STEAM TURBINE WITH ACCESSORIES
SA 00-: 1x Impulse blades type steam condensing turbine with single controlled extraction before LP turbine.
Rated power measured on the generator terminals at the heat off take for desalting station of
171 G. cal/h 160 000 kW
Rated speed = 3000 RPM
Rated steam pressure close before HP Emergency stop valve =126 bar
0
Rated steam temperature close before HP Emergency stop valve =510 C
Pressure at HP cylinder outlet =33.92 bar
Rated steam temperature close before IP Emergency stop valve = 510 0C
Pressure in controlled extraction point = 3.0 bar
Heat removed from controlled extraction point =171 G cal/ h
0
Temperature of return condensate = 99.6 C
0
Temperature of cooling water (circulating water) = 32 C
SA11 – 1x Turbine high pressure part in double shell design including rotor and diaphragms
SA11G411, SA11G412, SA11G413 & SA11G414 – 4x – Steam regulating valve including hydraulic actuator
actuating mechanism, limit switches & position sensor,
Regulating oil pressure approx. 2 ~ 4.0 bar, Maximum
closing speed approx. 0,5 sec.,
SA11G601, SA11G602- 2x – High pressure regulating valve incl. hydraulic actuating mechanism and limit
switches, Tripping oil pressure approx. 15 bar,
maximum closing speed approx. 0.5 sec.,

SA11G616, SA11G617, SA11G621 & SA11G622 4x- Non-return flap valve at HP cylinder outlet,
Tripping oil pressure approx. 15 bar.
SA11G618 1x – HP turbine casing heating up NRV by pass valve including a hydraulic actuating mechanism
SA11G645 1x – Extraction NRV valve with a hydraulic actuating mechanism, HP regulating valves,
interconnecting piping, interconnecting heating through of flanges, heating through of regulating
valve chest including fittings.
SA12 1x – Mean-pressure IP turbine part in double – shell design including rotor and diaphragm.
SA12G601, SA12G602 -2 x – Steam regulating valves include. a hydraulic actuating mechanism and limit switch.
SA12G603, SA12G604 -2x – Mean press. EM stop valve incl. a hydraulic actuating mechanism and valves limit
switch.
nd
SA12G651, SA12G653 2X- Reg. Control valves to control press. In the 2 extraction point, including hydraulic
actuating mechanism and limit switch.
SA12G052, SA12G062 -2x – NRV flap valve closed by gravity and opened by a steam flow, include hydraulic
damping.
SA12G643 – 1x – NRV valve with hydraulic actuating mechanism.
SA12G644 – 1x – NRV extraction valve with a hydraulic actuating mechanism, nozzle boxes of IP regulating and
EM stop valves, inter connecting heating – through of flanges,
heating through of chests, transfer piping between turbine IP & LP parts.
SA13 - 1x - Turbine Low Press. Part, including rotor and diaphragm.
SA13G641 – 1x – NRV valve with hydraulic actuating mechanism
SA13G101, SA13G102 - 2x – Safety exhaust diaphragms with exhaust adapters and a set of spare diaphragms.
- piping of injection water for cooling the LP part,
- Protecting device against stray earth currents
SB10 - Bearing pedestals
SB11 - Front bearing pedestal with built in hydraulic regulating system of the turbine
SK12 - 2x Rear bearing HP pedestal,
Rear bearing IP pedestal
SB13 - Rear bearing LP pedestal
SB11A11 - Turning gear with hydraulic damping,
Turning speed - 65.31 1 / min.,
The turning gear is delivered inclusive of a gear box and an electric motor 45 kW, 380 V , 3000 RPM.
SB24 - Turbine drying equipment, the drying equipment consists of following parts:
SB24A10 – Air dryer equipment Munters , Inlet air parameters, Outlet air parameters, Air pressure at
Outlet, Electric power input 5.4 kW, 380 V.
SB20A20 - - Drying equipment fan.

2
SC - Turbine Oil system

SC10A01 - 1x – Booster Ejector

SC10A50 - 1x – Hand operated pump,


Capacity - 53.5 1/ min, Suction head – 7 m W.C., Delivery head – 20 m W.C.

SC10A31 - 2x – Oil vapour fan type Geistler with electric motor,


Capacity – 720 m3 / h, Pressure in suction branch – 0,99 bar.
SC10A41, SC10A42 – 2x – Non sealing oil pump,
3
Gear pump with electric motor out put 4.0 kW, voltage – 380 v, Capacity – 15 m / h, Press.
On delivery branch – 2.4 bar.
SC10B01 – 1x – Lubricating oil storage tank with removable sieves, useful volume – 20 000 litter.
Tank is welded of steel plate, is provided with inspection manholes, electrical oil heating system.
SC10B40 - 1x - Tank for non sealing oil, volume – 3000 Litter
The tank is welded of steel plate, is provided with necessary branches, sieves for the suction
side of the pumps, local level measuring instruments, level switches and designed for the
installation on the concrete floor.
SC10B50 – 1x – Tank for waste oil
SC10N31,N41 – 2x – Oil separator.
SC10Z00 – Necessary connecting piping, valves and local measuring devices.
SC11A01 – 1x – Main oil pump type Škoda with direct drive from the turbine shaft.
Capacity – 135 m3 / h, Pressure on delivery branch – 14 bar.
SC11Z00 - Necessary interconnecting piping and fittings.
SC12 - - System of Secondary ( HP regulating) oil.
- Primary oil transformer generating pressure of secondary oil.
- Non – uniformity meter
- Accelerator
- Speed / output changing device
- Pipings, local measuring devices, manostats
SC13- - System of starting oil
SC13A11, A21 – 2x – Starting oil Auxiliary pump.
- Centrifugal pump with electric motor output 150 kW, voltage 6000 v,
3
- Capacity – 200 m / h, Pressure on delivery branch – 13.7 bar
SC14- - System of Emergency Stop Oil.
- Main Relay
- Emergency Closing Relay
- Tripping Relay
- Pipings, local measuring devices, Manostats, Electro-magnets
SC15 - - Distribution Oil System
SC15H10 – 1x – Fine duplex filter,
3
Rated flow – 42 m / h, Pressure losses in clean filter – 0, 15 bar, Mesh size – 40 µm.
SC16 - - System of switch – over device.
- Transfer relay of the coupling of regulating of steam regulating valves, regulating flap valves in the
nd
2 extraction point and NR check Valves.
- Electro hydraulic converters, local measuring devices, electromagnet.
SC17A01 – 1x – Lubrication oil ejector,
Working medium – oil from the delivery side of the main oil pump or from auxiliary pumps,
Capacity – 135 m3 / h, Pressure after ejector – 4.0 bar.
SC17A11 – 1x – Lubricating oil auxiliary centrifugal pump with electric motor,
3
Output 20 kW, Voltage 380 V, Capacity – 150 m / h, pressure on delivery branch – 3, 4 bar.
SC17A21 – 1x – lubricating oil emergency centrifugal pump with electric motor,
3
output 7, 5 kW, voltage – 110 v DC, Capacity – 100 m /h, pressure on delivery branch – 2.3 bar
SC17B01, SC17B02- 2x – vertical design lubricating oil cooler,
2
Heat exchanger tubular surface – 180 m , cooling output 1008 kW, Rated quantity of cooling water
3
300 m /h, Rated temperature of cooling water – 40 0C, Pressure loss – 0,4 bar,

3
SC17N01 – 1x – Magnetic filter for building in piping, Rated flow rate – 160 1/min, Press. Loss 0, 07 bar, Mesh
size = 63 µm
SC17N02, 03, 04, 05 – 4x – Magnetic filter for building in the piping,
Rated flow rate- 250 1 / min, Press. Loss = 0, 07 bar, Mesh size = 250 µm
SC17N10, N20- 1x – Vertical design Fine duplex filter for oil,
Rated flow rate = 132 m3/h, Press. Loss in clean filter = 0.15 bar, Mesh size = 40 µm.
• The filter is delivered inclusive of shift – over valves.
SC17Z - -
SC18 - 2x - Shifting of lifting oil
SC18A21 - Gear pump with electric motor,
Output = 37 kW for voltage of 380 v, Capacity = 6,6 m3/h, Pressure on delivery branch = 160 bar
• The pump is equipped with a safety by pass valve.
SC18N10, N20 – x1- Vertical design fine duplex filter for oil,
Rated flow rate = 7, 2 m3/h, Press. Loss in clean filter = 0, 15 bar. Mesh size = 40 µm.
SC18Z –
SC19 - - System of primary oil
- Primary oil pressure source.
- Pipe distribution system, local measuring devices, manostats, electro magnets
SC22 - - Tertiary oil system.
- Oil transformer to generate pressure.
- Distribution pipes, local measuring devices.

SC25 - - System of LP regulating oil


- Pressure transformer.
- Distribution pipes.

SC26 - System of working and signaling oils.


- Main signaling relay.
- Distribution pipes, local measuring devices.

SC40 - - System of oil filling and cleaning.

SC41A11 – 1x – Oil purifier Alfa Level MAB203S – 20 , Capacity = 3000 l/h,


• The set is installed on a common frame and includes:
- A centrifugal separator with exchangeable disks in the purifying arrangement, with drive by
electric motor of 3 kW, 1500 RPM., Separator speed maximum = 8725 RPM.
- Booster pump suction capacity = 4 m W.C.
- Delivery head = 15 m W.C.
- Electrical oil heater type , output variable ----.
- Equipment of water seal.
- Control box.
- Inner tubing.

SC40Z -- -SC90Z

4
SD – CONDENSING PLANT

SD09 – Condenser Cleaning / Taprogge/ System consists of following parts:-


SD09A10- 2x- Ball dosing centrifugal type pumps with
Electric motors output = 3 kW, 380 v, Capacity = 60 t/h, press. In suction Part = 0,65 bar, press.
On delivery branch = 1.65 bar.
SD09B10, B20-2x – Rubberized ball storage bin. Size = 10, Total volume = 35 1, Rate of flow 60 t / h,
Design pressure = 6 bar.
SD09Z10, Z20- 2x – Ball separator double grate type with two actuating mechanisms . the separator is designed
for building in the vertical piping, the direction of flow from the top down, the structural length is
2000 mm. it is rubberized and intended for the flow rate of 16400 t/h.
GR01, 02 – 2x – Local control box including fitting to control the separator, pump, ball dosing to the circuit,
failure signaling to TCR -2. Feeding power = 8 kW, Dimensions = 2200 x 800 x 400.
SD10B10 – 1x – Surface condenser with a tubular heat – exchange surface in design for sea water, adapted to
the continual cleaning during operation and to the possibility of revision of it’s one half.
2
- Rated heat exchange surface - 8400 m
- Number of passes -1
- Number of tubes - 14112
- Tube outside diameter - 23 mm
- Number of tubes with wall thickness of 1.5 mm - 13148
- Number of tubes with wall thickness of 2.0 mm - 964
- Tube length - 8500 mm
0
- Rated temperature of circulating water - 32 C
- Average speed in tubes - 1.815 m/s
- Pressure loss in fouled condenser - 0. 240 bar

• Cathodic protection producer


- TV-GRILLO-AMPAK Anodes Fe / Si / Cr - 32 pcs of 50 kg each
- Reference zinc cells - 4 pcs
- Rectifier with voltage regulation - 10 v / 350 A
- Situated in a box of dimensions - 1600 x 800 x 500

• SD15A10, SD25A10 – 2x- Water jet air pump for evacuation the steam space of the turbine and of the
condenser
- Electric motor vacuum pump type 2BW4303 – OBL4 in a compact design
- Set capacity - 65 kg / h dry air
- Corresponding quantity of air and steam mixture - 230 kg / h
- Pressure in suction part - 0,025 up to 1 bar
• The Set consists of following parts:
- Ejector pump
3
- Capacity - 21 m / h
- Speed - 585 RPM

• Electric motor HXUR 638G5, output - 75 kW, 380 V


- Circulating pump
- Capacity - 23 m3 / h
- Separator of volume - 700 litter
- First – stage compressor
- Service water cooler
- Interconnecting pipes, fittings, local measuring devices, measuring instruments

• SD41A10 – 1x – Hogging ejector


Starting steam – jet ejector connected to the 13 bar system of RQ-20 auxiliary steam, intended
for the quick reaction of the turbine system during starting up.
- Minimum steam pressure - 9.8 bar
0
- Maximum steam temperature - 250 C

5
- Quantity of service steam -3t/h
- Quantity of sucked – off air - 1.2 t / h
- Rated pressure in suction part - 0.49 bar
- Minimum pressure in suction part - 0.2 bar

• SE - TURBINE REMOTE CONTROL SYSTEM


SE10A01 – Control of Speed / Output meter
SE10A10 – Control of limiting device

• SG - - System of Gland and lead tube – off tube steam.


SG01 - - Transfer of flooding steam
SG01Z - - Steam supply piping, fittings, necessary mountings.
SG10 - - Gland steam circuit
SG0z - - Connecting piping, fittings, mountings, pipe lines, local measuring devices
SG20 - - Circuit of exhausting from glands
SG30 - - System of exhausting the gland steam
SG30B10- 1x – Gland steam Condenser, cylindrical surface heat-exchanger with tubular heat exchanger
surface in a horizontal design.
2
- Rated heat exchange surface - 42.7 m
- Number of passes -1
- Number of tubes - 301
- Dimensions of tubes - 18 x 1.25 mm
- Dimensioning of steam side - 0 / 2.5 bar, 370 0C
0
- Dimensioning of water side - 31 bar, 70 C

• SG40- - System of lead – off tube steam


SG40B10 – 1x – Lead off tube steam condenser, cylindrical surface heat exchanger with tubular heat- exchange
surface in horizontal design.
2
- Rated heat exchange surface - 42.7 m
- Number of passes -1
- Number of tubes - 245
- Dimensions of tubes - 18 x 1.25 mm
0
- Dimensioning of steam side - 0 / 2.5 bar, 225 C
0
- Dimensioning of water side - 31 bar, 70 C

SG41, 42A10- 2x – Lead off tube steam fan / STK steam fan, radial flow centrifugal fan with electric motor,
output = 11 kW, 380 V,
0 3
- Delivered medium – steam – air mixture of = 70 C , 0.88 kg / m
- Delivered quantity = 910 m3 / h
- Static pressure = 1.458 bar
- Power input on shaft = 3. 14 kW

SG40Z - - Appertaining steam piping, fittings, hangers and safety valves.


SG50 - - System of exhausting the lead-off tube steam from the turbine glands
SG60- - System of exhausting from glands of valves, regulating and NR flap valves and from flange
heating through

6
• SH - - Turbine dewatering system.
SH1, SH9 - - Dewatering of extraction steam and NR flap valves.
SH10- - HP dewatering system, collecting piping for dewatering of:-
- Steam regulating valves.
- Heating – through pipings
- Return steam and HP cylinder
- Piping for flooding the gland steam system
• SH20 - - IP and LP dewater systems, collecting piping for dewatering of:-
- Steam regulating valves.
- Steam piping to the turbine
- Extraction pipings
- Flange heating – through system.
- Gland steam system.
• SH30 - - Expansion branches of the condenser.

VC - COOLING WATER (SEA) SYSTEM

• VC10A10 -1 x – Cooling (sea) water pump, Vertical single-stage tubular pump with mixed flow.

- Type: BVa 1800, Producer: Balcke- Ďurr ( FRG)
3
- Capacity - 33250 m / h
- Delivery head - 14 m W.C.
- Speed - 370 RPM.
- Pump power input - 1519 kW
0
- Max. temperature of medium - 35 C
3
- Sea water density - 1,03 t / m
- Max. Pressure at null quantity - 31 m W.C.
- Pump weight with out motor - approx. 35 ton.
• The thrust plain bearing is dripped in oil bath cooled with sea water from cooling and lubricating water
pump (78VC60/ 61A10). Radical bearings on a vertical shaft are lubricated and cooled with sea water
directly, also by means of the above mentioned pump 78VC60 / 61A10.

• ELECTRIC MOTOR: type HSUP 18 / 668, Producer: Strömberg

- Output (rated) - 1900 kW


- Voltage - 6000 V, 50 C / S
- Speed - 370 RPM
- Rated current - 233 A
- Power Factor - 0. 83
- Power input ( at rated load) - 1991 kW
- Motor weight - 19.5 ton.

• Antifriction bearings of the electric motor are lubricated by dripping in the oil bath ( the upper thrust bearing)
and / or by a permanent grease filling ( the lower radial bearing on the motor driving side).
• The electric motor is equipped with necessary measuring instruments and with a heating body of 1600 W,
220 V, 50 C / S prevented condensation.
• 78VC10A10 – 1x- Spare cooling (sea) water pump for units 7 & 8. The data ditto pump VC10A10.
• VC – Delivery piping of the cooling (sea) water pump including expansion bend.
• 78VC10- Delivery piping of the cooling (sea) water pump 78VC10A10, including expansion bend, piping .
• VC10G800 – 1x – combined closing NR butterfly valve with a hydraulic drive.
• 78VC10G800 – Gate valve at the delivery of the emergency pump 78VC10A10, data ditto VC10G800.
• 78VC11 – Delivery piping of reserve cooling sea water pump after fitting 78VC10G800 ( in the pumping
Station object),
• 78VC12 – Piping at the delivery of sea cooling water pumps – interconnection between pumps VC10A10
and 78VC10A10: including expansion bend of diameter 2200.

7
• 78VC12G200- 1x – closing fitting on interconnection pipe between pumps VC10A10 and 78VC10A10
(pipeline 78VC12).
• C11 - - pipeline at the delivery of cooling (sea) water pump VC10A10 (after combined valves VC10G800).
In the pumping station object, this pipe line is carried on 3 sliding supports. In the part between
the pumping stating and entrance to the engine room, the pipe line is led underground in sand
subsoil. ON this part pf the line , there are provided five inspection holes ( utilized also for the
installation of a portable pump, for exhausting the cooling sea water system) and a branch pipe
to water drain basin . In the engine room, the pipe line is led in a concrete channel on the floor at
-5.10 meter on 1 fast and 4 sliding supports. Three branch pipe lines (VC20, VC30 to the
condenser and VC40 to service water coolers) are brought out of this part of VC11 pipeline in the
engine room, and a drain piping.
• VC20 - - Supply and waste pipings to one half of the condenser.
• VC30 - - Supply and waste pipings to the other half of the condenser.
• Pipelines VC20, VC30 are inclusive of drain piping with a closing valve and a sieve and expansion bends at
the condenser inlet and outlet.
• VC20G200 -1x – Closing fitting at the condenser inlet on pipeline VC20,
• VC30G200 -1x - Closing fitting at the condenser inlet on pipeline VC30
• VC40 -- - Common supply piping to service water coolers,
• VC41B100 – drain and dewatering pipings and fittings
• VC42 - - Supply and waste pipings of cooler VC42B100. Drain and dewatering pipings.
• VC42 - - Supply and waste pipings of cooler VC42B100.
• VC41G200 – Closing fitting at the service water cooler inlet VC41B100.
• VC42G200 - Closing fitting at the service water cooler inlet VC42B100.
• VC41B100 – Cooler of service water, Horizontal heat exchanger with a tubular heat exchange surface.
3
 Quantity of cooling (sea) water = 3683 m / h
3
 Quantity of service water = 1105 m / h
 Heat output = 6630000 kcal / h
 Sea water max. temperature
0
(Inlet & outlet) = 35 / 36.8 C
 Service water max. temperature
(Inlet & outlet) = 46 / 40 0C
 Press. Loss (sea water side) = 2.8 m W.C.
 Press. Loss (service water side) =13.5 m W.C.
2
 Heat exchange surface ( total) = 507.2 m
 Main dimensions: dia. x length = 1300 x 8300 mm
 Number of tubes = 1300
 Dimensions of tubes = dia. 23 x 1.5 mm
• VC42B100 – service water cooler (reserve).
• VC41201 - - Closing fitting at outlet of service water cooler VC41B100
• VC42G201 - Closing fitting at outlet of service water cooler VC42B100.
• VC49 - - Common w3aste piping from service water coolers leading into VC50.
• VC50 - - Common waste piping from the condenser to the siphon trap.
• Note: - All cooling sea waste pipings are coated with polyamide epoxy resin on either side-
for the precise description of transport coat, laying in the channel and / underground see
the Specifications of Voest Alpine.

8
• VG – SERVICE WATER SYSTEM

VG10B01 – 1x –Expansion vessel. Vertical welded cylindrical vessel with built in overflow safety device as
protection against overpressure.
- Vessel height = 2.8 m
- Vessel diameter = 1.1 m
3
- Total volume = 2.5 m
- Weight without water = 923 kP
(Inner protective coat is resisting to demineralized water)
• Overpressure of 1.2 bar abs, in the expansion vessel is held by N2 supplied from a pressure bottle.
• The vessel is outfitted with necessary measuring instruments, an inspection manhole and branches for
connecting the pipings of service water, demineralized water (and/or condensate) and N2 nitrogen.
• VG10A10, A20 -1x – Horizontal single stage centrifugal Service water pump 1 & 2. Type TW 400/ 600,
3
- Capacity = 1105 m / h
- Delivery head = 50 m W.C.
- Speed = 985 RPM.
- Pump power input = 232 kW
- Delivery head at null delivery quantity = 57 m W.C.
• The pump is installed on a common frame with electric motor
- Rated output = 260 kW
- Voltage = 6000 v, 50 C / S.
- Speed = 985 RPM
- Rated current = 36 A
- Power factor = 0.74
- Power input ( at rated load) = 276 kW.

• VG10N10N20 – Filters in service water pumps VG10A10 & A20 suction, vertical welded cylindrical vessel
with five removable sieves of cylindrical shape ( dia. 230 x 992 mm).

- Vessel height = approx. 2000 mm


- Vessel diameter = 800 mm

 The filter is equipped with a filter fouling signaling device to the control room and with a local indicator
of presser loss, drain and deaerating pipings with fittings.
 The service water system consists of five separate parallel branches. The flow in every branch is
controlled by a regulating valve with pneumatic drive operated by the pressure difference at the
branch inlet and outlet. All five branches are joined to a single common collecting pipe in the suction
part of service water pumps.


• RA – HP STEAM PIPING SYSTEM

 RA – System of Super heated steam


 RA-10 – Single branch superheated steam line dimensioned for Parameters 138 bar, 520 0C .
 RA11, 12 – double branches part superheated steam lines
 RA11,12Z001 – 2x, HP steam separator with screen, forged adapting piece with a horizontal inlet
branch and vertical outlet branch.
 The separator is equipped with a mud collector for draining and heating the piping and with a
connection for the wet conservation.
 RA 13 – HP steam piping heating up line
 RA 20 - Piping to HP BY PASSES
 RA30, RA40 – 2x- HP By pass stations for parameters:
- Admission steam quantity = 330 t / h
0
- Calculated admission steam temperature = 525 C
- Calculated outlet steam pressure = 49 bar
0
- Calculated outlet steam temperature = 420 C

9
- Calculated pressure of injection water = 120 bar
0
- Temperature of injection water = 180 C

• RA41A10- 2x – HP by passes Hydraulic oil pumping set type HS16 – 20

- Storage tank - volume = 75 litter


- Axial flow piston pump
- delivered quantity = 15 l / min.
- Maximum working pressure = 180 bar
- Speed = 1500 RPM
- Electric motor speed = 1500 RPM
- Power = 5.5 kW
- Voltage = 380 v, 50 C / S.

• RA31,41G100 – 2x – Direct acting by pass valve


• RA31, RA41G101 – 2x- Pressure governor
• RA31,Ra41G102 – 2x- by pass valve
• RA31,RA41B11- 2x – Hydro-pneumatic accumulator
• Nitrogen space volume – 18 l
• GY50 – Control box

• RB – HOT REWHEAT STEAM SYSTEM


0
• RB10 – Single branch reheated steam line , pressure = 40 bar, temperature = 520 C
0
• RB11, 12 – Double branch part of reheated steam line , pressure = 40 bar, temperature = 520 C
• RB11, RB12Z001-2x – IP turbine separator with screen.
- The separator body is welded of two pressed hemispherical parts. A removable cylindrical
screen is built inside the separator.
- Body dimension body diameter = 1200 mm
- The separator is provided with a branch for draining and heating the piping. The separator
is delivered together with accessories for chemical boiling out and blowing through.
• RB13, RB14 – Heating piping of steam supply line to LP by Passes.
• RB15 - - Reheating Steam supply piping to step-down station RQ10 ( Feed water tank)
• RB16 - - Reheating Heating piping for step down station RQ 10.
• RB 20 - - Reheating steam piping for desalination plant.
• RB21,RB22 – Reheating steam piping to LP By Passes
• RB30, RB40- 2x – LP BY PASS Station Control for parameters:
- Admission steam quantity = 380 t / h
- Calculated inlet pressure = 49 bar
0
- Calculated inlet temperature = 525 C
0
- Calculated outlet temperature = 120 C
- Calculated outlet pressure = 2.0 bar
- Calculated pressure of injection water = 30 bar
0
- Maximum temperature of injection water = 100 C

• RB31, 41A10- 2x – LP By Passes hydraulic oil pumping set


- Storage tank volume = 75 litter
- Suction filter type = UC – SE – 1320
- Axial flow piston pump = type PAF-R-K-B
- Delivered quantity = 15 l / min.
- Maximum working pressure = 180 bar
- Speed = 1500 RPM
- Power = 5.5 kW
- Voltage = 380 V, 50 C/S.

10
• RB31,RB41G100 -2x- Direct – acting by pass valve
• RB31,RB41G101 -2x – Pressure governor
• RB31B11,RB41B11-2x- Hydro-pneumatic accumulator
- Nitrogen space volume = 18 l
- Maximum working pressure = 210 bar
- GY51 - Control Box of Local automatics

• RB35, RB45 – Gland steam piping from spindles of LP By Passes.

• RC – COLD REHEAT STEAM SYSTEM

• RC01, RC02 – Double branch part of cold reheat steam line , pressure = 46 bar, temperature = 420 0C .
- The steam line is provided with necessary adapting pieces.
• RC05 – - HP turbine outlet Cold reheating by pass of NRV flap valve
• RC05G411- - Temperature gradient control valve with electric driven intended for heating HP turbine
casing.
0
• RC 10 - - Single branch part of cold heat steam line, pressure = 46 bar, temperature = 420 C.
- The steam line is provided with necessary adapting pieces.
0
• RC11 - - Supply piping for flooding the turbine glands, pressure = 46 bar, temperature = 420 C
0
• RC12 - - Supply piping for flooding the IP turbine check valves, pressure = 46 bar, temp. = 420 C
0
• RC20 - - Piping for steam extraction from CRH steam system, press. =46 bar, temp.= 420 C
0
• RC21 - - CRH steam piping for step-down station RQ20, Press. =46 bar, temp.= 420 C
• RC22 - - CRH steam piping for alternate (in absence of turbine) heating of the HPH NO. 2 , equipped
with NRV , a motor operated closing valve
• RC24 - - Heating up piping for step down station – RQ20
• RC25 - - CRH steam supply piping for heating steam for HPH no. 2
• RC30 - - Single branch part piping from HP by Passes outlet
• RC31 - - Outlet steam piping from HP by Pass RA30
• RC32 - - Outlet steam piping from HP by Pass RA40

th
• RF10 - - Heating steam piping from the turbine 4 extraction point to HPH NO.1,
0
Press. 22 bar, temp. 425 C
• RF10B10- - HP heater No. 1 of feed water, heating with extracted steam from the IP turbine casing.

 Vertical exchanger with tubular heat exchange surface.
- Number of tube ------------------------------ = 1120
- dimension of tubes = dia. 16 x 2 mm
2
- total heat exchange surface = 712 m
2
- effective de-superheating zone = 112.6 m
2
- effective condensing surface = 464.7 m
- effective sub-cooling surface = 87.4 m2
- heat output = 26.6 MW
- pressure loss at MCR = 0.486 bar.
0
- dimension of steam side = 22 bar, 425 C temp.
0
- dimension of water side = 242 bar, 240 C temp.
3
- steam space volume = 8.9 m
3
- tubular part volume = 2.4 m

• RF20B10- - HP heater No. 2 of feed water, heating with steam from outlet of HP turbine casing.

 Vertical exchanger with tubular heat exchange surface.


- Number of tube ------------------------------ = 1172
- dimension of tubes = dia. 16 x 2 mm

11
2
- total heat exchange surface = 781 m
2
- effective de-superheating zone = 118 m
2
- effective condensing surface = 536 m
2
- effective sub-cooling surface = 60 m
- heat output = 29.97 MW
- pressure loss at MCR = 0.466 bar.
0
- dimension of steam side = 53 bar, 425 C temp.
0
- dimension of water side = 242 bar, 240 C temp.
3
- steam space volume = 8.3 m
3
- tubular part volume = 2.5 m

 RG – DRAIN AND DISCHARGE PIPING SYSTEM

 RH – EXTRACTION STEAM PIPING AND LP HEATERS

• RH10- - heating steam piping from the turbine first extraction point to the LP heater NO.1,
0
Press. = 2.71 bar, temp.= 294 C.
st
• RH10B10- LP heater no. 1 of turbine condensate, heated with extraction steam from turbine 1 extraction
point.
 Vertical exchanger with tubular heat exchange surface.
- number of U tubes = 707
- dimension of tubes = dia 16 x 1.25 mm
2
- total heat exchange surface = 476 m
- effective de-DE superheating zone =-
- effective condensing surface = 409 m2
- effective sub-cooling surface =0
- heat output =
- pressure loss at MR = 0.072 bar.
0
- dimension of steam side = 2.71 bar, 235 C temp.
0
- dimension of water side = 30 bar, 125 C temp.
3
- steam space volume = 6.5 m
3
- tubular part volume = 2.7 m
nd
• RH20B10- LP heater no.2 of turbine condensate, heated with extraction steam from turbine 2 extraction
point.
 Vertical exchanger with tubular heat exchange surface.
- number of U tubes = 617
- dimension of tubes = dia 16 x 1.25 mm
2
- total heat exchange surface = 422 m
- effective de-DE superheating zone =-
- effective condensing surface = 330 m2
2
- effective sub-cooling surface = 33 m
- heat output = 27 MW
- pressure loss at MR = 0.095 bar.
0
- dimension of steam side = 16.5 bar, 355 C temp.
0
- dimension of water side = 30 bar, 170 C temp.
3
- steam space volume = 5.6 m
3
- tubular part volume = 2.25 m
st
• RH20B11 – Expansion pipe for expansion of condensate from the 1 HP heater.
nd 0
• RH21 - - Steam piping from turbine 2 extraction point to the desalination, press. =10 bar, temp.=450 C
The piping equipped a NRV flap with electrical driven
nd
• RH22 - - steam piping from the turbine 2 extraction point to the safety valve, press. 10 bar, temp.=
0
400 C
- The piping equipped with an impulse safety valve, opening press= 9.50 bar, capacity = 76.7
t/h,

12
nd
• RH23 - - Steam piping from turbine 2 extraction point to the safety diaphragm, press. = 10.0 bar,
temp.= 400 0C.
-The piping is equipped with safety head SKQ with breaking disk NB600, rated breaking
pressure of 13.10 bar, capacity = 590 t / h with an exhaust branch extension.
rd
• RH30- - Steam piping from the turbine 3 extraction point to the feed water deaerator, press. = 13 bar,
0
temp.= 400 C.
- The piping is equipped with an electrical valve and a NRV

• RJ – Deaeration of main condensate line and drain piping

• RJ01-RJ04, - Piping for deaeration of the main condensate line and drain piping

• RL – FEED WATER PIPING SYSTEM, FW TANK AND FW PUMPING STATION

• RL01B10 - - Feed Water Tank with Deaerator, Horizontal cylindrical tank with a built in deaerator of the
Stork system

- Tank length = approx. 25050mm


- tank diameter = 4000 mm
3
- total volume = 306 m
- working volume = 245 m3
0
- dimensioning = 17 bar, 205 C / vacuum
• Deaeration equipment for the atomization and heating of inlet condensate by saturated steam
generated in the water space of the tank.
- rated output = 600 t / h
- maximum output =
0
- maximum heating to = 98 C
0
- minimum heating to = 15 C
- pressure loss at inlet = 0.6 bar – constant
- 02 content at deaerator outlet = 0.02 mg / kg.

• The tank is seated on two steel bases of which one is stationary and the other sliding.
• the tank is outfitted with local measuring instruments and two safety valves: -
- RL01G104, RL01G105, opening pressure = 13.5 bar, Capacity = 50 t /h

• RL 01G106 – Vacuum remover, Opening pressure = approx. 0.9 bar.


• RL02 - - Magnetic filter system
• RL02A10- - Centrifugal Pump with an electric motor for recirculating the FW tank content.
- Power = 2.2 Kw, 380 V
3
- Delivery quantity = 30 m / h
- Boost of pressure by means of pump = 1.3 bar.
- Speed = 1450 RPM
- Pump cooling = 8. l /min. by service water

 RL 10 – FEED SET NO. 1 WITH ACCESSORIES

• RL10X01 - Noise – damping cover of the set


• RL10X010 – Noise damping cover for the3c HP pump and hydraulic gear box.
The cover is assembled of steel sheet. The noise reduction is ensured with the filling of mineral
wool with the high noise absorptivity.
The cover is provided with admissions to the3 face of the HP pump and to the hydraulic gear
box and with a fan for force ventilation.

13
• RL11 - - Suction piping of feeding set
- The piping is equipped with two hand operated closing valve.
• RL11A10- - Booster pump for boiler single-stage centrifugal feed pump.
3
- delivered quantity = 507 m / h
- pressure increase = 3.57 bare
- speed = 1490 RPM
0
- maximum temperature of medium = 180 C
• RL11Z001 – Coarse screen built in the suction part of the booster pump
• RL12 - - Transfer piping between the delivery side of the booster pump and suction side of the high-
pressure boiler feed pump.
• RL- - Heating piping of feed pump.
• RL12A10 - High pressure FW pump of the boiler in the barrel design
- A high – speed five stage centrifugal pump
- Type TSH - T – 150 – 5 = ( Balcke Dürr)
3
- Deliver quantity = 475 m / h
- Delivery Head = 1967 m L.C.
- Maximum speed = 5387 RPM
0
- Maximum temperature of medium = 180 C
- Max. press. On delivery branch/quantity = 193 bar, 410 t / h
- Max. pressure at null quantity = 242 bar
st st
- 1 intermediate extraction after the 1 stage = 55 t / h
nd nd
- 2 intermediate extraction after the 2 stage = 55 t / h
- Closing pressure of the 1st intermediate extraction = 56 bar
nd
- Closing pressure of the 2 intermediate extraction = 110 bar

• RL12B20,B30 –Gland water cooler


3
- Heat exchange surface = 0.13 m
- Heat output = 10 kW
3
- press. Loss at cooling water flow rate of 0.5 m / h = 0.1 bar

• RL13A01 - - Pre- lubricating gear type pump with electric motor


- Power = ----- kW, 380 V

• RL13B10 - - Regulating oil cooler


- Horizontal exchanger with tubular heat exchange surface.
- Number of tubes = 320
- Dimension of the tubes = dia. 10 x 0.8 mm
2
- Total heat exchange surface = 17.5 m
- heat output = 556 kW
3
- press. Loss at cooling water flow rate of 16.5 m / h = 0.35 bar

• RL30B10 - - Lubricating oil cooler


- Horizontal exchanger with tubular heat exchange surface.
- Number of tubes = 65
- Dimension of the tubes = dia. 10 x 0.8 mm
2
- Total heat exchange surface = 3.7 m
- heat output = 50 kW
3
- press. Loss at cooling water flow rate of 16.5 m / h = 0.25 bar

• RL13 - - Lubricating oil duplex filter type SV with a magnetic element and change-over valve.
- the filter is equipped with a signaling device when filter fouling at ∆P = 0.6 bar

• RL13A - Hand operated pump for discharging the oil tank of the hydraulic gear box.
• EL14A10 - - Electric motor of feeding set with accessories
- Power = 3650 kW
- Voltage = 6000 V
- Speed = 1484 RPM

14
- Rated current = 415 A
• The electric motor is provided with pressure oil lubrication.
• RL14B10 - - Electric motor Cooler
3
- Cooling water quantity = 21 m / h
- Pressure loss = 0.2 bar
- Heat output = 135 kW
• RL15 - - Piping of the first intermediate extraction inclusive of NRV and an electrical valve.
• RL16 - - Piping of the first intermediate extraction inclusive of NRV and an electrical valve.
• RL18 - - Equipment of the minimum rate of flow.
• RL18G211- - Multistage throttle valve with electric drive.
- Rate of flow = 65 t / h
- Differential pressure = 205 bar.
• The valve is controlled by the difference of the rate of flow by means of nozzle RL12F01 and
orifice plates RL15F01 and RL16F01.
• RL18Z001- - A remotely hand operated electrical valve is a part of the by pass valve RL18G211.
• RL19 - - Delivery piping of feed pump.
- The piping is equipped with accessories, a NRV with extraction for the minimum rate of
flow, an electrical valve , an electrical by pass valve and local measuring instruments.

• RL20 - - FEEDING SET NO.2 WITH ACCESSORIES

• RL20X01 - Noise – damping cover of the set


• RL20X010 – Noise damping cover for the3c HP pump and hydraulic gear box.
The cover is assembled of steel sheet. The noise reduction is ensured with the filling of mineral
wool with the high noise absorptive.
The cover is provided with admissions to the3 face of the HP pump and to the hydraulic gear
box and with a fan for force ventilation.

• RL21 - - Suction piping of feeding set


- The piping is equipped with two hand operated closing valve.
• RL11A10- - Booster pump for boiler single-stage centrifugal feed pump.
3
- delivered quantity = 507 m / h
- Pressure increase = 3.57 bare
- Speed = 1490 RPM
0
- Maximum temperature of medium = 180 C
• RL21Z001 – Coarse screen built in the suction part of the booster pump
• RL22 - - Transfer piping between the delivery side of the booster pump and suction side of the high-
pressure boiler feed pump.
• RL- - Heating piping of feed pump.
• RL22A10 - High pressure FW pump of the boiler in the barrel design
- A high – speed five stage centrifugal pump
- Type TSH - T – 150 – 5 = ( Balcke Dürr)
3
- Deliver quantity = 475 m / h
- Delivery Head = 1967 m L.C.
- Maximum speed = 5387 RPM
- Maximum temperature of medium = 180 0C
- Max. press. On delivery branch/quantity = 193 bar, 410 t / h
- Max. pressure at null quantity = 242 bar
st st
- 1 intermediate extraction after the 1 stage = 55 t / h
nd nd
- 2 intermediate extraction after the 2 stage = 55 t / h
st
- Closing pressure of the 1 intermediate extraction = 56 bar
nd
- Closing pressure of the 2 intermediate extraction = 118 bar

• RL22B20,B30 –Gland water cooler


3
- Heat exchange surface = 0.13 m
- Heat output = 10 kW
3
- Press. Loss at cooling water flow rate of 0.5 m / h = 0.1 bar

15
• RL23A01 - - Pre- lubricating gear type pump with electric motor
- Power = ----- kW, 380 V

• RL23B10 - - Regulating oil cooler


- Horizontal exchanger with tubular heat exchange surface.
- Number of tubes = 320
- Dimension of the tubes = dia. 10 x 0.8 mm
- Total heat exchange surface = 17.5 m2
- heat output = 556 kW
3
- Press. Loss at cooling water flow rate of 16.5 m / h = 0.35 bar

• RL23B20 - - Lubricating oil cooler


- Horizontal exchanger with tubular heat exchange surface.
- Number of tubes = 65
- Dimension of the tubes = dia. 10 x 0.8 mm
2
- Total heat exchange surface = 3.7 m
- heat output = 50 kW
3
- Press. Loss at cooling water flow rate of 16.5 m / h = 0.25 bar

• RL23 - - Lubricating oil duplex filter type SV with a magnetic element and change-over valve.
- the filter is equipped with a signaling device when filter fouling at ∆P = 0.6 bar

• RL23A - Hand operated pump for discharging the oil tank of the hydraulic gear box.
• EL24A10 - - Electric motor of feeding set with accessories
- Power = 3650 kW
- Voltage = 6000 V
- Speed = 1484 RPM
- Rated current = 415 A
• The electric motor is provided with pressure oil lubrication.
• RL24B10 - - Electric motor Cooler
3
- Cooling water quantity = 21 m / h
- Pressure loss = 0.2 bar
- Heat output = 135 kW
• RL25 - - Piping of the first intermediate extraction inclusive of NRV and an electrical valve.
• RL26 - - Piping of the first intermediate extraction inclusive of NRV and an electrical valve.
• RL28 - - Equipment of the minimum rate of flow.
• RL28G211- - Multistage throttle valve with electric drive.
- Rate of flow = 65 t / h
- Differential pressure = 205 bar.
• The valve is controlled by the difference of the rate of flow by means of nozzle RL12F01 and
orifice plates RL15F01 and RL16F01.
• RL28Z001- - A remotely hand operated electrical valve is a part of the by pass valve RL18G211.
• RL29 - - Delivery piping of feed pump.
- The piping is equipped with accessories, a NRV with extraction for the minimum rate of
flow, an electrical valve , an electrical by pass valve and local measuring instruments.

RL30 - - FEEDING SET NO. 3 WITH ACCESSORIES

• RL30, The specified scope is the same as mentioned sets 1 or 2.

• RL40 - - FW piping to HP heater, Pressure = 250 bar, temp. = 200 0C


• RL41 - - Piping from the change-over valve to the high pressure heater , Pressure=250 bar,
0
temp.=2000 C
nd 0
• RL43 - - Feed Water piping from 2 HP heater to the angle NRV , press.= 250 bar, temp.=200 C
• RL44 - - Impulse piping of change-over valves.

16
• RL45 - - By pass piping of HP heater.
• RL45G801, 802– Set of change over valves with impulse controlling by the FW pressure.
• RL50 - - FW piping from the change-over valves to the feeding head of the boiler.
0
• RL70 - - Injection water piping for the reheater and HP by passes. 110 bars temp. = 200 C
• RL80 - - Injection water piping for the desalination and step-down station, press.60 bar,
0
temp.=200 C

RM - SYSTEM OF TURBINE CONDENSATE

• RM - - Suction piping of LP condensate pumps.


• RM00Z010, 011- Conical screen built in the horizontal piping. For the time of the first starting, the screen is
protected by means of a wire netting. The piping is equipped with pressure difference
measuring devices.
• RM01-04A10- 4x – LP Condensate pump type MOkav200 -3, A three-stage vertical centrifugal pump with a
suction vessel.
• Delivery quantity - = 270 t / h.
• Delivery head - = 80 m W.C.
• NPSH - = 2.2 m W.C.
- The pumps are situated on a common frame and each of them is derived by an electric
motor with power of 90 kW, 380 v, 1000 RPM.
• RM04 - - Delivery piping of LP condensate pumps inclusive of inlet to CCP, outlet and by pass of
CCP.
- The piping is equipped with electrical valves and local measuring instruments.
• RM05 - - Suction piping of booster pumps.
• RM05-08A10 – 4x – Single stage centrifugal horizontal Condensate Booster pump.
- Delivery quantity = 270 t / h
- Delivery head = 170 m W.C.
- NPSH = 8.5 m W.C.
The pump is situated on a common frame with electric motor of power=225 kW, 6000 V,
2970 RPM.
• RM09 - - Condensate piping from the Cold Condensate Storage tank to Condenser.
- The piping is equipped with accessories, valves and regulating valve.
• RM09B10 - - Vertical cylindrical Cold Condensates Storage tank.
- Rated volume = 300 m3
- Dimensions = dia. 5000 x 18500 (15160) mm
0
- Dimension of upper part = 3.5 bar / 0.2 bar, 275 C
- The tank is equipped with a cylindrical pedestal, anchor bolts, necessary branches, inlets
and local measuring instruments.
• RM10 - - Delivery piping condensate Booster pumps.
- The piping is equipped with necessary accessories, closing measuring valves, electrical
valves, and local measuring instruments.
• RM11 - - Piping of the minimum rate of flow of condensate pumps.
• RM12-RM18 - - Distribution system of Low Pressure injection water.
• RM19 - - Condensate discharge piping to the storage tank of Cold Condensate
st nd
• RM20 - - Turbine Condensate piping between the 1 LP heater and 2 LP heater
nd
• RM30 - - Turbine Condensate pumping from the 2 LP heater to the FW deaerator
• RM40B10 - - Vertical cylindrical Equalizing storage tank intended for suspension on the steel structure.
3
- Rated volume = 3.5 m
- Dimensions = dia. 1200 x 3688 mm
0
- Dimensioning for parameters = 1.775 bar / 0 bar, temp. 100 C
- The tank is equipped with necessary built –in system, branches, inlet and suspension pull
rods.

17
• RN HEATING STEAM CONDENSATE SYSTEM
st
• RN - Condensate discharge piping from the 1 LP heater, piping dimensions = dia 219 x 6 mm
- The piping is equipped with hand operated valves with the flooded gland, a pneumatic regulating
valve and accessories.
• RN10B10 – A Cylindrical surface exchanger with a tubular heat exchange surface in horizontal design
Condensate water cooler for the 1st LP heater.
2
- Rated heat exchange surface = 128 .3 m
-
Number of passes =2
- Number of U tubes = 1296
- Dimension of U tubes = 16 x 1.25 mm
- Heat output = 6.02 MW
- Pressure loss at MR
- Content Shell space = 0.87 m3
3
- Content of tube space = 0.90 m

st
• RN1 - - Condensate discharge piping from the 1 LP heater.
• RN20 - - Condensate discharge piping from the 2nd LP heater to the 1st LP heater. The piping is equipped
with accessories, a pneumatic regulating valve and hand operated closing valves.
nd
• RN21 - - Condensate discharge piping from the 2 LP heater to condenser . The piping is equipped with
necessary accessories, a pneumatic regulating valve and a hand operated closing valve.
st
• RN23 - - Return condensate piping from the 1 desalination unit. The piping is equipped with necessary
accessories and a NRV.
nd
• RN24 - - Return condensate piping from the 2 desalination unit with a branch to the condenser. The
piping is equipped with necessary accessories, a NRV, an electrical valve, a hand operated
valve and a limiting orifice plate.
• RN25 - - Return condensate piping from the desalination unit to deaerator. The piping is equipped with
necessary accessories, an electrical valve.
• RN29 - - Branch pipe from the return condensate piping for deaerating the service water system.
• RN30 - - Collector for drains at the condenser, dia. 1016 x 12 mm.

• RP - - HEATING STEAM CONDENSATE SYSTEM FOR HP REGENERATION.


st
RP10 - - Condensate piping from the 1 HP heater to feed tank . The piping is equipped with
necessary accessories, a NRV, hand operated closing valves, a pneumatic regulating valve
and an electrically controlled by pass.
st nd
• RP11 - - Condensate piping from the 1 HP heater to the 2 LP heater. The piping is equipped with
necessary accessories; hand operated closing valves and pneumatic regulating valve.
st
• RP12 - - Condensate piping from the 1 HP heater to Condenser. The piping is equipped with
necessary accessories; hand operated closing valves, a pneumatic regulating valve and
deaeration for the event of operation with the isolated turbine.
nd st
• RP20 - - Condensate piping from the 2 HP heater to the 1 HP heater. The piping is equipped with
necessary accessories, hand operated closing valves, a pneumatic regulating valve, a hand
operated regulating by-pass valve and deaeration for the event of the operation with the
isolated turbine.
nd
• RP21 - - Condensate piping from the 2 HP heater to the condenser. The piping is equipped with
necessary accessories, a hand operated closing valve, a pneumatic regulating valve and
deaeration for the event of the operation with the isolated turbine.
nd
• RP22 - - Condensate piping from the 2 HP heater to the feed tank. For the operation with the isolated
turbine. The piping is equipped with necessary accessories, a NRV; a hand operated closing
valve and a pneumatic regulating valve.

18
• RQ - - AUXILIARY STEAM SYSTEM
• RQ10 - - Distribution piping of auxiliary steam of 3.5 bar for the deaerator.

• RQ10G491- Pressure and temperature step down station for emergency heating of the deaerator supplied
with hot reheated steam.
- Hot reheated steam = 30 bar
- Admission pressure = 3.5 bar
- Outlet pressure = 3.5 bar
0
- Admission temperature = 515 C
- Outlet temperature = 300 0C
- Outlet quantity = 70 t / h
- Seat diameter = 155 mm
- Kv min. = 11.2
- KV max. = 280.7
The step down station is equipped with a distributor, heating through system, necessary
valves, by-pass and local measuring instruments.

• RQ20 - - Distribution piping of auxiliary steam of 13 bar, 200 0C including secondary distributors in the
scope as per the flow diagram 3970 VS2471 R003.
• RQ20G491- Pressure and temperature step down station for the auxiliary steam system, supplied with
steam from the cold reheat.
- Admission pressure = 34 bar
- outlet pressure = 13 bar
0
- admission temperature = 330 C
0
- outlet temperature = 200 C
- outlet quantity = 40 t / h
- seat diameter =110 mm
- Kv min. = 59
- Kv max. = 206
- The step down station is equipped with a distributor, heating through system, necessary
valves, remotely controlled by pass and local measuring instruments.

• RQ30 - - Distribution piping of auxiliary steam for the steam cushion of cold condensate storage tank
• RQ30G491 - - Pressure and temperature step down station for the steam cushion of the cold condensate
storage tank. Supplied with steam from the 3rd extraction point of the turbine.
- admission pressure = 6.2 bar.
- outlet pressure = 1.1 bar
0
- admission temperature = 304 C
0
- outlet temperature = 120 C
- outlet quantity =2t/h
- seat diameter = 65 mm
- The step-down station is equipped with a by pass and necessary valves.

• RR - - EXHAUST PIPING OF SAFETY VALVES including mountings, and drains.

• RS - - DEAERATING PIPINGS including mountings, and valves

• RT - - CLEAN DRAINAGE SYSTEM

• RT10, 20A10 – 2x – Horizontal centrifugal Clean drain pumps, Power = 37 kW, 380 V, 1450 RPM.
3
- Delivery quantity = 30 m
- Pressure increase = 16.35 bar
0
- Max. Temperature of delivered Medium = 100 C
- NPSH = 1.6 m

19
• RT11A10 - - CLEAN DRAINAGEAUXILIARY PUMP
- Single stage horizontal centrifugal pump with electric motor, Power = 1.5 kW, 380 V, 1450
RPM.
3
- Deliver quantity = 20 m
- Pressure increase = 0.8 bar
0
- Max. temperature of delivery medium = 100 C
- NPSH = 1.5 m

• RT11B10 - - CLEAN DRAIN FLASH TANK


- Vertical cylindrical vessel. The tank is equipped with built in system to prevent the
showering effect.
3
- Rated volume = 6.3 m
- Design pressure = 1.5 bar
- Design temperature =
- The tank is seated on three bases and equipped with branches, inspection manhole and
local measuring instruments.

• RT12B10- - CLEAN DRAIN TANK


- Cylindrical horizontal tank based on the installation on a concrete structure.
3
- Useful capacity = 20 m
- Design pressure = 1.3 bar.
0
- Design temperature = 100 C
- The tank is equipped with necessary built in system, overflow, branches and local
measuring instrument. The pipings in suction and delivery parts of pumps, pipings from the
system ORT to the condenser collector, storage tank inclusive of hand operated as well as
electrically operated closing valves.

• RU - - WASTE DRAIN SYSTEM

• RU50,60A10- 2X –Vertical centrifugal Mud pump with electrical motor, Power = 380 V,
3
- Delivery quantity =5m /h
- Necessary pipings of for mud pumps including valves.

• RT12B10- - CLEAN DRAIN TANK


• RX - - SEAL WATER SYSTEM.
- Necessary piping and valves arranged in circuits for the flooding of single groups of
vacuum valves.
• RX02 - - Step down station of seal water station connected to the delivery sides of low pressure
condensate pumps.
- Operating pressure = 3 bar
- Max. Pressure = 4 bar.
3
- Rate of flow =5m /h

• RY - - Unclean drain system.


- Necessary pipings and valves for draining the water spaces of equipment and pipings to
the waste drain basin.

• RZ - - Clean drain system .


- Necessary pipings and valves for discharging and draining the equipment and pipings
to the clean drain tank