THIS DRAWING IS THE PROPERTY OF

06 530 125
PUMP DUTIES
JAKSON & COMPANY AND MUST
NOT BE USED OR COPIED WITHOUT CAPACITY 137 m3/h EFFICIENCY 67.56 %
THEIR AUTHORITY IN WRITING
TOTAL HEAD 120 m PUMP INPUT 66.19 KW
DENSITY 998.6 Kg/m3 NPSHR 3.00 m
315
FLANGE DRILLING STANDARD AND DETAILS
SUCTION BS EN1092 PN 16 FF DELIVERY BS EN1092 PN 16 FF
NOM. SIZE RF DIA P.C.D. NO FO HOLES HOLE SIZE
SUCTION 125 mm N.A. 210 mm 8 18.00 mm
250 250 DELIVERY 80 mm N.A. 160 mm 8 18.00 mm

ALLOWABLE NOZZLE LOADING


141 141 FORCES MOMENTS
Fx Fy Fz Mx My Mz
SUCTION 114.0Kgf 284.0Kgf 227.0Kgf
DELIVERY 91.00Kgf 227.0Kgf 182.0Kgf
TAPPING DETAILS
DESCRIPITION SIZE / TYPE
SUCTION GAUGE 1/4" BSP
FRONT VIEW SECTION II - II DELIVERY GAUGE 1/4" BSP
CASING DRAIN 3/8" BSP
CASING VENT NA
BEARING COOLING IN/OUT NA
65 PAD COOLING IN/OUT NA
STUFFING BOX COOLING IN/OUT NA
200 BASE DRAIN NA
GL 300
COOLING WATER REQUIREMENT
590
655
960

150 FLOW NA
Foundation bolt qty ;06 nos.
Bolt SIZE ;M 16 , Length-250 MM PRESSURE NA
VIEW AT X-X
ADDITIONAL DATA
STATIC LOAD 642.5 Kg. DYNAMIC LOAD 802.1 Kg
GD^2 OF PUMP 0.33 Kg.m2
665 665 BASE TYPE STANDARD BASE MATERIAL MS
1460 COUPLING TYPE PIN BUSH GUARD MATERIAL MS
1680
COUPLING SIZE RB-178 F BOLT MATERIAL MS
PLAN
DIRECTION OF ROTATION FROM DE CLOCK WISE

PUMP CPHM 80/32 PUMP WT. 133.00 Kg.


DRIVER MAKE KIRLOSKAR DRIVER WT. 390.00 Kg.
DRIVER RATING 75 KW BASE WT. 110.6 Kg.
DRIVER SIZE 250 M COUPLING WT. 8.83 Kg.
RATED SPEED 2965 RPM PUMP SET WT. 642.5 Kg.
SHAFT END DETAILS ENQ. NO./ DATE / QUANTITY 1
D X Y L
PO. NO. / DATE - TAG NO. DEFAULT
PUMP 42.00 12.00 45.00 110
MOTOR 60.00 18.00 64.00 140 QUOTATION NO. -1 DATE -
O/A NO. - MISI -
CUSTOMER -
1) ALL DIMENSIONS ARE IN mm. DIMENSIONS WITHOUT TOLERANCE FOR WELDED END USER -
PARTS ARE AS PER ISO13920-D PROJECT -
2) GROUTING TO BE DONE UP TO LEVEL Y TO AVOID VIBRATIONNS. CONTRACTOR -
3) CIVIL ENGINEERING DETAIL1*1 SHOWN ARE TENTATIVE TO BE DESIGNED AND FINALIZED AT CUSTOMER END INSPECTION -

IMPORTANT : CONFIRM FITTMENT OF COUPLING GUARD TITLE:-


ON BASE - PLATE GENERAL
CHD. GANESH ARRA. DRG.
ACCEPTANCE FOR OVERALL DIMENSION + 15mm
CRITICAL DIMENSION ARE + 2mm
APRO. SHARAN SCALE
Jakson and Company NTS. ISSUED ON

Survey No.- 55/1, 55/2, 56/1, 55/3 /1, 57/3/1, 57/2 DRAWING NO.
Village-Kherdi, Khanvel - Talasari Road, Silvassa, D & NH
REV. JC.CPHM-8032.+250M
ZONE BRIEF DESCRIPTION OF REVISION SIGN/DATE