620

SPECIFICATIONS

BLOCK 3 BLOCK 2 BLOCK 1 TYPE MAST ARM (1.5 m)


270

LAMP LED

LOT 15
LOT 15

LOT 15

LOT 14
LOT 14

LOT 14

LOT 28
LOT 28

LOT 28

LOT 1
LOT 1

LOT 1
WATTAGE 70W

POLE HEIGHT 8m

LOT 13
LOT 13

LOT 13

LOT 16
LOT 16

LOT 16

LOT 27
LOT 27

LOT 27

LOT 2
LOT 2

LOT 2
BASE PLATE COLOR COOL WHITE
POLE

SPACING 35 m

LOT 12
LOT 12

LOT 12

LOT 26
LOT 26

LOT 26

LOT 17
LOT 17

LOT 17

LOT 3
LOT 3

LOT 3
RIB PLATE
SPACING PATTERN ONE-SIDE

ANCHOR BOLT
DESIGN GUIDELINE 0.6 cd/m²

LOT 11
LOT 11

LOT 11

LOT 25
LOT 25

LOT 25

LOT 18
LOT 18

LOT 18
BASE PLATE

LOT 4
LOT 4

LOT 4
35 000
8 000

LOT 19
LOT 19

LOT 19

LOT 24
LOT 24

LOT 24

LOT 10
LOT 10

LOT 10

LOT 5
LOT 5

LOT 5
SKU: FLSRL250 SPECIFICATIONS

8 000 MATERIAL

COLOR
POLYCARBONATE

WARM/COOL WHITE

LOT 20
LOT 20

LOT 20

LOT 23
LOT 23

LOT 23
STYLE MODERN

LOT 9

LOT 6
LOT 9

LOT 6

LOT 9

LOT 6
LIGTH FIXTURE FORM PATH

BRAND PHILIPS

EFFICACY 100 LUMENS PER WATT

LOT 21
LOT 21

LOT 21

LOT 22
LOT 22

LOT 22

LOT 8

LOT 7
LOT 8

LOT 7

LOT 8

LOT 7
WATTAGE 70 WATTS

ALUMINUM PRESSURE DIE


TYPE
CAST

LUMINAIRE SPECIFICATIONS

LOT 15
LOT 15

LOT 15

LOT 14
LOT 14

LOT 14

LOT 28
LOT 28

LOT 28

LOT 1
LOT 1

LOT 1

HANDHOLE

LOT 13
LOT 13

LOT 13

LOT 16
LOT 16

LOT 16

LOT 27
LOT 27

LOT 27

BASE PLATE

LOT 2
LOT 2

LOT 2

2 STREET LIGHT MOUNTING ARRANGEMENT


1

LOT 12
LOT 12

LOT 12

LOT 26
LOT 26

LOT 26

LOT 17
LOT 17

LOT 17

LOT 3
LOT 3

LOT 3

LOT 11
LOT 11

LOT 11

LOT 25
LOT 25

LOT 25

LOT 18
LOT 18

LOT 18

LOT 4
LOT 4

LOT 4

LOT 19
LOT 19

LOT 19

LOT 24
LOT 24

LOT 24

LOT 10
LOT 10

LOT 10

LOT 5
LOT 5

LOT 5

1. ALL ROADWAY LIGHTING IN PUBLIC, PRIVATE, RESIDENTIAL, COMMERCIAL, INDUSTRIAL, MUNICIPAL,


RECREATIONAL OR INSTITUTIONAL PROPERTY SHALL BE AIMED, LOCATED AND DESIGNED IN ACCORDANCE
WITH THE RULES OF REGULATIONS OF ROADWAY LIGHTING GUIDELINES OF THE DEPARTMENT OF ENERGY.
LOT 20
LOT 20

LOT 20

LOT 23
LOT 23

LOT 23

LOT 6
LOT 9
LOT 9

LOT 6

LOT 9

LOT 6

2. FOR NARROW BARANGAY ROADS MEASURING ONE TO THREE (1-3) METERS AND PEDESTRIAN WALKWAYS
IN PROVINCIAL AREAS AND FOR URBAN ALLEYS, THE USE OF OUTDOOR TYPE OF LUMINAIRE WITH HIGH
EFFICIENCY LINEAR/COMPACT FLUORESCENT/LED MAY BE ALLOWED PROVIDED THAT THE LIGHTING
REQUIREMENTS IN TABLE MINIMUM VALUES FOR ROADWAY LIGHTING PARAMETERS (ROADS FOR
MOTORIZED TRAFFIC) ARE MET.

N
LOT 21
LOT 21

LOT 21

LOT 22
LOT 22

LOT 22

LOT 8

LOT 7
LOT 8

LOT 7

LOT 8

LOT 7

3. EQUIPMENT AND GROUNDING CONDUCTOR SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE
PHILIPPINE ELECTRICAL CODE PARTS 1 AND 2.

4. ALL METAL PARTS OF THE RACEWAY SHOULD BE CONNECTED TO THE GROUNDING CONDUCTOR. THESE
INCLUDES THE METAL GROUND BOX LIDS, EXPOSED METAL CONDUIT, METAL POLES, AND SUPPLEMENTAL
GROUND RODS AT POLE FOUNDATIONS (AND OTHER LOCATIONS).
BLOCK 4 BLOCK 5 BLOCK 6 5. THE ROADWAY LIGHTING SHALL BE DESIGNED SO THAT THE FARTHEST LUMINAIRE IN THE BRANCH
CIRCUIT SHALL OPERATE WITHIN THE VOLTAGE SUPPLY LEVEL OF 230+/- 10%. VOLTAGE DROP IS OF
CONCERN IN ORDER TO ASSURE THAT THE VOLTAGE AT ALL LUMINAIRES WILL BE SUFFICIENT FOR THE
LUMINAIRES TO OPERATE PROPERLY, AND ALSO TO AVOID INEFFICIENT OPERATION OF THE LIGHTING
SYSTEM DUE TO A LARGE AMOUNT OF POWER BEING DISSIPATED IN ELECTRICAL DISTRIBUTION SYSTEM.
MERCEDES POBLACION ROADWAY LIGHTING SYSTEM 6. ROADWAY LIGHTING SHOULD BE PROVIDED WITH RELIABLE PHOTOELECTRIC CONTROLS EITHER
INTERNAL/ EXTERNAL TO KEEP LIGHTS TURNED ON/OFF AUTOMATICALLY.

7. ALL ELECTRICAL WORKS AND MATERIALS SHALL COMPLY WITH THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE PARTS 1 AND 2.

8. ALL MATERIALS, EQUIPMENT, AND DEVICES TO BE INSTALLED BY THE CONTRACTOR SHALL BE NEW AND
SHALL BEAR THE CERTIFICATION MARK(PHILIPPINE STANDARD QUALITY MARK OR IMPORT COMMODITY
CLEARANCE) ISSUED BY THE DEPARTMENT OF TRADE AND INDUSTRY-BUREAU OF PRODUCT STANDARDS

W E
(DTI-BPS) FOR SPECIFIC PURPOSES.

9. POLE PLACEMENT SHALL BE BASED ON THE GEOMETRY, CHARACTER OF THE ROADWAY, PHYSICAL
TABLE 6.5.3 PLACEMENT GUIDE FOR ROADWAY LIGHTING FEATURES, ENVIRONMENT, MAINTENANCE POLICY, ECONOMICS, AESTHETICS, AND OVERALL LIGHTING
OBJECTIVES.

10. INDEPENDENT LIGHTING POLES SHALL HAVE MINIMUM THICKNESS OF 3.0 MM AND SHALL BE HOT DIPPED
GALVANIZED IN ACCORDANCE WITH MATERIAL AND FINISH. GENERALLY, POLE SHAFT SHALL BE MADE IN

ROAD ROAD WIDTH LAMP WATTAGE LUMINAIRE SPACING MOUNTING HEIGHT MAST ARM LENGTH ACCORDANCE WITH ASTM A53/A53M STANDARD SPECIFICATION FOR PIPE, STEEL, BLACK ANDHOT-DIPPED,
(m) ARRANGEMENT (W) (m) (m) (m) ZINC-COATED, WELDED AND SEAMLESS.

11. SINGLE SIDED ARRANGEMENT, IN WHICH ALL LUMINAIRES ARE LOCATED ON ONE SIDE OF THE
ROAD,SHALL BE USED WHEN THE ROAD WIDTH IS LESS THAN OR EQUAL TO THE MOUNTING HEIGHT.
10 LINEAR 70 10-40 8 1.5 12. FOR CURVED ROADS, VISUAL GUIDANCE IS ENHANCED BY REDUCING THE LUMINAIRE SPACING.

10 LINEAR 70 10-40 8 1.5 13. BY 25% TO 50% OF THAT NORMALLY APPLIED FOR STRAIGHT ROADS. CURVES WITH A RADIUS OF 1000 m
OR MORE MAY BE TREATED AS STRAIGHT ROADS.

14. THE LED LUMINAIRE SHALL BE DESIGNED FOR LUMEN MAINTENANCE OF L70 OR 70% AT THE END OF
10 LINEAR 70 10-40 8 1.5 USEFUL LIFE AT AMBIENT TEMPERATURE OF NOT LESS THAN45 DEG C (L70 AT 10,000 HOURS). THE
COMPLETE LUMINAIRE SHALL HAVE A USEFUL LIFE OF AT LEAST 50,000 BURNING HOURS.

10 LINEAR 70 10-40 8 1.5


MINOR
10
10
10
LINEAR
LINEAR
LINEAR
70
70
70
10-40
10-40
10-40
8

8
8
1.5

1.5
1.5
S GENERAL NOTES AND/OR SPECIFICATIONS

PROJECT TITLE: DRAW & PREPARED BY: CHECKED BY: SHEET CONTENT: REVISION: SHEET NO.

1
MERCEDES POBLACION
ROADWAY LIGHTING SYSTEM -AS SHOWN- E 1

GILBERT B. OBIAS ENGR. LEO GREG D. VILLASANTA


CAMARINES NORTE STATE COLLEGE
BSEE-4A INSTRUCTOR
College of Engineering
LOCATION: BRGY. SAN ROQUE MERCEDES, CAMARINES NORTE DATE: DECEMBER 12, 2022 DATE: