Texiline HF Single Core Marine

Cables Current Ratings Chart

The information in the following tables is according to the definitions in


IEC 60092-201 – electrical installation on ships, single core panel wire.

Current Ratings
Conductor Maximum current Conductor Maximum current
area mm² ratings in Ampere area mm² ratings in Ampere

0.75 13 25 120

1.0 16 35 145

1.5 20 50 180

2.5 28 70 225

4.0 38 95 275

6.0 48 120 320

10 67 150 365

16 90 185 415

The values shown are based on continuous load at 45°C ambient temperature (max.
90°C conductor) and laying of 6 cables maximum in horizontal arrangement,
tightly packed, free air condition around the cable bundle.

Rating factors for higher temperatures


Ambient 46 to 51 to 56 to 61 to 66 to 71 to
Temperature: 50°C 55°C 60°C 65°C 70°C 75°C

Reduce by: 6% 13% 21% 29% 39% 50%