Download as pdf
Download as pdf
You are on page 1of 3
Technical Data Sheet Jotaplast Primer Product description Type [An economy modified acrylic water based sealer that provides proper foundation for interior wall topcoat Features and benefits Enhance Topcoat Kiing- A base coat that enhances topcoat hiding opacity. Easy to apply - Efortless application without fuss. Recommended use For interior application, suitable for new buildings and repainting. Substrate (on concrete, masonry, plaster, brick work and soft board surfaces, Product data Packaging size Packing may vary from country to country according to local requirements, Colours White Solids by volume 36 £2 volumew Application data Remarks Handle with care. Stir well before use. Application equipment / methods By brush, roller, airless spray or conventional spray. Guiding data for airless spray Nozzle tip 0.023" - 0.027" Spray angle degrees 65-80° Pressure at nozzle 140 - 190 kg/em? (2100 ps!) Spreading rate per coat Theoretical 9 ml 12 ml Spreading rate depends on film thickness applied, type of texture, surface porosity, imperfections, temperature, wastage during painting etc. Recommended film thickness per coat wet 83 um 11 um Dry 30 um - 40 um Fl thickness will vary and is calculated as average. Technical Data Sheet ‘SJOTUN Jotaplast Primer Jotun Pte overt Thinner Water Dilution ‘The paint is ready to use after proper stirring. If thinning is required, water may be added up to a maximum of 5%, Conditions during application ‘The temperature of the substrate should be minimum 10 °C and at least 3 °C above the dew point ofthe air, ‘measured in the vicinity of the substrate. Good ventilation is usually required In confined areas to ensure proper drying Drying times Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with Good ventlation (Outdoor exposure or free circulation of ar) Typical flm thickness. One coat on top of inert substrate ‘The given data must be considered as guidelines only. The actual drying time and time before recoating may be shorter or longer, depending on the ambient temperature, film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc, A complete system can be described on a system sheet, where all parameters and special conditions could be included. 1, Recommenced data given is, for recaating with the same generic type of paint. 21 In case of multi-coat application, drying times willbe influenced by the number and sequence and by the total thickness of previous coats applie. 33. The surface should be dry and free fram any contamination prior to application of the subsequent coat. ‘The drying time is measured by stated values: Relative Humidity (RH) 50 % Substrate temperature 10°C 23°C 40°C Surface (touch) dry 2h th Osh Hard dry ah 6h an Dry to over coat, minimum 4h 2h in Directions for use Surface prepara ‘The substrate must be sound, clean, dry and free from dust, ol, grease, laitance ete, All races of form release ‘agents/curing agents must be removed. A lignt sanding with sultable abrasive material is recommended before application. Any resulting dust/loose particles must be removed. Recommended paint system Primer Jotaplast Primer : 1 coat Topcoat Jotaplast : 2 coats Technical Data Sheet ‘SJOTUN Jotaplast Primer Jotun Pte overt Storage ‘The product must be stored in accoréance with national regulations. Keep the containers in 2 dry, cool, well ventilated space ane away from sources of heat and ignition. Containers must be kept tightly closed. Handle with care. Tests Volume Solids % measured according to ISO 3233:1998 (€), Health and safety Please observe the environmental and precautionary notices displayed on the container. ‘A Material Safety Data Sheet for the product has been issued. Detailed information regarding nealth and safety risks and precautions for the use of this product is specified in the product's Safety Data Sheet. First-aid measures, refer to section 4. Handling ang storage, refer to section 7. Transport information, refer to section 14, Regulatory information, refer to section 15. Disclaimer ‘The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and practical experience, Jotun’s products are consiGered as semi-finished goods and as such, products are often Used under concitions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product Itself. Minor product variations may be implemented in order to comply with local requirements, Jotun reserves the right to change the given data without further notice. Users should always consult Jotun for specific guidance on the general suitability of this product for their needs and specific application practices. If there is any inconsistency between different language issues of th's document, the English (United Kingdom) version will preva

You might also like