1 HP heater.
nd 0
• RH21 - - Steam piping from turbine 2 extraction point to the desalination, press. =10 bar, temp.=450 C
The piping equipped a NRV flap with electrical driven
nd
• RH22 - - steam piping from the turbine 2 extraction point to the safety valve, press. 10 bar, temp.=
0
400 C
- The piping equipped with an impulse safety valve, opening press= 9.50 bar, capacity = 76.7
t/h,
12
nd
• RH23 - - Steam piping from turbine 2 extraction point to the safety diaphragm, press. = 10.0 bar,
temp.= 400 0C.
-The piping is equipped with safety head SKQ with breaking disk NB600, rated breaking
pressure of 13.10 bar, capacity = 590 t / h with an exhaust branch extension.
rd
• RH30- - Steam piping from the turbine 3 extraction point to the feed water deaerator, press. = 13 bar,
0
temp.= 400 C.
- The piping is equipped with an electrical valve and a NRV
• RJ01-RJ04, - Piping for deaeration of the main condensate line and drain piping
• RL01B10 - - Feed Water Tank with Deaerator, Horizontal cylindrical tank with a built in deaerator of the
Stork system
• The tank is seated on two steel bases of which one is stationary and the other sliding.
• the tank is outfitted with local measuring instruments and two safety valves: -
- RL01G104, RL01G105, opening pressure = 13.5 bar, Capacity = 50 t /h
13
• RL11 - - Suction piping of feeding set
- The piping is equipped with two hand operated closing valve.
• RL11A10- - Booster pump for boiler single-stage centrifugal feed pump.
3
- delivered quantity = 507 m / h
- pressure increase = 3.57 bare
- speed = 1490 RPM
0
- maximum temperature of medium = 180 C
• RL11Z001 – Coarse screen built in the suction part of the booster pump
• RL12 - - Transfer piping between the delivery side of the booster pump and suction side of the high-
pressure boiler feed pump.
• RL- - Heating piping of feed pump.
• RL12A10 - High pressure FW pump of the boiler in the barrel design
- A high – speed five stage centrifugal pump
- Type TSH - T – 150 – 5 = ( Balcke Dürr)
3
- Deliver quantity = 475 m / h
- Delivery Head = 1967 m L.C.
- Maximum speed = 5387 RPM
0
- Maximum temperature of medium = 180 C
- Max. press. On delivery branch/quantity = 193 bar, 410 t / h
- Max. pressure at null quantity = 242 bar
st st
- 1 intermediate extraction after the 1 stage = 55 t / h
nd nd
- 2 intermediate extraction after the 2 stage = 55 t / h
- Closing pressure of the 1st intermediate extraction = 56 bar
nd
- Closing pressure of the 2 intermediate extraction = 110 bar
• RL13 - - Lubricating oil duplex filter type SV with a magnetic element and change-over valve.
- the filter is equipped with a signaling device when filter fouling at ∆P = 0.6 bar
• RL13A - Hand operated pump for discharging the oil tank of the hydraulic gear box.
• EL14A10 - - Electric motor of feeding set with accessories
- Power = 3650 kW
- Voltage = 6000 V
- Speed = 1484 RPM
14
- Rated current = 415 A
• The electric motor is provided with pressure oil lubrication.
• RL14B10 - - Electric motor Cooler
3
- Cooling water quantity = 21 m / h
- Pressure loss = 0.2 bar
- Heat output = 135 kW
• RL15 - - Piping of the first intermediate extraction inclusive of NRV and an electrical valve.
• RL16 - - Piping of the first intermediate extraction inclusive of NRV and an electrical valve.
• RL18 - - Equipment of the minimum rate of flow.
• RL18G211- - Multistage throttle valve with electric drive.
- Rate of flow = 65 t / h
- Differential pressure = 205 bar.
• The valve is controlled by the difference of the rate of flow by means of nozzle RL12F01 and
orifice plates RL15F01 and RL16F01.
• RL18Z001- - A remotely hand operated electrical valve is a part of the by pass valve RL18G211.
• RL19 - - Delivery piping of feed pump.
- The piping is equipped with accessories, a NRV with extraction for the minimum rate of
flow, an electrical valve , an electrical by pass valve and local measuring instruments.
15
• RL23A01 - - Pre- lubricating gear type pump with electric motor
- Power = ----- kW, 380 V
• RL23 - - Lubricating oil duplex filter type SV with a magnetic element and change-over valve.
- the filter is equipped with a signaling device when filter fouling at ∆P = 0.6 bar
• RL23A - Hand operated pump for discharging the oil tank of the hydraulic gear box.
• EL24A10 - - Electric motor of feeding set with accessories
- Power = 3650 kW
- Voltage = 6000 V
- Speed = 1484 RPM
- Rated current = 415 A
• The electric motor is provided with pressure oil lubrication.
• RL24B10 - - Electric motor Cooler
3
- Cooling water quantity = 21 m / h
- Pressure loss = 0.2 bar
- Heat output = 135 kW
• RL25 - - Piping of the first intermediate extraction inclusive of NRV and an electrical valve.
• RL26 - - Piping of the first intermediate extraction inclusive of NRV and an electrical valve.
• RL28 - - Equipment of the minimum rate of flow.
• RL28G211- - Multistage throttle valve with electric drive.
- Rate of flow = 65 t / h
- Differential pressure = 205 bar.
• The valve is controlled by the difference of the rate of flow by means of nozzle RL12F01 and
orifice plates RL15F01 and RL16F01.
• RL28Z001- - A remotely hand operated electrical valve is a part of the by pass valve RL18G211.
• RL29 - - Delivery piping of feed pump.
- The piping is equipped with accessories, a NRV with extraction for the minimum rate of
flow, an electrical valve , an electrical by pass valve and local measuring instruments.
16
• RL45 - - By pass piping of HP heater.
• RL45G801, 802– Set of change over valves with impulse controlling by the FW pressure.
• RL50 - - FW piping from the change-over valves to the feeding head of the boiler.
0
• RL70 - - Injection water piping for the reheater and HP by passes. 110 bars temp. = 200 C
• RL80 - - Injection water piping for the desalination and step-down station, press.60 bar,
0
temp.=200 C
17
• RN HEATING STEAM CONDENSATE SYSTEM
st
• RN - Condensate discharge piping from the 1 LP heater, piping dimensions = dia 219 x 6 mm
- The piping is equipped with hand operated valves with the flooded gland, a pneumatic regulating
valve and accessories.
• RN10B10 – A Cylindrical surface exchanger with a tubular heat exchange surface in horizontal design
Condensate water cooler for the 1st LP heater.
2
- Rated heat exchange surface = 128 .3 m
-
Number of passes =2
- Number of U tubes = 1296
- Dimension of U tubes = 16 x 1.25 mm
- Heat output = 6.02 MW
- Pressure loss at MR
- Content Shell space = 0.87 m3
3
- Content of tube space = 0.90 m
st
• RN1 - - Condensate discharge piping from the 1 LP heater.
• RN20 - - Condensate discharge piping from the 2nd LP heater to the 1st LP heater. The piping is equipped
with accessories, a pneumatic regulating valve and hand operated closing valves.
nd
• RN21 - - Condensate discharge piping from the 2 LP heater to condenser . The piping is equipped with
necessary accessories, a pneumatic regulating valve and a hand operated closing valve.
st
• RN23 - - Return condensate piping from the 1 desalination unit. The piping is equipped with necessary
accessories and a NRV.
nd
• RN24 - - Return condensate piping from the 2 desalination unit with a branch to the condenser. The
piping is equipped with necessary accessories, a NRV, an electrical valve, a hand operated
valve and a limiting orifice plate.
• RN25 - - Return condensate piping from the desalination unit to deaerator. The piping is equipped with
necessary accessories, an electrical valve.
• RN29 - - Branch pipe from the return condensate piping for deaerating the service water system.
• RN30 - - Collector for drains at the condenser, dia. 1016 x 12 mm.
18
• RQ - - AUXILIARY STEAM SYSTEM
• RQ10 - - Distribution piping of auxiliary steam of 3.5 bar for the deaerator.
• RQ10G491- Pressure and temperature step down station for emergency heating of the deaerator supplied
with hot reheated steam.
- Hot reheated steam = 30 bar
- Admission pressure = 3.5 bar
- Outlet pressure = 3.5 bar
0
- Admission temperature = 515 C
- Outlet temperature = 300 0C
- Outlet quantity = 70 t / h
- Seat diameter = 155 mm
- Kv min. = 11.2
- KV max. = 280.7
The step down station is equipped with a distributor, heating through system, necessary
valves, by-pass and local measuring instruments.
• RQ20 - - Distribution piping of auxiliary steam of 13 bar, 200 0C including secondary distributors in the
scope as per the flow diagram 3970 VS2471 R003.
• RQ20G491- Pressure and temperature step down station for the auxiliary steam system, supplied with
steam from the cold reheat.
- Admission pressure = 34 bar
- outlet pressure = 13 bar
0
- admission temperature = 330 C
0
- outlet temperature = 200 C
- outlet quantity = 40 t / h
- seat diameter =110 mm
- Kv min. = 59
- Kv max. = 206
- The step down station is equipped with a distributor, heating through system, necessary
valves, remotely controlled by pass and local measuring instruments.
• RQ30 - - Distribution piping of auxiliary steam for the steam cushion of cold condensate storage tank
• RQ30G491 - - Pressure and temperature step down station for the steam cushion of the cold condensate
storage tank. Supplied with steam from the 3rd extraction point of the turbine.
- admission pressure = 6.2 bar.
- outlet pressure = 1.1 bar
0
- admission temperature = 304 C
0
- outlet temperature = 120 C
- outlet quantity =2t/h
- seat diameter = 65 mm
- The step-down station is equipped with a by pass and necessary valves.
• RT10, 20A10 – 2x – Horizontal centrifugal Clean drain pumps, Power = 37 kW, 380 V, 1450 RPM.
3
- Delivery quantity = 30 m
- Pressure increase = 16.35 bar
0
- Max. Temperature of delivered Medium = 100 C
- NPSH = 1.6 m
19
• RT11A10 - - CLEAN DRAINAGEAUXILIARY PUMP
- Single stage horizontal centrifugal pump with electric motor, Power = 1.5 kW, 380 V, 1450
RPM.
3
- Deliver quantity = 20 m
- Pressure increase = 0.8 bar
0
- Max. temperature of delivery medium = 100 C
- NPSH = 1.5 m
• RU50,60A10- 2X –Vertical centrifugal Mud pump with electrical motor, Power = 380 V,
3
- Delivery quantity =5m /h
- Necessary pipings of for mud pumps including valves.
20