ACI Multisite Deployment

John Schaper, Technical Solutions Architect


Agenda
• ACI Introduction and Multi-Fabric Use Cases
• ACI Multi-Fabric Design Options
• ACI Stretched Fabric Overview
• ACI Multi-Pod Deep Dive
• ACI Multi-Site Solutions Overview
• Conclusions
Session Objectives

At the end of the session, the participants should be able to:


 Articulate the different Multi-Fabric deployment options
offered with Cisco ACI
 Understand the design considerations associated to those
options
Initial assumption:
 The audience already has a good knowledge of ACI main
concepts (Tenant, BD, EPG, L2Out, L3Out, etc.)
Introducing: Application Centric Infrastructure (ACI)

Web App DB
Outside QoS QoS QoS
(Tenant
Filter Service Filter
VRF)

APIC

Application Policy
ACI Fabric Infrastructure Controller
Integrated GBP VXLAN Overlay

6
ACI Model Tenant L3, L2 Isolation
Tenant
EPG … Outside
subnet self-contained
L2 or L3 tenant definition
EPG APP SERVER representable as
BD a recursive
structured text
subnet
EPG WEB subnet
document
EP
EP BD
With or
EP without
. flooding
semantics
. L3 context
Application profile
. (isolated tenant VRF)
ACI MultiPod/MultiSite Use Cases

 Single Site Multi-Fabric


Multiple Fabrics connected within the same DC (between halls, buildings, … within the
same Campus location)
Cabling limitations, HA requirements, Scaling requirements

 Single Region Multi-Fabric (Classic Active/Active scenario)


Scoped by the application mobility domain of 10 msec RTT
BDs/IP Subnets can be stretched between sites
Desire is reducing as much as possible fate sharing across sites, yet maintaining
operational simplicity

 Multi Region Multi-Fabric


Creation of separate Availability Zones
Disaster Recovery – Minimal Cross Site Communication
Deployment of applications not requiring Layer 2 adjacency
Agenda
• ACI Introduction and Multi-Fabric Use Cases
• ACI Multi-Fabric Design Options
• ACI Stretched Fabric Overview
• ACI Multi-Pod Deep Dive
• ACI Multi-Site Solutions Overview
• Conclusions
ACI Multi-Fabric Design Options
Single APIC Cluster/Single Domain Multiple APIC Clusters/Multiple Domains
Stretched Fabric Dual-Fabric Connected (L2 and L3 Extension)
ACI Fabric ACI Fabric 1 ACI Fabric 2
Site 1 Site 2

L2/L3

Multi-Pod (Q3CY16) Multi-Site (Future)

Pod ‘A’ IP Network Pod ‘n’ Site ‘A’ IP Network Site ‘n’

MP-BGP - EVPN

… MP-BGP - EVPN

APIC Cluster
Dual-Fabric with Common Default GW
New in 11.2 (Brazos)
• Two independent ACI fabrics. Two • L2 connection between fabrics.
management and configuration domains. Active/Active or Active/Standby
• Active/Active workload. Extend L2 and • Consistent end-to-end policy
subnet across.
• Dark fiber/OTV for L2 extension
• Common default GW on both fabrics

ACI Fabric 1 ACI Fabric 2

BD1 BD1
GW : 1.1.1.1 GW : 1.1.1.1
BD2 BD2
GW : 2.2.2.2 GW : 2.2.2.2

Subnet-1, Default GW 1.1.1.1

Subnet-2, Default GW 2.2.2.2


Dual-Fabric with Common Default GW
Active/Active Routing Consideration
• A new virtual IP and virtual MAC are introduced under BD to support common pervasive GW
feature across ACI fabrics.

Fabric 1 Config Fabric 2 Config

Unique “SVI” MAC


between two fabrics

New
Common virtual MAC

Unique “SVI” IP
between two fabrics

Common virtual IP New


between two fabrics
Dual Fabric Policy
• Endpoint Group (EPG) membership is lost when packets transit between 2
separate fabrics
• ACI advantages lost when transiting fabrics
• Unable to enforce granular policy
• Inter-DC traffic treated the same as WAN traffic
ACI Toolkit Intersite Overview
What it does
• Extends Endpoint Groups (EPGs) across multiple sites
• Each site has its own APIC cluster
• Allows policies to be enforced across fabrics
• Preserves EPG membership without carrying it in packet encapsulation
• Runs as an External Application
What it doesn’t do
• Sync contract configuration across sites
• Cost additional $$$ (open source)
Agenda
• ACI Introduction and Multi-Fabric Use Cases
• ACI Multi-Fabric Design Options
• ACI Stretched Fabric Overview
• ACI Multi-Pod Deep Dive
• ACI Multi-Site Solutions Overview
• Conclusions
Stretched ACI Fabric
ACI Stretched Fabric

DC Site 1 DC Site 2

vCenter

Transit leaf Transit leaf

 Fabric stretched to two sites  works as a  Work with one or more transit leaf per site 
single fabric deployed within a DC any leaf node can be a transit leaf
 One APIC cluster  one management and  Number of transit leaf and links dictated by
configuration point redundancy and bandwidth capacity decision
 Anycast GW on all leaf switches  Different options for Inter-site links (dark fiber,
DWDM, EoMPLS PWs)
Stretched ACI Fabric
Option – Ethernet over MPLS (EoMPLS) Port mode
DC Site 1 DC Site 2

10 ms RTT
800 KM / 500 miles
QSFP-40G-SR4

40G
10G/40G/100G
40G

EoMPLS Pseudowire

10G/40G/100G
40G 40G

WAN

 Port mode EoMPLS used to stretch the ACI  1.0(3f) release or later, 10ms max RTT between
fabric over long distance sites
DC Interconnect links could be 10G (minimum) or Under normal conditions 10 ms allows us to support two
higher with 40G facing the Leaf/Spine nodes DCs up to 800 Km apart
DWDM or Dark Fiber provide connectivity between Other ports on the Router used for connecting to the WAN
two sites via L3Out
Stretched ACI Fabric
Support for 3 Interconnected Sites (11.2) Site 2

 Transit leafs in all sites connect to the


local and remote spines

Site 1

Site 3
Transit Leaf

2x40G or 4x40G
Agenda
• ACI Introduction and Multi-Fabric Use Cases
• ACI Multi-Fabric Design Options
• ACI Stretched Fabric Overview
• ACI Multi-Pod Solution Deep Dive
• ACI Multi-Site Solutions Overview
• Conclusions
ACI Multi-Pod Solution
Overview
Inter-Pod Network

Pod ‘A’ Pod ‘n’

MP-BGP - EVPN

Single APIC Cluster


IS-IS, COOP, MP-BGP IS-IS, COOP, MP-BGP

 Multiple ACI Pods connected by an IP Inter-Pod  Forwarding control plane (IS-IS, COOP)
L3 network, each Pod consists of leaf and spine fault isolation
nodes  Data Plane VXLAN encapsulation between
 Managed by a single APIC Cluster Pods
 Single Management and Policy Domain  End-to-end policy enforcement
ACI Multi-Pod Solution
Use Cases
 Handling 3-tiers physical Pod
cabling layout Inter-Pod
Leaf Nodes Network
Cable constrain (multiple
buildings, campus, metro)
requires a second tier of “spines” Spine Nodes
Preferred option when compared
to ToR FEX deployment

 Evolution of Stretched Fabric Pod 1 Pod 2


design
Metro Area (dark fiber, DWDM),
L3 core
APIC Cluster
DB Web/App Web/App
>2 interconnected sites
ACI Multi-Pod Solution
SW and HW Requirements

 Software
The solution will be available from Q3CY16 SW Release

 Hardware
The Multi-Pod solution can be supported with all currently shipping Nexus
9000 platforms
The requirement is to use multicast in the Inter-Pod Network for handling
BUM (L2 Broadcast, Unknown Unicast, Multicast) traffic across Pods
ACI Multi-Pod Solution
Supported Topologies
Intra-DC Two DC sites connected
back2back
10G/40G/100G
40G/100G 40G/100G
Pod 1 Pod n Pod 1 40G/100G 40G/100G
Pod 2
Dark fiber/DWDM (up
to 10 msec RTT)

APIC Cluster
DB Web/App Web/App DB
APIC Cluster
Web/App Web/App

3 DC Sites Multiple sites interconnected


Pod 1 Pod 2
40G/100G
10G/40G/100G
40G/100G
by a generic L3 network
Dark fiber/DWDM (up 40G/100G 40G/100G
to 10 msec RTT)

L3
40G/100G 40G/100G 40G/100G

Pod 3
ACI Multi-Pod Solution
Scalability Considerations

Those scalability values may change without warning before the


Multi-Pod solution gets officially released

 At FCS, the maximum number of supported ACI leaf nodes is 400


(across all Pods)
 200 is the maximum number of leaf nodes per Pod
 Use case 1: larger number of Pods (up to 20) with a small number of
leaf nodes in each Pod (20-30)
 Use case 2: low number of Pods (2-3) with large number of leaf
nodes in each Pod (up to 200)
ACI Multi-Pod Solution
Inter-Pod Network (IPN) Requirements
 Not managed by APIC, must be pre-configured

 IPN topology can be arbitrary, not mandatory to 40G/100G 40G/100G


Pod ‘A’ Pod ‘B’
connect to all spine nodes
MP-BGP - EVPN
 Main requirements:
40G/100G interfaces to connect to the spine nodes DB Web/App
APIC Cluster Web/App

Multicast BiDir PIM  needed to handle BUM traffic

DHCP Relay to enable spine/leaf nodes discovery across Pods

OSPF to peer with the spine nodes and learn VTEP reachability

Increased MTU support to handle VXLAN encapsulated traffic

QoS (to prioritise intra APIC cluster communication)


APIC – Distributed Multi-Active Data Base

One copy is ‘active’ for every


The Data Base is specific portion of the Data
replicated across APIC Base
nodes
Shard 1 Shard 1 Shard 1
APIC APIC APIC
Shard 2 Shard 3 Shard 2 Shard 3 Shard 2 Shard 3

 Processes are active on all nodes (not active/standby)


 The Data Base is distributed as active + 2 backup instances (shards) for every attribute
APIC – Distributed Multi-Active Data Base

Shard 1 Shard 11
Shard Shard 1
APIC APIC APIC
Shard 2 Shard 3 Shard 2 Shard 3 Shard 2 Shard 3

 When an APIC fails a backup copy of the shard is promoted to active and it takes over
for all tasks associated with that portion of the Data Base
APIC – Design Considerations

APIC APIC APIC APIC APIC

X X
APIC APIC APIC

Additional APIC will increase the system APIC will allow read-only access to the DB
scale (today up to 5 nodes supported) but when only one node remains active
does not add more redundancy (standard DB quorum)

APIC APIC 800km

There is a max supported distance between


data base (APIC) nodes – 800km
APIC
X
APIC APIC APIC 800km APIC

NOT RECOMMENDED: failure of site 1 may


cause irreparable loss of data for some
APIC

shards and inconsistent behaviour for others


ACI Multi-Pod Solution
APIC Cluster Deployment Considerations

 APIC cluster is stretched across multiple Pods


Central Mgmt for all the Pods (VTEP address, VNIDs,
class-IDs, GIPo, etc.)
Pod ‘A’ Pod ‘B’
Centralised policy definition
Recommended not to connect more than two APIC MP-BGP - EVPN
nodes per Pod (due to the creation of three replicas
per ‘shard’) DB APIC Cluster
Web/App Web/App

 The first APIC node connects to the ‘Seed’ Pod


Drives auto-provisioning for all the remote Pods

 Pods can be auto-provisioned and managed


even without a locally connected APIC node
ACI Multi-Pod Solution
Auto-Provisioning of Pods
5 4
6
DHCP requests are relayed
3 by the IPN devices back to 7
Provisioning interfaces on the the APIC in Pod 1 Spine 1 in Pod 2 connects
spines facing the IPN and EVPN to the IPN and generates
2 control plane configuration 5 DHCP requests

3 6 4
DHCP response reaches Spine 1
allowing its full provisioning

2 7
Discovery and Discovery and
provisioning of all the
devices in the local Pod
11 Single APIC Cluster
8
provisioning of all the
devices in the local Pod
APIC Node 1 connected to a
9 APIC Node 2 connected
APIC Node 2 joins the to a Leaf node in Pod 2
Leaf node in ‘Seed’ Pod 1
‘Seed’ Pod 1 Cluster Pod 2
8
9 1
10 Discover other Pods following the same procedure
ACI Multi-Pod Solution
IPN Control Plane
IPN Global VRF
IP Prefix Next-Hop
10.0.0.0/16 Pod1-S1, Pod1-S2, Pod1-S3, Pod1-S4

10.1.0.0/16 Pod2-S1, Pod2-S2, Pod2-S3, Pod2-S4


 Separate IP address pools for VTEPs
assigned by APIC to each Pod
OSPF OSPF
Summary routes advertised toward the IPN
via OSPF routing
IS-IS to OSPF
 Spine nodes redistribute other Pods mutual redistribution
10.0.0.0/16 10.1.0.0/16
summary routes into the local IS-IS
process DB APIC Cluster
Web/App Web/App
Needed for local VTEPs to communicate with
remote VTEPs Leaf Node Underlay VRF
IP Prefix Next-Hop
10.1.0.0/16 Pod1-S1, Pod1-S2, Pod1-S3, Pod1-S4
ACI Fabric – Integrated Overlay
Decoupled Identity, Location & Policy

APIC

VTEP VXLAN IP Payload

VTEP VTEP VTEP VTEP VTEP VTEP

 ACI Fabric decouples the tenant end-point address, it’s “identifier”, from the location of that end-
point which is defined by it’s “locator” or VTEP address
 Forwarding within the Fabric is between VTEPs (ACI VXLAN tunnel endpoints) and leverages an
extender VXLAN header format referred to as the ACI VXLAN policy header
 The mapping of the internal tenant MAC or IP address to location is performed by the VTEP using
a distributed mapping database
Host Routing - Inside
Inline Hardware Mapping DB - 1,000,000+ Hosts
10.1.3.35 Leaf 3
10.1.3.11 Leaf 1
Global Station Table Proxy Proxy Proxy Proxy fe80::8e5e Leaf 4
contains a local cache fe80::5b1a Leaf 6
of the fabric endpoints

10.1.3.35 Leaf 3
Proxy Station Table contains
addresses of ‘all’ hosts attached
* Proxy A to the fabric

10.1.3.11 Port 9

10.1.3.11 10.1.3.35 fe80::462a:60ff:fef7:8e5e fe80::62c5:47ff:fe0a:5b1a

Local Station Table  The Forwarding Table on the Leaf Switch is divided between local (directly attached) and
contains addresses of global entries
‘all’ hosts attached  The Leaf global table is a cached portion of the full global table
directly to the Leaf
 If an endpoint is not found in the local cache the packet is forwarded to the ‘default’
forwarding table in the spine switches (1,000,000+ entries in the spine forwarding table)
What is MP-BGP EVPN?

 BGP based control plane to advertise


VRF Info
Layer-2 MAC and Layer-3 IP information VRF Info Name: VRF-A
Name: VRF-A RD: 50000:1.1.1.2 (auto)
Leverages the EVPN Address Family RD: ImpRR
Route-Target
50000:1.1.1.1 (auto) RR 65000:50000 (auto)
Imp Route-Target 65000:50000 Exp Route-Target 65500:50000 (auto)
VRF Info (auto)
 Virtual Routing and Forwarding (VRF) Exp Route-Target 65500:50000
Name: (auto)VRF-A
RD: 50000:1.1.1.3 (auto)
Layer-3 segmentation for tenants’ routing space Imp Route-Target 65000:50000 (auto)
Exp Route-Target 65500:50000 (auto)
 Route Distinguisher (RD) V2
V1
8-byte field, VRF parameters; unique value to make
VPN IP routes unique: RD + VPN IP prefix

 Selective distribution of VPN routes


RR BGP Route-Reflector
Route Target (RT): 8-byte field, VRF parameter,
unique value to define the import/export rules for V3 iBGP Adjacency
VPNv4 routes
ACI Multi-Pod Solution
Inter-Pods MP-BGP EVPN Control Plane

172.16.1.10 Leaf 1 172.16.1.10 Proxy A


 MP-BGP EVPN used to communicate MP-BGP - EVPN
172.16.2.40 Leaf 3 172.16.2.40 Proxy A
Endpoint (EP) and Multicast Group
172.16.1.20 Proxy B 172.16.1.20 Leaf 4
information between Pods
172.16.3.50 Proxy B 172.16.3.50 Leaf 6
All remote Pod entries associated to a Proxy
VTEP next-hop address Proxy A Proxy B

 Single BGP AS across all the Pods COOP

 BGP EVPN on multiple spines in a Pod 172.16.2.4


APIC Cluster 172.16.1.2 172.16.3.5
172.16.1.1
(minimum of two for redundancy) 0
0 0 0

Some spines may also provide the route


reflector functionality (one in each Pod)
ACI Multi-Pod Solution
Overlay Data Plane
Group
VTEP IP VNID Tenant Packet
Policy

Spine encapsulates
172.16.2.40 Leaf 4 Leaf 4
172.16.1.20 Proxy B traffic to remote 172.16.1.20
Proxy A
172.16.2.40
Proxy B Spine VTEP Spine encapsulates
traffic to local leaf
3 4
Proxy A Proxy B

172.16.2.40 Pod1 L4

* Proxy A
5 * Proxy B

VM2 unknown, traffic is 2 Leaf learns remote VM1


encapsulated to the local Single APIC Cluster location and enforces policy
Proxy A Spine VTEP (adding 172.16.2.40 172.16.1.20
S Class information) 1 1 6
VM1 sends traffic If policy allows it, VM2
destined to remote VM2 receives the packet
3
4 6
ACI Multi-Pod Solution
Overlay Data Plane (2)
Group
VTEP IP VNID Tenant Packet
Policy
8

172.16.1.20 Pod2 L4
172.16.2.40 Pod1 L4

* Proxy A
8 * Proxy B

Leaf learns remote VM2 location 9 Leaf enforces policy in


(no need to enforce policy) Single APIC Cluster ingress and, if allowed,
172.16.2.40 172.16.1.20 encapsulates traffic to
1
10 7 remote Leaf node L4
VM1 receives the packet VM2 sends traffic back to
9 From this point VM1 to VM1 communication remote VM1
1
11 is encapsulated Leaf to Leaf (VTEP to VTEP) 7
ACI Multi-Pod Solution
Handling of Multi-Destination Traffic (BUM*)
IPN replicates traffic to all
the Pods that joined GIPo 1 4
(optimised delivery to Pods)
5
Spine 2 is responsible to 4
send GIPo 1 traffic toward
the IPN
3

BUM frame is flooded along the


tree associated to GIPo 1. VTEP
* 2 5 learns VM1 remote location
*
172.16.2.40 Pod1 L4
BUM frame is associated to
GIPo 1 and flooded intra-Pod Single APIC Cluster Proxy B
*
via the corresponding tree 172.16.2.40 172.16.1.20
1 6
VM1 generates a BUM VM2 receives the BUM
23 frame 6 frame

*L2 Broadcast, Unknown Unicast and Multicast


ACI Multi-Pod Solution
Traditional WAN Connectivity

 A Pod does not need to have a dedicated


WAN connection
Pod 1 Pod 2
 Multiple WAN connections can be deployed
across Pods MP-BGP - EVPN

 Traditional L3Out configuration


Shared between tenants or dedicated per tenant
(VRF-Lite)
 VTEPs always select WAN connection in
WAN WAN
the local Pod based on preferred metric
Inbound traffic may require “hair-pinning” across Pod 3
the IPN network
Recommended to deploy clustering technology
when stateful services are deployed
ACI Integration with WAN at Scale
‘Project GOLF’ Overview
‘GOLF’ Devices  Addresses both control plane and data
WAN plane scale
VXLAN data plane between ACI spines and
WAN Routers
MP-BGP BGP-EVPN control plane between ACI spines
EVPN IP Network and WAN routers
OpFlex for exchanging config parameters (VRF
names, BGP Route-Targets, etc.)

 Consistent policy enforcement on ACI leaf


nodes (for both ingress and egress
VRF-1
directions)
VRF-2
 ‘GOLF’ Router support (Q3CY16)

Nexus 7000, ASR9000 and ASR1000 (not yet


Web/App
committed)
ACI Integration with WAN at Scale
Supported Topologies
Directly Connected
Remote WAN Routers Multi-Pod + GOLF
WAN Routers

WAN WAN WAN

MP-BGP
MP-BGP
EVPN IP Network IP Network
EVPN
MP-BGP
EVPN
Multi-Pod and GOLF
Intra-DC Deployment – Control Plane

GOLF
Devices WAN
WAN routes received on the Pod
spines as EVPN routes and translated
MP-BGP EVPN Control Plane to VPNv4/VPNv6 routes with the spine
proxy TEP as Next-Hop
IPN
Public BD subnets advertised to
GOLF devices with the external
spine-proxy TEP as Next-Hop

Multiple
Pods

Web/App Web/App
... Web/App
DB DB
Single
Single APIC Cluster
APIC Domain
Multi-Pod and GOLF
Intra-DC Deployment – Control Plane

 Option to consolidate ‘Golf’ and


‘IPN’ devices GOLF WAN
Perform pure L3 routing for Inter-Pod Devices
VXLAN traffic
VXLAN Encap/Decap for WAN to DC IPN
traffic flows

Multiple
Pods

Web/App Web/App
... Web/App
DB DB
Single
Single APIC Cluster
APIC Domain

*Not available at FCS


Multi-Pod and GOLF
Multi-DC Deployment – Control Plane

GOLF devices inject host routes


into the WAN or register them in
Host routes for endpoint belonging the LISP database
Host routes for endpoint belonging
to public BD subnets in Pod ‘A’
to public BD subnets in Pod ‘B’

MP-BGP EVPN Control Plane


MP-BGP EVPN Control Plane

Pod ‘A’ IPN Pod ‘B’

Web/App Web/App
DB DB
Single APIC Cluster
Multi-Pod and GOLF
Multi-DC Deployment – Data Plane

Traffic from an external user is


GOLF devices VXLAN steered toward the GOLF devices
encapsulate traffic and send it to (via routing or LISP)
the Spine Proxy VTEP address

IPN

Proxy A Proxy B
Spine encapsulates traffic
to the destination VTEP
that can then apply policy

Web/App Web/App
DB DB
Single APIC Cluster
Multi-Pod and GOLF
Multi-DC Deployment – Data Plane (2)

Traffic is received by
the external user
GOLF devices de-encapsulate traffic WAN
and route it to the WAN (or LISP
encapsulates to the remote router)

IPN

Leaf applies policy and


encapsulates traffic directly to
the local GOLF VTEP address

Web/App Web/App
DB
Single APIC Cluster
ACI Multi-Pod Solution
Summary

 ACI Multi-Pod solution represents the natural evolution of the


Stretched Fabric design
 Combines the advantages of a centralised mgmt and policy
domain with fault domain isolation (each Pod runs independent
control planes)
 Control and data plane integration with WAN Edge devices
(Nexus 7000/7700 and ASR 9000) completes and enriches the
solution
 The solution is planned to be available in Q3CY16 and will be
released with a companion Design Guide
Agenda
• ACI Introduction and Multi-Fabric Use Cases
• ACI Multi-Fabric Design Options
• ACI Stretched Fabric Overview
• ACI Multi-Pod Solution Deep Dive
• ACI Multi-Site Solutions Overview
• Conclusions
ACI Dual-Fabric Solution
Overview
ACI Fabric 1 ACI Fabric 2

L2/L3
DCI

 Independent ACI Fabrics interconnected via L2  Data Plane VXLAN encapsulation


and L3 DCI technologies terminated at the edge of each Fabric
 Each ACI Fabric is independently managed by a VLAN hand-off to the DCI devices for providing
Layer 2 extension service
separate APIC cluster
 Requires to classify inbound traffic for
 Separate Management and Policy Domains
providing end-to-end policy extensibility
ACI Multi-Site (Future)
Overview
Inter-Site Network

Site ‘A’ Site ‘n’

MP-BGP - EVPN


Separate APIC
IS-IS, COOP, MP-BGP Clusters IS-IS, COOP, MP-BGP

 Multiple ACI fabrics connected via IP Network  End to end policy enforcement
 Separate availability zones with maximum isolation with policy collaboration
 Separate APIC clusters, separate management and  Support multiple sites
policy domains, separate fabric control planes  Not bound by distance
ACI Multi-Site
Reachability
Inter-Site Network

Site ‘A’ Site ‘n’

MP-BGP - EVPN


Separate APIC
Clusters

 Host Level Reachability Advertised between Fabrics via BGP


 Transit Network is IP Based
 Host Routes do not need to be advertised into transit network
 Policy Context is carried with packets as they traverse the transit IP Network
 Forwarding between multiple Fabrics is allowed (not limited to two sites)
ACI Multi-Site
Policy Collaboration
 EPG policy is exported by source site to desired peer target site fabrics
Fabric ‘A’ advertises which of its endpoints it allows other sites to see
 Target site fabrics selectively imports EPG policy from desired source sites
Fabric ‘B’ controls what it wants to allow its endpoints to see in other sites
 Policy export between multiple Fabrics is allowed (not limited to two sites)

Site ‘A’ Site ‘B’

Web1 Web2 Import Web & App Export Web & App Web1 Web2
from Fabric ‘B’ to Fabric ‘A’

App1 App2 App1 App2


Export Web, App, Import Web, App,
DB to Fabric ‘B’ DB from Fabric ‘A’
dB1 dB1 dB2
Scope of Policy Inter-Site Network

Site ‘A’ Site ‘n’

MP-BGP - EVPN


Separate APIC
Clusters

Web App Web App

 Policy is applied at provider of the contract (always at fabric where the provider endpoint is
connected)
Scoping of changes
No need to propagate all policies to all fabrics
Different policy applied based on source EPG (which fabric)
Agenda
• ACI Introduction and Multi-Fabric Use Cases
• ACI Multi-Fabric Design Options
• ACI Stretched Fabric Overview
• ACI Multi-Pod Solution Deep Dive
• ACI Multi-Site Solutions Overview
• Conclusions
Conclusions

 Cisco ACI offers different multi-fabric


options that can be deployed today
 There is a solid roadmap to evolve those
options in the short and mid term
 Multi-Pod represents the natural evolution
of the existing Stretched Fabric design
 Multi-Site will replace the Dual-Fabric
approach

 Cisco will offer smooth and gradual


migration path to drive the adoption of
those new solutions
Where to Go for More Information

 ACI Stretched Fabric White Paper


http://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/kb/b_kb-
aci-stretched-fabric.html#concept_524263C54D8749F2AD248FAEBA7DAD78
 ACI Dual Fabric Design Guide
Coming soon!
 ACI Dual Fabric Live Demos
Active/Active ASA Cluster Integration
https://youtu.be/Qn5Ki5SviEA
vCenter vSphere 6.0 Integration
http://videosharing.cisco.com/p.jsp?i=14394
Q&A
Complete Your Online Session Evaluation
Give us your feedback and receive a
Cisco 2016 T-Shirt by completing the
Overall Event Survey and 5 Session
Evaluations.
– Directly from your mobile device on the Cisco Live
Mobile App
– By visiting the Cisco Live Mobile Site
http://showcase.genie-connect.com/ciscolivemelbourne2016/
– Visit any Cisco Live Internet Station located
throughout the venue
Learn online with Cisco Live!
T-Shirts can be collected Friday 11 March Visit us online after the conference
for full access to session videos and
at Registration presentations.
www.CiscoLiveAPAC.com
Thank you

You might also like